首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new method was developed for the determination of six fluoroquinolone antibiotics including fleroxacin, levofloxacin, ciprofloxacin, lomfloxacin, enrofloxacin, and sparfloxacin in chicken breast muscle, in which the extraction and clean-up were performed in one step by microwave irradiation. The mixture of ACN containing 0.3% v/v phosphoric acid/water pH 3 (70:30, v/v) was used as the extraction solution and hexane was used as the clean-up solution. The extract was analyzed by liquid chromatography-tandem mass spectrometry system. The RSDs of intra- and inter-day obtained are in the range of 1.0-10.4 and 3.8-13.6%, respectively. In the three fortified levels of chicken breast muscle (20, 100, and 500 ng/g), the recoveries of fluoroquinolone antibiotics ranging from 66.0 to 97.2% are obtained. The LODs are in the range of 2.7-6.7 ng/g. This method simplifies the process of the sample preparation and reduces the operation errors.  相似文献   

2.
A simple, selective and sensitive gradient reversed-phase liquid chromatography method has been developed for the separation and determination of 2,3-dichlorobenzoic acid, which is an intermediate of the lamotrizine drug substance, and its regio isomers. The separation was achieved on a reversed-phase United States Pharmacopeia L1 (C-18) column using 0.01 M ammonium acetate buffer at pH 2.5 and methanol (50:50 v/v) mixture as mobile phase A and a methanol and water mixture (80:20 v/v) as mobile phase B in a gradient elution at flow rate 1.2 mL/min with ultraviolet detection at 210 nm. The method is found to be selective, precise, linear, accurate and robust. It was used for quality assurance and monitoring the synthetic reactions involved in the process development of lamotrizine. The method is found to be simple, rapid, specific and reliable for the determination of unreacted levels of raw materials and isomers in reaction mixtures and finished product lamotrizine. The method was fully validated as per International Conference of Harmonization guidelines and results from validation confirm that the method is highly suitable for its intended purpose.  相似文献   

3.
建立了一种高效、低成本的固相萃取-高效液相色谱(SPE-HPLC)同时测定鸡粪中6种常见抗生素(2种四环素类、2种喹诺酮类和2种磺胺类)的分析方法。样品经EDTA-McIlvaine缓冲液和有机混合提取液(甲醇-乙腈-丙酮,2:2:1,v/v/v)提取,过HLB固相萃取柱净化,甲醇-二氯甲烷(7:3,v/v)洗脱,高效液相色谱-二极管阵列检测器测定,检测波长λ=270 nm,柱温32℃,流动相为乙腈-0.7%(v/v)磷酸水溶液。该方法在0.5~100 mg/L质量浓度范围内的标准曲线相关系数r2在0.9999~1之间,样品加标回收率在70.0%~116.3%之间,相对标准偏差为1.2%~16.6%。方法检出限为1.3~6.7 μg/kg,定量限为3.5~9.2 μg/kg。应用该方法对辽宁省抚顺市某养鸡场当天的鸡粪进行检测,诺氟沙星和恩诺沙星(喹诺酮类)含量为未检出~9.23 mg/kg和1.57~7.69 mg/kg,磺胺二甲嘧啶(磺胺类)含量为2.02~13.05 mg/kg,磺胺甲恶唑、土霉素和四环素未测出。  相似文献   

4.
A high-performance liquid chromatography method for the microscale determination of alpha- and gamma-tocopherol in leaves, flowers and fresh beans from Moringa oleifera is reported. The method includes microscale saponification and extraction with n-hexane. Optimized conditions for reversed-phase HPLC with UV detection were as follows: column, 25 cm x 0.46 cm, Exil ODS 5-microm; column temperature, 25 degrees C; mobile phase, a 20:80 (v/v) mixture of methanol:acetonitrile; flow rate, 1.0 ml/min. With these conditions, method precision (relative standard deviation) was 5.6% for alpha-tocopherol and 4.9% for gamma-tocopherol. We used this method to measure alpha- and gamma-tocopherol in samples from M. oleifera as part of nutritional studies in edible plants cultivated in the Northwest México.  相似文献   

