共查询到20条相似文献,搜索用时 18 毫秒
1.
亲水作用色谱-串联质谱法同时测定液态奶中三聚氰酸和三聚氰胺 总被引:1,自引:0,他引:1
建立了亲水作用色谱-串联质谱同时测定液态奶中三聚氰酸和三聚氰胺的方法。液态奶样品经体积分数2.5%甲酸溶液提取、离心后乙腈稀释,亲水作用色谱柱分离,电喷雾串联四极杆质谱检测器检测,分别在负、正离子模式下测定三聚氰酸和三聚氰胺。三聚氰酸和三聚氰胺分别在0.5~100μg/L、0.1~50μg/L范围内线性关系良好。在0.25~15mg/kg、0.1~7.5mg/kg添加水平范围内,三聚氰酸平均回收率为84.5%~98.0%(RSD为2.1%~6.1%),三聚氰胺平均回收率为85.5%~88.9%(RSD为3.2~5.8%)。三聚氰酸、三聚氰胺定量限分别为0.25mg/kg、0.1mg/kg。 相似文献
2.
Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry 下载免费PDF全文
Kazuhiro Sonomura Shinobu Kudoh Taka‐Aki Sato Fumihiko Matsuda 《Journal of separation science》2015,38(12):2033-2037
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage. 相似文献
3.
Ji HY Jeong DW Kim YH Kim HH Yoon YS Lee KC Lee HS 《Rapid communications in mass spectrometry : RCM》2006,20(14):2127-2132
A rapid, sensitive and selective method for the determination of gabapentin in human plasma was developed using hydrophilic interaction liquid chromatography/tandem mass spectrometry (HILIC/MS/MS). The devised method involved protein precipitation with acetonitrile followed by separation on an Atlantis HILIC silica column using an acetonitrile/ammonium formate mobile phase (100 mM, pH 3.0) (85:15, v/v). Analytes were detected using an electrospray ionization mass spectrometer in the multiple-reaction monitoring mode. The standard curve was linear (r = 1.000) over the concentration range of 50.0-10000 ng/mL. The lower limit of quantification for gabapentin was 50.0 ng/mL (ca. 20 pg gabapentin) using a 10-microL plasma sample. The coefficients of variation and relative errors for intra- and inter-assay at four QC levels (i.e., 50.0, 125, 750, and 7500 ng/mL) were 4.7 to 9.4% and -4.1 to 1.6%, respectively. Absolute and relative matrix effects for gabapentin and metformin were practically absent. Gabapentin and metformin recoveries were 98.5% and 99.0%, respectively. This method was successfully applied to a bioequivalence study of gabapentin in humans. 相似文献
4.
Hydrophilic interaction LC with MS/MS (HILIC-MS/MS) was described as a rapid, sensitive, and selective method for the quantification of doxazosin in human plasma. Doxazosin and cisapride (internal standard) were extracted from human plasma with ethyl acetate at alkaline pH and analyzed on an Atlantis HILIC Silica column with the mobile phase of ACN/ammonium formate (100 mM, pH 4.5) (93:7 v/v). The analytes were detected using an ESI MS/MS in the selective-reaction-monitoring mode. The standard curve was linear (r = 0.9994) over the concentration range of 0.2-50 ng/mL. The LOQ for doxazosin was 0.2 ng/mL using 100 microL plasma sample. The CV and relative error for intra- and interassay at four QC levels were 3.7-8.7% and 0.0-9.8%, respectively. The matrix effect for doxazosin and cisapride were practically absent. The recoveries of doxazosin and cisapride were 67.4 and 61.7%, respectively. This method was successfully applied to the pharmacokinetic study of doxazosin in humans. 相似文献
5.
