首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel method for the determination of residual solvents in pharmaceuticals by thermal desorption (TD)-GC/MS has been established. A programmed temperature pyrolyzer (double shot pyrolyzer) is applied for the TD. This method does not require any sample pretreatment and allows very small amounts of the sample. Directly desorbed solvents from intact pharmaceuticals (ca. 1 mg) in the desorption cup (5 mm x 3.8 mm i.d.) were cryofocused at the head of a capillary column prior to a GC/MS analysis. The desorption temperature was set at a point about 20 degrees C higher than the melting point of each sample individually, and held for 3 min. The analytical results using 7 different pharmaceuticals were in agreement with those obtained by direct injection (DI) of the solution, followed by USP XXIII. This proposed TD-GC/MS method was demonstrated to be very useful for the identification and quantification of residual solvents. Furthermore, this method was simple, allowed rapid analysis and gave good repeatability.  相似文献   

2.
A convenient analytical method for the simultaneous determination of more than 40 pharmaceuticals belonging to various therapeutic categories in whole blood has been developed. Exemplarily, the method was fully validated for eight different pharmaceuticals. The procedure entails addition of acetonitrile, magnesium sulfate and sodium chloride to a small amount of blood, then the mixture is shaken intensively and centrifuged for phase separation. An aliquot of the organic layer is cleaned up by dispersive solid-phase extraction employing bulk sorbents as well as magnesium sulfate for the removal of residual water. This method was based on the QuEChERS approach developed for pesticide residue analysis in food. Gas chromatography/ion trap mass spectrometry (GC/MS) with electron (EI) and chemical (CI) ionisation was then used for qualitative and quantitative determination of the pharmaceuticals. The dispersive SPE with PSA (sorbent functionalized with primary and secondary amines) was found more suitable than aminopropyl and a styrene-divinylbenzene sorbent for sample clean-up before drug level determination in whole blood and plasma, as it was found that most of endogenous matrix components were removed and the analytes were isolated from spiked samples with recoveries above 80%. Variation coefficients of the repeatability typically smaller than 10% have been achieved for a wide range of the investigated substances. The used analytical conditions allowed to separate successively a variety of drugs and poisons with the typical limit of detection at <20 ng mL(-1) levels using 1 microL injection of equivalent blood sample in whole blood. The method is simple, rapid, cheap and very effective for therapeutic drug monitoring and forensic chemistry.  相似文献   

3.
Thermal desorption gas chromatograph mass spectrometry (TD GC/MS) was used to study weight loss in thermogravimetric analysis (TGA). The technique of thermal desorption utilizes the same temperature heating rate as the TGA to thermally desorb volatiles from solid sample matrices. Volatiles were cryo-trapped at −60 °C. After thermal desorption is complete, the trapped volatiles are separated by a GC capillary column and identified by mass spectrometry. In this study, the TD GC/MS was applied in pharmaceutical development to understand the chemical reactions attributed to the weight loss in the thermal decomposition of two dicarboxylic acid salts of a drug substance. These two salts exhibited different thermal stabilities. The thermally induced chemical reactions obtained from these two salts included dehydration and decarboxylation. Thermal degradation compounds were identified and reaction pathways for decomposition were proposed. The stability of the salts is dependent on the identity of the dicarboxylic acids from which they were generated. The information obtained from TD GC/MS helps better understand the weight loss process in thermogravimetric analysis.  相似文献   

4.
A novel fused silica capillary GC/MS direct coupling is described which ensures quantitative transfer of sample from the point of injection to the ion source of a mass spectrometer without contacting any surfaces other than the column wall. This device permits GC analysis of highly labile substances. Aflatoxin B1, previously considered unassayable by GC, can now be determined by GC/MS.  相似文献   

5.
气相色谱/质谱法鉴定甲基异丁基酮产品中的杂质组分   总被引:1,自引:0,他引:1  
梁力  钱仰东 《分析化学》1998,26(8):1004-1006
采用GC/MS联用技术分离出甲基异丁基酮产品中6个杂质峰。将标准图谱库,质量色谱图等手段结合起来鉴定出7种杂质,并用标样,双柱对部分GC/MS的结果进行了证实,为产品质量控制提供依据。  相似文献   

6.
大口径毛细管气相色谱检查药物中残留溶剂的方法研究   总被引:8,自引:0,他引:8  
姚倩  李章万  张强  叶利民 《色谱》2001,19(2):141-143
 以药物合成中常用的 16种有机溶剂为研究对象 ,建立了用大口径毛细管柱检查残留有机溶剂的气相色谱法 ,并考察了不同极性的色谱柱及不同提取溶剂对分离与检测的影响。实验表明 ,根据原料药合成中可能存在的残留溶剂 ,选用适当的提取溶剂 ,采用大口径毛细管气相色谱法检查 ,可获得较满意的结果。  相似文献   

