首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
2.

Editorial

Focus on Fourier transform ion cyclotron resonance mass spectrometry  相似文献   

3.
Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) achieves high resolution and mass accuracy, allowing the identification of the raw chemical formulae of ions in complex samples. Using ion isolation and fragmentation (MS/MS), we can obtain more structural information, but MS/MS is time- and sample-consuming because each ion must be isolated before fragmentation. In 1987, Pfändler et al. proposed an experiment for 2D FT-ICR MS in order to fragment ions without isolating them and to visualize the fragmentations of complex samples in a single 2D mass spectrum, like 2D NMR spectroscopy. Because of limitations of electronics and computers, few studies have been conducted with this technique. The improvement of modern computers and the use of digital electronics for FT-ICR hardware now make it possible to acquire 2D mass spectra over a broad mass range. The original experiments used in-cell collision-induced dissociation, which caused a loss of resolution. Gas-free fragmentation modes such as infrared multiphoton dissociation and electron capture dissociation allow one to measure high-resolution 2D mass spectra. Consequently, there is renewed interest to develop 2D FT-ICR MS into an efficient analytical method. Improvements introduced in 2D NMR spectroscopy can also be transposed to 2D FT-ICR MS. We describe the history of 2D FT-ICR MS, introduce recent improvements, and present analytical applications to map the fragmentation of peptides. Finally, we provide a glossary which defines a few keywords for the 2D FT-ICR MS field.  相似文献   

4.
Mass spectrometry imaging (MSI) is a powerful tool in metabolomics and proteomics for the spatial localization and identification of pharmaceuticals, metabolites, lipids, peptides and proteins in biological tissues. However, sample preparation remains a crucial variable in obtaining the most accurate distributions. Common washing steps used to remove salts, and solvent-based matrix application, allow analyte spreading to occur. Solvent-free matrix applications can reduce this risk, but increase the possibility of ionisation bias due to matrix adhesion to tissue sections. We report here the use of matrix-free MSI using laser desorption ionisation performed on a 12 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. We used unprocessed tissue with no post-processing following thaw-mounting on matrix-assisted laser desorption ionisation (MALDI) indium-tin oxide (ITO) target plates. The identification and distribution of a range of phospholipids in mouse brain and kidney sections are presented and compared with previously published MALDI time-of-flight (TOF) MSI distributions.  相似文献   

5.
Controlled in-source ion-molecule reactions are performed for the first time in an external matrix assisted laser desorption ionization (MALDI) source of a Fourier transform ion cyclotron resonance mass spectrometer. The MALDI source with a hexapole ion guide that was originally designed to incorporate pulsed gas to collisionally cool ions (Baykut, G.; Jertz, R.; Witt, M. Rapid Commun. Mass Spectrom. 2000, 14, 1238-1247) has been modified to allow the study of in-source ion-molecule reactions. Upon laser desorption, a reaction gas was introduced through a second inlet and allowed to interact with the MALDI-generated ions trapped in the hexapole ion guide. Performing ion-molecule reactions in the high pressure range of the ion source prior to analysis in the ion cyclotron resonance (ICR) cell allows to maintain the ultra high vacuum in the cell which is crucial for high mass resolution measurements. In addition, due to the reaction gas pressure in the hexapole product ion formation is much faster than would be otherwise possible in the ICR cell. H/D exchange reactions with different peptides are investigated, as are proton-bound complex formations. A typical experimental sequence would be ion accumulation in the hexapole ion guide from multiple laser shots, addition of cooling gas during ion formation, addition of reaction gas, varied time delays for the ion-molecule reactions, and transmission of the product ions into the ICR cell for mass analysis. In this MALDI source H/D exchange reactions for different protonated peptides are investigated, as well as proton-bound complex formations with the reaction gas triethylamine. Amino acid sequence, structural flexibility and folding state of the peptides can be seen to play a part in the reactivity of such ions.  相似文献   

