首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(15):2595-2606
Abstract

An enzyme electrode is made from a glassy carbon electrode covered with a gelatin membrane containing entrapped glycerol dehydrogenase (GDH) and diaphorase, and protected with a dialysis membrane. Based on amplification by the recycling reaction catalyzed by the two-enzyme systems, NAD+ and NADH can be determined with 800–1200 times higher sensitivity than for the same electrode in a substrate sensing mode when the flow rate was 0.08 ml/min. The detection limit was about 0.03 μM for NADH. The amplification factors were around 1000 for 0.08 ml/min, with quite large variations between electrodes. They had decreased to about 70% of the original value after 7 days. The biosensor is intended for detection in immunoassays with alkaline phosphatase as a marker.  相似文献   

2.
Guilbault GG  Seo ML 《Talanta》1994,41(6):1029-1033
Enzyme electrodes for the amperometric measurement of urea were prepared by co-immobilizing l-glutamate dehydrogenase and urease onto an Immobilon-AV affinity membrane with attachment to a glassy carbon electrode. Reduced nicotinamide adenine dinucleotide (NADH) was used as the electroactive species. The electrochemical oxidation of NADH was monitored at +1.0 V vs. Ag/AgCl. The enzyme immobilized electrode was linear over the range of 2.0 x 10(-5) to 2 x 10(-4)M. The response time of the electrode was 3 min and the optimum pH of enzyme immobilized membrane was pH 7.4-7.6 (Dulbecco's buffer solution). It was stable for at least two weeks and 50 assays. There were no interferences from other physiological material, except for high levels of ascorbic acid.  相似文献   

3.
A flow system for substrate recycling of NAD+/NADH was set up with an enzyme reactor containing coimmobilized glycerol dehydrogenase (GDH) and diaphorase. The product from the diaphorase catalysis, hexacyanoferrate(II), aws detected amperometrically at a glassy carbon electrode. The amplification factor was 150 for a reactor volume of 100 μ l at a flow-rate of 0.5 ml/min. With a stopped flow of four minutes, the signal increased another 88 times, resulting in a signal amplification of 13 300 times. Equations are derived for the amplification factor and used for a discussion of the optimization of amplification systems. The Km for GDH with glycerol as a substrate was found to be 5 × 10−3 M at pH 8.0. GDH from Cellulomonas sp. was purified on a gel filtration column and the purified enzyme showed a specificity toward NAD+, compared to NADP+, that was higher than 99.9%. Due to the NAD+ specificity of the purified GDH, the enzyme amplification system reported here could be used in detection systems for enzyme immunoassays when using alkaline phosphatase as a label and NADP+ as a substrate. The stability of immobilized GDH and diaphorase is several orders of magnitude better than that of alcohol dehydrogenase, which is the enzyme commonly used for NAD+-specific detection in these applications.  相似文献   

4.
Meldola Blue (7-dimethylamino-1,2-benzophenoxazine) can be adsorbed on graphite to give chemically modified electrodes. The electrochemical redox reactions of the phenoxazine are fairly reversible at low coverages with an E′o of ?175 mV vs. SCE at pH 7.0. The electrode was most stable in acid solutions, at pH 6.0 its electrochemical activity decreased by 15% during 2h. The adsorbed compound mediated electron transfer in the electrocatalytic oxidation of the nicotinamide coenzymes (NADH and NADPH). The formation of a charge transfer complex between Meldola Blue and the coenzyme is demonstrated by experiments with a rotating disk electrode. The complex decomposes in a rate limiting step (k+2=30 s?1) to the oxidized coenzyme and the reduced Meldola Blue. The latter can be reoxidized in a fast electrochemical step. The overall result is an electrocatalytic oxidation at a voltage which is about 500 mV lower than at an unmodified electrode.  相似文献   

5.
Carbon film resistor electrodes have been evaluated as transducers for the development of multiple oxidase-based enzyme electrode biosensors. The resistor electrodes were first modified with Prussian Blue (PB) and then covered by a layer of covalently immobilized enzyme. Electrochemical impedance spectroscopy was used to characterize the interfacial behaviour of the Prussian Blue modified and enzyme electrodes; the spectra demonstrated that the access of the substrates is essentially unaltered by application of the enzyme layer. These enzyme electrodes were used to detect the substrate of the oxidase (glucose, ethanol, lactate, glutamate) via reduction of hydrogen peroxide at +50 mV versus Ag/AgCl in the low micromolar range. Response times were 1-2 min. Finally, the glucose, ethanol and lactate electrochemical biosensors were used to analyse complex food matrices—must, wine and yoghurt. Data obtained by the single standard addition method were compared with a spectrophotometric reference method and showed good correlation, indicating that the electrodes are suitable for food analysis.  相似文献   

