首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive rapid resolution liquid chromatography-tandem mass spectrometry (RRLC-MS/MS) method, combined with solid-phase extraction, ultrasonic extraction and silica gel cartridge cleanup, was developed for 28 steroids including 4 estrogens (estrone (E1), 17β-estradiol (E2), 17α-ethynyl estradiol (EE2), diethylstilbestrol (DES)), 14 androgens (androsta-1,4-diene-3,17-dione (ADD), 17α-trenbolone, 17β-trenbolone, 4-androstene-3,17-dione, 19-nortestoserone, 17β-boldenone, 17α-boldenone, testosterone (T), epi-androsterone (EADR), methyltestosterone (MT), 4-hydroxy-androst-4-ene-17-dione (4-OHA), 5α-dihydrotestosterone (5α-DHT), androsterone (ADR), stanozolol (S)), 5 progestagens (progesterone (P), ethynyl testosterone (ET), 19-norethindrone, norgestrel, medroxyprogesterone (MP)), and 5 glucocorticoids (cortisol, cortisone, prednisone, prednisolone, dexamethasone) in surface water, wastewater and sludge samples. The recoveries of surface water, influents, effluents and sludge samples were 90.6-119.0% (except 5α-DHT was 143%), 44.0-200%, 60.7-123% and 62.6-138%, respectively. The method detection limits for the 28 analytes in surface water, influents, effluents and freeze-dried sludge samples were 0.01-0.24 ng/L, 0.02-1.44 ng/L, 0.01-0.49 ng/L and 0.08-2.06 ng/g, respectively. This method was applied in the determination of the residual steroidal hormones in two surface water of Danshui River, 12 wastewater and 8 sludge samples from two wastewater treatment plants (Meihu and Huiyang WWTPs) in Guangdong (China). Ten analytes were detected in surface water samples with concentrations ranging between 0.4 ng/L (17β-boldenone) and 55.3 ng/L (5α-DHT); twenty analytes in the wastewater samples with concentrations ranging between 0.3 ng/L (P) and 621 ng/L (5α-DHT); and 12 analytes in the sludge samples with concentrations ranging between 1.6 ng/g (E1) and 372 ng/g (EADR).  相似文献   

2.
In this study, reduction of estrogenic activity in three different types of effluents from sewage, industrial and livestock wastewater treatment plants by gamma-irradiation was investigated using the yeast two-hybrid assay. After gamma-ray treatment at a dose of 10 kGy, estrogenic activities of sewage, industrial and livestock effluents decreased from 4.4 to 3.0, 1.5 to 1.0 and 16 to 9.9 ng-EEQ L?1, respectively. The substantial reduction of estrogenic activity in livestock effluent was attributable to the degradation of 17β-estradiol (E2), estrone (E1) and 17α-ethynylestradiol (EE2). Although bisphenol A (BPA) was found at the highest concentration in all effluents, its contribution to the estrogenic activity was not significant due to its low relative estrogenic potency. Meanwhile, the calculated estrogenic activity based on concentrations of E2, E1, EE2 and BPA in the effluents significantly differed from the measured ones. Overestimation may have resulted by dissolved organic matters in effluents inhibiting the estrogenic activity of E2, E1, EE2 and BPA, whereas underestimation was likely due to estrogenic by-products generated by gamma-irradiation.  相似文献   

3.
黄成  姜理英  陈建孟  陈效 《色谱》2008,26(5):618-621
采用固相萃取-衍生化气相色谱/质谱法(GC/MS)测定某制药厂污水中的雌酮(E1)、雌二醇(E2)、雌三醇(E3)和乙炔基雌二醇(EE2)4种雌激素化合物。样品经固相萃取柱萃取富集及双(三甲基硅烷基)三氟乙酰胺(1%三甲基氯硅烷)(BSTFA(1%TMCS))衍生化后进行GC/MS分析。该法对4种目标物的检出限为1.8~4.7 ng/L,相对标准偏差为2.3%~9.1%(n=8)。目标化合物的加标回收率为(94.0±2.9)%~(101±3.8)%,说明该方法能较好地应用于污水中雌激素化合物的定量检测。通过对某制药厂污水中的雌激素进行定量分析,发现污水中乙炔基雌二醇和雌酮质量浓度分别达396.6 和39.9 ng/L;经过传统的厌氧兼氧好氧生物处理后,污水中的环境雌激素的去除率仅为35%~40%,说明传统的污水处理工艺对去除污水中雌激素效果并不明显,需要改进。  相似文献   

