首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method based on micellar electrokinetic capillary chromatography with electrochemical detection was developed for the determination of cytosine, 5-methylcytosine (5-MC), thymine, adenine, and guanine in the hydrolysates of DNA. The working electrode was fabricated in a novel self-positioning carbon disc electrode system that can align the capillary outlet with the working electrode without a three-dimensional micromanipulator. The five analytes could be well separated within 10 min in a 40 cm length capillary at a separation voltage of 9 kV in a 40 mmol/l borate buffer (pH 10.0) containing 100 mmol/l sodium dodecyl sulfate. Good linearity was observed between peak current and concentration of bases over three orders of magnitude with the detection limits (SIN=3) ranging from 1.28 x 10(-6) to 5.02 x 10(-6) mol/l. This proposed method demonstrated long-term stability and reproducibility with relative standard deviations of less than 5% for both migration time and peak current (n=7). It has been successfully applied to determine bases including 5-MC in the hydrolysates of fish sperm DNA, calf thymus DNA, and DNA isolated from spleen cells of female mice.  相似文献   

2.
Pesticide analysis by micellar electrokinetic capillary chromatography   总被引:2,自引:0,他引:2  
On-capillary sample concentration using sample stacking for the improvement of detection limits for various pesticides separated by micellar electrokinetic capillary chromatography was examined. The dependence of the stacking on different parameters was investigated. An approximately 30-fold preconcentration was achieved by applying sample stacking. Employing a two-step enrichment process (solid-phase extraction combined with sample stacking), detection limits were improved and the sample volume for SPE was reduced. In addition, the total time for the analysis was considerably reduced. Detection limits were between 0.01 and 0.1 ng/ml under these enrichment conditions.  相似文献   

3.
Shihabi ZK  Hinsdale ME 《Electrophoresis》2006,27(12):2458-2463
A simple and rapid ( approximately 4 min) method for the measurement of iohexol in serum for assessing the glomerular filtration rate is described. It is based on direct serum injection on the capillary by MEKC. The method is linear between 8 and 260 mg/L, with an RSD of peak height of 2.9%. Several simple steps have contributed to an improved daily precision, such as choosing a high pH buffer, increasing the SDS concentration, frequent standardization, and eliminating any sample pretreatment.  相似文献   

4.
The potential utility in pharmaceutical analysis of a capillary electrokinetic separation technique that employs a micellar "pseudo-stationary phase" is discussed and illustrated. Chromatograms of separations of vitamin metabolites and derivatized amino acids are presented to illustrate the high efficiency of the technique and the ability to simultaneously separate the charged and neutral components of pharmaceutical samples. The analytical characteristics of the technique and the importance of optimizing experimental parameters, such as surfactant concentration and capillary column diameter, are discussed and demonstrated with the aid of chromatograms.  相似文献   

5.
Separation of coumarins by micellar electrokinetic capillary chromatography   总被引:10,自引:0,他引:10  
Nine coumarins were successfully separated simultaneously using micellar electrokinetic capillary chromatography with 4-hydroxybenzoic acid as an internal standard. A carrier composed of buffer solution (20 mM sodium dodecyl sulfate-15 mM sodium borate-15 mM sodium dihydrogenphosphate)-acetonitrile (24:1) was found to be the most suitable electrolyte for this separation. The analysis time (22 min) was shorter than that using high-performance liquid chromatography (47 min). Contents of coumarins in the crude drug of Angelicae Tuhou Radix could be easily determined by the proposed method.  相似文献   

6.
7.
Summary Computer-assisted procedures for the one-parameter optimization of the surfactant concentration and the concentration of urea or D-glucose as modifiers in micellar electrokinetic capillary chromatography have been developed. These procedures permit a rapid optimization of one parameter on the basis of only two experiments. Predicted values are compared to empirically obtained optimum values. The influence of the modifier concentration on the critical micelle concentration of sodium dodecyl sulfate was experimentally determined in buffers commonly employed in micellar electrokinetic chromatography. The alteration of retention factors of solutes caused by the influence of urea addition on the critical micelle concentration of sodium dodecyl sulfate was calculated under the assumption of constant distribution coefficients and compared to experimentally obtained values. It was demonstrated that the addition of urea or of D-glucose does not alter the phase ratio substantially.  相似文献   

