首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
O435.2 2005053232 人眼不同瞳孔直径波前像差特性分析=Property analysis of wavefront aberration of different human eye’s pupils [刊,中]/徐高平(中科院光电所.四川,成都(610209)),徐 翔…∥光电工程.-2005,32(7).-38-41 采用Hartmann-Shack人眼像差仪.测量了人眼在3.1 mm,5.2 mm和6 mm瞳孔直径下的波前像差。波前像差 的RMS值表明,随着瞳孔直径的增大,人眼各阶波前像差 均随着增大。与瞳孔直径为3.1 mm时相比,瞳孔直径为 6 mm和5.2 mm时,Zernike 2~10阶波前像差的RMS值 分别增大1.2~7.7倍和1.1~4.8倍。用调制传递函数 (MTF)和Strehl比评价了高阶波前像差对成像质量的影 响。结果表明,大瞳孔高阶波前像差对成像质量的影响大 于小瞳孔;在3.1 mm,5.2 mm和6 mm瞳孔直径下,欲达 到衍射极限的Strehl比率,分别需要矫正Zernike波前像 差前2~4阶、前3~6阶和前5~7阶,需矫正的像差阶数 随瞳孔直径的增大而增加。图4参7(于晓光)  相似文献   

2.
O435.2 2006031869双贴合无光焦度校正板在主反射镜前的两镜系统的像差特性=Aberration characteristics of a two-mirror systemwith a two-lens zero-power corrector placed before the pri-mary mirror[刊,中]/何宗平(合肥运涛光电科技有限公司.安徽,合肥(230031)) ,胡明勇…∥量子电子学报.—2006 ,23(1) .—31-36讨论了双贴合无光焦度校正板放在主镜前的双反射球面系统,根据像差理论分析了消像差的条件,研究了系统中各种参数的变化对系统高级残余像差的影响。结果表明主镜的相对孔径越大,系统的残余像差增加;正透镜在前的校正板结构…  相似文献   

3.
O435.22006010024晶体元件的像差计算=Calculation of aberations intro-duced by a crystal components[刊,中]/张为权(浙江理工大学物理系.浙江,杭州(310033))∥光子学报.—2005,34(7).—1090-1093建立了折射光线轨迹的软件包,提出了波像差的计算方法。利用这个软件包,分析了双焦透镜的各类像差和像差与入射角的关系。这个软件包的特点是各种物理量的计算十分清晰,它为改进晶体元件的设计提供了理论依据。图8参8(王淑平)几何光学 像差、像质评价@王淑平…  相似文献   

4.
微光像增强器信噪比理论极限问题研究   总被引:1,自引:0,他引:1  
向世明 《应用光学》2008,29(5):724-726
信噪比是微光像增强器的重要参数之一,其值的高低决定着微光成像系统在低照度条件下的探测距离和图像清晰度。根据线性系统信噪比链理论, 借助系统噪声因子关系式,分析了微光像增强器的理论极限信噪比(S/N)limit。在系统各级不附加任何噪声(即NF=1),或仅受输入光子及光电子数涨落噪声限制的理想条件下,给出像管不同量子效率(η)之最大信噪比(S/N)limit的表达式;在η=1的极限情况下,求得该像管的理论极限信噪比(S/N)limit≤64。  相似文献   

5.
重点沦述光学稳像的光学原理,并引用具体的平面反射镜作为光学补偿元件(也就是光稳元件)的稳像方式加以阐述,由此导出倒像系统和正像系统达到相对稳像和绝对隐像时补偿角与扰动角之间的关系式。论述采用会聚光路稳像时由棱镜的微量转动而达到绝对稳像时棱镜转动中心的求法。论述光稳元件兼作转像棱镜时光稳元件的有效孔径与转功中心和棱镜位置的关系。  相似文献   

6.
人眼高阶像差校正和视觉分析系统   总被引:10,自引:0,他引:10  
人眼除具有可用眼镜或接触镜校正的低阶像差(离焦、像散)之外,还普遍存在高阶像差。高阶像差的存在影响着屈光系统的成像质量。为研究高阶像差对视觉功能的影响,利用自适应光学技术,建立了具有校正高阶像差和产生高阶像差双重功能的人眼高阶像差校正和视觉分析系统。介绍了系统实现高阶像差校正和视觉分析的工作原理;阐述了波前校正器、哈特曼波前探测系统、控制系统等关键单元技术;列出了系统对泽尼克模式像差的校正效果,绝大多数像差从0.5λ降低到0.2λ以下;阐明系统功能的实现过程,并给出仿真实验的结果。该系统为进一步研究高阶像差对视功能的影响提供了有效的手段。  相似文献   