5.
Three naphthoquinones, plumbagin (1), 3,3'-biplumbagin (2) and elliptinone (3), isolated from Plumbago indica roots by antibacterial bioassay-guided isolation, were used as standard markers for quantitative determination. A reversed-phase HPLC method was established for the simultaneous determination of the naphthoquinones in P. indica root extracts. The method utilised a Phenomenex? ODS column (4.6?×?150?mm, 5?μm) at 25°C with a mixture of methanol and 5% aqueous acetic acid (80?:?20 v/v) as the mobile phase at a flow rate of 0.85?mL/min, and UV detection at 260?nm. The parameters of linearity, precision, accuracy specificity and sensitivity of the method were evaluated. The recovery of the method was 98.6-100.6% with good linearity (r (2?)≥?0.9997) for all three naphthoquinones. A high degree of sensitivity, specificity as well as repeatability and reproducibility (R.S.D. values less than 5%) were also achieved.  相似文献   

6.
A selective and highly sensitive liquid chromatographic method for the determination of ganciclovir (anti-virus drug) in human serum was described. After ganciclovir and acyclovir (internal standard; IS) were extracted with solid-phase extraction cartridge from serum, they were converted into fluorescent derivatives by reaction with phenylglyoxal in a phosphate buffer (pH 5.8) at 20 degrees C for 30 min. The derivatives were separated by reversed-phase column with a mixture of acetonitrile-1 mM phosphate buffer (pH 6.2) (18:82, v/v), and were then detected spectrofluorometrically at 512 nm with excitation at 365 nm. Extraction recoveries were 87.0-91.6% for ganciclovir and 86.8-92.3% for IS. The detection limit for ganciclovir spiked to serum was 5 ng ml-1 serum (306 fmol on column) at a signal-to-noise ratio of three. The accuracy and precision of this method were 7.6% and 5.0% even at low concentration (20 ng ml-1). The within- and between-day variations are lower than 7.6% and 8.1%, respectively.  相似文献   

7.
A method for direct determination of cadmium, chromium, copper and lead in sediments and soil samples by electrothermal atomic absorption spectrometry using Zr, Ir, etylenediamine acetic acid (EDTA), Zr + EDTA, Ir + EDTA, Zr + Ir and Zr + Ir + EDTA as chemical modifiers in 0.5% (v/v) Triton X-100 plus 0.2% (v/v) nitric acid mixture used as diluent was developed. The effects of mass and mass ratio of modifiers on analytes in sample solutions were studied. The optimum masses and mass ratios of modifiers: 20 microg of Zr, 4 microg of Ir, 100 microg of EDTA and 20 microg of Zr + 4 microg of Ir + 100 microg of EDTA, were used to enhance the analyte signals. Pyrolysis and atomization temperatures, atomization and background absorption profiles, characteristic masses, and detection limits of analytes in samples were compared in the presence or absence of a modifier. The detection limits and characteristic masses of analytes in a 0.5% (m/v) dissolved sample (dilution factor of 200 ml g(-1)) obtained with Zr + Ir + EDTA are 8.0 ng g(-1) and 1.2 pg for Cd, 61 ng g(-1) and 4.3 pg for Cr, 32 ng g(-1) and 23 pg for Cu, and 3.4 ng g(-1) and 19 pg for Pb, respectively. The Zr + Ir + EDTA modifier mixture was found to be preferable for the determination of analytes in sediment and soil-certified and standard reference materials. Depending on the sample type, the percent recoveries of analytes were increased from 81 to 103% by using the proposed modifier mixture; the results obtained are in good agreement with the certified values.  相似文献   

8.
A rapid, accurate and sensitive method has been developed for the quantitative determination of four fluoroquinolone antimicrobial agents, enoxacin, norfloxacin, ofloxacin and ciprofloxacin, with high in-vitro activity against a wide range of Gram-negative and Gram-positive organisms.A Kromasil 100 C(8) 250 mm x 4 mm, 5 microm analytical column was used with an eluting system consisting of a mixture of CH(3)CN-CH(3)OH-citric acid 0.4 mol L(-1) (7:15:78 %, v/v). Detection was performed with a variable wavelength UV-visible detector at 275 nm resulting in limits of detection: 0.02 ng per 20 microL injection for enoxacin and 0.01 ng for ofloxacin, norfloxacin and ciprofloxacin. Hydrochlorothiazide (HCT) was used as internal standard at a concentration of 2 ng microL(-1). A rectilinear relationship was observed up to 2 ng microL(-1) for enoxacin, 12 ng microL(-1) for ofloxacin, 3 ng microL(-1) for norfloxacin, and 5 ng microL(-1) for ciprofloxacin. Separation was achieved within 10 min. The statistical evaluation of the method was examined by performing intra-day (n=8) and inter-day precision assays (n=8) and was found to be satisfactory with high accuracy and precision. The method was applied to the direct determination of the four fluoroquinolones in human blood serum. Sample pretreatment involved only protein precipitation with acetonitrile. Recovery of analytes in spiked samples was 97+/-6% over the range 0.1-0.5 ng microL(-1).  相似文献   