6.
Peak coalescence, i.e. the merging of two close peaks in a Fourier transform ion cyclotron resonance (FTICR) mass spectrum at a high number of ions, plays an important role in various FTICR experiments. In order to describe the coalescence phenomenon we would like to propose a new theory of motion for ion clouds with close mass‐to‐charge ratios, driven by a uniform magnetic field and Coulomb interactions between the clouds. We describe the motion of the ion clouds in terms of their averaged drift motion in crossed magnetic and electric fields. The ion clouds are considered to be of constant size and their motion is studied in two dimensions. The theory deals with the first‐order approximation of the equations of motion in relation to dm/m, where dm is the mass difference and m is the mass of a single ion. The analysis was done for an arbitrary inter‐cloud interaction potential, which makes it possible to analyze finite‐size ion clouds of any shape. The final analytical expression for the condition of the onset of coalescence is found for the case of uniformly charged spheres. An algorithm for finding this condition for an arbitrary interaction potential is proposed. The critical number of ions for the peak coalescence to take place is shown to depend quadratically on the magnetic field strength and to be proportional to the cyclotron radius and inversely proportional to the ion masses. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
8.
Liquid separation methods in combination with electrospray mass spectrometry as well as the recently introduced fragmentation method electron capture dissociation (ECD) have become powerful tools in proteomics research. This paper presents the results of the first successful attempts to combine liquid chromatography (LC) and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with ECD in the analysis of a mixture of standard peptides and of a bovine serum albumin tryptic digest. A novel electron injection system provided conditions for ECD sufficient to yield extensive sequence information for the most abundant peptides in the mixtures on the time-scale of the chromatographic separation. The results suggest that LC/ECD-FTICRMS can be employed in the characterization of peptides in enzymatic digests of proteins or protein mixtures and identify and localize posttranslational modifications.  相似文献   

9.
A novel strategy was developed to extend the application of electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) to the analysis of long-chain polysaccharides. High molecular weight polydisperse maltodextrins (poly-alpha(1-4) glucose) and dextrans (poly-alpha(1-6) glucose) were chosen as model compounds in the present study. Increased ionization efficiency of these mixtures in the positive ion mode was achieved upon modification of their reducing end with nitrogen-containing groups. The derivatization method is based on the formation of a new C--N bond between 1,6-hexamethylenediamine (HMD) and the reducing end of the polysaccharide, which exists in solution as an equilibrium between the hemiacetal and the open-ring aldehyde form. To achieve the chemical modification of the reducing end, two synthetic pathways were developed: (i) coupling of HMD by reductive amination and (ii) oxidation of the hemiacetal to lactone, followed by ring opening by HMD to yield the maltodextrin lactonamide of 1,6-hexanediamine (HMMD). Amino-functionalized polysaccharides were analyzed by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FTICR-MS) in the positive ion mode by direct flow injection. The hexamethylenediamine (HMD) and maltodextrin lactonamide of 1,6-hexanediamine (HMMD) moieties provide increased proton affinities which dramatically improve the detection of the long-chain polysaccharides by FTICR-MS. The present approach allowed for identification of single components in mixtures with prominent heterogeneity in the degree of polymerization (DP), without the need for chromatographic separation prior to MS. The high mass accuracy was essential for the unambiguous characterization of the species observed in the analyzed mixtures. Furthermore, molecular components containing up to 42 glucose residues were detected, representing the largest polysaccharide chains analyzed so far by ESI FTICR-MS.  相似文献   

10.
A new method for application of quadrupolar excitation to the trapped ion cell of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer is presented. Quadrupolar excitation is conventionally applied to the two pairs of opposed electrodes that normally perform the excitation and detection functions in the FTICR experiment. Symmetry arguments and numerically calculated isopotential contours within the trapped ion cell lead to the conclusion that quadrupolar excitation can be applied to a single pair of opposed side electrodes. Examples of effective quadrupolar axialization via this method include a sevenfold signal-to-noise enhancement derived from 50 remeasurements of a single population of trapped bovine insulin ions and the selective isolation of a single charge state of horse heart myoglobin after an initial measurement that revealed the presence of 14 charge states.  相似文献   

