首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Dynamic magnetic resonance microscopy of flour dough fermentation   总被引:2,自引:0,他引:2  
Magnetic resonance microscopy was carried out at 9.4 T with a voxel volume of 117 x 117 x 500 microm(3) and temporal resolution was adjusted to 8.5 min for a dynamic follow-up of bread dough fermentation during 2 h at a constant temperature of 30 degrees C. An image analysis procedure based on gray levels mathematical morphology routines was performed to assess bubble distribution and cell wall thickness inside the imaged bread dough. The evolution of the extracted curves allows one to characterize quantitatively the amount of bubbles and their growth. Using this procedure, different bread doughs were examined to determine the impact of dough composition on the structure modification during fermentation.  相似文献   

2.
Magnetic resonance imaging has proven its potential application in bread dough and gas cell monitoring studies, and dynamic processes such as dough proving and baking can be monitored. However, undesirable magnetic susceptibility effects often affect quantification studies, especially at high fields. A new low-field method is presented based on local assessment of porosity in spin-echo imaging, local characterization of signal loss in gradient-echo imaging and prediction of relaxation times by simulation to estimate bubble radii in bread dough during proving. Maps of radii showed different regions of dough constituting networks which evolved during proving. Mean radius and bubble distribution were assessed during proving.  相似文献   

3.
Paramagnetic manganese (II) can be employed as a calcium surrogate to sensitize magnetic resonance microscopy (MRM) to the processing of calcium during bone formation. At high doses, osteoblasts can take up sufficient quantities of manganese, resulting in marked changes in water proton T(1), T(2) and magnetization transfer ratio values compared to those for untreated cells. Accordingly, inductively coupled plasma mass spectrometry (ICP-MS) results confirm that the manganese content of treated cell pellets was 10-fold higher than that for untreated cell pellets. To establish that manganese is processed like calcium and deposited as bone, calvaria from the skull of embryonic chicks were grown in culture medium supplemented with 1 mM MnCl(2) and 3 mM CaCl(2). A banding pattern of high and low T(2) values, consistent with mineral deposits with high and low levels of manganese, was observed radiating from the calvarial ridge. The results of ICP-MS studies confirm that manganese-treated calvaria take up increasing amounts of manganese with time in culture. Finally, elemental mapping studies with electron probe microanalysis confirmed local variations in the manganese content of bone newly deposited on the calvarial surface. This is the first reported use of manganese-enhanced MRM to study the process whereby calcium is taken up by osteoblasts cells and deposited as bone.  相似文献   

4.
Polyelectrolyte biopolymers such as calcium alginate are becoming increasingly important for the recovery of heavy metals from aqueous solutions. To understand the mechanism of ion transport in these biopolymer systems, the transport of copper ions into calcium alginate gels was investigated using proton nuclear magnetic resonance (NMR) microscopy. Copper ion transport was imaged using an inversion recovery technique which utilizes the paramagnetic effect of copper on water proton relaxation times. Diffusion experiments were performed in a diffusion cell designed to approximate a semi-infinite slab geometry at temperatures between 278 and 313 K using copper reservoir concentrations between 10 and 60 mM. The diffusion coefficient of copper in these gels was calculated from the NMR data to fit a combined diffusion-reaction model involving a diffusion term (D) and a kinetic binding term (k). At 23 °C, the diffusion coefficients in 1, 2, and 3% (w/v) gels were 3.1 · 10−10, 2.0 · 10−10, and 1.4 · 10−10 m2/s, respectively. The activation energy for diffusion in the 2% (w/v) gel was 28 kJ/mol.  相似文献   