6.
In this work, firstly methylene blue (MB) was electropolymerized onto pencil graphite electrode (PGE) surface for the electrocatalytic oxidation of NADH. Cyclic voltammograms show that oxidation potential of NADH at Poly-MB/PGE shifted to negative direction about 300 mV compared with bare PGE. These results indicate that Poly-MB/PGE exhibits a good electrocatalytic activity toward NADH oxidation. Then, a glucose biosensor study was performed based on the determination of enzymatically generated NADH by glucose dehydrogenase (GDH) which immobilized onto Poly-MB/PGE using glutaraldehyde cross-linking procedure. The biosensing of glucose in flow injection analysis (FIA) system was performed at GDH/Poly-MB/PGE for the first time. The electrocatalytic oxidation currents of enzymatically produced NADH obtained from FI amperometric current–time curves recorded at + 200 mV and in phosphate buffer solution at pH 7.0 containing 1.0 M KCl were linearly related to the concentration of glucose. Linear calibration plots are obtained in the concentration range from 0.01 to 1.0 mM. The limit of detection (LOD) was found to be 4.0 µM. A fast, sensitive, low-cost and disposable glucose biosensor was constructed in FIA system using GDH/Poly-MB/PGE; therefore, it might provide a new perspective for the fabrication of biosensor of other compounds such as glutamate, lactate and alcohol.  相似文献   

7.
Toluidine Blue O (TBO) was covalently bound on silica gel and mixed with graphite powder and paraffin oil to produce modified carbon paste electrodes. The formal potential (E°′) of the covalently bound TBO was found to be −100 mV versus Ag|AgCl (KCl sat.) at pH 7.0 and the E°′ varied less than anticipated for a 2-electron-proton type mediator with pH. The bound TBO was found to act as an efficient electron acceptor for NADH as well as electron donor for oxidised horseradish peroxidase (HRP). The kinetics and the mechanism of the reaction between NADH and TBO were investigated with cyclic voltammetry and using a rotating disc electrode. Further experiments were done in the flow injection mode injecting different concentrations of NADH. Similar studies were done in the presence of hydrogen peroxide when HRP was adsorbed onto the TBO modified silica gel carbon paste electrodes.  相似文献   

8.
A multi-enzyme electrode composed of FAD-dependent and NAD-dependent enzymes was fabricated using a poly-ruthenium complex (PAHA–Ru), which has two 1,10-phenanthroline-5,6-dione molecules as ligands. PAHA–Ru was used to immobilize FAD-dependent glucose dehydrogenase (FAD–GDH) onto an electrode and to examine PAHA–Ru containing the quinone moieties as an electron mediator. In cyclic voltammetry measurements of the FAD–GDH modified electrode in the presence of D-glucose, a catalytic current was obtained, which indicated electron transfer from FAD–GDH to PAHA–Ru. Our previous study has reported that PAHA–Ru with the quinone ligands also works as a mediator for NADH oxidation on an NAD-dependent alcohol dehydrogenase (NAD–ADH) modified electrode. Hence, FAD–GDH and NAD–ADH were co-immobilized with PAHA–Ru to make a multi-enzyme electrode. Using this multi-enzyme electrode as an anode, catalytic currents were observed in D-glucose solution, ethanol solution, and a mixed D-glucose and ethanol solution. The catalytic current in the mixed solution was greater than the currents obtained in the single substrate solutions, indicating bioelectrocatalysis reactions by the two enzymes and the single mediator in the mixed solution. Thus, we demonstrated that PAHA–Ru modified electrode enables selection of enzymes and their substrates from a wider range for enzymatic biofuel cells.  相似文献   

