首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
The bottom-up strategy for proteome analysis typically employs a multistep sample preparation workflow that suffers from being time-consuming and sample loss or contamination caused by the off-line manual operation.Herein,we developed a hollow fibre membrane(HFM)-aided fully automated sample treatment(FAST)method.Due to the confinement effects of HFMs and the immobilized enzymatic reactor,the proteome samples could be denatured,reduced,desalted and digested within 8–20 min via the one-stop service.This method also showed superiority in trace sample analysis.In one and half hours,we could identify about 1,600 protein groups for 500 HeLa cells as the starting materials,1.5–8 times more than those obtained by previously reported methods.Through the on-line combination of FAST with nano-liquid chromatography-electrospray ionization tandem mass spectrometry(nanoLC-ESI-MS/MS),we further established a fully integrated platform for label-free quantification of proteome with high reproducibility and precision.Collectively,FAST presented here represents a major advance in the high throughput sample treatment and quantitative analysis of proteomes.  相似文献   

2.
The dissociation of protein ions (5-30 kDa) as a function of charge state has been explored in order to suggest the optimal charge state range for top-down sequencing. Proteins were generated under denaturing conditions and their charge states were modified via ion/ion proton transfer reactions prior to dissociation. Electron transfer dissociation (ETD) data suggested optimal sequence coverage for charge states in the m/z range from 700 to 950 while limited sequence coverage was noted when the precursor m/z was above 1000. Sequence coverage from ETD data was found to be dependent on protein size, with smaller proteins having better sequence coverage. An observed depletion in sequence-related information was mainly attributed to limited instrument (ion trap) performance (m/z range and resolution). For a combined ETD/collision-induced dissociation (CID) approach it is difficult to propose an optimal m/z range since good sequence coverage for CID is at intermediate charge states and the optimal m/z range increases with protein size. When only one charge state can be analysed in a combined ETD/CID approach, a range around 950 m/z is suggested as a starting point. Alternatively, two charge states should be explored, each optimal for either ETD or CID. Overall, these suggestions should be useful to achieve enhanced characterisation of smaller proteins/large protein fragments (generated from denaturing solutions) in minimal analysis times.  相似文献   

3.
4.
Chondroitin/dermatan sulfate (CS/DS) chain of decorin (DCN) from human skin fibroblasts (HSk) was released by reductive β-elimination reaction and digested with chondroitin AC I lyase. Enzymatic hydrolysis mixture of CS/DS chains was separated by size-exclusion chromatography (SEC). Collected octasaccharide fraction was subjected to fully automated chip-based nanoelectrospray (nanoESI) quadrupole time-of-flight (QTOF) MS and tandem MS (MS/MS). MS of human skin fibroblasts DCN CS/DS displayed a high complexity due to the large variety of glycoforms, which under chip-nanoESI MS readily ionized to form multiply charged ions. Except for the regularly tetrasulfated octasaccharide, the investigated fraction contained four additional octasaccharides of atypical sulfation status. Two new oversulfated glycoforms and two undersulfated species were identified. Remarkably, the series of decasaccharides discovered in the same SEC pool was found to encompass a trisulfated and a novel hexasulfated [4,5-Δ-GlcAGalNAc(IdoAGalNAc)?] species. MS/MS by collision-induced dissociation (CID) on the [M-4H]? ion corresponding to the previously not reported [4,5-Δ-GlcAGalNAc(IdoAGalNAc)?](5S) corroborated for a novel motif in which three N-acetylgalactosamine (GalNAc) moieties are monosulfated, 4,5-Δ-GlcA and the first IdoA from the non-reducing end bear one sulfate group each, while the second N-acetylgalactosamine from the reducing end is unsulfated.  相似文献   

5.
Electron-transfer dissociation (ETD) is evaluated as a technique to provide local information on higher order structure and dynamics of a whole protein molecule. Isotopic labeling of highly flexible segments of a model 18 kDa protein is carried out in solution under mildly denaturing conditions by means of hydrogen/deuterium exchange (HDX), followed by transfer of intact protein ions to the gas phase by means of electrospray ionization, and mass-selection of a precursor ion for subsequent reactions with fluoranthene radical anions. The ETD process gives rise to abundant fragment ions, whose deuterium content can be measured as a function of duration of the HDX reaction in solution. No backbone protection is detected for all protein segments spanning the 25-residue long N-terminal part of the protein, which is known to lack structure in solution. At the same time, noticeable protection is evident for segments representing the structured regions of the protein. The results of this work suggest that ETD of intact protein ions is not accompanied by detectable hydrogen scrambling and can be used in tandem with HDX to probe protein conformation in solution.  相似文献   