Hayama T Yoshida H Todoroki K Nohta H Yamaguchi M 《Rapid communications in mass spectrometry : RCM》2008,22(14):2203-2210
A method combining hydrophilic interaction liquid chromatography (HILIC) with tandem mass spectrometry (MS/MS) was developed for the determination of polar organophosphorus pesticides (OPPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl, and vamidothion) in water samples. To extract the polar OPPs and minimize matrix effects from the water sample, an activated carbon cartridge was used for pretreatment. After pretreatment of the water sample, the eluate from the activated carbon cartridge was directly injected into the HILIC/MS/MS system. The OPPs were separated on an Atlantis HILIC silica column by isocratic elution with a mixture of acetonitrile, isopropanol, and ammonium formate buffer as a mobile phase, and they were detected by positive electrospray ionization MS/MS in the selected reaction monitoring mode. The method was validated at 0.05, 0.5, and 5 microg/L levels in water samples, and the recoveries of polar OPPs were between 76.4 and 98.6%. The limits of detection were between 0.13 and 1.0 pg on-column, and the limits of quantification were between 0.43 and 3.4 pg on-column. The method can be applied to the determination of trace amounts of OPPs in environmental water samples. 相似文献
6.
Carnitine is an endogenous quaternary amine whose primary function is to shuttle long chain fatty acids to the mitochondrial matrix, where they subsequently undergo beta oxidation. Accurate quantification of total and free carnitine is essential for the accurate diagnosis of a number of inborn errors of metabolism, including disorders of fatty acid oxidation as well as various organic acidurias. Early methods for carnitine measurement were enzyme based. Recently, liquid chromatography tandem mass spectrometry has become the method of choice for carnitine measurement. Typically, carnitine is derivitized to from a butyl ester, thus improving its ionization and retention characteristics. A potential problem with this approach is that the acidic conditions used to carry out the reaction may hydrolyze other acyl esters, resulting in ex-vivo artifacts. Consequently, we developed a hydrophobic interaction chromatography (HILIC) tandem mass spectrometry method for the quantification of carnitine. The use of HILIC allows for the derivitization step to be circumvented, while still allowing for favorable chromatographic performance. The method was shown to be accurate, precise, and robust. 相似文献
7.
A sensitive hydrophilic interaction liquid chromatography/electrospray ionization mass spectrometry (HILIC/ESI-MS/MS) method was developed for determination of selected aliphatic (i.e. malonic, succinic, glutaric, adipic, pimelic, suberic, azelaic, maleic, fumaric, glycolic and pyruvic acid), alicyclic (i.e. cis-pinonic and pinic acid) and aromatic (i.e. trimesic, phthalic acid and its isomers) carboxylic acids. Analytes were separated on an amide column using a gradient elution with a 10mM constant ionic strength mobile phase containing acetonitrile and aqueous ammonium acetate buffer (pH 5.0). The influence of the buffer type, pH, polar modifier and temperature on analyte retention under HILIC was studied. Static sonication-assisted solvent extraction was optimized for sample preparation prior to analysis. The recoveries obtained were higher than 90% for most analytes. The method was proven to be sensitive with limits of detection ranged from 0.03 to 16.0 μg/L in selected reaction monitoring mode (SRM). The repeatability and intermediate precision of the method, expressed as RSD (%) of the peak area ratio between analytes and their internal standards were generally lower than 5%. The method was successfully applied for determination of the studied acids in samples of ambient aerosol particles. A big advantage of the new method is also its ability to detect and separate the isobaric compounds of the selected carboxylic acids. Our results demonstrate that the method is specific and sensitive for the determination of a wider range of polar carboxylic acids at low concentrations in complex samples of aerosol particles. 相似文献
8.
A simple method was developed to determine histamine, an important compound in chemical food poisoning, by extraction followed by hydrophilic interaction chromatography-tandem mass spectrometry using a hydrophilic column with sulfobetaine-type zwitterion groups. The quantitation range in seafood products was from 0.4 to 200 mg kg(-1) for 5 g food samples. Quantitative recoveries were obtained with four types of seafood product. These results agreed well with those from the more complex, conventional HPLC method, which requires sample derivatization with dansyl chloride. 相似文献
9.
