首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
In those cases where the information obtained by peptide mass fingerprinting or matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS/MS) is not sufficient for unambiguous protein identification, nano-electrospray ionization (nano-ESI) and/or electrospray ionization tandem mass spectrometry (ESI-MS/MS) analysis must be performed. The sensitivity of nano-ESI/MS, however, is lower than that of MALDI-MS, especially at very low analyte concentrations and/or in the presence of contaminants, such as salt and detergents. Moreover, to perform ESI-MS/MS, the peptide masses of the precursor ions must be known. The approach described in this paper, MALDI-directed nano-ESI-MS/MS, makes use of information obtained from the more sensitive MALDI-MS experiments in order to direct subsequent nano-ESI-MS/MS experiments. Peptide molecular ions found in the MALDI-MS analysis are then selected, as their (+2) precursor ions, for nano-ESI-MS/MS sequencing, even though these ions cannot be detected in the ESI-MS spectra. This method, originally proposed by Tempst et al. (Anal. Chem. 2000, 72: 777-790), has been extended to provide better sensitivity and shorter analysis times; also, a comparison with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been performed. These experiments, performed using quadrupole time-of-flight instruments equipped with commercially available nano-ESI sources, have allowed the unambiguous identification of in-gel digested proteins at levels below their ESI-MS detection limits, even in the presence of salts and detergents.  相似文献   

2.
Matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) and liquid secondary ion-tandem mass spectrometry (LSI-MS/MS) have been applied to the analysis of synthetic polymers to generate values for the average mass and the mass of the end groups. The average mass values were calculated for polymethylmethacrylate and polystyrene standards from the MALDI-MS data. Abundant fragment ions of the polymers, generated by means of LSI-MS/MS, were consistent with the known structures of the end groups of the polymers. Furthermore, losses from the side chains of the polymers were also observed in the LSI-MS/MS spectra.  相似文献   

3.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is one of the most widely used techniques in proteomics to achieve structural identification and characterization of proteins and peptides, including their variety of proteoforms due to post-translational modifications (PTMs) or protein–protein interactions (PPIs). MALDI-MS and MALDI tandem mass spectrometry (MS/MS) have been developed as analytical techniques to study small and large molecules, offering picomole to femtomole sensitivity and enabling the direct analysis of biological samples, such as biofluids, solid tissues, tissue/cell homogenates, and cell culture lysates, with a minimized procedure of sample preparation. In the last decades, structural identification of peptides and proteins achieved by MALDI-MS/MS helped researchers and clinicians to decipher molecular function, biological process, cellular component, and related pathways of the gene products as well as their involvement in pathogenesis of diseases. In this review, we highlight the applications of MALDI ionization source and tandem approaches for MS for analyzing biomedical relevant peptides and proteins. Furthermore, one of the most relevant applications of MALDI-MS/MS is to provide “molecular pictures”, which offer in situ information about molecular weight proteins without labeling of potential targets. Histology-directed MALDI-mass spectrometry imaging (MSI) uses MALDI-ToF/ToF or other MALDI tandem mass spectrometers for accurate sequence analysis of peptide biomarkers and biological active compounds directly in tissues, to assure complementary and essential spatial data compared with those obtained by LC-ESI-MS/MS technique.  相似文献   

4.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been used to directly analyze and image pharmaceutical compounds in intact tissue. The anti-tumor drug SCH 226374 was unambiguously determined in mouse tumor tissue using MALDI-QqTOFMS (QSTAR) by monitoring the dissociation of the protonated drug at m/z 695.4 to its predominant fragment at m/z 228.1. A second drug, compound A, was detected in slices of rat brain tissue following oral administration with doses ranging from 1-25 mg/kg. Quantitation of compound A from whole brain homogenates using routine high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) procedures revealed that concentrations of the drug in whole brain varied from a low of 24 ng/g to a high of 1790 ng/g. The drug candidate was successfully detected by MALDI-QqTOF in samples from each dose, covering a range of approximately two orders of magnitude. In addition, good correlation was observed between the MALDI-QqTOFMS intensities at each dose with the HPLC/MS/MS results. Thus the MALDI-MS response is proportional to the amount of drug in tissue. Custom software was developed to facilitate the imaging of small molecules in tissue using the MALDI-QqTOF mass spectrometer. Images revealing the spatial localization of SCH 226374 in tumor tissue and compound A in brain tissue were acquired.  相似文献   

5.
So far, there have been only a few matrices reported for detection of polysaccharides with molecular weight higher than 3000 Daltons by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). In this work, we found that 2',4',6'-trihydroxyacetophenone (THAP) is a good matrix for MALDI time-of-flight MS analysis of polysaccharides with broad mass range. Large polysaccharides, dextrans, glycoproteins and polysialic acids have been successfully detected by MALDI-MS with THAP as matrix.  相似文献   