6.
Electron transfer dissociation (ETD) has become increasingly used in proteomic analyses due to its complementarity to collision-activated dissociation (CAD) and its ability to sequence peptides with post-translation modifications (PTMs). It was previously unknown, however, whether ETD would be compatible with a commonly employed quantification technique, isobaric tags for relative and absolute quantification (iTRAQ), since the fragmentation mechanisms and pathways of ETD differ significantly from CAD. We demonstrate here that ETD of iTRAQ labeled peptides produces c- and z -type fragment ions as well as reporter ions that are unique from those produced by CAD. Exact molecular formulas of product ions were determined by ETD fragmentation of iTRAQ-labeled synthetic peptides followed by high mass accuracy orbitrap mass analysis. These experiments revealed that ETD cleavage of the N-C(alpha) bond of the iTRAQ tag results in fragment ions that could be used for quantification. Synthetic peptide work demonstrates that these fragment ions provide up to three channels of quantification and that the quality is similar to that provided by beam-type CAD. Protein standards were used to evaluate peptide and protein quantification of iTRAQ labeling in conjunction with ETD, beam-type CAD, and pulsed Q dissociation (PQD) on a hybrid ion trap-orbitrap mass spectrometer. For reporter ion intensities above a certain threshold all three strategies provided reliable peptide quantification (average error < 10%). Approximately 36%, 8%, and 16% of scans identified fall below this threshold for ETD, HCD, and PQD, respectively. At the protein level, average errors were 2.3%, 1.7%, and 3.6% for ETD, HCD, and PQD, respectively.  相似文献   

7.
The use of electron-transfer dissociation as an alternative peptide ion activation method for generation of protein sequence information is examined here in comparison with the conventional method of choice, collisionally activated dissociation, using a linear ion trapping instrument. Direct comparability between collisionally and electron-transfer-activated product ion data were ensured by employing an activation-switching method during acquisition, sequentially activating precisely the same precursor ion species with each fragmentation method in turn. Sequest (Thermo Fisher Scientific, San Jose, CA) searching of product ion data generated an overlapping yet distinct pool of polypeptide identifications from the products of collisional and electron-transfer-mediated activation products. To provide a highly confident set of protein recognitions, identification data were filtered using parameters that achieved a peptide false discovery rate of 1%, with two or more independent peptide assignments required for each protein. The use of electron transfer dissociation (ETD) has allowed us to identify additional peptides where the quality of product ion data generated by collisionally activated dissociation (CAD) was insufficient to infer peptide sequence. Thus, a combined ETD/CAD approach leads to the recognition of more peptides and proteins than are achieved using peptide analysis by CAD- or ETD-based tandem mass spectrometry alone.  相似文献   

8.
This work presents a simple method for obtaining homogeneous sample surfaces in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the automated analysis of peptides and proteins. The sample preparation method is based on applying the sample/matrix mixture onto a pre-deposited highly diluted matrix spot. The pre-deposited crystals act as seeds for the new sample containing crystals which become much smaller in size and more evenly distributed than with conventional methods. This 'seed-layer' method was developed, optimised and compared with the dried-droplet method using peptides and proteins in the 1000-20,000 Da range. The seed-layer method increases the surface homogeneity, spot to spot reproducibility and sample washability as compared with the commonly used dried-droplet method. This methodology is applicable to alpha-cyanohydroxycinnamic acid, sinapinic acid and ferulic acid, which all form homogeneous crystal surfaces. Within-spot variation and between-spot variation was investigated using statistics at a 95% confidence level (n = 36). The statistical values were generated from more than 5000 data points collected from 500 spectra. More than 90% of the sample locations results in high intensity spectra with relatively low standard deviations (RSDs). Typically obtained data showed an RSD of 19-35% within a sample spot as well as in-between spots for proteins, and an RSD of < or = 50% for peptides. Linear calibration curves were obtained within one order of magnitude using internal calibration with a point-RSD of 3% (n = 10). The sample homogeneity allows mass spectra (average of 16 laser shots) to be obtained on each individual sample within 15 sec, whereby a 100 spot target plate can be run in 25 min. High density target plates using the seed-layer method were prepared by spotting approximately 100 picoliter droplets onto the target, resulting in sample spots < or = 500 microns in diameter using a flow-through piezo-electric micro-dispenser. By using this automated sample preparation step lower standard deviations are obtained in comparison to manually prepared samples.  相似文献   

