首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
《Electroanalysis》2004,16(16):1336-1342
The construction, performance characteristics, and application of polymeric membrane (PME) and coated graphite (CGE) thiocyanate‐selective electrodes are reported. The electrodes were prepared by incorporating the complex [Cu(L)](NO3)2 (L=4,7‐bis(3‐aminopropyl)‐1‐thia‐4,7‐diazacyclononane) into a plasiticized poly(vinyl chloride) membrane. The influence of membrane composition, pH of test solution, and foreign ions were investigated. The electrodes reveal Nernstian behavior over a wide SCN? ion concentration range (1.0×10?6–1.0×10?1 M for PME and 5.0×10?7–1.0×10?2 M for CGE) and show fast dynamic response times of 15 s and lower. The proposed sensors show high selectivity towards thiocyanate over several common organic and inorganic anions. They were successfully applied to the direct determination of thiocyanate in urine and saliva of smokers and nonsmokers, and as an indicator electrode in titration of Ag+ ions with thiocyanate.  相似文献   

2.
《Electroanalysis》2005,17(9):776-782
Three recently synthesized Schiff's bases were studied to characterize their ability as Cr3+ ion carrier in PVC‐membrane electrodes. The polymeric membrane (PME) and coated glassy carbon (CGCE) electrodes based on 2‐hydroxybenzaldehyde‐O,O′‐(1,2‐dioxetane‐1,2‐diyl) oxime (L1) exhibited Nernstian responses for Cr3+ ion over wide concentration ranges (1.5×10?6–8.0×10?3 M for PME and 4.0×10?7–3.0×10?3 M for CGCE) and very low limits of detection (1.0×10?6 M for PME and 2.0×10?7 M for CGCE). The proposed potentiometric sensors manifest advantages of relatively fast response and, most importantly, good selectivities relative to a wide variety of other cations. The selectivity behavior of the proposed Cr3+ ion‐selective electrodes revealed a considerable improvement compared to the best previously PVC‐membrane electrodes for chromium(III) ion. The potentiometric responses of the electrodes are independent of pH of the test solution in the pH range 3.0–6.0. The electrodes were successfully applied to determine chromium(III) in water samples.  相似文献   

3.
《Electroanalysis》2005,17(17):1534-1539
The construction, performance, and applications of a novel ytterbium(III) sensor based on N‐(2‐pyridyl)‐N′‐(2‐methoxyphenyl)‐thiourea (PMT), as an excellent carrier, in plasticized poly(vinyl chloride) PVC matrix, is described. The influences of membrane composition and pH on the potentiometric response of the sensor were investigated. The sensor exhibits a nice Nernstian response for Yb(III) ion over a wide concentration range of 4 decades of concentration (1.0×10?6–1.0×10?2 M), and a detection limit of 5.0×10?7 M. The response time of the electrodes is between 8 and 10 s, depending on the concentration of ytterbium(III) ions. The proposed sensor can be used for about 8 weeks without any considerable divergence in potential. The sensor revealed very good selectivity for Yb(III) in the presence of several metal ions. The best performance was observed for the membrane containing; 30% PVC, 59% o‐nitrophenyloctyl ether (NPOE) as solvent mediator, 7% PMT, and 4% sodium tetraphenyl borate (NaTPB). It was successfully applied as indicator electrodes in the potentiometric titration of Yb(III) with EDTA and for the determination of fluoride ion in two mouth wash formulations. The proposed La(III) sensor was found to work well under laboratory conditions. It was also used as an indicator electrode in titration of a 1.0×10?4 M of Yb(III) with a standard EDTA solution (1.0×10?2 M). It was also used for determination of Yb(III) ion in Xenotime .  相似文献   