6.
The structural characterization of Glycosyl-Inositol-Phospho-Ceramides (GIPCs), which are the main sphingolipids of plant tissues, is a critical step towards the understanding of their physiological function. After optimization of their extraction, numerous plant GIPCs have been characterized by mass spectrometry. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) full scan analysis of negative ions provides a quick overview of GIPC distribution. Clear differences were observed for the two plant models studied: six GIPC series bearing from two to seven saccharide units were detected in tobacco BY-2 cell extracts, whereas GIPCs extracted from A. thaliana cell cultures and leaves were less diverse, with a dominance of species containing only two saccharide units. The number of GIPC species was around 50 in A. thaliana and 120 in tobacco BY-2 cells. MALDI-MS/MS spectra gave access to detailed structural information relative to the ceramide moiety, the polar head, as well as the number and types of saccharide units. Once released from GIPCs, fatty acid chains and long-chain bases were analyzed by GC/MS to verify that all GIPC series were taken into account by the MALDI-MS/MS approach. ESI-MS/MS provided complementary information for the identification of isobaric species and fatty acid chains. Such a methodology, mostly relying on MALDI-MS/MS, should open new avenues to determine structure-function relationships between glycosphingolipids and membrane organization.  相似文献   

7.
MALD I-MS分析具有高灵敏度、高分辨率、高质量准确度、制样快速、操作简单及高通量等优点,具有使各种不同类型物质离子化的能力。目前已广泛应用于化学、化工、材料、环境、地质、能源、刑侦、药物、生命科学等领域中。MALD I-MS最早主要用于分析各种生物大分子及聚合物。近年  相似文献   

8.
An “off-line” combination of capillary electrophoresis (CE) with matrix-assisted laser-desorption mass spectrometry (MALDI-MS) has been developed for the structural characterization of CE-separated peptides and proteins. Using a sheath flow interface, similar to that developed for “on-line” CE—fast atom bombardment MS and CE—electrospray MS, an efficient sample isolation procedure has been developed which is applicable to bioorganic compounds in aqueous buffer solutions. This isolation procedure, with subsequent transfer to the MALDI-MS sample target, has been successfully used for the direct analysis of CE-separated proteins of M r up to 67 000, and a mixture of apolipoprotein AII monomer and homodimer, using sample amounts of less than 1 pmol.  相似文献   

9.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

10.
Matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) was applied to identify markers for cellular differentiation. The differentiation of a human colon epithelial carcinoma T84 cell line was monitored over a period of 28 days by transepithelial electrical resistance (TER) measurements, alkaline phosphatase (AP) assay, and MALDI-TOF mass spectral fingerprints combined with statistical analysis. MALDI-MS generated specific mass spectral fingerprints characteristic of cell differentiation. Twenty-two ions were selected as diagnostic signals of fully differentiated T84 cells. Ten protein ion signals, detected by MALDI-MS and validated by statistical analysis, were proposed as T84 cell differentiation markers. Among these signals, ubiquitin was identified as a T84 cell differentiation marker by nanospray liquid chromatography/tandem mass spectrometry (nanoLC/MS/MS). Moreover, depending on the concentration of the cells seeded on the growth support, it was possible to predict the timing of the exponential phase and of cellular differentiation by MALDI-MS-derived marker ions. MALDI-TOFMS was compared to other methods for the determination of cellular differentiation: TER measurements are rapid but yield limited information as to the cellular differentiation state. AP assays are more specific for the differentiation state but take more time. By contrast, MALDI-MS has been found to be a fast, sensitive and precise method for cell differentiation assessment and provides the opportunity for multiplexing and high throughput. Moreover, the consumable costs per assay are very low.  相似文献   

11.
Lipidomics is a rapidly expanding area of scientific research and there are a number of analytical techniques that are employed to facilitate investigations. One such technique is matrix-assisted laser desorption ionisation (MALDI) mass spectrometry (MS). Previous MALDI-MS studies involving lipidomic investigation have included the analysis of a number of different ex vivo tissues, most of which were obtained from animal models, with only a few being of human origin. In this study, we describe the use of MALDI-MS, MS/MS and MS imaging methods for analysing lipids within cross-sections of ex vivo human skin. It has been possible to tentatively identify lipid species via accurate mass measurement MALDI-MS and also to confirm the identity of a number of these species via MALDI-MS/MS, in experiments carried out directly on tissue. The main lipid species detected include glycerophospholipids and sphingolipids. MALDI images have been generated at a spatial resolution of 150 and 30 μm, using a MALDI quadrupole time-of-flight Q-Star Pulsar-i TM (Applied Biosystems/MDS Sciex, Concord, ON, Canada) and a MALDI high-definition MS (HDMS) SYNAPT G2-HDMSTM system (Waters, Manchester, UK), respectively. These images show the normal distribution of lipids within human skin, which will provide the basis for assessing alterations in lipid profiles linked to specific skin conditions e.g. sensitisation, in future investigations.  相似文献   

