首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background  

Propriospinal neurons, with axonal projections intrinsic to the spinal cord, have shown a greater regenerative response than supraspinal neurons after axotomy due to spinal cord injury (SCI). Our previous work focused on the response of axotomized short thoracic propriospinal (TPS) neurons following a low thoracic SCI (T9 spinal transection or moderate spinal contusion injury) in the rat. The present investigation analyzes the intrinsic response of cervical propriospinal neurons having long descending axons which project into the lumbosacral enlargement, long descending propriospinal tract (LDPT) axons. These neurons also were axotomized by T9 spinal injury in the same animals used in our previous study.  相似文献   

2.

Introduction

We investigated microstructural changes in the spinal cord, separately for white matter and gray matter, in patients with cervical spondylosis by using diffusional kurtosis imaging (DKI).

Methods

We studied 13 consecutive patients with cervical myelopathy (15 affected sides and 11 unaffected sides). After conventional magnetic resonance (MR) imaging, DKI data were acquired by using a 3 T MR imaging scanner. Values for fractional anisotropy (FA), apparent diffusion coefficient (ADC), and mean diffusional kurtosis (MK) were calculated and compared between unaffected and affected spinal cords, separately for white matter and gray matter.

Results

Tract-specific analysis of white matter in the lateral funiculus showed no statistical differences between the affected and unaffected sides. In gray matter, only MK was significantly lower in the affected spinal cords than in unaffected spinal cords (0.60 ± 0.18 vs. 0.73 ± 0.13, P = 0.0005, Wilcoxon’s signed rank test).

Conclusions

MK values in the spinal cord may reflect microstructural changes and gray matter damage and can potentially provide more information beyond that obtained with conventional diffusion metrics.  相似文献   

3.

Object

Although three-dimensional (3D), high-spatial resolution susceptibility-weighted imaging (SWI) appears to be valuable in the evaluation of central nervous system gliomas, several evaluation methods are proposed in the literature. The purpose of this study was to evaluate the use of 3D SWI for grading intracranial gliomas with various analysis methods.

Materials and Methods

Twenty-three patients suspected of having gliomas participated in this study. SWI was performed in addition to conventional MR sequences. In 15 cases, post-gadolinium enhanced SWI was also obtained. Imaging evaluation criteria were conventional grade, hypointensity ratio in the tumor-dominant structure of hypointensity on SWI (hemorrhage or vascular structure) and presence of abnormal enhancement surrounding the tumor.

Results

Mean grading scores of conventional grade showed no statistically significant difference among WHO grades. Mean grading scores of hypointensity ratios in the tumor were higher for WHO Grades 3 and 4 than for lower grade tumors (P=.05, Mann–Whitney U test). Hemorrhagic foci were more frequently seen in the higher grade tumor. Post-contrast susceptibility-weighted images of five of 11 WHO Grade 3 and 4 cases showed bright enhancement surrounding the tumor, suggesting a breakdown of the blood–brain barrier.

Conclusions

SWI at 3 T may be a useful method to analyze the structural characteristics of gliomas and to evaluate pathology in vivo. Assessment of hypointensity ratios in the glioma was the most preferable method in grading glioma. However, more studies, specifically concerning a suitable method for image analysis, are needed to establish SWI at 3 T as a useful tool in clinical routine.  相似文献   

4.

Background  

Glutamergic excitotoxicity has been shown to play a deleterious role in the pathophysiology of spinal cord injury (SCI). The aim of this study was to investigate the neuroprotective effect of dizocilpine maleate, MK801 (2 mg/Kg, 30 min and 6 hours after injury) in a mice model of SCI. The spinal cord trauma was induced by the application of vascular clips to the dura via a four-level T5-T8 laminectomy.  相似文献   

5.

Purpose

Although functional magnetic resonance imaging (fMRI) has revealed that spinal cord injury (SCI) causes anomalous changes in task-induced brain activation, its effect during the resting state remains unclear. The aim of this study is to explore the changes of the brain resting-state function in non-human primates with unilateral SCI.

Materials and methods

Eleven adult female rhesus monkeys were subjected to resting-state fMRI: five with unilateral thoracic SCI and six healthy monkeys, to obtain the fractional amplitude of low-frequency fluctuations (fALFF) of the blood oxygenation level-dependent (BOLD) contrast signal to determine the influence of SCI on the cerebral resting-state function.