9.
Coppola S  Vespini V  Grilli S  Ferraro P 《Lab on a chip》2011,11(19):3294-3298
Destabilization of liquid film by electro-hydro-dynamics (EHD) pressure is achieved through the pyroelectric effect on a polar dielectric crystal. We show that by destabilizing the liquid film, periodical self-assembled multi-jets are obtained. The multi-jets operate simultaneously and could be exploited to dispense liquids with nanolitre drops. Such multiple self-assembled liquid jets have significant potential applicability for high-throughput liquid transfer by this novel pyro-EHD ink-jet approach. Since the method avoids the use of nozzles and electrodes, it is especially suitable for highly viscous liquids. Here we present and discuss the new multi-jet process and the results obtained with a liquid polymer (PDMS).  相似文献   

10.
This paper reports a novel evaporator and its integration with an automated sample handling system to create a high throughput evaporation platform. The Vaportec V-10 evaporator uses a high speed rotation motor ( approximately 6000 rpm) to spin the vial containing a sample, creating a thin film of solvent which can be readily evaporated by the application of heat to the vial, while the consequent centrifugal force prevents "bumping". An intelligent algorithm controls pressure and temperature for optimum solvent removal conditions and end of run detection, critical for automation. The system allows the option of evaporation directly from a sample source vial, or alternatively, integrated liquid handling facilities provide the capability of transferring samples portionwise from a (large) source vial or bottle to a (small) daughter container, enabling efficient sample reformatting, with minimum user intervention. The open access system makes significant advances over current vacuum centrifugal evaporators in terms of evaporation rate and ease of automation. The evaporator's main features, the integration of robotics to provide automation, and examples of evaporation rates of a wide range of solvents from a variety of containers are described.  相似文献   

11.
One of the most commonly performed in vitro ADME assays during the lead generation and lead optimization stage of drug discovery is metabolic stability evaluation. Metabolic stability is typically assessed in liver microsomes, which contain Phase I metabolizing enzymes, mainly cytochrome P450 enzymes (CYPs). The amount of parent drug metabolized by these CYPs is determined by LC/MS/MS. The metabolic stability data are typically used to rank order compounds for in vivo evaluation. We describe a streamlined and intelligent workflow for the metabolic stability assay that permits high throughput analyses to be carried out while maintaining the standard of high quality. This is accomplished in the following ways: a novel post-incubation pooling strategy based on c Log D3.0 values, coupled with ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS), enables sample analysis times to be reduced significantly while ensuring adequate chromatographic separation of compounds within a group, so as to reduce the likelihood of compound interference. Assay quality and fast turnaround of data reports is ensured by performing automated real-time intelligent re-analysis of discrete samples for compounds that do not pass user-definable criteria during the pooling analysis. Intelligent, user-independent data acquisition and data evaluation are accomplished via a custom visual basic program that ties together every step in the workflow, including cassette compound selection, compound incubation, compound optimization, sample analysis and re-analysis (when appropriate), data processing, data quality evaluation, and database upload. The workflow greatly reduces labor and improves data turnaround time while maintaining high data quality.  相似文献   

12.
We describe a fully automated high performance liquid chromatography 9.4 tesla Fourier transform ion resonance cyclotron (FTICR) mass spectrometer system designed for proteomics research. A synergistic suite of ion introduction and manipulation technologies were developed and integrated as a high-performance front-end to a commercial Bruker Daltonics FTICR instrument. The developments incorporated included a dual-ESI-emitter ion source; a dual-channel electrodynamic ion funnel; tandem quadrupoles for collisional cooling and focusing, ion selection, and ion accumulation, and served to significantly improve the sensitivity, dynamic range, and mass measurement accuracy of the mass spectrometer. In addition, a novel technique for accumulating ions in the ICR cell was developed that improved both resolution and mass measurement accuracy. A new calibration methodology is also described where calibrant ions are introduced and controlled via a separate channel of the dual-channel ion funnel, allowing calibrant species to be introduced to sample spectra on a real-time basis, if needed. We also report on overall instrument automation developments that facilitate high-throughput and unattended operation. These included an automated version of the previously reported very high resolution, high pressure reversed phase gradient capillary liquid chromatography (LC) system as the separations component. A commercial autosampler was integrated to facilitate 24 h/day operation. Unattended operation of the instrument revealed exceptional overall performance: Reproducibility (1-5% deviation in uncorrected elution times), repeatability (<20% deviation in detected abundances for more abundant peptides from the same aliquot analyzed a few weeks apart), and robustness (high-throughput operation for 5 months without significant downtime). When combined with modulated-ion-energy gated trapping, the dynamic calibration of FTICR mass spectra provided decreased mass measurement errors for peptide identifications in conjunction with high resolution capillary LC separations over a dynamic range of peptide peak intensities for each spectrum of 10(3), and >10(5) for peptide abundances in the overall separation.  相似文献   

