首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An ion chromatographic method for the simultaneous determination of organic acids and inorganic ions is described. Acetic, malic, ascorbic, citric, malic and succinic acids, chloride and phosphate were determined in coffee and tea samples. The separation is performed on an anion-exchange column operated at 40 °C within 25 min by an isocratic elution with 0.6 mM aqueous potassium hydrogenphthalate (pH 4.0) solution containing 4% (v/v) acetonitrile as eluent and determination by conductivity detection. The method does not need a special sample treatment and was successfully applied to the analysis of black, green and oolong tea samples. Also, green and roasted coffee samples from the varieties arabica and robusta were analyzed.  相似文献   

2.
In boiling aqueous solution, D-amygdalin usually begins to convert into neoamygdalin in 3 min and more than 30% of the initial D-amygdalin is found as neoamygdalin after 30 min. In this report, we establish methods for simple HPLC analysis and the inhibition of D-amygdalin conversion. D-Amygdalin and its conversion product, neoamygdalin, were clearly separated on reverse-phase column chromatography by an optimized eluent of 10 mM sodium phosphate buffer (pH 3.8) containing 6% acetonitrile. Linearity for analyzing D-amygdalin and neoamygdalin was observed in the range from 0.05 to 0.5 mM. The detection limits for D-amygdalin and neoamygdalin were ca. 5 microM per injected amount. We found that D-amygdalin conversion was completely inhibited by adding 0.05% citric acid to the aqueous solution before boiling. To prevent the loss of pharmaceutical potency of Tonin, we applied this method to measure the conversion rate of D-amygdalin. We confirmed that D-amygdalin conversion in Tonin is effectively inhibited by acidic boiling solution with 0.1% citric acid.  相似文献   

3.
A novel ion chromatographic method was proposed for the simultaneous determination of artificial sweeteners (sodium saccharin, aspartame, acesulfame-K), preservatives (benzoic acid, sorbic acid), caffeine, theobromine and theophylline. The separation was performed on an anion-exchange analytical column operated at 40 degrees C within 45 min by an isocratic elution with 5 mM aqueous NaH2PO4 (pH 8.20) solution containing 4% (v/v) acetonitrile as eluent, and the determination by wavelength-switching ultraviolet absorbance detection. The detection limits (signal-to-noise ratio 3:1) for all analytes were below the sub-microg/ml level. Under the experimental conditions, several organic acids, including citric acid, malic acid, tartaric acid and ascorbic acid, did not interfere with the determination. The method has been successfully applied to the analysis of various food and pharmaceutical preparations, and the average recoveries for real samples ranged from 85 to 104%. The levels of all analytes determined by this method were in good agreement with those obtained by the high-performance liquid chromatographic procedure. The results also indicated that ion chromatography would be possibly a beneficial alternative to conventional high-performance liquid chromatography for the separation and determination of these compounds.  相似文献   

4.
Some factors influencing the separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection were investigated. These factors include eluent concentration, column temperature, and detection waveform. The selectivity changes in weakly retained amino acids are slight with changing sodium hydroxide eluent concentration. When sodium acetate eluent concentration is changed, the selectivity variations between strongly retained amino acids containing two carboxyl groups and containing only one carboxyl group are obviously different. Significant but slight selectivity changes in weakly retained amino acids can be achieved through changing the column temperature. Sodium hydroxide and sodium acetate eluent concentration affect the detection of amino acids. Detection sensitivity of amino acids can be improved by increasing the concentration of sodium hydroxide and sodium acetate in a certain concentration range. The detections of amino acids at two different detection waveforms were compared. The hydroxyl amino acids can be selectively detected by choosing a modified detection waveform. The optimized gradient elution condition and column temperature for analyzing 19 amino acids were obtained. The time for the gradient elution program was 60 min. The column temperature was 35 degrees C. Under the optimized conditions, detection limits for 19 amino acids were 0.15-4.52 pmol. The calibration graphs of peak area for all the analytes were linear for about three orders of magnitude. The RSDs (n=5) of peak area were 0.6-5.6%. The determination of trace amino acid impurities in valine product is shown as an application example.  相似文献   

