首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
建立了快速溶剂萃取(ASE)-气相色谱-串联质谱(GC-MS/MS)分析海洋沉积物中16种多环芳烃(PAHs)的分析方法。样品由正己烷-丙酮(1∶1,v/v)溶液萃取,经无水硫酸钠脱水、氮吹浓缩后,采用硅胶固相萃取小柱进行净化,然后经HP-5MS色谱柱(30 m×0.25 mm×0.25 μm)分离,在电子轰击电离源下以多反应监测(MRM)模式进行检测,内标法定量。分析结果表明,16种PAHs在0.01~1.00 mg/L范围内线性关系良好,相关系数(R)大于0.997;目标物的加标回收率为75.8%~97.8%;日内与日间精密度(RSD)均小于10%。当取样量为20.0 g时,16种PAHs的方法检出限为0.048~0.234 μg/kg。该法快速、准确、稳定,能够满足海洋沉积物中痕量PAHs的测定。  相似文献   

2.
An accurate and reliable method for determining polycyclic aromatic hydrocarbons (PAHs) in atmospheric aerosols is described. This optimised gas chromatography-mass spectrometry (GC-MS) method permits a wide range of concentrations to be analysed without the influence of interferences.Pre-treatment comparison of four kinds of aerosol collector filters determined that quartz and glass fibre filters were the most suitable. Solvents like cyclohexane, toluene, acetonitrile and dichloromethane were evaluated for their PAH-extraction capacity. Ultrasonic extraction using CH2Cl2 was selected because it is rapid and easy; moreover, this solvent increases the sample-throughput capacity.PAH compounds were quantitatively collected and ultrasonically extracted twice using 15 mL of CH2Cl2 for 15 min for each replicate. Rotavapor concentration, fractionation and dissolution were also optimised.A certified standard mixture (16 EPA PAHs), a deuterated compound and precision recovery assays were used for validating the proposed methodology. Adequate analytical parameters were obtained. Detection limits were (1.6-26.3) × 10−5 ng and quantification limits were (5.2-87.6) × 10−5 ng.Analysis of the environmental samples detected 4-10 EPA list PAH compounds. In addition, 2-11 tentative compounds were found, and their molecular structures were described for the first time.Our study of both Youden method and the standard addition method has shown that the proposed determination of PAHs in environmental samples is free of systematic errors.In conclusion, this unbiased methodology improves the identification and quantification of PAH compounds. High sensitivity as well as acceptable detection and quantification limits were obtained for the environmental applications.  相似文献   

3.
The atmospheric levels of polycyclic aromatic hydrocarbons (PAHs) in atmospheric samples taken at two urban sites and two sites near industrial areas of the Tarragona region (Catalonia, Spain), where one of the most important petrochemical complexes in the south of Europe is located, were determined. Gas and particulate phase of air were separately sampled and analysed. Concentrations of 16 PAHs studied ranged from 4.2 to 22.5 ng m?3, with predominant levels of PAHs appearing in gas phase (~90% of total PAHs). In all samples, the most abundant compounds were phenanthrene, with a contribution to total PAHs between 32 and 44%, followed by naphthalene, fluorene and fluoranthene (contribution range: 10–22%). The levels of total PAHs, expressed as benzo[a]pyrene toxic equivalent factors (BaPTEF), were lower than 0.06 ng m?3.  相似文献   

4.
Abstract

The atmospheric transport of organic pollutants over long distances and their effect on the biological cycles of the sea are two major questions of concern in environmental chemistry. These processes are of particular importance in the Mediterranean Sea because of its semi-enclosed characteristics, which determine the accumulation of the pollutants entering into the system.

In order to get some insight into these processes a project (PHYCEMED), was developed for the evaluation of the atmospheric budget of organic and inorganic substances in the Western Mediterranean and for the investigation of the exchange mechanisms of these materials across the air/sea interface.

A high volume air sampling system including a cascade impactor was placed on board of the R/V le Suroit for collecting the acrosols along several transects parallel to the French, Spanish and North-African coasts, facing areas of different population densities and industrial activities. The cruise was realised on October 1983 and the particulate material was fractionated into the following sizes: 7.2, 3.0, 1.5, 0.96, and 0.03 μm. Quantitative and qualitative analyses of the aliphatic and the aromatic hydrocarbons present in these fractions were performed by high resolution gas chromatography and gas chromatography-mass spectrometry.