9.
《Electroanalysis》2004,16(11):949-954
The preparation and the electrochemical study of Disperse Blue 1‐chemically modified electrodes (DB1‐CME), as well as their efficiency for the electrocatalytic oxidation of NADH is described. The proposed mediator was immobilized by physical adsorption onto graphite electrodes. The electrochemical behavior of DB1‐CME was studied with cyclic voltammetry. The electrochemical redox reaction of DB1 was found to be reversible, revealing two well‐shaped pair of peaks with formal potentials 152 and ?42 mV, respectively, (vs. Ag/AgCl/3M KCl) at pH 6.5. The current Ip has a linear relationship with the scan rate up to 800 mV s?1, which is indicative for a fast electron transfer kinetics. The dissociation constants of the immobilized DB1 redox couple were calculated pK1=4 and pK2=5. The electrochemical rate constants of the immobilized DB1 were calculated k1°=18 s?1 and k2°=23 s?1 (Γ=2.36 nmol cm?2). The modified electrodes were mounted in a flow injection manifold, poised at +150 mV (vs. Ag/AgCl/3M KCl) and a catalytic current due to the oxidation of NADH was measured. The reproducibility was 1.4% RSD (n=11 for 30 μM NADH) The behavior of the sensor towards different reducing compounds was investigated. The sensor exhibited good operational and storage stability.  相似文献   

10.
《Analytical letters》2012,45(5):783-796
Abstract

An amperometric procedure is described for the determination of glycerol and triglycerides in aqueous samples and in serum using glycerol dehydrogenase immobilized on a collagen membrane. Glycerol is determined by measurement of the steady-state oxidation currents generated at a platinum electrode by NADH produced in the enzyme-catalyzed reaction. The triglycerides were first hydrolyzed by the enzyme lipase in solution and the resulting glycerol determined similarly. Olive oil, determined to contain 78 % triolein, was used as the source of triglycerides in this study. For both glycerol and triglycerides the calibration plots are linear in the range from 0 to 12 μM, with detection limits of 0.2 and 0.7 μM, respectively. The immobilized glycerol dehydrogenase retained high operational activity for a period longer than 30 days.  相似文献   

11.
Diaphorase was immobilized covalently as a monolayer on a tin(IV) oxide electrode, and the diaphorase electrode thus obtained responded to NADH amperometrically in the presence of ferricyanide or 2,6-dichloroindophenol as the electron mediator. The response was one to two orders of magnitude larger than that of a bare electrode. Further derivatization of the diaphorase electrode with a dehydrogenase (glucose, lactate or alcohol dehydrogenase), which reduces NAD to NADH by reaction with the substrate, yielded dehydrogenase/diaphorase heterobilayer-modified electrodes. These electrodes functioned as sensors for the respective substrate with NAD and ferricyanide as the mediators. Each bilayer electrode responded to the substrate only in the presence of added NAD; this provides evidence for the essential contribution of diaphorase to the sensor performance. As much as 60 to 80% of the electron mediator reduced by the enzymatic reaction was utilized in the amperometric response.  相似文献   

12.
Carbon paste electrodes were modified with a nitrofluorenone derivative, 2,4,7-trinitro-9-fluorenone, adsorbed on zirconium phosphate (ZP). After electrochemical reduction of the fluorenone derivative, it turns into a very efficient mediator for electrocatalytic NADH oxidation, with a formal potential of about +250 mV vs. Ag/AgCl. The electrochemistry and the electrocatalytic properties of the mediator were investigated with cyclic voltammetry and rotating disk electrode methodology. The second order rate constant with NADH was evaluated and found to be higher than 10(6) M(-1) s(-1), thus approaching true diffusion controlled currents for NADH oxidation.  相似文献   

13.
Guo K  Qian K  Zhang S  Kong J  Yu C  Liu B 《Talanta》2011,85(2):1174-1179
Characterization and application of graphene sheets modified glassy carbon electrodes (graphene/GC) have been presented for the electrochemical bio-sensing. A probe molecule, potassium ferricyanide is employed to study the electrochemical response at the graphene/GC electrode, which shows better electron transfer than graphite modified (graphite/GC) and bare glassy carbon (GC) electrodes. Based on the highly enhanced electrochemical activity of NADH, alcohol dehydrogenase (ADH) is immobilized on the graphene modified electrode and displays a more desirable analytical performance in the detection of ethanol, compared with graphite/GC or GC based bio-electrodes. It also exhibits good performance of ethanol detection in the real samples. From the results of electrochemical investigation, graphene sheets with a favorable electrochemical activity could be an advanced carbon electrode materials for the design of electrochemical sensors and biosensors.  相似文献   