5.
于泓  丁永胜  牟世芬 《色谱》2002,20(5):398-402
 用阴离子交换 积分脉冲安培检测法测定了氨基酸注射液中 1 7种氨基酸和葡萄糖。研究了氨基酸和葡萄糖在阴离子交换中的保留行为。采用了优化的水、NaOH和NaAc三元梯度淋洗条件。在优化的梯度淋洗条件和积分脉冲安培检测条件下 ,氨基酸和葡萄糖的检出限为 0 3pmol~ 1 0 3pmol,线性范围约为 2个数量级。样品加标回收率为 88 3 %~ 1 0 4 6 %。方法简单、灵敏、准确。  相似文献   

6.
A highly sensitive and simple reversed phase high performance liquid chromatographic (HPLC) method for the quantitative determination of free fatty acids in human serum is presented. The method is based on the direct derivatization of serum fatty acids with 6,7-dimethoxy-1-methyl-2(1H)-quinoxalinone-3-propionylcarboxylic acid hydrazide. The derivatization reaction proceeds in aqueous solution in the presence of pyridine and 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide at 37 degrees C. The resulting derivatives are separated within 75 min on a reversed phase column (YMC Pack C8) with a gradient elution of aqueous acetonitrile and detected fluorimetrically. The detection limits are 2.5-5 fmol in a 10 microL injection volume. The sensitivity permits precise determination of free fatty acids in 5 microL serum. The method is simple and is without the conventional liquid-liquid extraction steps of serum fatty acids.  相似文献   

7.
建立了同时测定人体尿液中邻苯二甲酸酯及其代谢物的分析方法.对洗脱剂种类、洗脱体积、洗脱流速等影响因素进行考察,确定了最佳洗脱剂及洗脱体积为2mL乙腈、2mL乙酸乙酯和1mL乙醚-正己烷(1:19,V/V),洗脱流速1mL/min.在最优化的固相萃取-液相色谱条件下测定5种邻苯二甲酸酯及其5种相应的单酯代谢物,线性范围为...  相似文献   

8.
This work presents an HPLC method for the quantification of free amino acids in lyophilized protein fraction from shrimp waste hydrolysate which is obtained by acid lactic fermentation and analyzed using pre-column derivatization with 9-fluorenylmethyl-chloroformate. The amino acids were separated in a Hypersil ODS 5 microm column (250 mm x 4.6 mm) at 38 degrees C. The mobile phase was a mixture of phase A: 30 mM ammonium phosphate (pH 6.5) in 15:85 (v/v) methanol/water; phase B: 15:85 (v/v) methanol/water; and phase C: 90:10 (v/v) acetonitrile/water, with flow rate 1.2 ml/min. Fluorescence detection was used at an excitation wavelength of 270 nm and an emission wavelength of 316 nm. Method precisions for the different amino acids were between 4.4 and 7.1% (relative standard deviation, RSD); detection limits were between 23 and 72 ng/ml; and the recoveries were between 89.0 and 95.0%. The amino acid present at the highest concentration was tyrosine.  相似文献   