5.
In this report, we discuss the application of a methodology for high-contrast, high-resolution magnetic resonance microscopy (MRM) of murine tissue using a 3.0-T imaging system. We employed a threefold strategy that included customized specimen preparation to maximize image contrast, three-dimensional data acquisition to minimize scan time and custom radiofrequency resonator design to maximize signal sensitivity. Images had a resolution of 100×78×78 μm3 with a signal-to-noise ratio per voxel greater than 25:1 and excellent contrast-to-noise ratios over a 30-min acquisition. We quantitatively validated the methods through comparisons of neuroanatomy across two lines of genetically engineered mice. Specifically, we were able to detect volumetric differences of as little as 9% between genetically engineered mouse strains in multiple brain regions that were predictive of underlying impairments in brain development. The overall methodology was straightforward to implement and provides ready access to basic MRM at field strengths that are widely available in both the laboratory and the clinic.  相似文献   

6.
In preclinical research, genetic studies have made considerable progress as a result of the development of transgenic animal models of human diseases. Consequently, there is now a need for higher resolution MRI to provide finer details for studies of small animals (rats, mice) or very small animals (insects). One way to address this issue is to work with high-magnetic-field spectrometers (dedicated to small animal imaging) with strong magnetic field gradients. It is also necessary to develop a complete methodology (transmit/receive coil, pulse sequence, fixing system, air supply, anesthesia capabilities, etc.). In this study, we developed noninvasive protocols, both in vitro and in vivo (from coil construction to image generation), for drosophila MRI at 9.4 T. The 10*10*80-μm resolution makes it possible to visualize whole drosophila (head, thorax, abdomen) and internal organs (ovaries, longitudinal and transverse muscles, bowel, proboscis, antennae and optical lobes). We also provide some results obtained with a Drosophila model of muscle degeneration. This opens the way for new applications of structural genetic modification studies using MRI of drosophila.  相似文献   

7.
The quantum theory of a single-spin measurement using magnetic resonance force microscopy is presented. We use an oscillating cantilever-driven adiabatic reversal technique. The frequency shift of the cantilever vibrations is estimated. We show that the frequency shift causes the formation of a Schrödinger cat state for the cantilever. The interaction between the cantilever and the environment quickly destroys the coherence between the two cantilever trajectories. It is shown that using partial adiabatic reversals one can obtain a significant increase in the frequency shift. We discuss the possibility of sub-magneton spin density detection in molecules using magnetic resonance force microscopy.  相似文献   

8.
We present an optimized uniplanar magnetic resonance gradient design specifically tailored for MR imaging applications in developmental biology and histology. Uniplanar gradient designs sacrifice gradient uniformity for high gradient efficiency and slew rate, and are attractive for surface imaging applications where open access from one side of the sample is required. However, decreasing the size of the uniplanar gradient set presents several unique engineering challenges, particularly for heat dissipation and thermal insulation of the sample from gradient heating. We demonstrate a new three-axis, target-field optimized uniplanar gradient coil design that combines efficient cooling and insulation to significantly reduce sample heating at sample-gradient distances of less than 5 mm. The instrument is designed for microscopy in horizontal bore magnets. Empirical gradient current efficiencies in the prototype coils lie between 3.75 G/cm/A and 4.5 G/cm/A with current and heating-limited maximum gradient strengths between 235 G/cm and 450 G/cm at a 2% duty cycle. The uniplanar gradient prototype is demonstrated with non-linearity corrections for both high-resolution structural imaging of tissue slices and for long time-course imaging of live, developing amphibian embryos in a horizontal bore 7 T magnet.  相似文献   

9.
The methodology for obtaining two- and three-dimensional magnetic resonance images by using azimuthally symmetric dipolar magnetic fields from ferromagnetic spheres is described. We utilize the symmetric property of a geometric sphere in the presence of a large externally applied magnetic field to demonstrate that a complete two- or three-dimensional structured rendering of a sample can be obtained without the motion of the sample relative to the sphere. Sequential positioning of the integrated sample-sphere system in an external magnetic field at various angular orientations provides all the required imaging slices for successful computerized tomographic image reconstruction. The elimination of the requirement to scan the sample relative to the ferromagnetic tip in this imaging protocol is a potentially valuable simplification compared to previous scanning probe magnetic resonance imaging proposals.  相似文献   