4.
Fish can be exposed to a complex mixture of chemical contaminants arising from the exposure to wastewater treatment works (WwTWs) effluents. Some of these contaminants are estrogenic and have been associated with feminisation of male fish and the presence of populations containing intersex individuals. However the detection of trace levels (ng/L) of estrogenic chemicals surface waters can be difficult and does not give information on the exposure of aquatic organisms to these contaminants. In this study we assessed whether the analysis of estrogenic substances that bioconcentrate in fish bile can be used to detect the exposure of fish to feminising contaminants in receiving waters and effluents, and thus facilitate their monitoring of these substances in aquatic environments. Estrogenic metabolites in bile were deconjugated using enzymatic hydrolysis and partially purified by solid phase extraction. Steroidal and xenoestrogens were derivatized to their trimethylsilyl ethers and quantified by gas–liquid chromatography–mass spectrometry (GC–MS/MS) using multiple reaction monitoring. The method was validated using spiked bile samples from immature female rainbow trout (Oncorhynchus mykiss) as well as bile from sexually mature roach (Rutilus rutilus) that had been exposed to either tap water or an undiluted estrogenic effluent for 10 days or captured from a river site downstream of a WwTWs effluent discharge. The mean recovery of target analytes from spiked bile was between 86 and 99% and the limit of detection was between 0.1 and 0.7 ng/mL bile for bisphenol A (BPA), 17β-estradiol (E2), estrone (E1) and 17α-ethinylestradiol (EE2), and 11, 60 and 327 ng/mL bile for branched nonyl chain isomeric mixtures of 4-nonylphenolethoxylate (NP1EO), 4-nonylphenol (NP) and 4-nonylphenoldiethoxylate (NP2EO), respectively. All target analytes were detected in bile from roach exposed directly to a WwTWs effluent, with concentrations between 6–13 μg/mL bile for NP, 18–21 μg/mL for NP1EO, 75–135 μg/mL for NP2EO, 0.7–2.5 μg/mL for BPA, E2 and E1 and 17–29 ng/mL for EE2. With the exception of NP2EO, all analytes were detected in at least 2 out of the 5 fish sampled from the River Thames. BPA and NP1EO were detected in all three reference fish held in tap water indicating possible contamination from laboratory plastics. The work shows that analysis of 20–100 μL quantities of bile could be a useful approach in detecting exposure to mixtures of estrogenic contaminants taken up by fish from WwTW effluents and has the potential for monitoring the efficacy of remediation strategies that may be adopted for reduction of these endocrine disrupting chemicals in the aquatic environment.  相似文献   

5.
A method for the analysis of clotrimazole was developed with dispersive liquid–liquid microextraction for sample pre‐concentration and HPLC–MS/MS for analysis. A linear ion trap was used for the confirmation of clotrimazole identity in the samples. The developed method enables the analysis of clotrimazole in river water and sewage effluent from wastewater treatment plants with a LOQ of 0.7 ng/L. Environmental monitoring of clotrimazole was undertaken. Samples from river water and sewage effluents were analysed over a one‐year period. Clotrimazole was found in every tested sample with concentration range from 1 to 31 ng/L. The amount of clotrimazole in tested samples was highly dependent on sampling season. The highest results were obtained in summer and autumn.  相似文献   

