首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Zhao S  Xia X  Yu G  Yang B 《Talanta》1998,46(5):845-850
A flow-injection method for the simultaneous determination of iron and zinc in the human hair with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) using a pH gradient technique has been developed. The linear range for the determination of iron is 0.1 approximately 1.8 mug ml(-1) and for zinc is 0.2 approximately 5.0 mug ml(-1). About 20 approximately 30 samples can be determined in 1 h. The proposed method is simple, rapid and accurate. It has been applied to the simultaneous determination of trace amounts of iron and zinc in the human hair with satisfactory results.  相似文献   

2.
A cationic exchanger paper is used to retain analytes in solution and, after drying, to analyze directly by measuring the UV-Vis absorbance of the paper. The method was applied to determination of iron using its known 1,10-phenanthroline complex. Using 100 ml of sample the applicable concentration range was between 1.0 and 10.0 ng/ml with a detection limit of 0.2 ng/ml and a RSD around 2%. The method was applied to determination of iron total in snow, human serum and wine.  相似文献   

3.
A flow injection-photometric method has been developed for the determination of iron(II+III). The method is based on the catalytic effect of iron(III) on the hydrogen peroxide oxidation of 3,3',5,5'-tetramethylbenzidine to form a blue compound (lambda(max)=650 nm). In this catalyzed reaction, 1,10-phenanthroline acted as an effective activator. Iron(II) is also determined, being oxidized by hydrogen peroxide. Calibration graphs for iron(II) and iron(III) obtained under the optimized conditions were identical with each other and linear in the range 0.2-200 ng ml(-1) with a detection limit of 0.05 ng ml(-1) iron. The reproducibility was satisfactory with a relative S.D. of 1.0% for ten determinations of 5 ng ml(-1) iron(III). The proposed method was successfully applied to the determination of iron in river and lake water samples and can be determined free iron species.  相似文献   

4.
A highly sensitive and selective second derivative spectrophotometric method has been developed for the determination of ruthenium and iron in mixtures. The method is based on the formation of the binary complexes of iron and ruthenium with 4,7-diphenyl-1,10-phenanthroline (bathophenanthroline) in the presence of ethyleneglycol. These complexes are formed at pH 4.0-6.0 upon heating at 90 degrees C for 60 min. The ternary perchlorate complexes are then separated by liquid-liquid extraction. The extracts were evaluated directly by derivative spectrophotometric measurement, using the zero-crossing approach for determination of both analytes. Ruthenium and iron were thus determined in the ranges 9.6-450 and 16.3-280 ng/ml, respectively, in the presence of one another. The detection limits achieved (3sigma) were found to be 2.9 ng/ml of ruthenium and 4.9 ng/ml of iron. The relative standard deviations were in all instances less than 1.5%. The proposed method was applied to the determination of both analytes in synthetic mixtures.  相似文献   

5.
Toral MI  Richter P  Rodríguez C 《Talanta》1997,45(1):147-153
A highly sensitive and selective second derivative spectrophotometric method has been developed for the determination of copper and iron in mixtures. The method is based on the separation of the analytes by liquid-liquid extraction as picrate ion pairs. Iron-picrate, reacts in the organic phase of DCE with 5-phenyl-3-(4-phenyl-2-pyridinyl)-1,2,4-triazine (PPT). Similarly the copper-picrate reacts with 2,9-dimethyl-4,7-diphenyl-1,10-phenantroline (bathocuproine). The extracts were evaluated directly by derivative spectrophotometric measurement, using the zero-crossing approach for determination of copper and graphic method for iron. Iron and copper were thus determined in the ranges 8-120 ng ml(-1) and 8-125 ng ml(-1), respectively, in the presence of one another. The detection limits achieved (3sigma) were 2.9 ng ml(-1) of iron and 2.8 ng ml(-1) of copper. The relative standard deviations were in all instances less than 2.1%. The proposed method was applied to the determination of both analytes in river and tap water and the results were consistent with those provided by the AAS standard method.  相似文献   

6.
Wang N  Liang W  Qi P 《Talanta》1993,40(6):897-899
A method is proposed for the simultaneous determination of copper and nickel by third-derivative spectrophotometry based on the absorption spectra of their complexes with cyanide ion in the ultraviolet range. The method allows the determination of 0.55-5.8 mug/ml of copper and 0.55-6.8 mug/ml of nickel. The relative standard deviation for 11 determinations of 1.5 mul/ml of copper and nickel were 0.78 and 0.72%, respectively. The detection limits were 0.10,mug/ml for nickel and 0.13 mug/ml for copper. The method has been applied to direct determination of copper and nickel in iron alloys and an aluminium alloy without any separation.  相似文献   

