首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Summary The analysis of natural waxes is a complicated process because they occur as complex mixtures. A study using supercritical fluid chromatography with packed columns made it possible to observe the behavior of each family of hydrocarbons, fatty esters, alcohols, acids and triglycerides. The latter were then separated according to their function type and alkyl chain lengths using octadecyl silica as stationary phase. With a polar modifier added to the supercritical fluid, it was possible to analyse certain waxes. Composition anomalies were observed which related to an overabundance of certain compounds which, in excess, are harmful to the quality of waxes intended for use in cosmetics.  相似文献   

3.
Summary A mini extractor of 85 L void volume and a micro extractor of 3–4 L void volume have been coupled directly with a packed column SFC and used under sub- and supercritical conditions. The mini extractor is suitable for holding adsorbates which can be on-line extracted and the extract chromatographed (direct SFE-SFC). The micro extractor can be used for direct sample introduction of liquid and solid materials under SF conditions. Thus any solvent interference with the sample and the chromatographic conditions is excluded. Standard samples of wood tar residue, engine oil, and metal organic compounds have been tested.  相似文献   

4.
Direct analysis of polar solutes by supercritical fluid chromatography (SFC) has been somewhat limited because the mobile phases in common use are all relatively nonpolar. Derivatization is demonstrated as a viable means for facilitating the SFC separation of sugars. Oligo- and polysaccharides containing up to 18 glucose units are completely resolved by capillary SFC.  相似文献   

5.
Capillary supercritical fluid chromatography (SFC) is proving to be a viable and useful separation method for thermally labile and nonvolatile materials. As with other capillary chromatographic techniques, very fast separations can be accomplished by sacrificing total efficiency and optimizing the conditions for rapid analysis. This is achieved using short, small-bore capillary columns, increased mobile phase linear velocities and very fast pressure programming rates. These principles are demonstrated for the rapid separation of selected component systems.  相似文献   

6.
A new analytical technique combining on-line supercritical fluid chromatography with capillary gas chromatography has been developed. The supercritical fluid sample effluent is decompressed through a restrictor directly into a conventional capillary gas chromatographic injection port. This technique allows for not only direct (100%) sample transfer from the supercritical fluid chromatograph to the gas chromatograph but also for selective or multi-step heartcutting of various sample peaks as they elute from the supercritical fluid chromatograph. Heartcut times are determined by monitoring the responses from the flame ionization or ultraviolet absorbance detectors on the supercritical fluid chromatograph. This report describes the operational setup and provides the results of heartcut reproducibility experiments using normal hydrocarbon and aromatic test mixtures. Results from studies where operational parameters were varied, such as GC injector temperature, will also be provided. The potential usefulness of this new technique for selective heartcutting will also be demonstrated using complex hydrocarbon streams.  相似文献   

7.
Summary In order to prevent plugging during deactivation of small diameter (50 m i.d.) capillary columns for gas and supercritical fluid chromatography, various high temperature deactivation methods were employed. Pure hexamethyldisilazane and hexamethyldisiloxane (a substitute for D4) were dynamically coated on the column, while a film (0.05 m) of OV-101 was statically coated, before high temperature (450°C) treatment. Excellent deactivated columns were obtained, and no significant difference in column activity was observed using any of these three methods.Dedicated to Professor S. R. Lipsky on the occasion of his 60th birthday.  相似文献   

8.
Capillary supercritical fluid chromatography was performed using solvent-vented injection in conjunction with a thermionic ionization detector. Mixtures of organo-nitrogen and phosphorus containing agrochemicals were chromatographed and detection of low picogram quantities was observed.  相似文献   

9.
A new method to accurately deliver small amounts (0.5 to 20 mol%) of modifier into CO2 was used to study the effects of three different modifiers (methanol, water, and formic acid) in packed capillary column SFC. The method allows the use of different modifiers, with minimal instrument modification. The effects of the different modifiers at different concentrations on retention and peak shape are shown by analyzing a polarity test mixture and a sample of free fatty acids.  相似文献   

10.
11.
An analysis of the precision obtained using commercially available microvalve injectors is reported for three modes of injection: conventional split; timed-split; and direct. Results from this study show that good precision (< 3% RSD for external standard and < 1% RSD for internal standard methods) can be obtained with capillary supercritical fluid chromatography (SFC). However, particular attention must be paid to the type of valve used, the orientation of the column relative to the valve, the mode of interfacing or connecting the column to the valve, and the type of pressure or density programming used for the analysis as all of these factors will affect the reproducibility.  相似文献   

12.
N. Wu  R. Yee  M. L. Lee 《Chromatographia》2000,53(3-4):197-200
Summary Fast separations of perfluorinated polyethers and polymethylsiloxanes that are composed of 50–80 oligomers were demonstrated in packed capillary column supercritical fluid chromatography (SFC) using a carbon dioxide mobile phase. Separations were accomplished within 10 min using a 13 cm×250 μm i.d. column packed with 2 μm porous octadecyl bonded silica (ODS) particles. Effects of particle diameter of the packing material and pressure programming on separation were investigated, and packed column SFC was compared with open tubular column SFC. Results show that as the particle diameter was decreased from 5 to 3 to 2 μm and the column length was reduced from 85 to 43 to 13 cm, the separation time could be reduced from 70 to 20 to 10 min while still maintaining similar separation (resolution). Short columns packed with small porous particles are very suitable for fast SFC separations of polymers.  相似文献   