6.
An analytical method for the determination of the major endogenous and exogenous estrogenic steriods in effluent water samples of sewage treatment plants (STPs) with a LOQ down to 1 ng/L and below has been developed. The exogenous estrogen 17alpha-ethynylestradiol, frequently used as estrogenic component in oral contraceptives, and the endogenous estrogen 17beta-estradiol show the highest estrogenic potential, therefore they were part of our target compounds. In addition, the content of the synthetic gestagen levonorgestrel, also often administered in oral contraceptives, was determined. A solid-phase extraction system for high volume sampling of water up to 25 L was implemented. Two types of adsorbent, Amberlite XAD 2 and a mixture of LiChrolut EN/Bondesil C-18, respectively, were tested for their extraction efficiency of these polar analytes. Recovery rates with LiChrolut EN/Bondesil C-18 ranged up to 94%, whereas sampling on XAD 2 led only to poor recoveries below 40%. After a liquid chromatographic clean-up step on silicagel the steroids were converted into their trimethylsilyl-ethers by the reaction with MSTFA/TMSI (N-methyl-N-trimethylsilyl-2,2,2-trifluoroacetamide, trimethylsilyliodide) and were then determined by HRGC/MS in the selected ion mode. A limit of quantification over the whole procedure of at least 1 ng/L was reached for all analytes. In several effluent samples the input of estrogens by the STP of the cities Ulm and New Ulm into the river Danube was characterised. The concentrations commonly found ranged from 1 ng/L up to 13 ng/L, depending on the respective steroid.  相似文献   

7.
An analytical method for the determination of the major endogenous and exogenous estrogenic steriods in effluent water samples of sewage treatment plants (STPs) with a LOQ down to 1 ng/L and below has been developed. The exogenous estrogen 17α-ethynylestradiol, frequently used as estrogenic component in oral contraceptives, and the endogenous estrogen 17β-estradiol show the highest estrogenic potential, therefore they were part of our target compounds. In addition, the content of the synthetic gestagen levonorgestrel, also often administered in oral contraceptives, was determined. A solid-phase extraction system for high volume sampling of water up to 25 L was implemented. Two types of adsorbent, Amberlite XAD 2 and a mixture of LiChrolut EN/Bondesil C-18, respectively, were tested for their extraction efficiency of these polar analytes. Recovery rates with LiChrolut EN/¶Bondesil C-18 ranged up to 94 %, whereas sampling on XAD 2 led only to poor recoveries below 40 %. After a liquid chromatographic clean-up step on silicagel the steroids were converted into their trimethylsilyl-ethers by the reaction with MSTFA/TMSI (N-methyl-N-trimethylsilyl-2,2,2-trifluoroacetamide, trimethylsilyliodide) and were then determined by HRGC/MS in the selected ion mode. A limit of quantification over the whole procedure of at least 1 ng/L was reached for all analytes. In several effluent samples the input of estrogens by the STP of the cities Ulm and New Ulm into the river Danube was characterised. The concentrations commonly found ranged from 1 ng/L up to 13 ng/L, depending on the respective steroid.  相似文献   

8.
A multimethod based on liquid-liquid extraction and solid-liquid extraction for the analysis of persistent organic pollutants in water and sludge from sewage treatment plants has been established. Traces of 22 organic compounds used in industry and personal care products (PCPs) were analyzed by GC/MS. The LODs for the analytes were less than 2.3 ng/L for wastewater and 31 microg/kg (dry weight matter) for sewage sludge. Satisfactory recoveries (70-130%) were achieved. The validated method permits the analysis of water and sludge samples at various stages of the treatment from different sewage treatment plants. Thus, the distribution between water and sludge as well as the dissipation of the compounds analyzed were balanced. By this means, the efficiency of different wastewater treatment plants (WWTPs) can be evaluated and measures can be taken to optimize the treatment process at different stages.  相似文献   