7.
建立了电感耦合等离子体原子发射光谱(ICP-AES)法测定铸造用硅砂中Fe_2O_3、Al_2O_3、CaO、MgO、TiO_2、K_2O、Na_2O的方法。研究了溶样方法的选择优化,采用硝酸、氢氟酸溶样,冒高氯酸处理,通过元素分析线的选择,基体和共存元素影响的消除,在最佳的仪器分析条件下得出了方法的线性范围、相关系数及检出限。用硅砂3个梯度含量的标准物质的分析结果评价方法的准确度和精密度。方法的检出限Fe为0.012μg/mL、Al为0.032μg/mL、Ca为0.27μg/mL、Mg为0.003 2μg/mL、Ti为0.002 1μg/mL、K为0.16μg/mL,Na为0.000 44μg/mL。5次数据的相对标准偏差说明方法稳定性较好。方法适用于铸造用硅砂中Fe_2O_3、Al_2O_3、CaO、MgO、TiO_2、K_2O、Na_2O含量的测定。  相似文献   

8.
《Analytical letters》2012,45(6):1225-1233
ABSTRACT

A simple method for the direct determination of trace molybdenum in low alloy steel and pure iron with selectivity and sensitivity is reported. In the presence of TritonX-100 and sulphuric-phosphoric acid medium, a new chromogenic reagent dimethoxyhydroxyphenyl-flurone (DMHPF) forms a red complex with molybdenum(VI). The molar absorptivity is obeyed from the range of 0? 8 μg/25 ml for molybdenum(VI). Most of metal ions and 35000-fold amounts of iron do not interfere with the determination of molybdenum. The proposed method has been successfully used for the determination of trace amounts of molybdenum in steel and pure iron specimens.  相似文献   

9.
A redox reaction of cysteine with iron(III) proceeds slowly in the presence of 1,10-phenanthroline (phen). However, this reaction is accelerated in the presence of copper(II) as a catalyst, producing an iron(II)-phen complex (lambda(max)=510 nm). A sensitive spectrophotometric flow-injection method is proposed for the determination of copper(II) based on its catalytic action on this redox reaction. The dynamic range was 0.1-10 ng ml(-1) of copper(II) with a relative standard deviation of 1.0% (n=10) for 1.0 ng ml(-1) of copper(II) at a sampling rate of 30 h(-1). The detection limit (S/N=3) is 0.04 ng ml(-1). The proposed method was successfully applied to the determination of copper in river water as a certified reference material.  相似文献   

10.
A flow injection procedure for the sequential spectrophotometric determination of iron(II) and iron(III) in pharmaceutical products is described. The method is based on the catalytic effect of iron(II) on the oxidation of iodide by bromate at pH = 4.0. The reaction was monitored spectrophotometrically by measuring the absorbance of produced triiodide ion at 352 nm. The activating effect for the catalysis of iron(II) was extremely exhibited in the presence of oxalate ions, while oxalate acted as a masking agent for iron(III). The iron(III) in a sample solution could be determined by passing through a Cd-Hg reductor column introduced in the FIA system to reduce iron(III) to iron(II), which allows total iron determination. Under the optimum conditions, iron(II) and iron(III) could be determined over the range of 0.05 - 5.0 and 0.10 - 5.0 microg ml(-1), respectively with a sampling rate of 17 +/- 5 h(-1). The experimental limits of detection were 0.03 and 0.04 microg ml(-1) for iron(II) and iron(III), respectively. The proposed method was successfully applied to the speciation of iron in pharmaceutical products.  相似文献   

11.
Nakano S  Tsujii K  Kawashima T 《Talanta》1995,42(8):1051-1056
A highly sensitive photometric flow-injection method is described for the determination of iron(II, III) based on the catalytic action on the oxidative coupling of N-phenyl-p-phenylenediamine with m-phenylenediamine in the presence of hydrogen peroxide. The sensitivity of the method was enhanced by the addition of Tween 80 as a surfactant. The dynamic range was 0.5-30 ng/ml of iron(II, III) with the relative standard deviations below 3% at a sampling rate of 30 h(-1). The proposed method was subject to few interferences from coexisting metal ions and was successfully applied to the determination of iron in natural water samples.  相似文献   

12.
First- and second-derivative spectrophoto-metric methods for the simultaneous determination of aluminium and iron in their mixtures are described. The methods are based on the colored complexes formed by aluminium and iron with hematoxylin in the presence of cetyltrimethylammonium bromide as a surfactant. The zero-crossing method has been utilized to measure the first- and second-derivative value of the derivative spectrum. Aluminium (0.05-1 microg ml(-1)) could be determined in the presence of iron (0.09-1.6 microg ml(-1)) and vice versa. The detection limits of aluminium and iron are 0.01 and 0.09 microg ml(-1), respectively in the first-derivative mode and 0.014 and 0.1 microg ml(-1) in the second-derivative mode. The proposed method has been applied to the simultaneous determination of aluminium and iron in glasses, phosphate rocks, cement and magnesite alloy.  相似文献   

13.
A frequency-doubled, flashlamp-pumped tunable dye laser is used to excite the Stokes direct-line atomic fluorescence transition of iron (296.7 nm/373.5 nm). Limits of detection are determined with single (0.6 ng/ml) and multipass (0.2 ng/ml) and with a l s time constant (a 0.06 ng/ml limit detection is obtained with an 8 s time constant). Noise sources limiting precision at both low (background flame emission shot and flicker noise) and high concentrations (laser pulse to pulse variability) concentrations are investigated and the technique is used for the determination of iron in simulated fresh water NBS SRM-1643), unalloyed copper (NBS SRM-394) and fly ash (NBS SRM-1633).  相似文献   