Results

The SCI-induced fALFF vary significantly in several encephalic regions, including the left cerebellum, the left thalamus, the right lateral geniculate nucleus, the right superior parietal lobule, and the posterior cingulate gyrus.

Conclusion

Analysis of the resting-state fMRI provides evidence of abnormal spontaneous brain activations in primates with SCI, which may help us understand the pathophysiologic mechanisms underlying the changes in neural plasticity in the central nervous system after SCI.  相似文献   

6.

Purpose

To improve signal-noise-ratio of in vivo mouse spinal cord diffusion tensor imaging using-phase aligned multiple spin-echo technique.

Material and methods

In vivo mouse spinal cord diffusion tensor imaging maps generated by multiple spin-echo and conventional spin-echo diffusion weighting were examined to demonstrate the efficacy of multiple spin-echo diffusion sequence to improve image quality and throughput. Effects of signal averaging using complex, magnitude and phased images from multiple spin-echo diffusion weighting were also assessed. Bayesian probability theory was used to generate phased images by moving the coherent signals to the real channel to eliminate the effect of phase variation between echoes while preserving the Gaussian noise distribution. Signal averaging of phased multiple spin-echo images potentially solves both the phase incoherence problem and the bias of the elevated Rician noise distribution in magnitude image. The proposed signal averaging with Bayesian phase-aligned multiple spin-echo images approach was compared to the conventional spin-echo data acquired with doubling the scan time. The diffusion tensor imaging parameters were compared in the mouse contusion spinal cord injury. Significance level (p-value) and effect size (Cohen’s d) were reported between the control and contused spinal cord to inspect the sensitivity of each approach in detecting white matter pathology.

Results

Compared to the spin-echo image, the signal-noise-ratio increased to 1.84-fold using the phased image averaging and to 1.30-fold using magnitude image averaging in the spinal cord white matter. Multiple spin-echo phased image averaging showed improved image quality of the mouse spinal cord among the tested methods. Diffusion tensor imaging metrics obtained from multiple spin-echo phased images using three echoes and two averages closely agreed with those derived by spin-echo magnitude data with four averages (two times more in acquisition time). The phased image averaging correctly reflected pathological features in contusion spinal cord injury.

Conclusion

Our in vivo imaging results indicate that averaging the phased multiple spin-echo images yields an 84% signal-noise-ratio increase over the spin-echo images and a 41% gain over the magnitude averaged multiple spin-echo images with equal acquisition time. Current results from the animal model of spinal cord injury suggest that the phased multiple spin-echo images could be used to improve signal-noise-ratio.  相似文献   

7.

Background

The goal of the study was to assess a T2*-weighted MRI sequence for the ability to identify hepatocellular carcinoma (HCC).

Methods

Hepatic iron deposition, which is common in chronic liver disease (CLD), may increase the conspicuity of HCC on GRE imaging due to increased T2* signal decay in liver parenchyma. In this study, a breath-hold T2*-weighted MRI sequence was evaluated by a blinded observer for HCC and the results compared to a reference standard of gadolinium-enhanced MRI in these same patients. Forty-one patients (mean age 56.2 years; 17 females) were included in this approved, retrospective study.

Results

By the reference standard, 14 of 41 patients had a total of 25 HCCs. The sensitivity of the T2*-weighted MR sequence for identifying HCC, per lesion, was 60%, while the specificity was 100%. There was a significantly lower T2* value of liver parenchyma in patients with HCC identified by the T2*-weighted sequence than in those with HCCs which were not identified by the T2*-weighted sequence (27.8±2.2 vs. 21.9±2.1 ms; P=.02).

Conclusions

A T2*-weighted MRI sequence can identify HCC in patients with CLD. This technique may be beneficial for imaging of patients contraindicated for gadolinium.  相似文献   

8.

Purpose

To describe the paradoxical high signal intensity of hepatocellular carcinoma (HCC) in the hepatobiliary phase on gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI).

Materials and Methods

A database search was performed to identify cases of HCC that showed unusual prolonged enhancement in the hepatobiliary phase of Gd-EOB-DTPA MRI. All patients received 3.0-T liver MRI including precontrast T1-weighted images, T2-weighted images and a post Gd-EOB-DTPA-enhanced dynamic study. The signal intensity of HCC was measured at pre-enhanced, arterial, portal, delayed and hepatobiliary phase using regions of interest. Radiologic and pathologic correlation was performed for the paradoxically prolonged enhancing portion of HCC in the hepatobiliary phase.