9.
A chiral liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) method was developed and validated for measuring individual enantiomers of three beta-blocker drugs (atenolol, metoprolol, and propranolol) in wastewater treatment plant (WWTP) influents and effluents. Mean recoveries of the pharmaceuticals ranged from 67 to 106%, and the limits of detection of the analytes were 2-17 ng/L in wastewater effluents. The method was demonstrated by measuring, for the first time, the stereoisomer composition of target analytes in raw and treated wastewaters of two Canadian WWTPs. In these trials, racemic amounts of the three drugs were observed in influent of one wastewater treatment plant, but nonracemic amounts were observed in another. Effluents of the two plants contained nonracemic amounts of the drugs. These results indicate that biologically-mediated stereoselective processes that differ among WWTPs had occurred to eliminate individual enantiomers of the target analytes.  相似文献   

10.
An analytical method with two extraction steps has been developed and validated for the simultaneous determination of 30 pharmaceuticals belonging to various therapeutic categories in urban wastewater. The aim was to boost the little available information on drugs' fates in sewage treatment plants (STPs) and in the receiving surface water. Aqueous samples were divided into two aliquots, each extracted by a different solid-phase extraction (SPE) method and analysed by reversed-phase liquid chromatography tandem mass spectrometry (HPLC-MS-MS). Recoveries of the pharmaceuticals were mostly greater than 70% and the overall variability of the method was below 8%. The instrumental quantification limit (IQL) varied between 30 and 400 pg injected, and the limits of quantification (LOQ) were in the low ng/L range. Nineteen pharmaceuticals were detected in concentrations between 0.5 and 2000 ng/L in effluents collected from several STPs in Italy. Atenolol, ciprofloxacin, furosemide, hydrochlorothiazide, ofloxacin, ranitidine and sulphamethoxazole were the most abundant compounds. The present analytical method was useful to check for pharmaceuticals in various Italian STPs and to identify the most abundant compounds.  相似文献   

11.
Large volume injection-programmable temperature vaporization-gas chromatography-mass spectrometry (LVI-PTV-GC-MS) was optimized for the determination of estrone (E1), 17β-estradiol (E2), 17α-ethynyl estradiol (EE2), mestranol (MeEE2) and estriol (E3) for their determination in environmental samples (estuarine water, wastewater, fish bile and fish homogenate) after derivatization with 25 μL (BSTFA+1% TMCS) and 125 μL of pyridine. Experimental designs such as Plackett-Burman (PBD) and central composite designs (CCDs) were used to optimize the LVI-PTV variables (cryo-focusing temperature, vent time, vent flow, vent pressure, injection volume, purge flow to split vent, splitless time and injection speed). Optimized conditions were as follows: 45 μL of n-hexane extract are injected at 60°C and 6 μL/s with a vent flow and a vent pressure of 50 mL/min and 7.7 psi, respectively, during 5 min; then the split valve is closed for 1.5 min and afterwards the injector is cleaned at 100 mL/min before the next injection. The method was applied to the determination of estrogenic compounds in environmental samples such as estuarine water, wastewater, and fish homogenate and bile. Limits of detection (0.04-0.15 ng/L for water samples, 0.04-0.67 ng/g for fish bile and 0.1-7.5 ng for fish homogenate) obtained were approx. ten times lower than those obtained by means of a common split/splitless inlet.  相似文献   

12.
Even in trace amounts, estrogens such as 17beta-estradiol (E2), estrone (E1), estriol (E3), and 17alpha-ethinyl estradiol (EE2) may have adverse effects on humans and the aquatic ecosystem. Therefore, it is essential to be able to measure trace amounts of steroid estrogens in water. To date, most instruments are not sensitive enough to detect these chemicals in small samples of water. Sensitivity, however, may be improved by using appropriate derivatization reagents to modify the structures of these estrogens so that their ionization efficiency is increased, making them more detectable by liquid chromatography/mass spectrometry (LC/MS). This study uses dansyl chloride, 2-fluoro-1-methylpyridinium p-toluenesulfonate (FMPTS), and pentafluorobenzyl bromide (PFBBr) as derivatization reagents to react with the phenolic estrogens to make them more detectable in water. We also test how environmental matrices (wastewater effluent, river water, and drinking water) influence the detectability of these estrogens. Both qualitative and semi-quantitative comparisons of these derivatization methods were made. We found that dansyl chloride derivatives created signal intensities one or two orders of magnitude greater than those normally found in underivatized estrogen standards. The signals derived by FMPTS were analyte-dependent, and the products derived from E1, E2, and EE2 produced 2.19 to 12.1 times the signal intensity of underivatized E1, E2, and EE2. The product derived from E3 produced weaker signals than that produced by underivatized E3. The PFBBr derivatives produced signals that were as much as 5.8 times those found in the underivatized estrogens. When these derivatization methods were applied to river water, drinking water and effluents from a sewage treatment plant (STP), the different matrices were found to significantly suppress the signals if we used electrospray ionization, though this influence became less significant if we used atmospheric pressure chemical ionization. This study suggests that PFBBr derivatization can best be used for the detection of these estrogens in complex environmental matrices such as river water and STP effluents and that the dansyl chloride derivatization is best used for clean samples such as drinking water.  相似文献   