A hydrophilic interaction chromatographic (HILIC) system interfaced with atmospheric pressure ionization (API) sources and a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of nicotinic acid (NiAc) and its metabolites in dog plasma in support of a pharmacokinetic study. A silica column was adapted for separation of NiAc and its two metabolites, nicotinamide (NiNH2) and nicotinuric acid (NiUAc), under HILIC conditions. The influence of experimental factors such as the composition of mobile phase on ionization efficiency and chromatographic performance of all analytes was investigated. The feasibility of the proposed HILIC/MS/MS methods was explored by comparing the plasma levels of NiAc, NiNH2, and NiUAc in dog obtained by using either electrospray ionization or atmospheric pressure chemical ionization interfaces in positive ion mode. The methods were partially validated in terms of inter-day accuracy and precision, extraction recovery, benchtop and freeze/thaw stability. Further, the potential of ionization suppression resulting from endogenous components of the biological matrixes on the HILIC/API-MS/MS methods were investigated using the post-column infusion technique. 相似文献
10.
Analysis of ibuprofen enantiomers in rat plasma by liquid chromatography with tandem mass spectrometry 下载免费PDF全文
Juciane Lauren Cavalcanti Cardoso Vera Lucia Lanchote Maria Paula Marques Pereira Natália Valadares de Moraes José Salvador Lepera 《Journal of separation science》2014,37(8):944-949
A sensitive and selective method for the analysis of ibuprofen enantiomers by LC–MS/MS was developed and validated for the purpose of application in pharmacokinetic studies in small experimental animals. Aliquots of 200 μL plasma were submitted to liquid–liquid extraction with hexane/diisopropylether (50:50 v/v) in acid pH. Separation was accomplished in a Chirex® 3005 (250 × 4.6 mm, 5 μm) column at 25°C with a mobile phase that consisted of 0.01 M ammonium acetate in methanol at a flow rate of 1.1 mL/min. The mass spectrometer consisted of an ESI interface operating at negative ionization mode and multiple reaction monitoring. The transitions 205 > 161 and 240 > 197 were monitored for ibuprofen enantiomers and fenoprofen (internal standard), respectively. Method validation included the evaluation of the matrix effect, stability, linearity, lower LOQ, within‐run and between‐run precision, and accuracy. The lower LOQ was 25 ng/mL for each ibuprofen enantiomer, and the calibration curves showed good linearity in the range 0.025–50 μg/mL. The method was successfully applied in the investigation of pharmacokinetic disposition of ibuprofen enantiomers in rats treated orally with 25 mg/kg of the racemate. Enantioselective kinetic disposition was observed with accumulation of (+)‐(S)‐ibuprofen in rats following single oral administration. 相似文献
11.
Fast quantification of endogenous carbohydrates in plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry 下载免费PDF全文
Bangjie Zhu Feng Liu Xituo Li Yan Wang Xue Gu Jieyu Dai Guiming Wang Chao Yan 《Journal of separation science》2015,38(1):34-41
Endogenous carbohydrates in biosamples are frequently highlighted as the most differential metabolites in many metabolomics studies. A simple, fast, simultaneous quantitative method for 16 endogenous carbohydrates in plasma has been developed using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. In order to quantify 16 endogenous carbohydrates in plasma, various conditions, including columns, chromatographic conditions, mass spectrometry conditions, and plasma preparation methods, were investigated. Different conditions in this quantified analysis were performed and optimized. The reproducibility, precision, recovery, matrix effect, and stability of the method were verified. The results indicated that a methanol/acetonitrile (50:50, v/v) mixture could effectively and reproducibly precipitate rat plasma proteins. Cold organic solvents coupled with vortex for 1 min and incubated at –20°C for 20 min were the most optimal conditions for protein precipitation and extraction. The results, according to the linearity, recovery, precision, matrix effect, and stability, showed that the method was satisfactory in the quantification of endogenous carbohydrates in rat plasma. The quantified analysis of endogenous carbohydrates in rat plasma performed excellently in terms of sensitivity, high throughput, and simple sample preparation, which met the requirement of quantification in specific expanded metabolomic studies after the global metabolic profiling research. 相似文献
12.