11.
Many biomarker discovery studies are based on matrix-assisted laser desorption/ionisation (MALDI) peptide profiles. In this study, 96 human serum samples were analysed on a Bruker solariX(TM) MALDI Fourier transform ion cyclotron resonance (FTICR) system equipped with a 15 tesla magnet. Isotopically resolved peptides were observed in ultrahigh resolution FTICR profiles up to m/z 6500 with mass measurement errors (MMEs) of previously identified peptides at a sub-ppm level. For comparison with our previous platform for peptide profile mass analysis (i.e. Ultraflex II) the corresponding time-of-flight (TOF) spectra were obtained with isotopically resolved peptides up to m/z 3500. The FTICR and TOF systems performed rather similar with respect to the repeatability of the signal intensities. However, the mass measurement precision improved at least 10-fold in ultrahigh resolution data and thus simplified spectral alignment necessary for robust and quantitatively precise comparisons of profiles in large-scale clinical studies. From each single MALDI-FTICR spectrum an m/z-list was obtained with sub-ppm precision for all different species, which is beneficial for identification purposes and interlaboratory comparisons. Furthermore, the FTICR system allowed new peptide identifications from collision-induced dissociation (CID) spectra using direct infusion of reversed-phase (RP) C(18)-fractionated serum samples on an electrospray ionisation (ESI) source.  相似文献   

12.
The experimental Fourier transform ion cyclotron resonance (FT/ICR) frequency range has been extended to 107 MHz. We report the observation of FT/ICR signals from electron-ionized species of mass-to-charge ratio 8, 7, 6, 5, 4, 3, 2, and 1 μ per elementary charge. We show that moderately high charge states of atomic ions (e.g., N3+) are easily generated and detected. Several applications for high-frequency FT/ICR mass spectrometry are proposed and discussed.  相似文献   

13.
14.
15.
The photodecomposition of imazamox, a herbicide of the imidazolinone family, was investigated in pure water. The main photoproducts from the photolysis were followed over time by liquid chromatography mass spectrometry and structures were proposed from exact mass determinations obtained by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. The method comprised exact mass determination with better than 0.2 ppm mass accuracy and a corresponding structural visualization taking care of respective isotopes with an adapted van Krevelen diagram that enabled a systematic approach to the characterisation of the elementary composition of each photoproduct. By taking advantage of the high resolving power of FT-ICR MS to make precise formula assignments, the derived 2D van Krevelen diagram (O/C; H/C; m/z) enabled one to structurally differentiate the formed photoproducts and to propose a degradation pathway for imazamox. Figure Overview of applied method to analyse the photolysis process of imazamox herbicide  相似文献   

16.
The application of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry to the quantitative study of molecular recognition in the gas phase is reviewed. Because most quantitative measurements are dependent on accurate determination of the pressure of a neutral reagent, methods for accurate pressure measurement in FTICR, including gauge calibration using a reaction with known rate constants (the traditional method), exothermic proton transfer rate measurement (often the best method when accurate neutral pressures in the trapping cell are desired), and linewidth measurement (a little-used, but generally applicable method) are discussed. The use of rate constant measurements in molecular recognition is illustrated with examples employing natural abundance isotopic labeling to study self-exchange and 2 : 1 ligand:metal complex formation kinetics in crown ether-alkali cation systems. Self-exchange rates do not correlate with alkali cation/crown cavity size relationships, whereas 2 : 1 complex formation kinetics correlate strongly with size relationships. The use of exchange equilibrium constant measurements to characterize molecular recognition is illustrated by alkali cation exchanges between 18-crown-6 and the isomers of dicyclohexano-18-crown-6. These experiments show that the alkyl-substituted ligand binds alkali cations better than unsubstituted 18-crown-6 in the gas phase, in accordance with expectations based on the higher polarizability of the alkyl-substituted ligand. Further, the metal binding thermochemistry differs for the two dicyclohexano-18-crown-6 isomers, with the bowl-shaped cis-syn-cis isomer binding all the alkali cations more strongly than the cis-anti-cis isomer. The measurement of entropies and enthalpies associated with one of the most subtle forms of molecular recognition, enantiomeric discrimination, is illustrated by studies of the discrimination between enantiomers of chiral amines by dimethyldiketopyridino-18-crown-6. This chiral ligand binds chiral primary ammonium cations that have the opposite absolute configuration at their stereocenter more strongly than the enantiomer with the same absolute configuration. Gas-phase studies show that this enantiomeric discrimination is enthalpic in origin, likely related to more favorable pi-pi stacking for the preferred enantiomer. Entropy disfavors binding of the preferred enantiomer.  相似文献   