9.
使用Chiralpak IC(纤维素-三(3,5-二氯苯基氨基甲酸酯)共价键合硅胶)手性柱,建立了采用手性固定相高效液相色谱拆分6种 α -芳基萘满酮类衍生物对映体的方法。考察了流动相中有机改性剂的种类和比例、柱温和流速对对映体分离的影响。结果显示6种化合物在异丙醇为改性剂的条件下均可获得较高的对映体分离度。热力学研究表明6种化合物对映体的手性拆分过程均受焓驱动影响,且低温有利于对映体分离。最终推荐分离化合物Ⅰ对映体的流动相是正己烷-异丙醇(90:10,v/v);分离化合物Ⅱ、Ⅲ、Ⅳ对映体的流动相是正己烷-异丙醇(99:1,v/v);分离化合物Ⅴ对映体的流动相是正己烷-异丙醇(85:15,v/v);分离化合物Ⅵ对映体的流动相是正己烷-异丙醇(80:20,v/v)。柱温为25℃,流速为1.0 mL/min。6种化合物对映体均可在Chiralpak IC手性固定相上得到完全分离,证明该色谱柱对6种化合物具有较高的对映体选择性。  相似文献   

10.
A reversed-phase high-performance liquid chromatographic method is described for the determination of hydroxy and peroxy acid derivatives of uroporphyrin in the plasma of patients with congenital erythropoietic porphyria. The porphyrins were extracted from the plasma with 20% trichloroacetic acid-dimethyl sulphoxide (1:1, v/v). The supernatant after centrifugation was chromatographed on a Hypersil-ODS column by gradient elution with 9% (v/v) acetonitrile in 1 M ammonium acetate buffer (pH 5.16) (solvent A) and 10% (v/v) acetonitrile in methanol (solvent B) as the gradient mixture. The method was also suitable for the preparative isolation of the porphyrins.  相似文献   

11.
An ion chromatographic method with conductivity detection for the simultaneous determination of ephedrine, pseudoephedrine and norephedrine was developed. A mixture of 2.0 mmol/L HNO3 and 2% (v/v) acetonitrile was used as eluent. The three ephedrine-like compounds were separated and determined within 20 min. The linear ranges were 0.08-50 microg/mL for ephedrine, 0.08-40 microg/mL for pseudoephedrine and 0.06-40 microg/mL for norephedrine. The detection limits were 0.03 microg/mL for ephedrine and pseudoephedrine, and 0.02 microg/mL for norephedrine. The method has been applied successfully to the determination of these sympathomimetics in pharmaceutical preparations and in Ephedra herbs.  相似文献   

12.
Gastrointestinal tract disorders constitute a heavy burden to healthcare providers. To eradicate Helicobacter pylori infection, different triple therapy protocols have been proposed. Among which are combinations of proton pump inhibitors (e.g., omeprazole), histamine-2 receptor antagonists (e.g., famotidine), along with antibiotics (e.g., amoxicillin). In this work, a sensitive and accurate high-performance thin-layer chromatographic method was developed for the simultaneous determination of amoxicillin, metronidazole, and famotidine in bulk powder and laboratory-prepared combined-tablet mixtures. Complete separation of the cited compounds was achieved using pre-coated silica gel plates with a mixture of methanol:chloroform:toluene:water:glacial acetic acid (5:2:1.5:0.5:0.1 v/v/v/v/v) as the mobile phase. The method was fully validated as per the international conference of harmonization guidelines. Good linearity, a correlation coefficient of 0.9991, was obtained in the concentration ranges 0.1–1.6 μg/band (amoxicillin), 0.1–0.9 μg/band (metronidazole), and 0.1–0.9 μg/band (famotidine). Since the method allowed the determination of the three compounds in combined tablets with a high degree of selectivity, accuracy, precision, with cost-effectiveness, it could be used for regular quality control. Moreover, the applicability of the proposed method was extended to the determination of the ternary mixture in simulated gastric juice. Method greenness was assessed using different green metrics.  相似文献   