4.
The simple PVC‐based membrane containing N,N′,N″,N′′′‐tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane (tpmc) as an ionophore and dibutyl phthalate as a plasticizer, directly coated on a glassy carbon electrode was examined as a new sensor for Cu2+ ions. The potential response was linear within the concentration range of 1.0×10?1–1.0×10?6 M with a Nernstian slope of 28.8 mV/decade and detection limit of 7.0×10?7 M. The electrode was used in aqueous solutions over a wide pH range (1.3–6). The sensor exhibited excellent selectivity for Cu2+ ion over a number of cations and was successfully used in its determination in real samples.  相似文献   

5.
《Electroanalysis》2004,16(4):282-288
Five recently synthesized macrocyclic diamides were investigated to characterize their ability as beryllium ion carriers in potentiometric PVC‐membrane electrodes. The electrodes based on 1,15‐diaza‐3,4;12,13‐dibenzo‐5,8,11‐trioxabicyclo[13,2,2] heptadecane‐2,14‐dione exhibited a Nernstian response for Be2+ ion over wide concentration ranges (from 3.0×10?6 to 3.0×10?2 M for polymeric membrane electrode, PME, and from 5.0×10?7 to 2.0×10?2 M for coated glassy carbon electrode, CGCE) and very low detection limits (2.0 ×10?6 M for PME and 4.0×10?7 M for (CGCE). The electrodes possess low resistances, fast responses, satisfactory reproducibilities and, most importantly, good selectivities relative to a variety of other common cations. The potentiometric response of the electrodes is independent of pH of test solution in the pH range of 4.0–7.5. The proposed sensors were used to determine beryllium ion in water samples.  相似文献   

6.
A PVC membrane electrode for copper(II) ion based on a recently synthesized Schiff base as a suitable ion carrier was constructed. The electrode exhibits a Nernstian slope of 28.3 ± 0.6 mV per decade of Cu2+ over a wide concentration range of 7.0 × 10?6‐2.6 × 10?2 M with a detection limit of 5.0 × 10?6M in the pH range of 4.2–5.8. The response time is about 10s and it can be used for at least 1 month without any considerable divergence in potential. It was successfully applied as an indicator electrode in the potentiometric titration of copper ions.  相似文献   

7.
《Electroanalysis》2005,17(20):1828-1834
A recently synthesized azao‐containing Schiff's base N,N′‐adipylbis(5‐phenylazo salicylaldehyde hydrazone) was used as a suitable neutral ion carrier in construction of a highly selective La3+‐PVC membrane electrode. The electrode exhibits a Nernstian response with a slope of 19.4 mV decade?1 over a wide concentration range (1.0×10?6–1.0×10?2 M) and a limit of detection of 4.0×10?7 M (0.05 ppm). The electrode possesses a fast response time of ca. 10 s and can be used for at least 3 months without observing any deviation. The proposed electrode revealed excellent selectivity for La3+ over a wide variety of alkali, alkaline earth, transition and heavy metal ions and could be used in a pH range of 4.0–8.0. The practical utility of the electrode has been demonstrated by its use as an indicator electrode in the potentiometric titration of La3+ ions with EDTA and in determination of F? ion in some pharmaceutical preparations.  相似文献   

8.
《Electroanalysis》2002,14(24):1691-1698
Three different recently synthesized aza‐thioether crowns containing a 1,10‐phenanthroline sub‐unit (L1–L3) and a corresponding acyclic ligand (L4) were studied to characterize their abilities as silver ion ionophores in PVC‐membrane electrodes. Novel conventional silver‐selective electrodes with internal reference solution (CONISE) and coated graphite‐solid contact electrodes (SCISE) were prepared based on one of the 15‐membered crowns containing two donating S atoms and two phenanthroline‐N atoms (L1). The electrodes reveal a Nernstian behavior over wide Ag+ ion concentration ranges (1.0×10?5?1.0×10?1 M for CONISE and 5.0×10?8?4.0×10?2 M for SCISE) and very low limits of detection (8.0×10?6 M for CONISE and 3.0×10?8 M for SCISE). The potentiometric response is independent from pH of the solution in the pH range 3.0–8.0. The electrodes manifest advantages of low resistance, very fast response and, most importantly, good selectivities relative to a wide variety of other cations. The electrodes can be used for at least 2 months (for CONISE) and 4 months for (SCISE) without any appreciable divergence in potentials. The electrodes were used as an indicator electrode in the potentiometric titration of Ag+ ion and in the determination of silver in photographic emulsions and in radiographic and photographic films.  相似文献   