10.
Several aspects of magnetic resonance microscopy are examined employing three-dimensional (3D) back-projection reconstruction techniques in combination with either simple Bloch-decay methods or MREV-8 multiple-pulse line narrowing techniques in the presence of static field gradients. Applications to the areas of ceramic processing, catalyst porosity measurements and the characterization of polymeric materials are presented. The focus of the discussion centers on issues of sensitivity and resolution using this approach compared with other methods. Advantages and limitations of 3D microscopy over more commonly employed slice selection protocols are discussed, as well as potential remedies to some of the inherent limitations of the technique.  相似文献   

11.
We introduce the concept of amplifying the transverse magnetic fields produced and/or detected with inductive coils in magnetic resonance settings by using the reversible transverse susceptibility properties of magnetic nanostructures. First, we describe the theoretical formalism of magnetic flux amplification through the coil in the presence of a large perpendicular DC magnetic field (typical of magnetic resonance systems) achieved through the singularity in the reversible transverse susceptibility in anisotropic single domain magnetic nanoparticles. We experimentally demonstrate the concept of transverse magnetic flux amplification in an inductive coil system using oriented nanoparticles with uni-axial magnetic anisotropy. We also propose a composite ferromagnetic/anti-ferromagnetic core/shell nanostructure system with uni-directional magnetic anisotropy that, in principle, provides maximal transverse magnetic flux amplification.  相似文献   

12.
A soy bread of fully acceptable quality and containing 49% soy ingredients (with or without 5% almond powder) has been recently developed in our laboratory.

An investigation on water distribution and mobility, as probed by proton signal intensity and T2 magnetic resonance images, during storage was designed to examine possible relations between water states and hindered staling rate upon soy or soy–almond addition.

Water proton distribution throughout soy-containing loaves was found to be very homogeneous in fresh breads with and without almond, with minimal water migration occurring during prolonged storage. In contrast, traditional wheat bread displayed an inhomogeneous water proton population that tended to change (with higher moisture migration towards the outer perimeter of the slice) during storage. Similar results were found for water mobility throughout the loaves, as depicted in T2 images. On intensity images of all considered bread varieties, the outer perimeter corresponding to the crust exhibited lower signal intensity due to decreased water content. Higher T2 values were found in the crust of soy breads with and without almond, which were attributed to lipids.

The results indicated that the addition of soy to bread improved the homogeneous distribution of water molecules, which may hinder the staling rate of soy-containing breads. However, incorporation of almond had little effect on the water proton distribution or mobility of soy breads.  相似文献   


13.
14.
An electropolished magnetic needle made of Nd(2)Fe(14)B permanent magnet was used for obtaining better spatial resolution than that achieved in our previous work. We observed the magnetic field gradient |G(Z)|=80.0G/microm and the field strength B=1250G at Z approximately 8.8 microm from the top of the needle. The use of this needle for three dimensional magnetic resonance force microscopy at room temperature allowed us to achieve the voxel resolution to be 0.6 microm x 0.6 microm x 0.7 microm in the reconstructed image of DPPH phantom. The acquisition time spent for the whole data collection over 64 x 64 x 16 points, including an iterative signal average by six times per point, was about 10 days.  相似文献   

15.
In a previous nuclear magnetic resonance (NMR) study we observed that the NMR spectra of water in both surfacted and ionic ferrofluids are asymmetric and several orders of magnitude wider than the one of pure water. It has been proposed that this effect is produced by extremely strong magnetic field gradients in the intergrain volume and/or by surface interactions between the carrier liquid molecules and the grains surface. In the case of aqueous ionic ferrofluids the latter possibility should be interpreted as electric interactions between water (polar) molecules and the charges in the grain surface.