Y Zhao RP Kong G Li MP Lam CH Law SM Lee HC Lam IK Chu 《Journal of separation science》2012,35(14):1755-1763
We have developed a fully automatable two-dimensional liquid chromatography platform for shotgun proteomics analyses based on the online coupling of hydrophilic interaction liquid chromatography (HILIC) - using a nonionic type of TSKgel Amide 80 at either pH 6.8 (neutral) or 2.7 (acidic) - with conventional low-pH reversed-phase chromatography. Online coupling of the neutral-pH HILIC and reversed phase chromatography systems outperformed the acidic HILIC-reversed phase chromatography combination, resulting in 18.4% (1914 versus 1617 nonredundant proteins) and 41.6% (12,989 versus 9172 unique peptides) increases in the number of identified peptides and proteins from duplicate analyses of Rat pheochromocytoma lysates. Armed with this optimized HILIC-reversed phase liquid chromatography platform, we identified 2554 nonredundant proteins from duplicate analyses of a Saccharomyces cerevisiae lysate, with the detected protein abundances spanning from approximately 41 to 10(6) copies per cell, which contained up to approximately 2092 different validated protein species with a dynamic range of concentrations of up to approximately 10(4) . This present study establishes a fully automated platform as a promising methodology to enable online coupling of different hydrophilic HILIC and reversed phase chromatography systems, thereby expanding the repertoire of multidimensional liquid chromatography for shotgun proteomics. 相似文献
13.
Aldini G Orioli M Carini M Maffei Facino R 《Journal of mass spectrometry : JMS》2004,39(12):1417-1428
The histidine-containing dipeptides carnosine (CAR) and structurally related anserine (ANS) and homocarnosine (HCAR), widely distributed in vertebrate organisms, have recently been proposed as endogenous quenchers for highly cytotoxic alpha,beta-unsaturated aldehydes generated by peroxidation. A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay was developed and validated for the simultaneous determination of these peptides in biological matrices in order to establish their plasma/tissue distribution. Samples (plasma or tissue homogenates from male rats) were prepared by protein precipitation with HClO(4) (1 : 1, v/v) containing H-Tyr-His-OH as internal standard. The supernatant was separated on a Phenomenex Sinergy polar-RP column with a mobile phase of water-acetonitrile-heptafluorobutyric acid (9 : 1 : 0.01, v/v/v) at a flow-rate of 0.2 ml min(-1), with a run time of 10 min. Detection was effected on an ion trap mass spectrometer equipped with an electrospray ionization interface operating in positive ionization mode. The acquisitions were in the multiple reaction monitoring mode using the following precursor --> product ion combinations: H-Tyr-His-OH (internal standard) m/z 319 --> 301; CAR m/z 227 --> 210 + 209; ANS m/z 241 --> 224 + 197 + 170; HCAR m/z 241 --> 156. The method was validated over the concentration range 15-1000 nmol g(-1) and the limit of quantification (LOQ) and limit of detection (LOD) were 12.5 and 4.2 pmol injected, respectively. The intra- and inter-day precisions were <10% (< or =17.47% at the LOQ) and the intra- and inter-assay accuracies were within +/-10% for all concentrations. The mapping profile in rat tissue gave the following results: the highest concentrations of CAR and ANS were found in skeletal muscles (soleus, gastrocnemius, tibialis), followed by the heart, cerebellum and brain (ANS below the LOQ). HCAR was found only in the brain and cerebellum. No histidine-containing dipeptides were detectable in plasma, liver, kidney and lung. 相似文献
14.