17.
The fragmentations of four strychnos alkaloids have been investigated by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS) in the positive ion mode. Experiments using multi-stage tandem mass spectrometry (ESI-FT-ICR-MSn) allowed us to obtain precise elemental compositions of product ions at high mass resolution. The experimental data demonstrated that the nitrogen bridge and the coordinated oxygen atom on the nitrogen bridge in the alkaloid compounds were the active sites in the MS2 fragmentations. The loss of CH3 or the OCH3 group in those alkaloids, which have an OCH3 substituent, was the dominant fragmentation mode in the MS3 fragmentations. Logical fragmentation schemes for strychnos alkaloids have been proposed and these should be useful for the identification of these compounds.  相似文献   

18.
Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) was coupled with atmospheric pressure photoionization (APPI) for the first time and used for the analysis of several corticosteroids.1 The analytes showed excellent response using APPI when compared with both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). APPI has the advantage of requiring less heat for desolvation, resulting in less thermal degradation of the analytes and higher signal-to-noise than APCI. In terms of ultimate sensitivity, APPI is more efficient than either ESI or APCI for the analysis of corticosteroids. With some compounds, the high-resolution capability of FTICRMS was necessary to obtain an accurate mass due to contributions of the M(+.) (13)C isotope in the [M+H](+) ion peak.  相似文献   

19.
The structure of melittin bound to dodecylphosphocholine (DPC) micelles was investigated using hydrogen–deuterium (H/D) exchange in conjunction with collision induced dissociation (CID) in an rf-only hexapole ion guide with electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR MS). The deuterium incorporation into backbone amide hydrogens of melittin with or without DPC micelles was analyzed at different time points examining the mass of each fragment ion produced by hexapole CID. When melittin existed alone in aqueous solution, more than 80% of amide hydrogens was exchanged within 10 s, and the deuterium content in each fragment ion showed high values throughout the experiments. When melittin was bound to DPC micelles, the percentage of deuterium incorporation into the fragment decreased remarkably at any time point. It increased little by little as the exchange period prolonged, indicating that some stable structure was formed by the interaction with DPC. The results obtained here were consistent with the previous studies on the helical structure of melittin carried out by NMR and CD analyses. The strategy using H/D exchange and MS analysis might be useful for studying structural changes of peptides and proteins caused by phospholipid micelles. It could also be applied to membrane-bound proteins to characterize their structure.  相似文献   

20.
石油是一种复杂体系,研究石油分子组成是分析化学领域的经典难题.近年来,傅里叶变换离子回旋共振质谱技术(Fourier transform ion cyclotron resonance mass spectrometry,FT-ICR MS)的发展,为从分子水平认识石油组成提供了机会,引起了石油化学界的高度关注,并被期待能在石油、石化领域的相关研究中实现重大突破.本文从质谱分辨率和电离技术方面介绍了石油样品的分析需求,总结了近几年基于FT-ICR MS技术对石油分子组成的研究进展,分析了其在应用中存在的关键技术问题及下一步研究方向,并对FT-ICR MS的发展前景给予展望.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号