Results

Four patients (all male, age range 44-70; mean 57.5 years) were included in this study. All patients showed HCC lesions that were low signal intensity (SI) on T1-WI, high SI on T2-WI, enhanced in arterial phase, and washed-out in delayed phase. All cases showed paradoxically high SI in hepatobiliary phase, which was unusual for HCC. Pathologically, they were all diagnosed as well-differentiated HCC with prominent cytoplasm and a bile secreting appearance.

Conclusion

HCC may demonstrate the prolonged high signal intensity at the hepatobiliary phase on Gd-EOB-DTPA enhanced MRI. These HCCs tended to be highly differentiated and to have prominent bile secretion.  相似文献   

9.

Purpose

This retrospective study was designed to evaluate the apparent diffusion coefficient (ADC) of line scan diffusion images (LSDI) in normal prostate and prostate cancer. Single-shot echo planner images (SS-EPI) were used for comparison.

Materials and Methods

Twenty prostate tumors were examined by conventional MRI in 14 patients prior to radical prostatectomy. All patients were examined with a 1.5-T MR imager (Signa CV/i ver. 9.1 GE Medical System Milwaukee, WI, USA). Diffusion-weighted MR imaging (DWI) using LSDI was performed with a pelvic phased-array coil, with b values of 5 and 800 s/mm2. DWI using SS-EPI was performed with a body coil, with b values of 0 and 800 s/mm2. The ADCs of each sequence for 14 normal prostate and 20 prostate cancers were histopathologically assessed. Signal-to-noise ratio (SNR) on DWI was estimated and compared for each sequence.

Results

The mean ADCs (±S.D.) of normal peripheral zones (PZ), transition zones (TZ) and cancer (in 10−3 mm2/s) that used LSDI were 1.42±0.12, 1.23±0.10 and 0.79±0.19, respectively. Those that used SS-EPI were 1.76±0.26, 1.38±0.20 and 1.05±0.27, respectively. Using unpaired t test (P<.05), we found a significant difference in each sequence between normal tissue (both PZ and TZ) and the cancer. Paired t test (P<.05) also registered a significant difference between LSDI and SS-EPI. Mean SNR for DWI using LSDI was 16.49±5.03, while the DWI using SS-EPI was 18.85±9.26. The difference between the SNR of each sequence was not statistically significant by paired t test.

Conclusion

We found that ADCs using LSDI and SS-EPI showed similar tendencies in the same patients. However, in all regions, LSDI ADCs had smaller standard deviations than SS-EPI ADCs.  相似文献   

10.

Purpose

The purpose of this work is to characterize the noise in spinal cord functional MRI, assess current methods aimed at reducing noise, and optimize imaging parameters.

Methods

Functional MRI data were acquired at multiple echo times and the contrast-to-noise ratio (CNR) was calculated. Independently, the repetition time was systematically varied with and without parallel imaging, to maximize BOLD sensitivity and minimize type I errors. Noise in the images was characterized by examining the frequency spectrum, and investigating whether autocorrelations exist. The efficacy of several physiological noise reduction methods in both null (no stimuli) and task (thermal pain paradigm) data was also assessed. Finally, our previous normalization methods were extended.

Results

The echo time with the highest functional CNR at 3 Tesla is at roughly 75 msec. Parallel imaging reduced the variance and the presence of autocorrelations, however the BOLD response in task data was more robust in data acquired without parallel imaging. Model-free based approaches further increased the detection of active voxels in the task data. Finally, inter-subject registration was improved.

Conclusions

Results from this study provide a rigorous characterization of the properties of the noise and assessment of data acquisition and analysis methods for spinal cord and brainstem fMRI.  相似文献   