13.
A sample introduction system for capillary supercritical fluid chromatography, which allows the dissolution of the sample in the supercritical mobile phase before being introduced into the column, was constructed and evaluated. Supercritical n-pentane was shown to solvate high-molecular-weight polycyclic aromatic compounds that could not be solvated using typical liquid solvents. In addition, split injection of a supercritical fluid solution was found to be more reproducible than split injections of a liquid solution. The potential of such an injection system was demonstrated, although further developments are needed in order to make the technique of practically utility.  相似文献   

14.
Summary The separation of polar thermally labile solutes is one of the potentially most rewarding fields of SFC application. A presupposition for such applications is, however, mobile phases having relatively high solvent strengths. A promising approach to achieve this is the use of mobile phases consisting of carbon dioxide with a polar additive. In this work, the chromatographic effects of different concentrations of an additive, isopropanol, in carbon dioxide have been studied on capillary and packed columns. A series of antibiotics was used as test substances. Best results were obtained with carbon dioxide/8% isopropanol as mobile phase on a capillary column coated with a cyanopropyl-substituted polysiloxane stationary phase.  相似文献   

15.
Tocochromanols consisting of tocopherols and tocotrienols, is collectively known as vitamin E. Similarity in their structures, physical and chemical properties rendered the tocochromanols to be subject of chromatography interest. Supercritical fluid chromatography is a highly efficient tool for the separation and analysis of tocochromanols. Separation and analysis of tocochromanols using supercritical fluid chromatography had been carried out in the past using capillary or packed columns. Each of these techniques offer their own advantages and drawbacks. Besides being used for analysis, packed column supercritical fluid chromatography found applications as a purification and content enrichment tool. Emergence of new equipment and stationary phase technologies in recent years also helped in making supercritical fluid chromatography a highly efficient tool for the separation and analysis of tocochromanols. This paper gives an insight into the use of capillary and packed columns in supercritical fluid chromatography for the separation and/or analysis of tocochromanols. The types of stationary phase used, as well as chromatographic conditions are also discussed.  相似文献   

16.
Supercritical fluid chromatography (SFC) sometimes exhibits GC-like behavior and sometimes LC-like behavior, depending on conditions. However, it is not always clear whether one of these types of behavior, or a combination, operates for a particular set of conditions for every solute in a mixture. For example, some components may be partitioned mostly by their vapor pressures, while others, in the same mixture, are partitioned predominantly by solvent-like properties of the mobile phase. Plots of retetion (as log of the capacity factor) vs. reciprocal temperature at constant pressure reveal a clear change in the character of the separation of well-behaved solutes. A thermodynamic explanation of the observed behavior is given, based on the assumption that partitioning is controlled by the heats of solution of solute in the mobile and stationary phases. A model of SFC retention as it deviates from pure-GC behavior on the same column is presented.  相似文献   

17.
A rapid and simple RP-TLC method for simultaneous quantification of pharmacologically important sesquiterpene artemisinin (AM) together with its precursors arteannuin-B (AB) and artemisinic acid (AA) in the inflorescence part of Artemisia annua plant has been developed. The RP-TLC of sesquiterpenes was performed on RP-18 F254 S thin-layer chromatographic plates by developing in mobile phase, containing 0.2% TFA in water/ACN (35:65, v/v). The densitometric determination of AM, AB and AA was carried out after derivatization with anisaldehyde reagent at 426 nm in absorption-reflectance mode.  相似文献   

18.
Fatty acid methyl esters from various fats and oils were separated by comprehensive two-dimensional supercritical fluid chromatography with conventional packed columns and FID detection. The first dimension was a silica gel column and the second dimension was an ODS column. This combination was largely orthogonal for the separation of fatty acid methyl esters. The first dimension separations were primarily based on the number of double bonds while the second dimension separations were based on the chain length. The highly-ordered chromatograms and improved resolution allowed the easy detection and identification of minor components. Although the first dimension separations were performed under isobaric conditions where the peak width increased in proportion to the retention, the programming of the sampling duration allowed us to maintain the optimum re-injection frequency (3–4 times) per peak into the second dimension and so to minimize the total analysis time without deteriorating the resolution.  相似文献   

19.
In cases where high efficiency is required to resolve complex mixtures of either thermally labile or nonvolatile organic compounds, capillary supercritical fluid chromatography may be the most desirable analytical method. While great strides in this new technology have been made over the last few years, several problem areas are requiring increased attention. These include sample introduction systems, pressure reduction at the end of the column, column stability in various supercritical mobile phases, and migration of polar solute molecules. This paper describes the state-of-the-art in capillary SFC with emphasis on the progress made and future needs in the solutions to these specific problems.  相似文献   

20.
Summary An interface described in the literature was modified to accommodate small sample quantities. The simple and inexpensive method can be used to obtain rapid qualitative sample information of complex matrices by extraction in sub- or supercritical conditions (SFE) with a concurrent separation by capillary supercritical fluid chromatography (CSFC). Compared to traditional solvent extraction methods the potential for analyte degradation and contamination is minimized resulting in reduced sample amount necessary for extraction and separation, and also in faster extractions. Complex matrices of a plastic material, a natural product and a soil spiked with a substituted hydrocarbon test mixture were analyzed to show the usefulness of the interface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号