7.
Benzyl alcohol used as the sample preparation solvent in the determination of residual solvents in pharmaceutical bulks yielded benzene, toluene, and benzaldehyde on capillary gas chromatography (GC) by sonication. The factors responsible for compounds generated are discussed. The quality of benzyl alcohol and the type of sonicator were not involved in the generation of benzene, toluene, and benzaldehyde, whereas matrix contributions were observed. The degradation profiles of benzyl alcohol and its analogous compounds obtained by pyrolysis-GC/mass spectrometric analysis were similar to those obtained by sonication, suggesting that benzyl alcohol is degraded by the high local heat generated by sonication. Consequently, no matter how long it may take to dissolve bulk substances in benzyl alcohol completely, we do not recommend the use of a sonicator in sample preparation for the determination of residual solvents in pharmaceutical bulks.  相似文献   

8.
An analytical method using fractionated pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and applied for characterizing the type of interaction between 1-hydroxybenzotriazole (HBT)-mediator and pulp lignin in laccase delignification of pulp. In fractionated pyrolysis, the sample is pyrolyzed at progressively increasing temperatures in order to study particular fractions of the sample and to minimize secondary pyrolysis effects. This makes it possible to determine whether a certain pyrolysis product originates from one chemical moiety or different chemical moieties in one molecule. In the present method, samples were fractionated by thermal desorption at 200 °C followed by pyrolysis at progressively increasing temperatures from 320 to 800 °C. The products formed in each fraction were separated in a capillary GC column and detected and identified using MS. The type of interaction between HBT and pulp lignin was studied by following the formation of nitrogen-containing products during fractionated pyrolysis of a residual lignin isolated from laccase/HBT-treated oxygen-delignified softwood kraft pulp. This residual lignin was found to contain approximately 2% HBT residue. Most (87%) of this residue was covalently linked to the residual lignin. The results also strongly suggest that the HBT residue is present in two chemically different forms.  相似文献   

9.
刘永明  葛娜  王飞  李金  吴艳萍  黄学者  曹彦忠 《色谱》2012,30(8):782-791
建立了顶空气相色谱-质谱(HS-GC/MS)同时测定蜂蜜中57种挥发性有机溶剂(包括烷烃类、芳香烃类、醇类、酮类、酯类、醚类)残留量的分析方法。蜂蜜样品在密封的顶空瓶中用水溶解后,在顶空仪中于80 ℃下平衡30 min,使气-液两相达到动态平衡。采用DB-624毛细管色谱柱(60 m×0.25 mm×1.40 μm)对57种有机溶剂进行分离,GC/MS测定,外标法定量。该方法对于烷烃类、芳香烃类和醚类挥发性有机溶剂在0.005~0.2 μg、酯类0.05~2.0 μg、酮类0.5~20 μg、醇类2.5~100 μg范围内线性关系良好,相关系数均大于0.996。对于烷烃类、芳香烃类和醚类挥发性有机溶剂在1.0~20 μg/kg、酯类10~200 μg/kg、酮类100~2000 μg/kg、醇类500~10000 μg/kg添加范围内的平均添加回收率为61.0%~113.1%,相对标准偏差为1.9%~9.8%。对于烷烃类、芳香烃类和醚类挥发性有机溶剂的检出限为1.0 μg/kg、酯类10 μg/kg、酮类100 μg/kg、醇类500 μg/kg。该方法操作简单、快速,灵敏度和准确度高,适用于蜂蜜样品中多种挥发性有机溶剂残留量的同时检测。  相似文献   

10.
A method using purge-and-membrane mass spectrometry (PAM-MS) was developed for the analysis of residual solvents in pharmaceutical products. The method combines dynamic headspace and membrane inlet mass spectrometry. The limits of detection for the compounds studied, benzene, toluene, chloroform, 2-pentene and 2-methyl- and 3-methylpentane, were 0.05-0.1 mg/kg. In quantitative analysis the method showed good linearity (r(2) > 0.998) and acceptable within-day (RSD = 7.9-18%) and between-day (RSD = 6.8-10%) repeatability. The PAM-MS method combined with the custom-made Solver program was compared with a method using purge-and-trap gas chromatography/mass spectrometry (P&T-GC/MS) for identification of residual solvents from authentic samples. The results showed that PAM-MS/Solver provides reliable identification of the main volatile organic compounds (VOCs) in the pharmaceuticals, but VOCs with low concentrations (below 0.5 mg/kg) were better identified by P&T-GC/MS. Other advantages of the PAM-MS method were short analysis times and non-requirement for pre-treatment of samples.  相似文献   