Total non-aromatic hydrocarbon concentrations are in the range 30-57 ng/m3 (10-14ng/m3 for n-alkanes). The distribution of n-alkanes indicates that most of the aerosol mass is associated with small particles < 1 μm.Polycyclic aromatic hydrocarbons are identified from phenanthrene to benzo(ghi)perylene with fluoranthene and pyrene as dominant compounds. Concentrations for individual PAH vary in the range 4.1 pg/m3 for benzo(a)anthracene up to 100 pg/m3 for fluoranthene. The evaluation of different contributions such as land plant waxes or soil sources and various anthropogenic sources is discussed from n-alkanes and PAH distribution patterns.  相似文献   

5.
This paper describes the development and optimization, by using multivariate analysis, of a GC-MS-SIM method for evaluation of the 16 polyaromatic hydrocarbons considered as priority pollutants in atmospheric particulate material by the US EPA. In order to assure an adequate separation in the shortest analysis time, a multivariate design was used to set the conditions of the oven temperature program. The optimization process was carried out using factorial fractional design and Box-Behnken design. The following factors were evaluated: initial temperature, temperature rate #1, intermediary temperature, temperature rate #2, and final temperature. The optimized conditions were set at: 70 degrees C (2 min) --> 200 degrees C (30 degrees C/min, 5 min) --> 300 degrees C (5 degrees C/min, 1.67 min). Moreover, we have also optimized the injector temperature as 310 degrees C and sampling time as 0.8 min. The total analysis time was 33 min. Validation of GC-MS-SIM yielded satisfactory results for repetitivity of the detector response and retention times, and linearity of calibration curves. LOD were established as 0.13-0.34 ng/mL (peak area) and 0.18-0.72 ng/mL (peak height). The method has been shown to be appropriate for the analysis of samples of atmospheric particulate material and/or other environmental matrices.  相似文献   

6.
Polycyclic aromatic hydrocarbons (PAHs) are a large category of ubiquitous persistent environmental pollutants, some of them have strong carcinogenicity to human and animals. These pollutants can easily enter the river through multiple ways including rainfall, dry deposition and water washout, and deposit in the sediment. However, it is easy for them to re-enter the river water and pollute water sources, as well as aquatic animals and plants, bringing potential harm to human health. Therefore, it is requisite to accurately analyze the PAHs in sediment. In this review, the analytical methods of PAHs in sediment, focused on the methods of sample extraction, purification, concentration and determination, are summarized.  相似文献   

7.
The secondary ion mass spectrometry method (ToF-SIMS) has been applied to the analysis of some mineral and organic species on the surface layers of airborne urban particulates. Particulate matter was collected on aluminum sheets of the 8-stage Anderson type cascade impactor from three different sampling sites in the city of Lodz, Poland, which were different in terms of aerosol source apportionment. The obtained results show that vehicle combustion products occur mainly in fine fraction with aerodynamic diameters below 1μm. The main contribution to the mineral components comes from direct and traffic related soil resuspension.   相似文献   

8.
A collaborative study on the analysis for 15 + 1 EU priority PAHs in edible oils was organised to investigate the state-of-the-art of respective analytical methods. Three spiked vegetable oils, one contaminated native sunflower oil, and one standard solution were investigated in this study. The results of 52 laboratories using either high-performance liquid chromatography with fluorescence detection or gas chromatography with mass-selective detectors were evaluated by application of robust statistics. About 95% of the laboratories were able to quantify benzo[a]pyrene together with five other PAHs included in the commonly known list of 16 US-EPA PAHs. About 80% of the participants also quantified seven additional PAHs in most samples, two of which were benzo[b]fluoranthene and benzo[k]fluoranthene, which were also known from the EPA list. Only about 50% of the participants quantified cyclopenta[cd]pyrene, benzo[j]fluoranthene, and benzo[c]fluorene. The robust relative standard deviations of the submitted results without discrimination between the methods applied ranged between 100% for 5-methylchrysene in spiked olive oil and 11% for the same analyte in spiked sunflower oil. The results clearly showed that for these analytes the methods of analysis are not yet well established in European laboratories, and more collaborative trials are needed to promote further development and to improve the performances of the respective methods.  相似文献   