In this work a LC–MS/MS method for the determination of two quaternary ammonium growth regulators (chlormequat and mepiquat) in food is reported. The separation was based on hydrophilic interaction liquid chromatography (HILIC) without the use of ion-pair reagents. A gradient elution of acetonitrile and formic acid/ammonium formate buffer from 60 to 40% acetonitrile was enough to achieve a resolution >1.5 in less than 4.0 min. The HILIC system was coupled to a triple quadrupole mass spectrometer equipped with a heated electrospray probe (H-ESI) providing sub-pg LODs in SRM mode. A straightforward sample treatment (SPE C18 clean-up) was enough to provide MLODs at low ppb levels when analysing a range of food samples that covered different kinds of matrices such as fresh fruit, vegetables, fruit juices, baby food, bread, coffee and beer. Chlormequat was found in seven samples (0.8–126 ng/g) but mepiquat was only detected in bread and coffee samples (0.9–166 ng/g). 相似文献
15.
A screening method for the analysis of seven anti-viral drugs in poultry tissue has been developed. These include anti-influenza drugs (amantadine, rimantadine, zanamivir and oseltamivir and its carboxylate metabolite), anti-herpes drugs (acyclovir and ganciclovir) and an immunomodulator (imiquimod). Poultry tissue was extracted in acetonitrile:water:acetic acid. After sample purification, using a strong cation exchange column, the eluate was split into two fractions. The first portion was dissolved in methanol:water and the second in acetonitrile:methanol:water. Both fractions were analysed on a zwitterionic hydrophilic interaction liquid chromatography column coupled to a triple quadrupole mass spectrometer. The screening method was successfully validated according to Commission Decision 2002/657/EC in three different laboratories with CCβ concentrations of ≤10 μg kg(-1). 相似文献
16.
《Biomedical chromatography : BMC》2017,31(2)
A rapid and sensitive LC–MS/MS method was developed and validated for the simultaneous determination of buprenorphine and its three metabolites (buprenorphine glucuronide, norbuprenorphine and norbuprenorphine glucuronide) as well as naloxone and its metabolite naloxone glucuronide in the rat plasma. A hydrophilic interaction chromatography column and a mobile phase containing acetonitrile and ammonium formate buffer (pH 3.5) were used for the chromatographic separation. Mass spectrometric detection was achieved by an electrospray ionization source in the positive mode coupled to a triple quadrupole mass analyzer. The calibration curves for the six analytes displayed good linearity over the concentration range 1.0 or 5.0–1000 ng/mL. The intra and inter‐day precision (CV) ranged from 2.68 to 16.4% and from 9.02 to 14.5%, respectively. The intra‐ and inter‐day accuracy (bias) ranged from −14.2 to 15.2% and from −9.00 to 4.80%, respectively. The extraction recoveries for all the analytes ranged from 55 to 86.9%. The LC–MS/MS method was successfully applied to a pharmacokinetic study of buprenorphine–naloxone combination in rats. 相似文献
17.
Alnouti Y Lewis SR White CA Bartlett MG 《Rapid communications in mass spectrometry : RCM》2005,19(4):503-508
A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the simultaneous determination of zidovudine (AZT) and lamivudine (3TC) in rat plasma, amniotic fluid, placental, and fetal tissues. Samples were processed by acetonitrile precipitation. Chromatography was performed using a C18 column (5 microm, 150 x 3.9 mm i.d). The mobile phase consisted of 30% methanol and 7.5 mM ammonium acetate (pH 6.5). The method was validated in the range of 0.05-25 microg/mL for both 3TC and AZT in the four biological matrices. Finally, the method was applied to a study involving fetal transport following co-administration of these compounds at a dose of 25 mg/kg each in a pregnant rat. 相似文献
18.