11.
In the traumatically injured spinal cord, decreased perfusion is believed to contribute to secondary tissue damage beyond the primary mechanical impact, and restoration of perfusion is believed to be a promising therapeutic target. However, methods to monitor spinal cord perfusion non-invasively are limited. Perfusion magnetic resonance imaging (MRI) techniques established for the brain have not been routinely adopted to the spinal cord. The purpose of this study was to examine the relationship between spinal cord blood flow (SCBF) and injury severity in a rat thoracic spinal cord contusion injury (SCI) model using flow-sensitive alternating inversion recovery (FAIR) with two variants of the label position. SCBF as a marker of severity was compared to T1 mapping and to spinal cord-optimized diffusion weighted imaging (DWI) with filtered parallel apparent diffusion coefficient. Thirty-eight rats underwent a T10 contusion injury with varying severities (8 sham; 10 mild; 10 moderate; 10 severe) with MRI performed at 1 day post injury at the lesion site and follow-up neurological assessments using the Basso, Beattie, Bresnahan (BBB) locomotor scoring up to 28 days post injury. Using whole-cord regions of interest at the lesion epicenter, SCBF was decreased with injury severity and had a significant correlation with BBB scores at 28 days post injury. Importantly, estimates of arterial transit times (ATT) in the injured spinal cord were not altered after injury, which suggests that FAIR protocols optimized to measure SCBF provide more value in the context of acute traumatic injury to the cord. T1-relaxation time constants were strongly related to injury severity and had a larger extent of changes than either SCBF or DWI measures. These findings suggest that perfusion decreases in the spinal cord can be monitored non-invasively after injury, and multi-parametric MRI assessments of perfusion, diffusion, and relaxation capture unique features of the pathophysiology of preclinical injury.  相似文献   

12.
Forty-one patients with suspected cervical spine disorders were studied using multislice gradient echo imaging (GE) technique, with a 1.5-T system. The images were compared to cardiac-gated spin echo (CGSE) images in the diagnosis of suspected cord and spinal disorders. Images were graded for ability to detect cord lesion, cord-CSF contrast, CSF-bone contrast and contrast between CSF and extradural abnormality. The signal-to-noise ratio and contrast-to-noise ratio were used to compare images. There was 44% decrease in contrast between cord lesion and normal cord on GE when compared to CGSE, except for spinal cord hemorrhage. There was a 40% improvement between bone and CSF contrast on GE compared to CGSE. GE images were significantly better qualitatively as well as quantitatively in the detection of extradural lesions. This effect was more marked in axial plane where CGSE images are extremely suboptimal. CGSE images are better than GE for spinal cord lesions, while GE are superior in the diagnosis of degenerative disease in the cervical spine.  相似文献   

13.

Purpose

To determine the feasibility of using R2? map MRI for pretreatment diagnosis and monitoring of tumor response to neoadjuvant chemotherapy (NAC) in patients with breast cancer.

Material and Methods

Twenty-eight women with breast cancer, as evidenced by pathology, underwent MR imaging prior to and after chemotherapy. All patients were examined by conventional MRI and R2? map imaging. Subjects were divided into major histological response (MHR) and non-major histological response (NMHR) groups. Mean R2? values of cancerous and normal glandular tissues were measured before and following NAC. Differences in R2? and ΔR2?% values between these two groups were compared with paired or independent t tests. The relationship between ΔR2?% and histological response was examined using Spearman's correlation test.

Results

Before NAC, the average R2? values in carcinoma were lower than in normal glandular tissue (P<.05). After two to four cycles of NAC, the R2? values in carcinoma were increased (P<.05 ), but this change was not significant in normal glandular tissue. After NAC, ΔR2?% was significantly higher in MHR as compared to NMHR (P<.05). The ΔR2?% correlated with the histological response (r=0.581, P<.01).

Conclusion

In women undergoing NAC for breast cancer treatment, R2? and ΔR2?% appear to provide predictive information of tumor response which is probably associated with changes in tumor angiogenesis and tissue oxygenation. R2? map imaging of breasts may therefore be useful in monitoring tumor response to NAC.  相似文献   

14.

Background

Blood-oxygen-level-dependent (BOLD) magnetic resonance imaging (MRI) can provide regional measurements of oxygen content using deoxyhemoglobin paramagnetic characteristics. The apparent relaxation rate or R2*(=1/T2*) can be determined from the slope of log (intensity) versus echo time and is directly proportional to the tissue content of deoxyhemoglobin. Thus, as the level of deoxyhemoglobin increases, T2* will decrease, leading to an increase in R2*. Chronic kidney disease (CKD) can affect oxygenation levels in renal parenchyma, which influences the clinical course of the disease. The goal of this study was to detect and assess renal oxygenation levels in CKD using BOLD MRI.

Methods

Fifteen healthy subjects and 11 patients with CKD underwent a renal scan using multigradient-recalled-echo sequence with eight echoes. R2* (1/s) of the renal cortex and medulla was measured on BOLD images. Of the 11 patients, nine had biopsy-proven chronic glomerulonephritis, and two had a similar diagnosis based on clinical symptoms and investigations.