9.
The addition of C1-C7 alcohols (methanol, ethanol, propanol, butanol, heptanol, hexanol and heptanol) to dilute sulfuric acid as eluent in ion-exclusion chromatography using a highly sulfonated styrene-divinylbenzene co-polymer resin (TSKgel SCX) in the H+ form as the stationary phase was carried out for the simultaneous separations of both (a) C1-C7 aliphatic carboxylic acids (formic, acetic, propionic, isobutyric, butyric, isovaleric, valeric, 2-methylvaleric, isocaproic, caproic, 2,2-dimethyl-n-valeric, 2-methylhexanoic, 5-methylhexanoic and heptanoic acids) and (b) benzenecarboxylic acids (pyromellitic, hemimellitic, trimellitic, o-phthalic, m-phthalic, p-phthalic, benzoic and salicylic acids and phenol). Heptanol was the most effective modifier in ion-exclusion chromatography for the improvement of peak shapes and a reduction in retention volumes for higher aliphatic carboxylic acids and benzenecarboxylic acids. Excellent simultaneous separation and relatively highly sensitive conductimetric detection for these C1-C7 aliphatic carboxylic acids were achieved on the TSKgel SCX column (150 x 6 mm I.D.) in 30 min using 0.5 mM sulfuric acid containing 0.025% heptanol as eluent. Excellent simultaneous separation and highly sensitive UV detection at 200 nm for these benzenecarboxylic acids were also achieved on the TSKgel SCX column in 30 min using 5 mM sulfuric acid containing 0.075% heptanol as eluent.  相似文献   

10.
高效液相色谱法快速,灵敏测定尿中3—甲基组氨酸含量   总被引:2,自引:0,他引:2  
本文报道用柱前衍生高液相色谱法快速,灵敏地测定尿中3-甲基组氨酸(3MH)。采用含30%乙腈的10mmol/L磷酸钠缓冲液(pH=7.5)为流动相,等梯度洗脱,10min内即可分析一个样品;在20-3000pmol范围内,3MH线性相关系数为0.9986,相对标准偏差为2.3%(批内)和4.5%(批间);并测定了10名正常人尿中的3MH含量。  相似文献   

11.
Investigations have been initiated to develop a sufficiently good separation of both major and minor organic acids and inorganic anions present in grape musts using a Dionex As11 column, a sodium hydroxide gradient elution and a suppressed conductivity detection. Separation was complicated in aqueous mobile phase by co-elutions and selectivity was optimized using organic modifiers that alter ion-exchange selectivity for hydrophobic ions. In this study, the influence of three different solvents (methanol, ethanol and acetonitrile) on the efficiency of column was compared. The best separation of all ions in a synthetic solution was achieved with an eluent containing 13% (v/v) methanol and 13% (v/v) ethanol in water, the run during only 20 min. This method was next applied to grape juices with success and has shown sensitivity and reproducibility. Moreover, sample preparation was a simple 20-fold dilution with 0.45 microm filtration and direct injection without prior sample clean-up.  相似文献   

12.
A mass spectrometric method with electrospray ionisation (ESI-MS) is described for detection and quantification of selected peptides [glutathione, phytochelatin 2, bombesin, salmon luteinising hormone, and peptide fragment Cys(Xx)12]. A reaction coil was used to introduce a solution of sample in mobile phase consisting of acetonitrile (ACN) and an aqueous solution of trifluoroacetic acid (TFA). l-Ascorbic acid (AA), which substantially increased the abundance of the molecular ions of the peptides analysed, was added to aqueous solutions of the peptides or amino acids at a final concentration of 10 mM. This addition probably eliminated the negative effect on the ionisation processes of the strong acid TFA present in the mobile phase, thus enabling analysis of lower concentrations of the peptides.  相似文献   

13.
The highly cross-linked 12% agarose gel Superose 12 10/300 GL causes retardation of glycine peptides when mobile phases containing varying concentrations of acetonitrile in water are used. An investigation has been made into the retention mechanism behind this retardation using the glycine dipeptide (GG) and tripeptide (GGG) as models. The dependence of retention times of analytical-size peaks under different experimental conditions was interpreted such that the adsorption most probably was caused by the formation of hydrogen bonds but that electrostatic interactions cannot be ruled out. Thereafter, a nonlinear adsorption study was undertaken at different acetonitrile content in the eluent, using the elution by characteristic points (ECPs) method on strongly overloaded GG and GGG peaks. With a new evaluation tool, the adsorption energy distribution (AED) could be calculated prior to the model selection. These calculations revealed that when the acetonitrile content in the eluent was varied from 0% to 20% the interactions turned from (i) being homogenous (GG) or mildly heterogeneous (GGG), (ii) via a more or less stronger degree of heterogeneity around one site to (iii) finally a typical bimodal energy interaction comprising of two sites (GG at 20% and GGG at 10% and 20%). The Langmuir, Tóth and bi-Langmuir models described these interesting adsorption trends excellently. Thus, the retardation observed for these glycine peptides is interpreted as being of mixed-mode character composed of electrostatic bonds and hydrogen bonds.  相似文献   