13.
A simultaneous determination method using solid‐phase extraction and liquid chromatography with tandem mass spectrometry was developed to detect and quantify the presence of seven multiclass veterinary antibiotics (13 compounds in total) in surface water samples, which included the effluents of livestock wastewater and sewage treatment plants, as well as the reservoir drainage areas from dense animal farms. The pH of all water samples was adjusted to 2 or 6 before solid‐phase extraction using Oasis HLB cartridges. The developed method was fully validated in terms of linearity, method detection limit, method quantitation limit, accuracy, and precision. The linearity of all tested drugs was good, with R2 determination coefficients ≥ 0.9931. The method detection limits and method quantitation limits were 0.1–74.3 and 0.5–236.6 ng/L, respectively. Accuracy and precision values were 71–120 and 1–17%, respectively. The determination method was successfully applied for monitoring water samples obtained from the Yeongsan River in 2015. The most frequently detected antibiotics were lincomycin (96%), sulfamethazine (90%), sulfamethoxazole (88%), and sulfathiazole (50%); the maximum concentrations of which were 398.9, 1151.3, 533.1, and 307.4 ng/L, respectively. Overall, the greatest numbers and concentrations of detected antibiotics were found in samples from the effluents of livestock wastewater, sewage treatment plants, and reservoir drainage areas. Diverse veterinary antibiotics were present, and their presence was dependent upon the commercial sales and environmental properties of the analytes, the geographical positions of the sampling points, and the origin of the water.  相似文献   

14.
A solid‐phase extraction and liquid chromatography‐tandem mass spectrometry (SPE/LC‐MS‐MS) method was developed and validated for the simultaneous determination of nicotine, five drugs of abuse (morphine, cocaine, codeine, methadone, and 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine) and four metabolites (dihydrocodeine, 6‐acetylmorphine, 11‐nor‐carboxy‐Δ9‐tetrahydrocannabinol, and benzoylecgonine) in water samples. A Fused‐Core? particle column was used as an alternative to sub‐2‐μm particles in chromatographic separations to work with low backpressures and high efficiencies in short analysis times. Drugs were extracted from waste and surface water with SPE using Oasis MCX cartridges. Electrospray (ESI) in positive and negative mode and tandem MS selected reaction monitoring mode were used for identification and quantification. Calibration by linear regression analysis with deuterated internal standards was used to compensate the matrix effects. Limits of detection were found as low as 0.5–1 ng/L (surface water) and 1–50 ng/L (wastewater). The method was applied to the analysis of different kinds of samples. Wastewater from a sewage treatment plant was collected from three sampling points (after primary, secondary, and tertiary treatments) for a week. The analysis of the samples revealed a significant presence of these drugs in samples from primary treatments, where maximum concentrations of nicotine (1105 ng/L) and benzoylecgonine (3336 ng/L) were found. Most of the compounds showed values between 相似文献   