13.
Shan Y  Shi X  Dou A  Zou C  He H  Yang Q  Zhao S  Lu X  Xu G 《Journal of chromatography. A》2011,1218(13):1743-1748
Microcystins and nodularins are cyclic peptide hepatotoxins and tumour promoters from cyanobacteria. The present study describes the development, validation and practical application of a fully automated analytical method based on on-line micro solid-phase extraction-capillary liquid chromatography-tandem mass spectrometry for the simultaneous determination of seven microcystins and nodularin-R in tap water and lake water. Aliquots of just 100 μL of water samples are sufficient for the detection and quantification of all eight toxins. Selected reaction monitoring was used to obtain the highest sensitivity. Good linear calibrations were obtained for microcystins (50-2000ng/L) and nodularin-R (25-1000 ng/L) in spiked tap water and lake water samples. Excellent interday and intraday repeatability were achieved for eight toxins with relative standard deviation less than 15.7% in three different concentrations. Acceptable recoveries were achieved in the three concentrations with both tap water matrix and lake water matrix and no significant matrix effect was found in tap water and lake water except for microcystin-RR. The limits of detection (signal to noise ratio=3) of toxins were lower than 56.6 ng/L which is far below the 1 μg/L defined by the World Health Organization provisional guideline for microcystin-LR. Finally, this method was successfully applied to lake water samples from Tai lake and proved to be useful for water quality monitoring.  相似文献   

14.
We have developed a new carbon film electrode material with thornlike surface nanostructures to realize efficient direct electron transfer (DET) with enzymes, which is very important for various enzyme biosensors and for anodes or cathodes used in biofuel cells. The nanostructures were fabricated using UV/ozone treatment without a mask, and the obtained nanostructures were typically 2-3.5 nm high as confirmed by atomic force microscopy measurements. X-ray photoelectron spectroscopy and transmission electron microscopy revealed that these nanostructures could be formed by employing significantly different etching rates depending on nanometer-order differences in the local sp(3) content of the nanocarbon film, which we fabricated with the electron cyclotron resonance sputtering method. These structures could not be realized using other carbon films such as boron-doped diamond, glassy carbon, pyrolyzed polymers based on spin-coated polyimide or vacuum-deposited phthalocyanine films, or diamond-like carbon films because those carbon films have relatively homogeneous structures or micrometer-order crystalline structures. With physically adsorbed bilirubin oxidase on the nanostructured carbon surface, the DET catalytic current amplification was 30 times greater than that obtained with the original carbon film with a flat surface. This efficient DET of an enzyme could not be achieved by changing the hydrophilicity of the flat carbon surface, suggesting that DET was accelerated by the formation of nanostructures with a hydrophilic surface. Efficient DET was also observed using cytochrome c.  相似文献   

15.
In this work, we introduce the application of proton transfer reaction mass spectrometry (PTR-MS) for the selection of improved terpene synthase mutants. In comparison with gas chromatography mass spectrometry (GC-MS)-based methods, PTR-MS could offer advantages by reduction of sample preparation steps and analysis time. The method we propose here allows for minimal sample preparation and analysis time and provides a promising platform for the high throughput screening (HTS) of large enzyme mutant libraries. To investigate the feasibility of a PTR-MS-based screening method, we employed a small library of Callitropsis nootkatensis valencene synthase (CnVS) mutants. Bacterial cultures expressing enzyme mutants were subjected to different growth formats, and headspace terpenes concentrations measured by PTR-Qi-ToF-MS were compared with GC-MS, to rank the activity of the enzyme mutants. For all cultivation formats, including 96 deep well plates, PTR-Qi-ToF-MS resulted in the same ranking of the enzyme variants, compared with the canonical format using 100 mL flasks and GC-MS analysis. This study provides a first basis for the application of rapid PTR-Qi-ToF-MS detection, in combination with multi-well formats, in HTS screening methods for the selection of highly productive terpene synthases.  相似文献   