11.
In studies of the phenolic compounds present in leaves and needles, GC and GC–MS have so far been applied only sporadically. This is probably because of the greater difficulties encountered in preparing the samples for this method than those used for liquid chromatography. When preparing a sample for gas chromatography the analyst is faced with two difficult stages—separation of the compound from the matrix without losses (stage 1) so that the final sample can be derivatized to make it suitable for analysis on a non-polar capillary column of the gas chromatograph (stage 2). This paper presents a procedure for extraction of phenolic compounds from the matrix by means of a Florisil/C18 sorbent system and their analysis by GC. After passage through the adsorbents the recovery ranges from 32% for ferulic acid to 88% for gentisic acid. It was found that this extraction method and the GC analysis are very precise (particularly for samples of a mass <1 g) and can be used for quantification. The high-precision quantification of 15 phenolic acids, shikimic acid, and six other compounds present in pine needles has been achieved. The conditions used for GC analysis and construction of calibration curves for quantitative determination are given.  相似文献   

12.
A multiresidue method for screening endocrine-disrupting chemicals (EDCs) and pharmaceuticals in aqueous samples is presented. Four 10-mL aliquots of water were taken for stir bar sorptive extraction (SBSE) and they were treated in the following way. In sample one, in situ derivatization was performed with acetic acid anhydride to improve the extraction efficiencies and chromatographic analysis of phenolic compounds. For the same reasons, aliquot two was treated with ethyl chloroformate to improve amine and acid extraction and analysis, and aliquot three with tetraethylborate to enhance organotin compound extraction and analysis. Methanol was added to sample four to stop adsorption of apolar solutes on the wall. After SBSE, the four stir bars, together with a plug of glass wool impregnated with bis(trimethylylsilyl)trifluoroacetamide (BSTFA) to derivatize hydroxyl functionalities, were introduced into the same thermal desorption tube, heat-desorbed, and analyzed simultaneously by capillary GC/MS. The figures of merit of the method were evaluated with an EDC model mixture. In scan-mode MS, the limits of detection (LODs) were in the range 1–500 ng/L, while the LODs dropped by a factor of 50–100 when ion monitoring MS was applied to the targets. The performance of the method was illustrated by analysing some real-world water samples.  相似文献   

13.
A multiresidue method for the determination of more than 80 pesticides in water has been developed and validated. The proposed method is based on SPE followed by GC coupled to MS/MS. Different variables affecting SPE procedure, such as cartridges, sample volume and solvents were studied, and mass spectrometric conditions were optimised in order to increase selectivity and sensitivity. Calibration curves were linear over the range of 0.03-0.5 microg/L. Recoveries were in the range of 70-110% and repeatability was below 20% for the lowest calibration point. LODs ranged from 0.001 to 0.025 microg/L and LOQs from 0.003 to 0.076 microg/L. Finally, the method was successfully applied to the analysis of water samples from southeast of Spain.  相似文献   

14.
The presence of pharmaceuticals and other wastewater-derived micropollutants in surface and groundwaters is receiving intense public and scientific attention. Yet simple GC/MS methods that would enable measurement of a wide range of such compounds are scarce. This paper describes a GC/MS method for the simultaneous determination of 13 pharmaceuticals (acetaminophen, albuterol, allopurinol, amitriptyline, brompheniramine, carbamazepine, carisoprodol, ciclopirox, diazepam, fenofibrate, metoprolol, primidone, and terbinafine) and 5 wastewater-derived contaminants (caffeine, diethyltoluamide, n-butylbenzene sulfonamide, n-nonylphenol, and n-octylphenol) by solid phase extraction (SPE) and derivatization with BSTFA. The method was applied to the analysis of raw and treated sewage samples obtained from a wastewater treatment plant located in the mid-Atlantic United States. All analytes were detected in untreated sewage, and 14 of the 18 analytes were detected in treated sewage.  相似文献   

15.
Summary A method for determination of the composition of the light oil fractions in high-temperature coal tar by means of distillation, followed by gas chromatography on a crosslinked fused-silica, capillary column coated with optimum amount of stationary phase and identification by capillary gas chromatography/Fourier transform infrared spectrometry combined with GC retention indices (GC/FTIR-RI) is described. This method was effectively used to identify complex mixture such as coal tar without any standard samples, especially, adapted for isomeric compounds. More than 60 and 50 compounds were also separated and identified respectively in light oil fractions. This shows the capability of the capillary GC/FTIR combined with GC retention indices to identify isomers not accomplished by GC/MS.  相似文献   

