首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
2.
A sensitive method for the selective determination of nitroglycerin at concentrations down to 50 pg/ml in human plasma is described. After the addition to plasma of a known amount of butane-1,2,4-triol trinitrate as internal standard, both compounds are extracted into hexane. Nitroglycerin is then quantitated by capillary gas chromatography with electron-capture detection.  相似文献   

3.
4.
5.
6.
P Pf?ffli  H Savolainen 《The Analyst》1991,116(12):1333-1336
A gas-chromatographic technique using 63Ni electron-capture detection was applied to the determination of 4-methyl-cis-hexahydrophthalic anhydride in the blood of workers occupationally exposed to this airborne agent. The detection limit was 0.24 nmol ml-1. For occupational exposure to between 0.14 and 0.31 mg m-3 of the anhydride, the anhydride concentration in the workers' blood samples ranged from 3.4 to 10.7 nmol ml-1. The results are consistent with earlier findings in animal exposure experiments and support the view that the hydrolysis of the anhydride in a biological medium is not spontaneous, but might be an enzyme-catalysed reaction. The resulting dicarboxylic acid is excreted by the kidneys without further conjugation reactions.  相似文献   

7.
A simple, rapid, and accurate method is described for the determination of residual fluvalinate in beeswax. The procedure consists of partitioning on a disposable column of diatomaceous earth (Extrelut), followed by chromatographic cleanup on a Florisil cartridge. The final extract is analyzed by capillary gas chromatography with electron-capture detection (GC-ECD). Briefly, wax samples were dissolved in n-hexane, and the solutions were sonicated and transferred to Extrelut columns. The fluvalinate was extracted with acetonitrile, and a portion of the extract was cleaned up on a Florisil cartridge. The fluvalinate was eluted with diethyl ether-n-hexane (1 + 1) and directly determined by GC-ECD. Recoveries from wax samples spiked at 5 fortification levels (100-1500 microg/kg) ranged from 77.4 to 87.3%, with coefficients of variation of 5.12-8.31%. The overall recovery of the method was 81.4 +/- 3.2%, and the limit of determination was 100 microg/kg.  相似文献   

8.
A sensitive, rapid, and simple multiresidue method for the simultaneous determination of 19 pesticides in different varieties of lettuce (Lactuca sativum) was developed. Lettuce samples were extracted by homogenization with acetone and partitioned into ethyl acetate-cyclohexane. Subsequent sample cleanup was not needed. Final determination was made by capillary gas chromatography (GC) with electron-capture detection (ECD). Confirmation analysis of pesticides was performed by GC coupled with mass spectrometry in the selected ion monitoring mode. The average recovery by the GC-ECD method obtained for these compounds varied from 66.4 to 119.2% with relative standard deviations < 7.7%. The GC-ECD method has good linearity, and the detection limit for the pesticides studied varied from 0.1 to 3.8 microg/kg. The proposed method was used to determine pesticide levels in different types of lettuce grown in soils from experimental fields.  相似文献   

9.
Tôei K  Shimoishi Y 《Talanta》1981,28(12):967-972
Formation of piazselenols by the reaction of Se(IV) with 1,2-diaminobenzene and its derivatives, followed by solvent extraction and gas chromatography with electron-capture detection, provides the most sensitive means of determining selenium. By suitable chemical manipulation, the method can be used for Se(-II), Se(O), Se(IV) and Se(VI). Applications to a wide variety of samples are reviewed.  相似文献   

10.
Comprehensive two-dimensional gas chromatography with micro electron-capture detection (GC x GC-microECD) has been evaluated for the enantioseparation of five chiral toxaphenes typically found in real-life samples (Parlar 26, 32, 40, 44 and 50). From the two enantioselective beta-cyclodextrin-based columns evaluated as first dimension column, BGB-176SE and BGB-172, the latter provided the best results and was further combined with three non-enantioselective columns in the second dimension: HT-8, BPX-50 and Supelcowax-10. The combination BGB-172 x BPX-50 was finally selected because it provided a complete separation among all enantiomers. A satisfactory repeatability and reproducibility of the retention times in both the first and the second dimension were observed for all target compounds (RSDs below 0.8%, n = 4). Linear responses in the tested range of 10-200 pg/microl and limits of detection in the range of 2-6 pg/microl were obtained. The repeatability and reproducibility at a concentration of 100 pg/microl, evaluated as the RSDs calculated for the enantiomeric fraction (EF), was better than 11% (n = 4) in all instances. The feasibility of the method developed for real-life analyses was illustrated by the determination of the enantiomeric ratios and concentration levels of the test compounds in four commercial fish oil samples. These results were compared to those obtained by heart-cut multidimensional gas chromatography using the same enantioselective column.  相似文献   

11.
A specific and sensitive method for the determination of unconjugated dehydroepiandrosterone in plasma is described. After extraction and purification of the extracts on a Celite column, the iodomethyldimethylsilyl ether derivative of dehydroepiandrosterone was isolated on an aluminium oxide column and assayed by gas chromatography with electron-capture detection. The method is sensitive: sample volumes of 0.5-1 ml are sufficient for the determination of dehydroepiandrosterone in plasma of normal male and female subjects aged 1-80 years. The assay is highly specific and has the potential to be used as a reference method for the determination of unconjugated dehydroepiandrosterone in biological samples.  相似文献   

12.
13.
14.
15.
We have developed an analytical method for the detection of halogenated alcohols in water with particular focus on 3-chloro-1,2-propanediol and 3-bromo-1,2-propanediol. In this method the target analytes are extracted from water, derivatized with heptafluorobutyric anhydride, and then analyzed with gas chromatography with electron-capture detection. The effects of water, pH and seawater constituents on the method were investigated. Method detection limits for a 5 ml aqueous sample ranged from 0.14 microg l(-1) for 2-bromo-1,3-propanediol to 1.7 microg l(-1) for 1,3-dichloro-2-propanol (1,3DCP).  相似文献   

16.
17.
18.
19.
20.