7.
TH703 2005010039 偏心和倾斜光学系统初级像差理论的研究=Study on the primary aberration theory of decentered and tilted optical system[刊,中]/樊学武(中科院西安光机所空间光学室. 陕西,西安(710068)),陈荣利…∥光子学报.-2004,33 (4).-494-496 在共轴光学系统波像差的基础上,推导出了光学元件的偏心和倾斜分别对主要像差的影响。得出了除了球差  相似文献   

8.
应用波分复用改善像束传像系统像质的研究   总被引:1,自引:0,他引:1  
本文通过分析空间波分复用系统中包散元件的色散平均效应,用线扩散传递函数研究了像束传像性质,由光学成像的本征理论用像束成像信息量分析了波分复用改善像束传像像质的机制,并从实验上验证了上述分析结论.  相似文献   

9.
在早期的研究中,采用出、入瞳直径相等的双通系统进行人眼像差测量时,两个通道的奇像差相互抵消,造成奇像差(如彗差)无法测量。本文建立全新的模拟眼模型进行实验,验证双通系统在波前测量时,是否存在人眼奇像差抵消的现象。采用典型双通系统——哈特曼波前探测系统进行实验,并将出瞳光阑直径固定为6mm,改变系统入瞳光阑大小(1~8mm)。实验结果表明,双通系统中,人眼奇像差在出、入瞳直径相等时可测,且人眼奇像差测量与出、入瞳直径差异无关,因此人眼奇像差测量在双通系统中不存在抵消的现象。  相似文献   

10.
为了避免连续变焦光学系统中,各组元像差自动设计对设计者经验要求高、计算复杂且计算量大的难点,提出了一种利用差值线性方程组进行像差自动设计的方法,并用此方法设计了一套可见光波段连续变焦光学系统。利用高斯光学计算理想近轴系统的结构参数;利用差值线性方程组进行系统像差自动设计,使系统的初级像差系数SI、SII与SIII在各焦距位置处近似相等;基于像差自动设计结果计算光学系统的初始结构参数;利用Zemax自动设计软件进行像差校正平衡。优化结果表明:系统可实现20~300 mm的连续变焦,且在截止频率50 lp/mm处,各焦距位置各视场的传递函数(MTF)均大于0.4。因此,应用差值线性方程组法进行像差自动设计,可以简化计算,减少对设计者经验的依赖,并且能够取得良好的像质。  相似文献   

11.
立体图像质量的主观评价方案   总被引:3,自引:1,他引:2  
立体图像质量评价在立体图像压缩、处理以及通信领域中有着十分重要的作用,一种好的立体图像质量客观评价方法也要依赖于立体图像的主观评价.本文基于人眼的立体视觉特性,提出了相对完整的立体图像质量主观评价方案,该方案主要分为立体图像库的建立、评测者的选择、观看条件的描述、评测者的训练和测试、数据处理和实验结果分析六个方面.实验中,评测者根据自己的主观感受,对所选取的立体图像进行评分,最后用数理统计理论对所得数据进行处理.结果表明,本文所提出的主观评价方案可行,能够正确反映立体图像质量的优劣.  相似文献   

12.
立体图像质量评价在立体图像压缩、处理以及通信领域中有着十分重要的作用,一种好的立体图像质量客观评价方法也要依赖于立体图像的主观评价.本文基于人眼的立体视觉特性,提出了相对完整的立体图像质量主观评价方案,该方案主要分为立体图像库的建立、评测者的选择、观看条件的描述、评测者的训练和测试、数据处理和实验结果分析六个方面.实验中,评测者根据自己的主观感受,对所选取的立体图像进行评分,最后用数理统计理论对所得数据进行处理.结果表明,本文所提出的主观评价方案可行,能够正确反映立体图像质量的优劣.  相似文献   

13.
基于特征结构相似度的遥感影像融合质量评价指标   总被引:2,自引:2,他引:0  
刘军  邵振峰 《光子学报》2011,40(1):126-131
在分析现有影像融合评价指标的基础上,根据人眼视觉特性,提出一种基于特征结构相似度的遥感影像融合评价指标.首先从原始影像和融合影像中提取空间特征和光谱特征,然后综合计算空间特征和光谱特征的结构相似度作为评价指标,达到评价影像质量的目的.通过对多种传感器获取的遥感影像进行融合实验,结果表明该客观评价方法与主观评价结果一致,...  相似文献   