9.
《Electroanalysis》2006,18(16):1620-1626
A polyvinylchloride membrane sensor based on N,N′‐bis(salecylidene)‐1,2‐phenylenediamine (salophen) as membrane carrier was prepared and investigated as a Al3+‐selective electrode. The sensor exhibits a Nernstian response toward Al(III) over a wide concentration range (8.0×10?7–3.0×10?2 M), with a detection limit of 6.0×10?7 M. The potentiometric response of the sensor is independent of the pH of the test solution in the pH range 3.2–4.5. The electrode possesses advantages of very fast response and high selectivity for Al3+ in comparison with alkali, alkaline earth and some heavy metal ions. The sensor was used as an indicator electrode, in the potentiometric titration of aluminum ion and in determination of Al3+ contents in drug, water and waste water samples.  相似文献   

10.
A new solvent polymeric membrane (PME) and coated graphite (CGE) electrodes based on 3-amino-2-mercapto-3H-quinazolin-4-one as a suitable carrier for La(III) ion are described. The sensors exhibited a Nernstian response for La(III) ion over a wide concentration range (3.0 × 10?7 to 1.0 × 10?1 M for PME and 1.0 × 10?7 to 1.0 × 10?1 M for CGE) with a slope of 20.1 ± 0.3 (PME) and 23.4 ± 0.4 (CGE) mV decade?1. The lower detection limits by PME and CGE were 2.0 × 10?7 and 7.1 × 10?8 M, respectively. The potentiometric response of the proposed electrodes was independent of the pH of the test solution in the pH range 3.0–9.0 with a fast response time (<10 s). The applications of prepared sensors were demonstrated in the determination of lanthanum ions in spiked water sample and also utilized for indirect determination of fluoride content of two mouth wash preparation samples.  相似文献   

11.
A ruthenium(II) complex [Ru(PPh3)2(pytsc)2] {Hpytsc = pyridine‐2‐carbaldehydethiosemicarbazone, (C5H5N)C2(H)=N3‐N2(H)‐C1(=S)N1H} has been used as an ion carrier for the selective determination of silver(I) ions in solution. Silver(I) ion‐selective coated graphite based (CGE) and PVC polymeric membrane based (PME) electrodes exhibit Nernstian slope for silver(I) ions over a wide concentration range from 1.0 × 10−1 M to 5.0 × 10−6 M (with CGE) and 1.0 × 10−1 M to 2.0 × 10−5 M (with PME). The working pH range of these electrodes has been found to be from 1.2 to 7.2 for CGE and 2.2 to 6.5 for PME. The proposed CGE sensor exhibits better analytical features like sensitivity and selectivity towards different secondary ions in comparison to the corresponding PME with no interference from mercury(II) ions . These electrodes also act as indicator electrodes in potentiometric titration and have been successfully used for the determination of silver content in solution of real samples (1 gm dissolved in 100 mL of dilute nitric acid) such as silver ornaments and thin silver foils. Silver content determined by the use of ion selective electrode was found to vary in the concentration range from 1.20 x 10−2 M to 7.45 x 10−2 M and results were found to be comparable with those obtained from the traditional volumetric method of analysis. It is the first report of a metal‐ligand complex used as an ion carrier in ion selective electrode, which is selective for a metal ion other than the one used in the complex.  相似文献   