12.
陈瑶函  晏国全  周新文  杨芃原 《色谱》2010,28(2):135-139
糖链结构的质谱解析是今后糖蛋白分析中的重要研究内容,其中完整糖肽的分析,由于可以同时获得糖基化位点和对应糖链的结构信息,更具有重要意义和研究前景。本工作对质谱软电离技术在完整糖肽分析中的应用进行了研究,其中包括了基质辅助激光解吸电离(matrix-assisted laser desorption ionization, MALDI)和电喷雾电离(electrospray ionization, ESI)技术。通过平行使用两种串联质谱(tandem mass spectrometry, MS/MS)分析策略: MALDI-MS/MS和ESI-MS/MS对目标糖蛋白——辣根过氧化物酶进行分析,并讨论了其互补性。结果表明,MALDI和ESI技术各有优劣,结合串联质谱分析,可获得糖肽的糖链结构信息;两条路线互补使用,在揭示蛋白质糖基化修饰(位点和结构)的研究中十分必要。  相似文献   

13.
A rapid method for analysis of glycans of glycoproteins is presented. This method comprised deglycosylation, sample cleanup and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis of glycans. The enzymatic deglycosylation of N-linked glycoproteins was enhanced in terms of speed and reproducibility using an enzyme-friendly surfactant. The released glycans were desalted using a micro-scale solid phase extraction (SPE) device packed with a hydrophilic interaction chromatography (HILIC) sorbent. Hydrophilic glycans were well retained by SPE, while salts and surfactants were removed from the sample. The glycans were eluted using 25-50 microL of solvent and analyzed directly without derivatization using MALDI-MS. MALDI quadrupole time-of-flight (Q-Tof) instrumentation was utilized for glycan profiling and structure characterization by tandem mass spectrometry (MS/MS). The presented method allows sensitive analysis of glycans benefiting from optimized deglycosylation reactions and efficient sample cleanup.  相似文献   

14.
The application of guanidination chemistry, the conversion of lysine into homoarginine residues, is used to illustrate several important general considerations relating to the use of differential isotope labelling for relative quantification in proteomics. The derivatisation procedure has been optimised for automation using a liquid handling station designed for proteomics. Automated application of the procedure to the analysis of in-gel tryptic digests of multiple spots from the two-dimensional gel electrophoretic (2DE) analysis of proteins from the FDCP-mix cell line shows near-universal improvement in protein identification as a result of derivatisation. This chemistry has been extended for relative quantification, applicable to matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) and also tandem mass spectrometry (MS/MS). It provides a robust method for the quantitative comparison of two samples that have been separated by 2DE. A peptide pair may display poor detection during MS analysis, causing their reliable relative quantification to be difficult. In such circumstances, the additional selectivity of detection provided by MS/MS can substantiate identification and allow relative quantification of these species via product ion signal ratios.  相似文献   

15.
The measurement of deuterium incorporation kinetics using hydrogen/deuterium (H/D) exchange experiments is a valuable tool for the investigation of the conformational dynamics of biomolecules in solution. Experiments consist of two parts when using H/D exchange mass spectrometry to analyse the deuterium incorporation. After deuterium incorporation at high D(2)O concentration, it is necessary to decrease the D(2)O concentration before the mass analysis to avoid deuterium incorporation under artificial conditions of mass spectrometric preparation and measurement. A low D(2)O concentration, however, leads to back-exchange of incorporated deuterons during mass analysis. This back-exchange is one of the major problems in H/D exchange mass spectrometry and must be reduced as much as possible. In the past, techniques using electrospray ionization (ESI) had the lowest back-exchange values possible in H/D exchange mass spectrometry. Methods for the measurement of H/D exchange by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) that have been developed since 1998 have some significant advantages, but they could not achieve the back-exchange minima of ESI methods. Here, we present a protocol for H/D exchange MALDI-MS which allows for greater minimization of back-exchange compared with H/D exchange ESI-MS under similar conditions.  相似文献   

16.
This review summarizes various approaches for the analysis of low molecular weight (LMW) compounds by different laser desorption/ionization mass spectrometry techniques (LDI-MS). It is common to use an agent to assist the ionization, and small molecules are normally difficult to analyze by, e.g., matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) using the common matrices available today, because the latter are generally small organic compounds themselves. This often results in severe suppression of analyte peaks, or interference of the matrix and analyte signals in the low mass region. However, intrinsic properties of several LDI techniques such as high sensitivity, low sample consumption, high tolerance towards salts and solid particles, and rapid analysis have stimulated scientists to develop methods to circumvent matrix-related issues in the analysis of LMW molecules. Recent developments within this field as well as historical considerations and future prospects are presented in this review.  相似文献   