14.
《Electroanalysis》2017,29(4):950-954
Biofuel cells based on electrocatalytic oxidation of NADH and reduction of H2O2 have been prepared using carbon fiber electrodes functionalized with graphene nano‐flakes. The electrochemical oxidation of NADH was catalyzed by Meldola's blue (MB), while the reduction of H2O2 was catalyzed by hemin, both catalysts were adsorbed on the graphene flakes due to their π‐π staking. In the next set of experiments, the MB‐ and hemin‐electrodes were additionally modified with glucose dehydrogenase (GDH) and glucose oxidase (GOx), respectively. The enzyme catalyzed reactions in the presence of glucose, NAD+ and O2 resulted in the production of NADH and H2O2 in situ. The produced NADH and H2O2 were oxidized and reduced, respectively, at the bioelectrocatalytic electrodes, thus producing voltage and current generated by the biofuel cell. The enzyme‐based biofuel cells operated in a human serum solution modelling an implantable device powered from the natural biofluid. Finally, two enzyme‐based biofuel cell connected in series and operating in the serum solution produced electrical power sufficient for activation of an electronic watch used as an example device.  相似文献   

15.
A monolayer of Nile Blue (NB) has been covalently immobilized on the self-assembled thiol-monolayer modified gold electrode. Cyclic voltammograms indicated a stable and reverse redox process of NB bonded on the electrode surface. The mechanisms of redox process coupling with proton transfer were proposed. The NB-modified electrode showed excellent electrocatalytic activity toward Nicotinamide adenine dinucleotide (NADH) oxidation and horseradish peroxidase (HRP) reduction. A hydrogen peroxide biosensor based on NB as a mediator has been demonstrated.  相似文献   

16.
Integrated, electrically contacted beta-nicotinamide adenine dinucleotide- (NAD(+)) or beta-nicotinamide adenine dinucleotide phosphate- (NADP(+)) dependent enzyme electrodes were prepared on single-walled carbon nanotube (SWCNT) supports. The SWCNTs were functionalized with Nile Blue (1), and the cofactors NADP(+) and NAD(+) were linked to 1 through a phenyl boronic acid ligand. The affinity complexes of glucose dehydrogenase (GDH) with the NADP(+) cofactor or alcohol dehydrogenase (AlcDH) with the NAD(+) cofactor were crosslinked with glutaric dialdehyde and the biomolecule-functionalized SWCNT materials were deposited on glassy carbon electrodes. The integrated enzyme electrodes revealed bioelectrocatalytic activities, and they acted as amperometric electrodes for the analysis of glucose or ethanol. The bioelectrocatalytic response of the systems originated from the biocatalyzed oxidation of the respective substrates by the enzyme with the concomitant generation of NAD(P)H cofactors. The electrocatalytically mediated oxidation of NAD(P)H by 1 led to amperometric responses in the system. Similarly, an electrically contacted bilirubin oxidase (BOD)-SWCNT electrode was prepared by the deposition of BOD onto the SWCNTs and the subsequent crosslinking of the BOD units using glutaric dialdehyde. The BOD-SWCNT electrode revealed bioelectrocatalytic functions for the reduction of O(2) to H(2)O. The different electrically contacted SWCNT-based enzyme electrodes were used to construct biofuel cell elements. The electrically contacted GDH-SWCNT electrode was used as the anode for the oxidation of the glucose fuel in conjunction with the BOD-SWCNT electrode in the presence of O(2), which acted as an oxidizer in the system. The power output of the cell was 23 muW cm(-2). Similarly, the AlcDH-SWCNT electrode was used as the anode for the oxidation of ethanol, which was acting as the fuel, with the BOD-SWCNT electrode as the cathode for the reduction of O(2). The power output of the system was 48 microW cm(-2).  相似文献   