12.
The potentiometric characteristics of a new Cu2+‐selective electrode based on 2‐(benzyliminomethyl)‐6‐methoxy‐4‐(4‐methoxyphenyl‐azo) phenol as an efficient ionophore has been evaluated. The effects of influential parameters on the potentiometric responses such as the amount of plasticizer, the amount of ionophore, pH of the sample solution, and the effect of coexisting ions on the electrode signal were subsequently investigated . The selectivity of the electrode was assessed by calculating the selectivity coefficients using the matched potential method. The optimum ratio of the amount of materials required for the preparation of the electrode was found to be 1.7: 32.1: 64.2: 2.0 corresponding to carboxylated PVC, dimethyl sebacate as solvent mediators, potassium tetrakis (p‐chlorophenyl) borate as the anion localizing agent, and ionophore, respectively. The electrode had a fast response (7s) as well as a satisfactory Nernstian slope (29.26±0.91 mV/decade) to Cu2+ over a wide concentration range of 2.0×10?6‐ 5.0×10?2 M with a low detection limit of 5.9×10?7 M. The developed sensor was successfully used for the potentiometric titration of Cu2+ ion with EDTA and subsequently, efficient determination of this metal ion in a mineral water sample was performed.  相似文献   

13.
Novel polymeric membrane electrode (PME) and coated graphite electrode (CGE) for nickel ion were prepared based on 2,9-(2-methoxyaniline)2-4,11-Me2-[14]-1,4,8,11-tetraene-1,5,8,12-N4 as a suitable neutral ionophore. The addition of lipophilic anion excluder (NaTPB) and various plasticizers viz o-nitrophenyloctylether (o-NPOE), dioctylphthalate (DOP), dibutylphthalate (DBP), 1-chloronaphthalene (CN) and tri-n-butylphosphate (TBP) have found to improve the performance of the sensors. The best performance was obtained for the membrane sensor having a composition of I:NaTPB:TBP:PVC in the ratio 6:4:100:90 (w/w; mg). The electrodes exhibit Nernstian slopes for Ni2+ ions over wide concentration ranges of 4.6 × 10?7–1.0 × 10?1 M for PME and 7.7 × 10?8–1.0 × 10?1 M for CGE with limits of detection of 2.7 × 10?7 M for PME and 3.7 × 10?8 M for CGE. The response time for PME and CGE was found to be 10 and 8 s respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.0–8.0. The proposed electrodes revealed good selectivities over a wide variety of other cations including alkali, alkaline earth, transition and heavy metal ions. The coated graphite electrode was used as an indicator electrode in the potentiometric titration of nickel ion with EDTA and in direct determination in different fruit juices and wine samples.  相似文献   

14.
《Electroanalysis》2005,17(24):2260-2265
A new Cu(II) ion‐selective PVC membrane sensor based on 6‐methyl‐4‐(1‐phenylmethylidene)amino‐3‐thioxo‐1,2,4‐triazin‐5‐one (MATTO) as an excellent sensing material was developed. The electrode exhibits a Nernstian slope of 29.2±0.4 mV per decade over a very wide concentration range between 1.0×10?1 and 1.0×10?6 M, with a detection limit of 4.8×10?7 M (30.5 ng/mL). The sensor possesses the advantages of short conditioning time, fast response time (<10 s), and especially, very good selectivity towards transition and heavy metal, and some mono, di and trivalent cations. The proposed electrode was successfully applied to the determination of copper in wastewater of copper electroplating samples and as an indicator electrode in potentiometric titration of Cu(II) ions with EDTA.  相似文献   

15.
Poly(vinyl chloride)‐based membranes of salen ligands, 2‐((E)‐((1R,2S)‐2‐((E)‐5‐tert‐butyl‐2‐hydroxybenzylideneamino)cyclohexylimino)methyl)‐4‐tert‐butyl phenol (S1) and 2‐((E)‐((1R,2S)‐2‐((E)‐3,5‐di‐tert‐butyl‐2‐hydroxybenzylideneamino)cyclohexylimino)methyl)‐4,6‐di‐tert‐butylphenol (S2) were fabricated and explored as cobalt(II) selective electrodes. The performance of the polymeric membrane electrode (PME) and coated graphite electrode (CGE) were compared and it was observed that CGE showed a wide working concentration range of 1.1×10?8 to 1.0×10?1 mol L?1 with a limit of detection of 7.0×10?9 mol L?1 exhibiting the Nernstian slope 29.6 mV/decade of activity in the pH range 3.0–9.0. It was used for the determination of cobalt(II) ions in water, soil, beer, pharmaceutical samples and medicinal plants and would be used as an indicator electrode in potentiometric titration with EDTA.  相似文献   