Results

Mean medullary R2* (MR2*) and cortex R2* (CR2*) levels were significantly higher in patients (22 kidneys, MR2*=24.79±4.84 s−1, CR2*=18.97±2.72 s−1) than in controls (30 kidneys, MR2*=19.98±1.19 s−1, CR2*=16.03±1.23 s−1) (P<.01), and MR2* was increased more than CR2*. Medullary to cortical R2* ratios (MCR2*) of patients were significantly increased when compared with those of controls (P<.01). In the patient group, estimated glomerular filtration rate levels were greater than or equal to 60 ml/min/1.73 m2 in six patients (12 kidneys), whose MR2* and CR2* were also significantly higher than those of controls (P<.01). Serum creatinine levels were normal in seven patients (14 kidneys), whose MR2*, CR2* and MCR2* were also higher than those of controls (P<.01).

Conclusions

BOLD MRI can be used to evaluate changes in renal oxygenation in CKD, suggesting that it has the potential to be an excellent noninvasive tool for the evaluation of renal function.  相似文献   

15.

Purpose

To examine mesenchymal stem cell (MSC) labeling with micrometer-sized iron oxide particles (MPIOs) for magnetic resonance imaging (MRI)-based tracking and its application to monitoring articular cartilage regeneration.

Methods

Rabbit MSCs were labeled using commercial MPIOs. In vitro MRI was performed with gradient echo (GRE) and spin echo (SE) sequences at 3T and quantitatively characterized using line profile and region of interest analysis. Ex vivo MRI of hydrogel-encapsulated labeled MSCs implanted within a bovine knee was performed with spoiled GRE (SPGR) and T sequences. Fluorescence microscopy, labeling efficiency, and chondrogenesis of MPIO-labeled cells were also examined.

Results

MPIO labeling results in efficient contrast uptake and signal loss that can be visualized and quantitatively characterized via MRI. SPGR imaging of implanted cells results in ex vivo detection within native tissue, and T imaging is unaffected by the presence of labeled cells immediately following implantation. MPIO labeling does not affect quantitative glycosaminoglycan production during chondrogenesis, but iron aggregation hinders extracellular matrix visualization. This aggregation may result from excess unincorporated particles following labeling and is an issue that necessitates further investigation.

Conclusion

This study demonstrates the promise of MPIO labeling for monitoring cartilage regeneration and highlights its potential in the development of cell-based tissue engineering strategies.  相似文献   

16.

Objectives

To evaluate the performance of region-of-interest (ROI)-based MRI R2* measurements by using the first-moment noise-corrected model (M1NCM) to correct the non-central Chi noise in magnitude images from phased arrays for hepatic iron content (HIC) assessment.

Methods

R2* values were quantified using the M1NCM model. Three approaches were employed to determine the representative R2*: fitting of the ROI-averaged signal (average-then-fit, ATF); outputting the median and mean of R2*s from the pixel-wise fitting of decay signals within the ROI (denoted as PWFmed and PWFmea, respectively). The accuracy and precision of the three approaches were evaluated on synthesized data. The agreement among these approaches and their intra- and inter-observer reproducibility were assessed on 105 thalassaemia major patients.

Results

Simulations showed that ATF consistently yielded the highest accuracy and precision at varying noise levels. By contrast, PWFmed and PWFmea slightly and significantly overestimated high R2* at poor signal-to-noise ratios, respectively. Patient study showed that ATF agreed well with PWFmed, whereas PWFmea produced high R2* measurements for patients with severe HIC. No significant difference was observed in the reproducibility of the three approaches.

Conclusions

PWFmea tends to overestimate high R2*, whereas ATF and PWFmed can produce more accurate R2* measurements for HIC assessment.  相似文献   

17.

Purpose

To investigate the feasibility of combining GESFIDE with PROPELLER sampling approaches for simultaneous abdominal R2 and R2* mapping.

Materials and Methods

R2 and R2* measurements were performed in 9 healthy volunteers and phantoms using the GESFIDE-PROPELLER and the conventional Cartesian-sampling GESFIDE approaches.

Results

Images acquired with the GESFIDE-PROPELLER sequence effectively mitigated the respiratory motion artifacts, which were clearly evident in the images acquired using the conventional GESFIDE approach. There was no significant difference between GESFIDE-PROPELLER and reference MGRE R2* measurements (p = 0.162) whereas the Cartesian-sampling based GESFIDE methods significantly overestimated R2* values compared to MGRE measurements (p < 0.001).