15.
A simple, fast, and sensitive method is proposed for the analysis of 32 priority substances (PS) from EU Water Framework Directive (WFD) and the first Watch List in effluents of wastewater treatment plants (EWW), surface waters (SW) and drinking waters (DW). Dispersive liquid-liquid microextraction (DLLME) and gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) is used. For DLLME, a mixture of 1,1,2-trichloroethane as extraction solvent (75 µL) and acetonitrile as disperser solvent (3.2 mL) is proposed. The method was validated in EWW, SW and DW, showing satisfactory accuracy values ranging from 90% to 104%, good precision (relative standard deviation, RSD%, lower than 13%) and uncertainty values between 7% and 34%. Regarding sensitivity, method limits of quantification (MLOQs) of 4.8, 5.2 and 8.8 ng L?1 for DW, SW and EWW, respectively, were obtained. The developed method was applied to analyze PS in water from effluents of waste water treatment plants (WWTPs), surface water of the Llobregat River and its main tributaries (Catalonia, NE Spain) and drinking water from a Drinking Water Treatment Plant (DWTP). Moreover, the efficiency of treatment plants (DWTP, WWTP) on the elimination of PS was evaluated. Only 3 PS (lindane, terbutryn and dicofol) were detected, being terbutryn the compound found at the highest levels (up to 493 ng L?1 in EWW samples). Regarding environmental quality standard (WFD) for terbutryn in surface waters, only one sample, the Rubí stream (431 ng L?1), showed levels of terbutryn higher than maximum allowable concentration (340 ng L?1).  相似文献   

16.
A method for the quantitative determination of seven major antidepressants in surface waters and sewage treatment plant effluents by CE using ESI-MS is presented. Calibration curves for the selected analytes were prepared in Milli-Q purified water and Danube river water extract covering a concentration range of at least one order of magnitude. LODs achieved were between 6 and 13 microg/L for Trazodone and 39 and 53 microg/L for Sertraline in the Milli-Q purified water and Danube river water matrix, respectively. For sample preparation eight different SPE materials were investigated. Best results were obtained for a resin based on hydrophilic divinylbenzene (recoveries from Milli-Q purified water 93-96%; from Danube river water 85-99%). Finally, a series of eight sewage treatment plant effluents were investigated with respect to their content in the selected antidepressants. Six of these samples were tested positive for antidepressants, in particular Venlafaxine, Citalopram and Trazodone in concentrations between 36 and 322 ng/L.  相似文献   

17.
The challenge of analyzing beta-blocker drugs in sludge and wastewater   总被引:1,自引:0,他引:1  
In this study, different approaches were used to assess and overcome the severe effects of interference from the sample matrix from different types of sludges and wastewater on the analysis of nine beta-blockers and the beta sympathomimetic clenbuterol. The partitioning of the target compounds into sludge was investigated in wastewater treatment plants (WWTPs) in both Canada and Germany to evaluate whether this is an important mechanism for removal from sewage. Due to ion suppression in the electro spray interface, absolute recoveries were for certain compounds even lower than 20%. By using surrogate standards, acceptable relative recoveries of >75% were achieved for WWTP influents and effluents and for sludges. These matrix effects underline the need to use appropriate surrogate standards to aid in analyte quantitation. Using the developed methods, beta-blockers were detected at concentrations up to 2 μg/L in WWTP effluents, with metoprolol, sotalol, and atenolol present as the dominant compounds. Removal rates within WWTPs were highly inconsistent and ranged from 1-69%. Propranolol showed the greatest degree of partitioning into sludge with solid/water partition coefficients of one order of magnitude higher than those for all other compounds. However, even for propranolol, sorption did not contribute significantly to the overall elimination in WWTPs. It is likely that the removal of beta-blockers during waste water treatment can be attributed primarily to microbial biodegradation.  相似文献   

18.
An improved LC-electrospray ionization MS method was established for four estrogens (17beta-estradiol (E2), estriol (E3), estrone (E1), and ethynyl estradiol (EE)) in environmental water. Almost complete separation of all estrogens was achieved on a phenyl column with methanol/water as the mobile phase. Quantification was achieved in the negative ionization mode using selected ion monitoring. The instrumental detection limits were 20-30 ng/l for the four analytes. In Milli-Q spiked water, the recoveries of the four estrogens were 72-81%, which was similar to those found for river water spiked with the corresponding deuterated estrogens. The detection limits for the four estrogens in river water were 0.1-0.2 ng/l. The method was used to detect residual estrogens in the Tonghui River, which receives water from a municipal sewage treatment plant in Beijing; E1 (1.1 ng/l) and E2 (0.2 ng/l) were detected.  相似文献   