9.
Polycyclic aromatic hydrocarbons (PAHs) are a large class of organic compounds. It has been established that the main source of exposure to these compounds for human beings is through food, particularly fats and oils, due to the lipophilic nature of these polycyclic compounds. The aim of this work was to optimise and validate a method involving SPE and HPLC for rapid determination of the 16 European Union (EU) priority PAHs (required by the Recommendation 2005/108/EC) in vegetable oils. Two spectrofluorometric detectors and a UV-Visible detector in series were used to identify and quantify the target compounds. Linearity, recoveries, LOD, and LOQ were found to be in agreement with the performance criteria for benzo[a]pyrene (BaP) analysis as required by the Commission Directive 2005/10/EC, and satisfactory for all the compounds of interest, except for cyclopenta[c,d]pyrene, which presented a very low signal in the UV. Optimised chromatographic conditions for the separation of 25 PAHs, comprising both EPA and EU priority PAHs plus benzo[e]pyrene and benzo[b]chrysene, have been also proposed.  相似文献   

10.
Two freshwater sediments certified reference materials (CRMs) for 16 polycyclic aromatic hydrocarbons (PAHs) have been developed by the Institute for Environmental Reference Materials (IERM) of Ministry of Environmental Protection (MEP) in China. The methodology for preparing the CRMs of PAHs in sediments is described in this paper. The collected natural sediment samples were air-dried, ground, homogenised, packed, sterilised and tested on stability and homogeneity. Homogeneity results showed that the between-unit variation was confirmed to be below 4.5% for each compound. Stability was assessed after storage of samples for 16 months at temperature less than 30°C and in shade. The certification of the natural sediment matrix CRMs for PAHs was based on the agreement of results using different analytical techniques including gas chromatography/mass spectrometry (GC/MS) and reversed-phase liquid chromatography (LC) by no less than eight collaborating laboratories including IERM. Results of the homogeneity showed that the calculated ubb′ was 0.9–2.5% for environmental river standard-4 (ERS-4) and 9–2.3% for environmental lake standard-1 (ELS-1), whereas stability results of total 16 PAHs indicated that the calculated urel,lts was 4.2% for ERS-4 and 2.2% for ELS-1. Certified values of 16 PAHs in ERS-4 varied from 8.5 to 167 μg/kg and ranged from 0.036 to 2.8 mg/kg in ELS-1.The good comparability, together with the independent confirmation of the assigned mass fraction by using different methods, confirmed that the CRMs are suitable for the method validation and quality control in soil or sediments analysis.  相似文献   

11.
北京地区大气颗粒物中不同功能区多环芳烃的分布特征   总被引:1,自引:0,他引:1  
用撞击式分级采样器同步采集了北京市城乡结合部、郊区的2003年四个季节的不同粒径大气颗粒物样品,用气相色谱-质谱分析了其中的多环芳烃。两个功能区的PAHs总质量浓度分布趋势均为:冬季>秋季>春季>夏季;不同环数PAHs在不同粒径颗粒物中的分配比例比较显示,粗颗粒物中2 环或3环PAHs的分配比例比其在高环PAHs的比例要大。  相似文献   

12.
The occurrence of polycyclic aromatic hydrocarbons (PAHs) in nine edible oils of three categories of oil samples, such as soy bean oil, mustard oil and coconut oil, has been studied to determine the contamination degree of this type of oil samples. Eight major carcinogenic polycyclic aromatic hydrocarbons (PAHs), such as naphthalene, anthracene, phenanthrene, fluorene, pyrene, crysene, benzo(a)pyrene and benzo(a)anthracene, were identified and quantified in the extract of edible oils collected from Bangladeshi Markets by gas chromatography and mass spectroscopy. All of the carcinogenic PAHs are not present in the edible oils. A few of the carcinogenic PAHs are present in the oils but it is within the permissible limit. The results for the recoveries of naphthalene, fluorene, phenanthrene, anthracene, pyrene, crysene, benzo(a)anthracene and benzo(a)pyrene were in the range of 56–84%. The limit of detection (LOD) of the GC–MS method, established at signals three times that of the noise for naphthalene, fluorene, phenanthrene, anthracene, pyrene, crysene, benzo(a)anthracene and benzo(a)pyrene, was 2.0–2.5 ng, respectively.  相似文献   