17.
Very sensitive, low cost and reliable NADH and H2O2 sensors were realised and used for development of enzyme based biosensors. The active surface of the electrodes was modified with a nanocomposite obtained by modification of SWNT with a proper mediator: Meldola Blue (for NADH) and Prussian Blue (for H2O2). Low applied potential of − 50 mV vs. Ag/AgCl reference electrode proved the synergistic effect of nanocomposite materials towards NADH and H2O2 detection. Biosensors for malic acid and alkylphenols have been developed, using mediator-functionalised-SWNT-based electrodes and two different classes of enzymes: NAD+-dependent dehydrogenases and peroxidases. Immobilization of the enzymes was realised using a series of different procedures — adsorption, Nafion membrane, sol–gel and glutaraldehyde, in order to find the best configuration for a good operational stability. A higher sensitivity comparing with other reported biosensors of about 12.41 mA/M·cm2 was obtained for l-malic acid biosensor with enzyme immobilised in Nafion membrane. Phenol, 4-t-octylphenol and 4-n-nonylphenol were used as standard compounds for HRP based biosensor. Fast biosensor response and comparable detection limit with HPLC methods were achieved.  相似文献   

18.
A monoenzymatic amperometric biosensor was developed for the detection of acetaldehyde. The sensor is based on the association of screen-printed carbon electrodes and aldehyde dehydrogenase immobilized by a sol-gel entrapment method. Modification of screen-printed carbon electrodes with Reinecke salt of Meldola's Blue (MBRS) resulted in highly sensitive and interference-free nicotinamide-adenine dinucleotide (NADH) detectors. Based on MBRS-mediated oxidation of NADH at -150 mV versus pseudo Ag/AgCl, acetaldehyde was determined in the range 10-260 microM, compatible with wine quality monitoring. The method of immobilization based on sol-gel entrapment was optimized to obtain the best compromise between sensitivity and operational stability. The sensor response was stable for 40 consecutive assays with methyltrimethoxysilane used as alkoxide precursor, thus allowing a possible calibration of the sensor before each measurement. The biosensors were used to analyze French wines. The method was validated with a commercially available enzymatic kit based on a standard spectrophotometric method.  相似文献   

19.
For electrocatalytic determination of NADH, a graphite electrode modified with titania sol-gel/Meldola’s Blue/MWCNT/Nafion nanocomposite was proposed. The composition of the matrix film was optimised in terms of the content of carbon nanotubes and Nafion. Incorporation of a redox mediator, Meldola’s Blue, into the nanocomposite film enabled electrocatalytic determination of NADH at a low potential, −50 mV. For determination of ethanol, alcohol dehydrogenase (ADH) was immobilized into the matrix layer. Experimental conditions affecting the biosensor response were examined, including enzyme loading, temperature of measurement and pH of background electrolyte. Assessments of the analytical characteristics of the biosensor were performed with respect to sensitivity, limit of detection, operational stability, repeatability and reproducibility. The proposed biosensor showed electrocatalytic activity toward oxidation of ethanol with sensitivity of 2.24 μA L mmol−1, linear range from 0.05 to 1.1 mmol L−1, and limit of detection of 25 μmol L−1. The apparent Michaelis-Menten constant was 1.24 mmol L−1, indicating a high biological affinity of ADH/titania sol-gel/Meldola’s Blue/MWCNT/Nafion electrode for ethanol. The developed biosensor was tested in determinations of ethanol content in alcoholic beverages.  相似文献   

20.
《Electroanalysis》2017,29(8):1985-1993
Polytyramine (PT) has been electro‐deposited onto multi‐walled carbon nanotube (MWCNT) modified glassy carbon (GC) electrodes via oxidation of tyramine in 0.1 M H3PO4 by cycling the potential over the range of −400 mV to 1300 mV (versus Ag/AgCl). The reactivity of the resulting chemically‐modified electrodes was characterized using cyclic voltammetry in the presence and absence of reduced nicotinamide adenine dinucleotide (NADH). The modified electrodes displayed electrochemical activity due to the formation of quinone species and were catalytically active towards NADH oxidation by lowering the oxidation peak potential by 170 mV compared to the value of the MWCNT modified electrode with a peak potential of 180±10 mV (versus Ag/AgCl). The MWCNT/PT surface was further characterized using SEM and XPS methods, which indicated that a thin polymeric film had been formed on the electrode surface. The present work demonstrates the advantage of using PT as a platform that combines both the immobilization of alcohol dehydrogenase (ADH) and the mediation of NADH oxidation at a low overpotential essential to the design of high performance ethanol biosensors, all within an easily electropolymerizable film. The resulting biosensor displayed an ethanol sensitivity of 4.28±0.06 μA mM−1 cm−2, a linear range between 0.1 mM and 0.5 mM and a detection limit of 10 μM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