14.
基于结构相似度的图像融合质量评价   总被引:35,自引:10,他引:25  
狄红卫  刘显峰 《光子学报》2006,35(5):766-771
在分析现有图像融合质量评价方法特点的基础上,提出了新型的、基于结构相似度的图像融合质量评价方法.针对不同情况,分别采用平均结构相似度、加权平均结构相似度、结构信息与交互信息量之乘积作为图像融合质量客观评价标准.该方法充分考虑了图像的结构信息和人类视觉系统的特性,可以为不同场合下选择不同的算法提供依据.对不同融合算法的质量评价结果表明,该方法是一种有效的图像融合质量评价方法.  相似文献   

15.
In this paper, to improve the slow processing speed of the rule-based visible and NIR (near-infrared) image synthesis method, we present a fast image fusion method using DenseFuse, one of the CNN (convolutional neural network)-based image synthesis methods. The proposed method applies a raster scan algorithm to secure visible and NIR datasets for effective learning and presents a dataset classification method using luminance and variance. Additionally, in this paper, a method for synthesizing a feature map in a fusion layer is presented and compared with the method for synthesizing a feature map in other fusion layers. The proposed method learns the superior image quality of the rule-based image synthesis method and shows a clear synthesized image with better visibility than other existing learning-based image synthesis methods. Compared with the rule-based image synthesis method used as the target image, the proposed method has an advantage in processing speed by reducing the processing time to three times or more.  相似文献   

16.
具有数字图像处理功能的运动分析系统   总被引:2,自引:0,他引:2  
本文描述了一种基于高速摄影的运动分析系统,它是由光学投影系统、CCD摄像头、图像卡和微机构成的新型摄影图像分析系统,利用微机终端显示器作为坐标测量器,对胶片的测量分辨率达0.01mm。系统能对图像进行坐标采集和运动分析外,还具有丰富的数字图像处理功能,可对原输入图像实行反转、对比增强、平滑滤波、边缘检测等处理。系统软件还对输片机构实行计算机控制。文中给出了数字图像处理结果实例。  相似文献   

17.
This paper presents a robust contrast enhancement algorithm based on histogram equalization methods named Median-Mean Based Sub-Image-Clipped Histogram Equalization (MMSICHE). The proposed algorithm undergoes three steps: (i) The Median and Mean brightness values of the image are calculated. (ii) The histogram is clipped using a plateau limit set as the median of the occupied intensity. (iii) The clipped histogram is first bisected based on median intensity then further divided into four sub images based on individual mean intensity, subsequently performing histogram equalization for each sub image. This method achieves multi objective of preserving brightness as well as image information content (entropy) along with control over enhancement rate, which in turn suits for consumer electronics applications. This method avoids excessive enhancement and produces images with natural enhancement. The simulation results show that MMSICHE method outperforms other HE methods in terms of various image quality measures, i.e. average luminance, average information content (entropy), absolute mean brightness error (AMBE) and background gray level.  相似文献   

18.
Objective image quality mcasure, which is a fundamental and challenging job in image processing, evaluates the image quality consistently with human perception automatically. On the assumption that any image distortion could be modeled as the difference between the directional projection-based maps of reference and distortion images, wc propose a new objective quality assessment method based on directional projection for full reference model. Experimental results show that the proposed metrics are well consistent with the subjective quality score.  相似文献   

19.
The image displaying methods used in a millimeter wave radiometric imaging system have great influence on its imaging quality. In order to obtain high quality millimeter wave radiometric images, intensive studies on the image displaying methods are needed. This paper describes the image displaying method of Ground-based 8mm Millimeter Wave Radiometric Imaging (GMWRI) system and compares two different image displaying methods. The experimental results prove the unequal size element arc displaying method fits GMWRI system better.  相似文献   

20.
为保证手术安全及操作精度,基于磁共振图像导航的手术机器人系统需具备磁共振设备兼容性. 针对这一问题,本文提出了基于磁共振图像质量评价的手术机器人系统磁共振设备兼容性分析方法,扩展了图像数据集,并结合图像信噪比、图像变化因数、磁共振图像畸变量等评价参数,逐一分析机器人系统组件通电、机器人系统运动对磁共振图像质量产生的影响,建立图像质量评价依据. 实验结果表明,该质量评价方法可充分分析手术机器人及其系统组件的磁共振兼容性,且可为医疗手术机器人系统组件的磁共振兼容性分析提供测试方法与理论依据.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号