13.
Polycyclic aromatic hydrocarbons (PAHs) are frequently encountered in the environment and may pose health concerns due to their carcinogenicity. A commercial enzyme-linked immunosorbent assay (ELISA), was evaluated as a screening method for monitoring PAHs at contaminated sites. The ELISA was a carcinogenic PAH (C-PAH) RaPID assay testing kit that cross-reacts with several PAHs and utilizes benzo[a]pyrene (BaP) as a calibrator. Soil samples were extracted with 50% acetone in dichloromethane (DCM) for analysis by ELISA and gas chromatography-mass spectrometry (GC-MS). The overall method precision was within ±30% for ELISA and within ±20% for GC-MS. Recovery data for spiked soils ranged from 46 to 140% for BaP as determined by ELISA. Recoveries data of the GC-MS surrogate standards, 2-fluorobiphenyl and chrysene, were greater than 70%. The GC-MS procedure detected a total of 19 priority PAHs (2-6-ring PAHs) including seven probable human carcinogens (4-6-ring B2-PAHs). The ELISA results were compared to GC-MS summation results for the total 19 target PAHs as well as for the subset of the seven B2-PAH compounds. For all soil samples, the PAH concentrations derived from ELISA were greater than the sum of B2-PAH concentrations obtained by GC-MS. ELISA determinations were also frequently greater than the results obtained by GC-MS for the total 19 PAH compounds. This discrepancy can be expected, since the ELISA is a screening assay for the detection of several related PAHs while the GC-MS procedure detects priority PAH compounds. Thus, only a subset of PAHs (e.g. 19 PAHs) in the soil samples were measured by GC-MS while additional PAHs, including alkylated PAHs, and PAH derivatives have been demonstrated to be cross-reactive in the C-PAH ELISA. Results of paired tests show that the PAH data from ELISA and GC-MS methods are significantly different (P<0.001), but highly correlated. The ELISA data had a strong positive relationship with the GC-MS summation data for the B2-PAHs as well as for the 19 PAHs targeted by the GC-MS method. Results indicate that the ELISA may be useful as a broad screen for monitoring PAHs in environmental samples.  相似文献   

14.
15.
王美飞  杨丽莉  胡恩宇 《色谱》2017,35(6):669-673
建立了一种微波提取-高效液相色谱法测定大气颗粒物中多环芳烃的方法。吸附有颗粒物的超细玻璃纤维/石英纤维滤膜用正己烷/丙酮(1∶1,v/v)混合溶剂经微波提取,提取液用弗罗里硅土柱净化,经浓缩定容后,采用液相色谱法-二极管阵列(PDA)-荧光双检测器测定。目标化合物在20.0~500μg/L范围内线性良好,相关系数不小于0.996 0。空白膜加标结果显示,目标化合物的回收率在56.3%~101%之间。该法已运用于南京市大气颗粒物中多环芳烃分布的调查研究。  相似文献   

16.
王欣欣  刘庆阳  刘艳菊  谷学新 《色谱》2010,28(9):849-853
建立了二级热脱附-气相色谱-质谱联用技术测定大气可吸入颗粒物PM10中16种多环芳烃的分析方法。对二级热脱附和色谱-质谱条件进行了优化。实验结果表明,方法的检出限为0.14~0.42 ng/m3,平均加标回收率为52.7%~97.9%,相对标准偏差(RSD)为8.0%~18.4%。与传统方法相比,该方法的样品前处理时间短、有机溶剂的使用量少,是对人体及环境友善的检测技术。该方法已应用于32份实际大气颗粒物样品的分析。  相似文献   