8.
Micellar electrokinetic capillary chromatography (MECC) based on sodium cholate (NaCh) and sodium dodecyl sulphate (SDS) was developed for the determination of aromatic amino acids and heterocyclic legume constituents. The influence of temperature, voltage, micellar system, pH, zwitterion and modifier concentrations in the buffer on migration times, peak areas, resolution and number of theoretical plates was investigated. This MECC method makes possible the sensitive determination of the individual compounds with detection limits in the picomole range. Up to 300 000 theoretical plates per metre of capillary were obtained together with satisfactory linearity and repeatability of the NaCh method. The applicability of MECC to samples prepared from plant material, following a fast and simple technique of isolation, purification and group separation, is illustrated by selected examples.  相似文献   

9.
Zhou XM  Liu JW  Zhang ME  Chen SJ 《Talanta》1998,46(4):757-760
The micellar electrokinetic capillary chromatography (MECC) method is reported for the separation of heparin, and for the possibility of direct determination of free heparin in plasma. The conditions for MECC were: pH 8.5, 25 mM sodium dodecyl sulfate (SDS), 25 mM borate buffer, with a 30 cmx50 mum ID fused-silica capillary. The sample was detected with a UV-detector at 270 nm with heparin as external standard. The recovery rate was 95.6-98.7%. This method was linear in the range 80-7000 U l(-1). The within-run and between-run relative standard deviations were lower than 3.1 and 4.5%, respectively. It is suggested that this MECC method may be used to determine blood samples containing high levels of heparin.  相似文献   

10.
Summary A method for the separation of a number of herbicides consisting of chlorophenoxy acids by micellar electrokinetic capillary chromatography (MECC) was developed. Sodium dodecyl sulphate (SDS), Brij 35, cetyltrimethylammonium bromide (CTAB) and methanol were introduced into the buffers to investigate their effects on the separation of the herbicides. SDS combined with Brij 35 as the micellar agent was found to provide the best overall separation of these components.  相似文献   

11.
Summary The separation of seven analogous anabolic steroids was studied by micellar electrokinetic capillary chromatography (MECC). The retention order was found to be dependent on polarity. All of these steroids were well separated by the addition of organic modifiers to the separation buffer. Of the organic modifiers tested, 1-propanol gave the best separation, better than methanol or acetonitrile.  相似文献   

12.
Seven water-soluble vitamins were determined simultaneously by micellar electrokinetic capillary chromatography with UV detection. All these compounds were separated from each other within ca. 22 min by using a carrier containing sodium dodecyl sulphate as the surfactant. On-column detection at 254 nm with ethyl p-aminobenzoate as the internal standard allowed sensitive, accurate and reproducible determination of these compounds. Five principal constituents of a vitamin injection were determined with relative standard deviations of less than 2.1%.  相似文献   

13.
A method for the simultaneous separation and determination of selected triazines, carbamates and phosphororganic compounds by micellar electrokinetic capillary electrophoresis has been developed. A mixture of nine pesticides has been investigated with respect to optimize their separation as a function of buffer and surfactant character and concentration, organic modifier and buffer pH. Quantitative aspects have been also examined. A determination of the compounds was possible up to the range of 0.1 mg/l. Best results have been achieved using a borate/SDS buffer, pH 8. At an applied voltage of 20 kV, the investigated compounds have been successfully resolved within 13 min.Dedicated to Professor Dr. K. Doerffel on the occasion of his 70th birthday  相似文献   

14.
Melin V  Perrett D 《Electrophoresis》2004,25(10-11):1503-1510
Separations of human urine by microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic capillary chromatography (MEKC) with respect to resolution, migration times and efficiencies were optimized and compared. The optimised MEEKC and MEKC methods were simple and fast, both of which are excellent characteristics for the complex separations required in clinical and biomedical studies. However, resolution in MEKC was significantly greater than in MEEKC although migration times were 30% faster for the optimised MEEKC method. In addition, a faster analysis method (short-end injection) specifically for routine screening purposes was also investigated. With both MEEKC and MEKC modes, this provided short separations (less than 4 min for urine) with no major compromise in resolution. In conclusion, we found that MEEKC offered no real advantage over MEKC for urine analysis.  相似文献   

15.
P. Gareil 《Chromatographia》1990,30(3-4):195-200
Summary This paper analyses the various modes of implementing micellar electrokinetic capillary chromatography (MECC) experimentally, according to the respective directions of the electro-osmotic flow and micelle and solute migrations. The importance of each mode is discussed with respect to separation time, separation time range, solute separability and elution order. The k and Rs expressions suitable for each mode are derived.  相似文献   