13.
A high performance liquid chromatography (HPLC) method is presented for the determination of Chimassorb 944 in polymeric matrix. A reversed phase column octadecyl silane (ODS) is used as a stationary phase. As a mobile phase, a mixture of THF:methanol:triethanol amine (90:10:1.5) (v:v:w) is used. The HPLC system was equipped with an UV detector and the absorbance of the analyte was recorded at 240 nm. In the case of polymers, 0.5 g of them along with 100 mg Irganox 1010 (for preventing oxidation of Chimassorb 944) were dissolved in boiling xylene, and then extracted with sulfuric acid 1 M four times. The extract was neutralized with sodium hydroxide solution and the analyte was re-extracted into carbon tetrachloride and then injected to the HPLC system. This method is an accurate and relatively fast technique for determination of Chimassorb 944 in polymers.  相似文献   

14.
A method for the determination/identification of residual sulfadimidine (SDD) in milk and eggs by high-performance liquid chromatography (HPLC) with a photo-diode array detector was developed. The sample preparation was performed by shaking with a mixture of 20% (w/v) trichloroacetic acid-methanol (4:1, v/v) followed by ultra-filtration using Molcut II®. A LiChrospher® 100 RP-8 (e) column and a mobile phase of 4% (v/v) acetic acid solution-acetonitrile (6:4, v/v) were used. The average recoveries from spiked SDD samples were 80.8–88.0% with coefficients of variation of 2.8–5.5%. The limits of detection in milk and eggs were 0.01 μg/mL and 0.01 μg/g, respectively. The total time required for the analysis of one sample was less than 20 min.  相似文献   

15.
A new method that uses HPLC with a photochemical reactor for enhanced detection was developed and validated for the determination of aflatoxins in cassava flour. Samples were spiked with a mixture of four aflatoxins at 5, 10, and 20 microg/kg mixed with either 1 or 5 g NaCI and extracted with methanol-water (80 + 20, v/v) by shaking for 10 or 30 min. An immunoaffinity column was used for cleanup. HPLC with postcolumn derivatization, for enhancement of aflatoxin fluorescence, and fluorescence determination were used for quantitation of the toxin concentration. The method was validated for recovery, linearity, and precision at the three concentrations tested. Recovery ranges were 52-70, 69-85, and 80-89% for the spiking levels of 5.0, 10.0, and 20.0 microg/kg, respectively. It appears that the amount of salt (NaCl) and the shaking time are critical factors in this method; optimal performance was obtained when 1 g salt was used and the shaking time was 10 min. The good linearity and precision of the method allowed baseline separation from interferences, e.g., coumarins.  相似文献   

16.
A liquid chromatographic method for the determination of closantel residues in milk and tissues is developed and validated. An acetonitrile-acetone solution (80:20, v/v) is used for the extraction of closantel residues from milk and animal tissues, and the extract is purified by solid-phase extraction with Oasis MAX cartridges and a mixture of formic acid-acetonitrile (5:95, v/v) as the elution solution. A C(18) bonded silica column is used for chromatographic separation. The mobile phase consists of acetonitrile-water (85:15, v/v) containing 0.05% triethylamine at pH 2.5, adjusted with phosphoric acid with the flow-rate set at 1.0 mL/min. Using the fluorescence emission of closantel at lambda(ex) = 335 nm and lambda(ex) = 510 nm, the calibration curve is linear, with a correlation coefficient of 0.9999 over the concentration range of 10-5000 microg/kg for the tissue sample and 10-5000 microg/L for the milk sample. The detection limit (s/n = 3) is 3 microg/kg for tissue sample and 3 microg/L for milk sample. The intra- and inter-day repeatabilities are between 3.35-7.66% and 4.04-8.67%, respectively. The proposed method enables the quantitative determination of closantel residues at levels as low as 10 microg/kg in animal tissue samples and 10 microg/L in milk samples.  相似文献   

17.
A new high-performance liquid chromatography method for the quantitative determination of ethambutol hydrochloride in combination tablets is presented. Ethambutol is derivatized with phenylethylisocyanatate at room temperature (22 +/- 2 degrees C) for 5 min. Separation is performed by a C(18) column using methanol-water-glacial acetic acid (70:30:0.2, v/v/v) as the mobile phase. The method is linear for drug concentrations in the range of 20-120 microg/mL (r=0.9995). The intra- and inter-day precisions are lower than 1.46% and 2.22%, respectively. The average recovery of the samples at three levels is 99.8%. The results show that derivatization of ethambutol is stable at 30 degrees C for 24 h. This method is simple, rapid, and stable in the presence of common excipients and antituberculosis drugs in the tablets.  相似文献   