17.
Costa JC  Sant'ana AC  Corio P  Temperini ML 《Talanta》2006,70(5):1011-1016
The use of surface-enhanced Raman spectroscopy (SERS) for trace determination of polycyclic aromatic hydrocarbons (PAHs) is described. This paper focuses on the development of SERS-active substrates that are specific for the characterization and spectroscopic study of PAHs. The SERS-active substrates are based on thin gold films evaporated on a glass surface previously treated with a mercaptoalkylsilane. SERS of PAHs was investigated over uncoated gold island films and over such films coated with a self-assembled monolayer (SAM) of 1-propanethiol. Adsorption of PAHs on a plain SERS-active Au-film led to a surface-induced decomposition of PAHs, due to catalytic properties of nanostructured gold. Thus, the functionalization of the SERS-active substrates by means of SAM was done aiming at a specific chemical interaction toward PAHs. Thus, in addition to preventing decomposition of the PAHs, the coating also concentrates the hydrophobic PAHs close enough to the SERS-active interface. Results show that high sensitivity, SERS-active nanostructured gold substrates that show selectivity towards PAHs were obtained, with the following properties: strong intensification of the Raman signal, reproducibility, and stability over time. The employed methodology enables the observation of excellent Raman spectra of PAHs in aqueous environment at ppm levels.  相似文献   

18.
A novel partitioning collection device comprising a glass cartridge packed with poly(dimethylsiloxane)‐coated macroporous silica particles was developed for the precise quantification of polycyclic aromatic hydrocarbons in air. The analyte collection and elution performances achieved using different amounts of poly(dimethylsiloxane) coating were quantitatively evaluated. The sample retention power increased with increasing the coating, and more than 250 L of air could be collected without analyte breakthrough at a sampling temperature of 35°C. During the air collection, the moisture in the air was not retained on the particles due to the hydrophobic surface of the sorbent. A complete and rapid elution of the collected analytes from the device was accomplished by the passage of only 10 mL of acetone with ultrasonication for 1 min. The proposed method was successfully applied for the determination of airborne polycyclic aromatic hydrocarbons in tunnel air.  相似文献   

19.
张小涛  张丽  阮艺斌  王维维  姬厚伟  万强  林福呈  刘剑 《色谱》2017,35(10):1105-1110
建立了气相色谱-串联质谱同时检测卷烟滤嘴中15种多环芳烃的方法。卷烟滤嘴用二氯甲烷振荡萃取后,经0.22μm有机相滤膜过滤,采用DB-5MS色谱柱(30 m×0.25 mm,0.25μm)进行分离,电子轰击源、正离子模式下以多反应监测模式进行检测,内标法进行定量。15种多环芳烃(苊烯、苊、芴、菲、蒽、荧蒽、芘、苯并[a]蒽、屈、苯并[b]荧蒽、苯并[k]荧蒽、苯并[a]芘、二苯并[a,h]蒽、苯并[g,h,i]苝和茚并[1,2,3-c,d]芘)的线性关系良好,相关系数(R~2)为0.991 4~0.999 9。15种多环芳烃在低、中、高3个添加水平下的平均回收率为81.6%~111.2%;除了芴在低添加水平时相对标准偏差为19.2%外,其他相对标准偏差均小于16%。15种多环芳烃的检出限为0.02~0.24 ng/滤嘴,定量限为0.04~0.80 ng/滤嘴。方法前处理简便,具有快速、准确、灵敏度高及重复性好的优点,适用于卷烟滤嘴中多环芳烃的分析。  相似文献   

20.
Focused ultrasonic-assisted extraction (FUSE) is a new and particular technique based on the cavitation effect. In this work, the focused ultrasound assisted extraction was studied and developed for the extraction of polycyclic aromatic hydrocarbons from marine sediments and mussel tissues. The variables influencing the extraction (amplitude of the ultrasound pulse, the extraction time and the solvent) were studied by a full factorial design and a central composite design. As a result, flat response surfaces were obtained and the most convenient conditions were 45% of ultrasound amplitude, 120 s of extraction time and 5 mL of acetone. Both accuracy and precision of the method were evaluated by means of two certified reference materials (marine sediment and mussel tissue) and the results were also compared to those obtained by microwave assisted extraction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号