17.
The characterization of glycosylation in proteins by mass spectrometry (MS) is often impeded by strong suppression of ionization of glycopeptides in the presence of non-glycosylated peptides. Glycopeptides with a large carbohydrate part and a short peptide backbone are particularly affected by this problem. To meet the goal of generating mass spectra exhibiting glycopeptide coverages as complete as possible, derivatization of glycopeptides offers a practical way to increase their ionization yield. This paper investigated derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) which is a rapid labeling technique commonly used for fluorescence detection in high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE). As test samples we used peptides and glycopeptides obtained by enzymatic digestion of three different glycoproteins, i.e., human antithrombin, chicken ovalbumin, and bovine alpha1-acid-glycoprotein. It was found that AQC derivatization resulted in strongly increased signal intensities when analyzing small peptides and glycopeptides by matrix-assisted laser desorption/ionization (MALDI)-MS. For these compounds the limit of detection could be reduced to low fmol amounts. Without derivatization only glycopeptides containing large peptide backbones were detected by MALDI-MS. This effect was even significant when glycopeptides were pre-separated and enriched by means of lectin affinity chromatography before MALDI-MS analysis and when using electrospray ionization (ESI). This labeling method, applied in combination with MS detection for the first time, was found to be well suited for the enhancement of detection sensitivity for small glycopeptides in MALDI-MS analysis and thus for reducing the need for pre-separation steps.  相似文献   

18.
Plasma protein profiling with mass spectrometry is currently being evaluated as a diagnostic tool for cancer and other diseases. These experiments consist of three steps: plasma protein fractionation, analysis with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS), and comparisons of the MALDI profiles to develop diagnostic fingerprints using bioinformatic techniques. While preliminary results appear promising in small sample groups, the method is limited by the sensitivity of MALDI-MS for intact proteins, the limited mass range of MALDI-MS, and difficulties associated with isolating individual proteins for identification to validate the diagnostic fingerprint. Here we present an alternative and improved method directed toward diagnostic protein discovery, which incorporates proteolytic peptide profiling, bioinformatic targeting of ion signals, and MALDI tandem mass spectrometry (MS/MS) peptide sequencing, rather than fingerprinting. Pancreatic cancer patients, pancreatitis patients, and controls are used as the model system. Profiling peptides after enzymatic digestion improves sensitivity and extends the accessible protein molecular weight range when compared to intact protein profiling. The first step is to extract and fractionate the proteins from plasma. Each fraction is digested with trypsin and subsequently analyzed by MALDI-MS. Rather than using bioinformatic analysis as a pattern-matching technique, peptides are targeted based on the disease to control peak intensity ratios measured in the averages of all mass spectra in each group and t-tests of the intensity of each individual peak. The targeted peptide ion signals are subsequently identified using MALDI-MS/MS in quadrupole-TOF and tandem-TOF instruments. This study found not only the proteins targeted and identified by a previous protein profiling experiment, but also detected additional proteins. These initial results are consistent with the known biology of pancreatic cancer or pancreatitis, but are not specific to those diseases.  相似文献   

19.
Direct tandem mass spectrometric (MS/MS) analysis of small, singly charged protein ions by tandem time-of-flight mass spectrometry (TOFMS) is demonstrated for proteins up to a molecular mass of 12 kDa. The MALDI-generated singly charged precursor ions predominantly yield product ions resulting from metastable fragmentation at aspartyl and prolyl residues. Additional series of C-terminal sequence ions provide in some cases sufficient information for protein identification. The amount of sample required to obtain good quality spectra is in the high femtomolar to low picomolar range. Within this range, MALDI-MS/MS using TOF/TOF trade mark ion optics now provides the opportunity for direct protein identification and partial characterization without prior enzymatic hydrolysis.  相似文献   

20.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has rarely been used in the field of therapeutic drug monitoring, partly because of the complexity of the ionization processes between the compounds to be quantified and the many MALDI matrices available. The development of a viable MALDI-MS method that meets regulatory guidelines for bioanalytical method validation requires prior knowledge of the suitability of (i) the MALDI matrix with the analyte class and properties for ionization, (ii) the crystallization properties of the MALDI matrix with automation features, and (iii) the MS instrumentation used to achieve sensitive and specific measurements in order to determine low pharmacological drug concentrations in biological matrices. In the present hybrid article/white paper, we review the developments required for the establishment of MALDI-MS assays for the quantification of drugs in tissues and plasma, illustrated with concrete results for the different steps. We summarize the necessary parameters that need to be controlled for the successful development of fully validated MALDI-MS methods according to regulatory authorities, as well as currently unsolved problems and promising ways to address them. Finally, we propose an expert opinion on future perspectives and needs in order to establish MALDI-MS as a universal method for therapeutic drug monitoring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号