14.
黄翼飞  胡静 《色谱》2010,28(6):615-622
建立了液相色谱-电喷雾离子阱串联质谱(LC-ESI-IT-MS/MS)同时分析烟草中20种游离氨基酸的方法。烟草样品经萃取后过滤直接进样,无需进行衍生和固相萃取等其他前处理步骤。液相色谱采用HyPURITY C18反相色谱柱(200 mm×2.1 mm, 5 μm),采用1%(体积分数,下同)乙腈水溶液(含0.1%九氟戊酸)和90%乙腈水溶液(含0.1%九氟戊酸)为流动相进行梯度洗脱。结果表明,20种氨基酸的检出限(LOD)为0.01~0.05 μmol/L (S/N=3),线性相关系数均大于0.9977,峰面积测定的相对标准偏差(RSD)为0.78%~4.93%。该方法分析效率、灵敏度和选择性高,已成功应用于多种烟草样品中氨基酸的分析测定。  相似文献   

15.
高玲  顾强  王红  马行空  薛峰  张幸  葛家春  丁涛  沈伟健 《色谱》2022,40(9):825-832
游离氨基酸不仅是一类重要的营养物质,更与中华绒螯蟹独特的滋味和香味密切相关。对游离氨基酸含量进行测定,能为中华绒螯蟹产品的品质评价和风味研究提供有价值的信息。该工作通过优选提取溶剂、优化仪器测定参数,最终使用5%(v/v)高氯酸水溶液提取目标物,采用XDB-C18色谱柱(100 mm×4.6 mm, 1.7μm),以0.1%(v/v)甲酸水溶液-乙腈为流动相进行梯度洗脱,在电喷雾正离子电离、选择离子扫描模式下进行检测,外标法定量,建立了超高效液相色谱-高分辨质谱(UHPLC-HRMS)测定中华绒螯蟹中17种游离氨基酸含量的方法。结果表明,17种氨基酸在10.0~200.0 mg/L范围内线性关系良好,相关系数(R2)≥0.999 0,仪器检出限为0.3 mg/L,仪器定量限为1.0 mg/L。在中华绒螯蟹可食部分中按三水平进行加标回收试验,各目标物的回收率在78.4%~105.3%之间。通过对仪器和方法精密度进行评估,发现17种氨基酸测定仪器重复性的RSD≤4.2%,方法重复性试验的RSD≤5.2%,再现性试验的RSD≤11.4%,精密度数据...  相似文献   

16.
《Journal of chromatography. A》1995,700(1-2):187-193
HPLC and capillary electrophoretic (CE) methods were compared for the determination of phospholipase A2 and melittin in bee venom. Size-exclusion chromatography on a Tessek Separon HEMA-BIO 40 column requires the use of a denaturing eluent (0.2% trifluoroacetic acid in 20% acetonitrile) to overcome non-specific interactions of some components, e.g., melittin. Reversed-phase HPLC on a HEMA-BIO 1000 C18 column with gradient elution using water-acetonitrile mobile phases containing trifluoroacetic acid and UV spectrophotometric detection at 215 nm permits the identification and determination of the main bee venom components and their preparative chromatography. CE analysis for bee venom components is optimum with electrolyte system of 150 mM phosphoric acid (pH 1.8) with UV spectrophotometric detection at 190 nm. In comparison with HPLC, the CE method is cheaper and faster (6 min vs. 45 min) and the separation is more efficient.  相似文献   