The purpose of this study was to develop and validate a method for the determination of clavulanic acid (CLAV) residues in edible tissues of swine by liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). After a simple extraction of CLAV using an aqueous phosphate buffer solution of pH 6.0, an ultrafiltration step was performed for protein removal. Chromatography of CLAV and the internal standard tazobactam (TAZO) was achieved on a reversed-phase PLRP-S polymeric column (150 mm × 2.1 mm i.d., 100 Å) using a mixture of 0.05 (v/v)% formic acid in water and acetonitrile. The mass spectrometer was operated in the MS/MS selected reaction monitoring (SRM) mode. The method was validated for the analysis of porcine muscle, skin plus fat, liver and kidney, according to the requirements defined by the European Community. Calibration curves were prepared for all tissues and good linearity was achieved over the concentration ranges tested (correlation coefficient ≥0.99 and goodness-of-fit coefficient ≤10%). Limits of quantification of 50 ng g−1 were obtained for the analysis of CLAV in the various tissues which corresponds in all cases to at least half the maximum residue limits (MRLs). Limits of detection ranged between 8.0 and 15.14 ng g−1. The within-day, between-day precisions and trueness fell within the ranges specified in the EMEA/CVMP/573-00/FINAL document. Biological samples from pigs that received an oral or intravenous bolus of a commercial amoxicillin/clavulanic acid formulation were analyzed using the described method. 相似文献
19.
Ximei Wu Weixiong Huang Lin Lu Li Lin Xingfen Yang 《Analytical and bioanalytical chemistry》2010,398(3):1319-1327
A method was developed for the simultaneous determination of six toxic alkaloids (aconitine, hypaconitine, gelsemine, raceanisodamine,
strychnine, brucine) in blood and urine by hydrophilic interaction liquid chromatography (HILIC) coupled with electrospray
tandem mass spectrometry. Ephedrine was selected as the internal standard. Samples were extracted and cleaned up by solid-phase
extraction (SPE) using Oasis MCX cartridges. Separation parameters such as organic modifier, buffer pH, and concentration
of buffer salt were investigated. Gradient separation and analysis were achieved for six alkaloids on a 3-μm Atlantis HILIC
column using a mobile phase consisting of 30 mM ammonium formate and acetonitrile at pH 3. Two multiple reaction monitoring
(MRM) transitions for each substance were monitored to provide sufficient identification of alkaloid. The retention mechanisms
were explored in the method development. Validation included assessment of linearity, limit of quantification, accuracy, and
precision. Bias was less than 15.1% and precision was better than 8.3% for both blood and urine samples. A total of 54 clinical
samples were examined by this validated method. 相似文献
20.
Crnogorac G Schmauder S Schwack W 《Rapid communications in mass spectrometry : RCM》2008,22(16):2539-2546
The simultaneous determination of dithiocarbamate (DTC) fungicide residues on fruits and vegetables was performed by liquid chromatography (LC) on a ZIC-pHILIC column coupled to tandem mass spectrometry (MS/MS). For each DTC subclass, i.e. dimethyldithiocarbamates (DMDs), ethylenebis(dithiocarbamates) (EBDs), and propylenebis(dithiocarbamates) (PBDs), the limits of detection and quantification were approximately 0.001 and 0.005 mg kg(-1), respectively. Recoveries from tomatoes, spiked in the range of 0.05-1 mg kg(-1), averaged between 97 and 101%. Several fruits and vegetables from a local market and different countries of origin (apples, pears, grapes, cherry tomatoes, cocktail tomatoes, cucumbers, tomatoes, tamarillos, papaya, and broccoli) were analyzed by LC/MS/MS, LC/MS, and by the routine CS(2) method. In general, the results obtained by both LC/MS and LC/MS/MS were in good agreement with those obtained by the CS(2) method except for the false positive CS(2) results for broccoli and papaya. The results demonstrate that both LC/MS and LC/MS/MS can be used for routine analyses of DTC residues, whereas LC/MS/MS is more sensitive and selective than LC/MS. 相似文献