16.
The use of micellar electrokinetic capillary chromatography (MECC) for the analysis of the major nucleobases, nucleosides, and nucleotides, and their chemically modified derivatives, has been developed and refined. The dimensions of the separating capillaries, the composition of the buffering systems, and the conditions used for electrophoresis were investigated in order to obtain the best performance. Particular emphasis was placed on the identification of the physiological constituents of nucleic acids and their chemically modified analogs: in vitro studies on calf thymus DNA exposed to genotoxic agents have demonstrated that adducted bases and nucleolides can be identified by MECC.  相似文献   

17.
Fung YS  Mak JL 《Electrophoresis》2001,22(11):2260-2269
A new analytical procedure using a two-step sample preconcentration (solid-phase extraction (SPE) and field-amplified sample stacking) prior to separation by micellar electrokinetic capillary chromatography was developed for the determination of 14 pesticides such as aldicarb, carbofuran, isoproturon, chlorotoluron, metolachlor, mecoprop, dichlorprop, MCPA, 2,4-D, methoxychlor, TDE, DDT, dieldrin, and DDE in drinking water. Good recoveries of pesticides were obtained using SPE with sample pH adjusted to 2-3. Field-amplified sample stacking was found to give enrichment factors up to 30-fold preconcentration of various pesticides under reversed polarity at -2 kV for 50 s. The optimized background electrolyte (BGE) consisted of 50 mM sodium dodecyl sulfate (SDS), 10 mM borate buffer, 15 mM beta-cyclodextrin (beta-CD), and 22% acetonitrile at pH 9.6, running was under 25 kV and detection at 202 nm. Good linearity was obtained for all pesticides with detection limits down to 0.04-0.46 ng/mL and a working range of 0.1-40 ng/mL. The repeatabilities of migration time and peak area were satisfactory with relative standard deviations (RSDs) between 0.66 and 13.6% and 4.1 and 28%, respectively. All pesticides except dieldrin were found to be detected at concentrations at least tenfold lower than the World Health Organization (WHO) guideline values. The analytical procedure developed offers an economic method for fast screening of multiple pesticide residues in drinking water for health protection. It had been applied to determine carbofuran and MCPA in agricultural run-off water samples, giving satisfactory repeatabilities of 10 and 12%, respectively, with n=5 for the determination of pesticides in contaminated water samples.  相似文献   

18.
A fast and simple micellar electrokinetic capillary chromatographic method was developed for the analysis of piribedil in pharmaceutical formulations. The effects of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, applied voltage and injection time were investigated. Optimum results were obtained with a 50 mM borate buffer at pH 8.0 containing 50 mM SDS by using a fused silica capillary (50 m internal diameter, 72 cm effective length). The sample was injected hydrodynamically for 4 s at 50 mbar pressure and the applied voltage was +30 kV. The detection wavelength was set at 205 nm. Diflunisal was used as an internal standard. The analysis was performed at 25 °C and the total run time was 14 min. The method was suitably validated with respect to linearity range, limit of detection and quantification, precision, accuracy, specificity and robustness. The linear calibration range was 5–100 g mL–1 and the limit of detection was determined as 1 g mL–1. The method developed was successfully applied to the determination of piribedil in pharmaceutical formulations. The results were compared with a spectrophotometric method reported in the literature and no significant difference was found statistically.  相似文献   

19.
We studied the use of micellar electrokinetic capillary chromatography for separating eight penicillins. The method consists of (i) an electrophoretic separation based on micellar electrokinetic capillary chromatography, which uses sodium dodecyl sulfate (SDS) as surfactant; (ii) a sample stacking technique called reverse electrode polarity stacking mode (REPSM); and (iii) direct UV detection. The background electrolyte that gave complete separation contained 20 mM sodium borate buffer and 60 mM SDS. The sensitivity of the method was improved by an enrichment step that used on-column stacking. The limits of detection were at the microg.L(-1) level for the penicillins and did not detract from the peak resolution.  相似文献   

20.
胶束电动毛细管色谱法测定植物中的水杨酸   总被引:2,自引:1,他引:2  
建立了以胶束电动色谱为分离模式测定植物中水杨酸的新方法。在一定范围内,随着硼酸和甲醇浓度的升高,苯甲酸内标和水杨酸的分离度以近似线性关系升高;随缓冲液pH的升高分离度呈非线性升高;随十六烷基三甲基溴化铵浓度的升高分离度呈非线性下降。在优化的条件下,两可在12min内分离。测定了苹果和梨样品,并做了回收率试验,回收率在97.1%-102%之间。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号