16.
A simple and sensitive gas chromatography/tandem mass spectrometry (GC/MS/MS) method is described for the detection of anabolic steroids, usually found in keratin matrix at very low concentrations. Hair samples from seven athletes who spontaneously reported their abuse of anabolic steroids, and in a single case cocaine, were analyzed for methyltestosterone, nandrolone, boldenone, fluoxymesterolone, cocaine and its metabolite benzoylecgonine. Anabolic steroids were determinate by digestion of hair samples in 1 m NaOH for 15 min at 95 degrees C. After cooling, samples were purificated by solid-phase and liquid-liquid extraction, then anabolic steroids were converted to their trimethylsilyl derivative and finally analyzed by GC/MS/MS. For detection of cocaine and benzoylecgonine, hair samples were extracted with methanol in an ultrasonic bath for 2 h at 56 degrees C then overnight in a thermostatic bath at the same temperature. After the incubation, methanol was evaporated to dryness, and benzoylecgonine was converted to its trimethylsilyl derivative prior of GC/MS/MS analysis. Results obtained are in agreement with the athletes' reports, confirming that hair is a valid biological matrix to establish long-term intake of drugs.  相似文献   

17.
An integrated gas chromatography/Fourier transform infrared spectrometry (GC/FT-IR) system developed for the analysis of environmental pollutants is described. The versatility of the system allows the utilization of many different techniques of sample introduction and manipulation during analysis. The sample can be introduced by direct injection or thermal desorption from an adsorbent cartridge, and can then be separated on one of two capillary columns and detected by FT-IR or an FID. Cold traps and collection cartridges incorporated in the system permit recovery and additional fractionation of samples. Recovered sample and sample fractions can then be re-analyzed by GC/FT-IR or subsequently analyzed by GC/MS or other methods.  相似文献   

18.
Erythrocyte alkylresorcinols (5‐alkyl‐1,3‐dihydroxybenzenes) are potential biomarkers of wholegrain wheat and rye intake. However, their high‐throughput quantitative analysis by gas chromatography/mass spectrometry (GC/MS) is hindered by the time‐consuming sample preparation and, more importantly, by interfering compounds that still remain after sample cleanup. In the present work we describe a gas chromatography/tandem mass spectrometry (GC/MS/MS) method for the rapid and reliable quantification of alkylresorcinols in erythrocyte samples. The performance of the GC/MS/MS method is compared with that of GC/MS. The main characteristics of the method are: lower limits of detection: 2–10 µg/L standard solution; lower limits of quantification: 6–30 µg/L standard solution; linearity coefficients: 0.9611–0.9888; linear ranges: 2–20 µg/L in erythrocytes; and intra‐day precisions (n = 6): 4–13% at endogenous analyte levels in non‐spiked erythrocytes. Tandem mass spectrometry showed greatly improved selectivity over single‐stage mass spectrometry in the case of erythrocyte samples, eliminating all interferences detectable in single‐stage MS and enabling simple peak integration for quantification. Moreover, increased selectivity resulted in GC separation speeded up by a factor of two, allowing the duplicate analysis of over 40 samples per day. This GC/MS/MS method is suggested as an improved alternative to GC/MS for the quantification of alkylresorcinols in erythrocytes for assessing wholegrain wheat and rye intake. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
A pyrolyzer gas chromatography/mass spectrometry (GC/MS) method eliminates toxic solvents that burden our environment and can address the crucial problem of the solvent extraction GC/MS method. The purpose of this study is to establish an efficient quantitative analysis method for 10 phthalates that are regulated by the several governments. A change of concentrations over time for phthalates and internal standards was measured to verify the feasibility of using an auto sampler that facilitates analyzing multiple samples. Both standards maintained constant concentrations over the appropriate time for analysis. A certified reference material under the auspices of the Korea Research Institute of Standards and Science was used to verify the calibration curve obtained by the pyrolyzer GC/MS method, and a deviation was considered similar to the solvent extraction GC/MS method. Then, the limit of detection and limit of quantitation values were confirmed for various consumer products. To verify the reliability of the method, a comparative test with several accredited testing institutes was conducted, and the results were within the standard deviations of the results provided by the institutes. These results indicate that the pyrolyzer GC/MS method can be used in not only screening but also in accurate quantitative analysis.  相似文献   

20.
水果中三唑酮残留量的气相色谱和气相色谱—质谱分析   总被引:10,自引:0,他引:10  
周昱  林立毅 《分析化学》1997,25(5):510-514
水果中三唑酮残留用丙酮提取,经液-液分配净化,用气相色谱-电子捕获检测器测定,并用相色谱-质谱进行确证以HP-5大口径毛细管柱和HP-5MS毛细管柱为分离柱,选择出合适的色谱条件。三唑酮的分离效果良好。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号