17.
建立了整体柱离子对色谱-紫外检测法梯度淋洗快速分离测定4种吡啶离子液体阳离子的方法。分离采用C18反相硅胶整体柱,以离子对试剂(用柠檬酸调节pH值)-乙腈为淋洗液,并采用多级梯度洗脱程序。实验考察了色谱柱、离子对试剂、乙腈浓度、色谱柱温度及流速对吡啶阳离子保留的影响,并讨论了其保留规律。咪唑阳离子的保留符合碳数规律。最佳色谱条件是:在流速3.0 mL/min,柱温30℃下,以1.0 mmol/L庚烷磺酸钠(pH 4.0)(A)+乙腈(B)为淋洗液进行梯度洗脱。淋洗梯度为0~2.0 min,10%B;2.0~2.5 min,10%~15%B;2.5~4.0 min,15%B;4.0~4.5 min,15%~20%B;4.5~10.0 min,20%B。在此条件下,4种吡啶阳离子可在7 min内基线分离。所测阳离子的检出限(S/N=3)为0.05~0.17 mg/L;峰面积的相对标准偏差(n=5)小于0.6%。将本方法用于实验室合成的离子液体样品和污水样品的分析,加标回收率在95.7%~99.0%之间。本方法准确、快速,具有较好的实用性。  相似文献   

18.
Nineteen biogenic D,L-amino acids are derivatized with highly reactive N-fluorenylmethoxycarbonyl-L-alanyl N-carboxyanhydride. Using a 0.5M borate buffer at pH 7.5 and acetone, the derivatization of amino acids is completed in 5 min at room temperature. Some of the resulting diastereomeric N-protected dipeptides are successfully separated on an octylsilica stationary phase using 100mM acetate buffer (pH 4.4) and acetonitrile as the eluent.  相似文献   

19.
This study describes a rapid and sensitive analytical method for the determination of amino acids in foods and drinks. The method entailed dilution or extraction of amino acids from foods using the mixture of acetonitrile and 0.1% aqueous formic acid (50:50, v/v). Chromatographic separation of underivatized amino acids was performed using a hydrophilic interaction liquid chromatography within a runtime of 6 min. Both hydrophobicity and charge of the side chain played important roles on the elution order of amino acids under the chromatographic conditions. High-resolution mass spectrometry allowed qualitative and quantitative detection of amino acids in complex food matrices. Its response was found linear over a concentration range of 0.25-10 μg/ml. The method could be successfully applied to various foods and drinks to profile individual amino acids. Mean percentage recoveries of amino acids from different matrices were 88.5% or higher with residual standard deviation of less than 5.0%.  相似文献   

20.
A highly sensitive, selective and simple method is described for the determination of histamine by high-performance liquid chromatography (HPLC) with fluorescence detection. The method is based on an intramolecular excimer-forming fluorescence derivatization of histamine with 4-(1-pyrene)butyric acid N-hydroxysuccinimide ester (PSE), followed by reversed-phase HPLC. Histamine, having two amino moieties in a molecule, was converted to the dipyrene-labeled derivative by reaction with PSE. The derivative afforded intramolecular excimer fluorescence (450-540 nm), which can clearly be discriminated from the monomer fluorescence (370-420 nm) emitted from PSE. Typically, a 10 micro L sample solution was mixed with 100 micro L of derivatization reagent solution, which was a mixture of 0.5 mm PSE in acetonitrile and 0.5 mm potassium carbonate in water (8:2, v/v). The derivatization was carried out at 100 degrees C for 90 min. The PSE derivative of histamine could be separated by reversed-phase ODS column with isocratic elution using acetonitrile:water (82:18, v/v) containing 0.03% triethylamine. The detection limit (singnal-to-noise ratio = 3) of histamine was 0.5 fmol for a 30 micro L injection. The method was successfully applied to the determination of histamine in human urine, and had enough selectivity and sensitivity for urinary histamine quantification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号