16.
New low-energy electron injection systems based on indirectly heated dispenser cathodes facilitate electron capture dissociation (ECD) in Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. In this joint report, details are presented of the design and performance of these systems on two commercial FTICR instruments, 9.4 T Bruker BioAPEX in Uppsala and 4.7 T IonSpec Ultima in Odense. New results include obtaining meaningful one-scan MS/MS data for isolated precursor ions with millisecond irradiation times. The ECD rate improvement is not only due to the larger total electron current, but the larger emitting area as well.  相似文献   

17.
Targeted tandem mass spectrometry (MS/MS) is an attractive proteomic approach that allows selective identification of peptides exhibiting abundance differences, e.g., between culture conditions and/or diseased states. Herein, we report on a targeted LC-MS/MS capability realized with a hybrid quadrupole-7 tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer that provides data-dependent ion selection, accumulation, and dissociation external to the ICR trap, and a control software that directs intelligent MS/MS target selection based on LC elution time and m/z ratio. We show that the continuous on-the-fly alignment of the LC elution time during the targeted LC-MS/MS experiment, combined with the high mass resolution of FTICR MS, is crucial for accurate selection of targets, whereas high mass measurement accuracy MS/MS data facilitate unambiguous peptide identifications. Identification of a subset of differentially abundant proteins from Shewanella oneidensis grown under suboxic versus aerobic conditions demonstrates the feasibility of such approach.  相似文献   

18.
Post-translational modifications (PTMs) of proteins are important in the activation, localization, and regulation of protein function in vivo. The usefulness of electron capture dissociation (ECD) and electron-transfer dissociation (ETD) in tandem mass spectrometry (MS/MS) using low-energy (LE) trap type mass spectrometer is associated with no loss of a labile PTM group regarding peptide and protein sequencing. The experimental results of high-energy (HE) collision induced dissociation (CID) using the Xe and Cs targets and LE-ETD were compared for doubly-phosphorylated peptides TGFLT(p)EY(p)VATR (1). Although HE-CID using the Xe target did not provide information on the amino acid sequence, HE-CID using the Cs target provided all the z-type ions without loss of the phosphate groups as a result of HE-ETD process, while LE-ETD using fluoranthene anion gave only z-type ions from z5 to z11. The difference in the results of HE-CID between the Xe and Cs targets demonstrated that HE-ETD process with the Cs target took place much more dominantly than collisional activation. The difference between HE-ETD using Cs targets and LE-ETD using the anion demonstrated that mass discrimination was much weaker in the high-energy process. HE-ETD was also applied to three other phosphopeptides YGGMHRQEX(p)VDC (2: X = S, 3: X = T, 4: X = Y). The HE-CID spectra of the doubly-protonated phosphopeptides (= [M + 2H]2+) of 2, 3, and 4 using the Cs target showed a very similar feature that the c-type ions from c7 to c11 and the z-type ions from z7 to z11 were formed via N-Cα bond cleavage without a loss of the phosphate group.  相似文献   

19.
Metabolic stable isotope labeling is increasingly employed for accurate protein (and metabolite) quantitation using mass spectrometry (MS). It provides sample-specific isotopologues that can be used to facilitate comparative analysis of two or more samples. Stable Isotope Labeling by Amino acids in Cell culture (SILAC) has been used for almost a decade in proteomic research and analytical software solutions have been established that provide an easy and integrated workflow for elucidating sample abundance ratios for most MS data formats. While SILAC is a discrete labeling method using specific amino acids, global metabolic stable isotope labeling using isotopes such as (15)N labels the entire element content of the sample, i.e. for (15)N the entire peptide backbone in addition to all nitrogen-containing side chains. Although global metabolic labeling can deliver advantages with regard to isotope incorporation and costs, the requirements for data analysis are more demanding because, for instance for polypeptides, the mass difference introduced by the label depends on the amino acid composition. Consequently, there has been less progress on the automation of the data processing and mining steps for this type of protein quantitation. Here, we present a new integrated software solution for the quantitative analysis of protein expression in differential samples and show the benefits of high-resolution MS data in quantitative proteomic analyses.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号