14.
A method is proposed for the simultaneous determination of iron(III) and molybdenum(VI) by first-derivative spectrophotometry based on the absorption spectra of their complexes with morin in the presence of a cationic surfactant. The zero-crossing measurement technique is found sutiable for the direct measurement of the first-derivative value at the specified wavelengths. Iron(III) (0.9-1.5 mug ml(-1)) and molybdenum(VI) (0.3-4.2 mug ml(-1)) in different ratios have been determined simultaneously. A critical evaluation of the proposed method is performed by statistical analysis of the experimental data. The method was applied to determine iron and molybdenum in different alloys.  相似文献   

15.
Summary A TLC method for the separation of quantitative determination of copper and iron in cotton material is described. The optimal solvent system is 9:2:1 (v/v), ethanol-nitric acid-hydrochloric acid and the locating reagent is Na-diethyldithiocarbamate. Regression analysis shows that the most precise results can be obtained for the concentration range of 0.0400–0.0800 mg/ml of iron and copper.  相似文献   

16.
Guo-Zhong D  Zhi-Liang J 《Talanta》1989,36(11):1107-1110
The catalytic effect of iron(III) on the oxidation of reduced Rhodamine B with hydrogen peroxide in acetic acid medium has been studied. The reaction is highly accelerated by potassium thiocyanate. A new catalytic kinetic spectrophotometric method for the determination of iron has been developed. Iron(III) can be determined by the fixed time method with a detection limit of 4 x 10(-11) g/ml.  相似文献   

17.
《Analytical letters》2012,45(14):2563-2571
Abstract

A DPCSV procedure for the determination of selenium (IV) with a prior preconcentrative coprecipitation on iron (III) hydroxide has been developed. The experimental conditions for coprecipitation of selenium (IV) onto iron (III) hydroxide, viz. pH, iron (III) concentration, volume of aqueous phase and selenium concentration, were optimized. The coprecipitated selenium (IV) is dissolved in 10 ml of 0.1 M HCl and analysed using DPCSV in the presence of copper (II). Selenium concentrations as low as 10–100 ng present in 500 ml of the aqueous phase could be determined. The method is precise and has been applied to the analysis of sea water and reference material samples.  相似文献   

18.
Mudasir  Yoshioka N  Inoue H 《Talanta》1997,44(7):1195-1202
A reversed phase ion-paired chromatographic method that can be used to determine trace amounts of iron (II,III), nickel (II) and copper (II) was developed and applied to the determination of iron (II) and iron (III) levels in natural water. The separation of these metal ions as their 4,7-diphenyl-1,10-phenanthroline (bathophenanthroline) chelates on an Inertsil ODS column was investigated by using acetonitrile-water (80/20, v/v) containing 0.06 M perchloric acid as mobile phase and diode array spectrophotometric detection at 250-650 nm. Chromatographic parameters such as composition of mobile phase and concentration of perchloric acid in mobile phase were optimized. The calibration graphs of iron (II), nickel (II) and copper (II) ions were linear (r > 0.991) in the concentration range 0-0.5, 0-2.0 and 0-4.0 mug ml(-1), respectively. The detection limit of iron (II), nickel (II) and copper (II) were 2.67, 5.42 and 18.2 ng ml(-1) with relative standard deviation (n = 5) of 3.11, 5.81 and 7.16% at a concentration level of 10 ng ml(-1) for iron (II) and nickel (II) and 25 ng ml(-1) for copper (II), respectively. The proposed method was applied to the determination of iron(II) and iron(III) in tap water and sea water samples without any interference from other common metal ions.  相似文献   

19.
A sequential injection analysis (SIA) assembly for the atomic absorption determination of Fe(III) in natural waters is proposed. Iron is preconcentrated on a microcolumn packed with a chelating resin (Chelex 100) that is inserted in the manifold. The sample is passed through the column and the iron retained by the resin is subsequently eluted with 2 M HNO(3). The proposed SIA system affords automatic preconcentration, elution, detection of Fe(III), data acquisition and treatment. When 9 ml of iron solution containing 0.4 or 1 mg l(-1) was passed through the resin, the retention efficiency was 93.1 +/- 0.6 and 7.4 +/- 3.0% respectively, and when 27 ml of iron solution of 0.2 mg l(-1) was preconcentrated, the retention was 8.4 +/- 2.9%. The detection limits thus achieved is 12 mug l(-1) when 9 ml of sample are preconcentrated and 6 mug l(-1) for 27 ml.  相似文献   

20.
Summary A method is proposed for the extractive-photometric determination of g amounts of iron in ground water based on the complex formation of ferrous iron with phenyl-2-pyridylketoxime. The limit of identification is 0.01 mg Fe/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号