18.
A method for the determination/identification of residual sulfadimidine (SDD) in milk and eggs by high-performance liquid chromatography (HPLC) with a photo-diode array detector was developed. The sample preparation was performed by shaking with a mixture of 20% (w/v) trichloroacetic acid-methanol (4:1, v/v) followed by ultra-filtration using Molcut II?. A LiChrospher? 100 RP-8 (e) column and a mobile phase of 4% (v/v) acetic acid solution-acetonitrile (6:4, v/v) were used. The average recoveries from spiked SDD samples were 80.8–88.0% with coefficients of variation of 2.8–5.5%. The limits of detection in milk and eggs were 0.01 μg/mL and 0.01 μg/g, respectively. The total time required for the analysis of one sample was less than 20 min. Received: 7 October 1998 / Revised: 29 December 1998 / Accepted: 30 December 1998  相似文献   

19.
Ion chromatography of sulfide, sulfite, sulfate and thiosulfate in a mixture is often difficult because of instability of sulfide and sulfite, poor separation of sulfide from common anions such as bromide or nitrate and similar elution-times for sulfite and sulfate. An ion-pair chromatographic method for the determination of these sulfur anions has been established by stoichiometric conversion of sulfide and sulfite into stable thiocyanate and sulfate, respectively, prior to the chromatographic run. Sulfate, thiosulfate and thiocyanate were resolved on an octadecylsilica column with an acetonitrile-water mobile phase containing tetrapropylammonium salt (TPA) as an ion-paring reagent, and thiosulfate and thiocyanate in the effluent could be measured with a photometric detector (220 nm) and sulfate with a suppressed conductivity detector. When an acetonitrile-water (6:94, v/v) mobile phase (pH 5.0) containing 15 mM TPA and small amounts of acetic acid was used at a flow-rate of 0.6 ml min(-1), the three anions could be eluted within 32 min. Calibration plots of peak height versus concentration for sulfide (detected as thiocyanate) and thiosulfate gave straight lines up to 35 and 60 microM, respectively. The calibration plot for sulfide coincided with that obtained by using thiocyanate. A calibration plot for sulfite, measured as sulfate, was also linear up to 135 microM and was in accord with that of sulfate. Each calibration plot gave a correlation coefficient greater than 0.999. For six replicates obtained for a mixture of 30.0 microM sulfide, 50.0 microM sulfite, 50.0 microM sulfate and 20.0 microM thiosulfate, the proposed method gave a mean value of 30.1 microM with a standard deviation (SD) of 0.77 microM and a relative standard deviation (RSD) of 2.6% for sulfide, 101 microM (SD = 3.5 microM, RSD = 3.5%) for the total of sulfite and sulfate and 20.1 microM (SD = 0.44 microM, RSD = 2.2%) for thiosulfate. Recoveries for sulfide, sulfite plus sulfate, and thiosulfate in hot-spring water samples using the proposed method were found to be quantitative.  相似文献   

20.
建立了QuEChERS前处理技术结合超高效液相色谱-串联质谱(UHPLC-MS/MS)检测畜禽组织中6种黄曲霉毒素和杂色曲霉素残留的分析方法。样品经20 μL β-葡萄糖苷酶酶解和10 mL乙腈-水(84:16,v/v)提取,然后用1.0 g氯化钠和1.0 g无水硫酸镁净化、5 mL正己烷脱脂,最后采用1 mL含5 mmol/L乙酸铵的乙腈-水溶液(80:20,v/v)复溶。以甲醇和5 mmol/L乙酸铵为流动相,在多反应监测正离子模式下进行检测,采用基质匹配标准曲线外标法进行定量分析。结果显示,6种黄曲霉毒素和杂色曲霉素在各自的范围内线性关系良好,相关系数(R2)>0.99,检出限(LOD,S/N=3)为0.007~0.30 μg/kg,定量限(LOQ,S/N=10)为0.02~0.91 μg/kg,加标回收率为77.3%~118.5%(n=6)。该法简单、快速,灵敏度高,适用于不同畜禽产品中6种黄曲霉毒素和杂色曲霉素的确证分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