Conclusion

The GESFIDE-PROPELLER sequence provided high quality images and accurate abdominal R2 and R2* maps while avoiding the motion artifacts common to the conventional Cartesian-sampling GESFIDE approaches.  相似文献   

18.
The purpose of this study is to report the significant differences found in the identification of lesions in cervical spinal cord of two patients with multiple sclerosis when using the BLADE T2-TSE and BLADE T2-TIRM sequences as opposed to the conventional T2-TSE and T2-TIRM sequences for sagittal acquisition at 1.5 T. In both patients, one more lesion was identified with the BLADE sequences than with the conventional ones. Consequently, we suggest the use of BLADE T2-TSE and BLADE T2-TIRM sequences in place of conventional ones for sagittal examination of the cervical spinal cord of multiple sclerosis patients. The advantages of ΤΙRΜ to reveal the pathology of the cervical spinal cord and the advantage of BLADE sequences to improve image quality should be combined in a sequence that could be ideal for cervical spinal cord examinations.  相似文献   

19.

Background

Since the advent of magnetic resonance imaging, metal artifacts have posed an important diagnostic problem in different fields of medicine. However, this has not been systematically studied in patients undergoing surgery for brain tumors.

Objective

This study was planned to assess whether metal artifacts can occur in patients undergoing brain surgery without metallic implants.

Methods

Of 40 individuals who could be included because of having a pre- and postoperative MRI and a postoperative computed tomography (CT) scan or a conventional skull X-ray for the detection of metallic artifacts, 26 patients agreed to participate in this study and gave informed consent.

Results

Twenty-six subjects, 12 males and 14 females, with an age range of 12 to 54 years, were included in the study. Four patients were found to have gross metal particles in their postoperative brain CTs and were excluded. Of the remaining 22 subjects, 7 patients (31.8%) had metallic artifacts.

Conclusion

Our study showed that simple bone drilling or chiseling during surgical manipulation of skull bones may result in separation of very tiny metal particles which can remain in the surgical site and cause artifacts in postoperative MRIs. This finding appeared to be independent of factors such as age, sex, tumor/incision site, tumor size, pathologic tumor type, total radiation dose, operation–MRI time interval and sequence of MRI.  相似文献   

20.

Purpose

The aim of this study was to determine the adequate MR sequence for the lesion conspicuity of hepatocellular lesions with increased iron uptake on superparamagnetic iron oxide (SPIO)-enhanced MRI.

Materials and Methods

SPIO-enhanced MRI was performed using a 1.5-T system. Among 25 patients with hypovascular hepatocellular nodules on contrast-enhanced dynamic CT (no early enhancement at arterial phase and hypoattenuation at equilibrium phase), 39 lesions with increased iron uptake on SPIO-enhanced MRI were evaluated. SPIO-enhanced MRI included (1) T1-weighted in-phase gradient recalled echo (GRE) images, (2) T2-weighted fast spin echo (FSE) images, (3) T2*-weighted GRE with moderate TE (7 ms) and (4) long TE (12 ms). The lesion-to-liver contrast-to-noise ratios of the hepatocellular nodule and the signal-to-noise ratio (SNR) of the hepatic parenchyma were calculated by one radiologist for a quantitative assessment. MR images were reviewed retrospectively by two independent radiologists to compare the subjective lesion conspicuity in each image set based on a four-point rating scale.

Result

The mean lesion-to-liver contrast-to-noise ratios with T2*-weighted GRE with moderate TE (7 ms) was highest (5.79±3.71) and was significantly higher than those with T1-weighted, in-phase images (3.79±3.23, P<.01), T2-weighted images (2.72±1.52, P<.001) and T2*-weighted GRE with long TE (12 ms) (3.93±2.69, P<.05). The subjective rating of lesion conspicuity was best on the T2*-weighted GRE with moderate TE (7 ms), followed by that on the T2*-weighted GRE with moderate TE (7 ms; P<.05).

Conclusion

T2*-weighted GRE sequence with moderate TE (7 ms) showed high lesion-to-liver contrast-to-noise ratios in hepatocellular lesions with increased iron uptake on SPIO-enhanced MRI, indicating better lesion conspicuity of hypointense hepatocellular nodules in cirrhosis or chronic hepatitis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号