19.
A rapid microwave-accelerated derivatization process for the GC-MS analysis of steroid estrogens, estrone (E1), 17beta-estradiol (E2), estriol (E3), 17alpha-ethynylestradiol (EE2) and mestranol (MeEE2), was developed. Under microwave irradiation, the five estrogenic hormones studied were simultaneously derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA)+trimethylchlorosilane (TMCS) in pyridine solution. Effects of irradiation time (15-120 s) and power level (240-800 W) on the yield of the derivatization were investigated. The derivatization under the irradiation of 800 W microwave for 60s produced comparable results when compared with the conventional heating process in a sand bath for 30 min at 80 degrees C in terms of derivatization yield, linearity and precision for all steroid hormones tested. The calibration curves are linear between 3.00 and 3.00 x 10(2) microg mL(-1). The square of the regression coefficients (R(2)) range from 0.979 to 1.000. The applicability of the method was evaluated on spiked river and distilled water samples at two concentrations, 25.0 and 2.00 x 10(2) ng mL(-1). The recoveries obtained by using microwave heating (60s, 800 W) were similar to those by conventional heating. When combined solid-phase extraction (SPE) with the application of the microwave-accelerated derivatization proposed here, the detection limits of 0.02-0.1 ng L(-1) for the steroid hormones have been achieved. The results demonstrated that microwave-accelerated derivatization is an efficient and suitable sample preparation method for the GC-MS analysis of estrogenic steroids.  相似文献   

20.
An ultra-high-pressure liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method has been developed for the simultaneous quantification and confirmation of 11 basic/acidic illicit drugs and relevant metabolites in surface and urban wastewater at ng/L levels. The sample pre-treatment consisted of a solid-phase extraction using Oasis MCX cartridges. Analyte deuterated compounds were used as surrogate internal standards (except for norbenzoylecgonine and norcocaine) to compensate for possible errors resulting from matrix effects and those associated to the sample preparation procedure. After SPE enrichment, the selected drugs were separated within 6 min under UHPLC optimized conditions. To efficiently combine UHPLC with MS/MS, a fast-acquisition triple quadrupole mass analyzer (TQD from Waters) in positive-ion mode (ESI+) was used. The excellent selectivity and sensitivity of the TQD analyzer in selected reaction monitoring mode allowed quantification and reliable identification at the LOQ levels. Satisfactory recoveries (70–120%) and precision (RSD < 20%) were obtained for most compounds in different types of water samples, spiked at two concentration levels [limit of quantification (LOQ) and 10LOQ]. Thus, surface water was spiked at 30 ng/L and 300 ng/L (amphetamine and amphetamine-like stimulants), 10 ng/L and 100 ng/L (cocaine and its metabolites), 300 ng/L and 3000 ng/L (tetrahydrocannabinol-COOH). Recovery experiments in effluent and influent wastewater were performed at spiking levels of three and fifteen times higher than the levels spiked in surface water, respectively. The validated method was applied to urban wastewater samples (influent and effluent). The acquisition of three selected reaction monitoring transitions per analyte allowed positive findings to be confirmed by accomplishment of ion ratios between the quantification transition and two additional specific confirmation transitions. In general, drug consumption increased in the weekends and during an important musical event. The highest concentration levels were 27.5 μg/L and 10.5 μg/L, which corresponded to 3,4-methylenedioxymethamphetamine (MDMA, or ecstasy) and to benzoylecgonine (a cocaine metabolite), respectively. The wastewater treatment plants showed good removal efficiency (>99%) for low levels of illicit drugs in water, but some difficulties were observed when high drug levels were present in wastewaters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号