In this work we study a series of ionic and surfacted ferrofluids prepared at different magnetic grain concentrations and sizes, and with different surface charge densities. Our experiments clearly show that the sign and the density of the electric charge on the magnetic grains have no influence on NMR spectra. On the other hand, spectral widths increase with the magnetic grain concentration.  相似文献   


16.
《Current Applied Physics》2018,18(11):1174-1181
In nanomagnetism, one of the crucial scientific questions is whether magnetic behaviors are deterministic or stochastic on a nanoscale. Apart from the exciting physical issue, this question is also of paramount highest relevance for using magnetic materials in a wealth of technological applications such as magnetic storage and sensor devices. In the past, the research on the stochasticity of a magnetic process has been mainly done by macroscopic measurements, which only offer ensemble-averaged information. To give more accurate answer for the question and to fully understand related underlying physics, the direct observation of statistical behaviors in magnetic structures and magnetic phenomena utilizing advanced characterization techniques is highly required. One of the ideal tools for such study is a full-field soft X-ray microscope since it enables imaging of magnetic structures on the large field of view within a few seconds. Here we review the stochastic behaviors of various magnetic processes including magnetization reversal process in thin films, magnetic domain wall motions in nanowires, and magnetic vortex formations in nanodisks studied by full-field soft X-ray microscopy. The origin triggering the stochastic nature witnessed in each magnetic process and the way to control the intrinsic nature are also discussed.  相似文献   

17.
We have solved the problem in which a thin metal wafer (probe) with a nanohole interacts with the flat surface of a metastructured film consisting of metal nanoparticles in an external optical radiation field. Nanoparticles are considered as two-level atomic systems. This interaction of the wafer-probe and the flat surface in the external optical radiation field gives rise to optical near-field resonance, the frequency of which differs significantly from the natural frequencies of two-level atoms in the medium and the probe. The fields inside and outside the probe and metastructured film are calculated in the near-field and far-field zones. The maximum resolution, which is achievable in the suggested scheme of near-field optical microscopy, can reach about 10 nm. __________ Translated from Zhurnal Prikladnoi Spektroskopii, Vol. 74, No. 4, pp. 499–506, July–August, 2007.  相似文献   

18.
To evaluate the potential of magnetic resonance imaging (MRI) in detection and quantification of mitral regurgitation, 26 pts. with echocardiographically or angiographically documented mitral regurgitation were examined using a 0.5 Tesla superconducting magnet. In each patient a multislice-multiphase study in a sagittal-coronal double angulated projection (four-chamber view equivalent) was performed to assess left and right ventricular volumes, ejection fraction and regurgitant fraction. Additionally a blood flow sensitive cine-study (fast field echo: FFE) was done to visualize direction and area of regurgitant jet. MRI data were compared with quantitative and qualitative assessment of mitral regurgitation by angiography, 2D echocardiography, Doppler sonography and color flow mapping. Using the FFE mode MRI was able to detect the regurgitant jet as a typical signal loss within the left atrium in all patients. The ratio of regurgitant jet area/left atrium area as determined by MRI showed a correlation with a comparable ratio from color Doppler sonography of R = 0.87 (p < 0.001). There was also good agreement in semiquantitative grading of mitral regurgitation between MRI and angiography (R = 0.77, p < 0.001). The determination of left and right ventricular stroke volume allowed the calculation of the regurgitant fraction, which showed a correlation with invasively determined regurgitation fraction of R = 0.84 (p < 0.001). These data provide additional information that MRI may be useful as a noninvasive technique to detect and quantify mitral regurgitation.  相似文献   

19.
20.
Ion bombardment induced magnetic patterning (IBMP) was used to write in-plane magnetized micro and submicron patterns in exchange biased magnetic bilayers, where the magnetization directions of the adjacent patterns are antiparallel to each other in remanence. These magnetic patterns were investigated by non-contact magnetic force microscopy (MFM). It is shown that the recorded MFM images of the IBMP patterns in two exemplarily chosen standard layer systems (NiFe (4.8 nm)/NiO (68 nm) and Co (4.8 nm)/NiO (68 nm)) can be well described by a model within the point-dipole approximation for the tip magnetization. For 5 and 0.9 μm wide bar patterns the domain wall widths between adjacent magnetically patterned areas were determined to a≈1 μm. The minimum magnetically stable pattern width was estimated to be 0.7 μm in the standard system Co (4.8 nm)/NiO (68 nm).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号