16.
《Electroanalysis》2006,18(10):1019-1027
A new PVC membrane potentiometric sensor for Ag(I) ion based on a recently synthesized calix[4]arene compound of 5,11,17,23‐tetra‐tert‐butyl‐25,27‐dihydroxy‐calix[4]arene‐thiacrown‐4 is developed. The electrode exhibits a Nernstian response for Ag(I) ions over a wide concentration range (1.0×10?2?1.0×10?6 M) with a slope of 53.8±1.6 mV per decade. It has a relatively fast response time (5–10 s) and can be used for at least 2 months without any considerable divergence in potentials. The proposed electrode shows high selectivity towards Ag+ ions over Pb2+, Cd2+, Co2+, Zn2+, Cu2+, Ni2+, Sr2+, Mg2+, Ca2+, Li+, K+, Na+, NH4+ ions and can be used in a pH range of 2–6. Only interference of Hg2+ is found. It is successfully used as an indicator electrode in potentiometric titration of a mixture of chloride, bromide and iodide ions.  相似文献   

17.
《Electroanalysis》2004,16(12):1002-1008
Preliminary theoretical studies revealed the selective complexation of bis (2‐mercaptoanil) diacetyl (BMDA) with La3+ over several alkali, alkaline earth and heavy metal ions. Thus, novel PVC‐based membrane (PBM) and coated graphite membrane (CGM) sensors for La(III) based on BMDA were prepared. The electrodes display Nernstian behavior over wide concentration ranges (i.e., 1.0×10?5–1.0×10?1 M for PBM and 1.0×10?6–1.0×10?1 M for CGM). The potential response of sensors was pH independent in the range of 4.0–8.0. The sensors possess satisfactory reproducibility, fast response time (<15 s), and specially excellent discriminating ability for La3+ ions with respect to most of the cations. The membrane sensor was used as an indicator electrode in potentiometric titration of lanthanum ions with EDTA. The coated graphite membrane electrode was applied in determination of fluoride ions in mouth wash preparations.  相似文献   

18.
Vitamin B1‐selective electrodes with PVC membrane were developed that contain ion associates of vitamin B1 with an inorganic anion, BiI4?, and an organic anion, brilliant yellow, as electrode‐active substances. The linearity ranges of the electrode function are 1.0×10?5–1.0×10?2 and 1.0×10?4–1.0×10?2 M, the electrode function slopes are 33.0±1.0 and 33.1±1.1 mV decade?1, the detection limits are 5.5×10?6 and 8.3×10?5 M for BiI4? and brilliant yellow respectively. The working range of pH is 5–12. The efficiency of the use of electrodes for the vitamin B1 content control in multivitamin pharmaceutical preparations was shown by direct potentiometry and potentiometric titration methods.  相似文献   

19.
A novel thia-aza substituted macrocyclic diamide 7,10,13-triaza-1-thia-4,16-dioxa-20,24-dimethyl-2,3;17,18-dibenzo-cyclooctadecane-6,14-dione (L) was synthesized and stability of its complexes with several alkaline earth, transition and heavy metal ions were studied conductometrically in methanol solution. The resulting 1:1 Ag+L complex found to be the most stable one among all cation complexes studied. The optimized structures of the ligand and its Ag+ complex were also investigated. Based on the preliminary results thus obtained, L was used as an excellent sensing material to prepare polymeric membrane (PME) and coated graphite (CGE) silver-selective electrodes. The electrodes revealed a Nernstian behavior over wide Ag+ ion concentration ranges (i.e., 2.0 × 10?6–1.0 × 10?2 M for PME and 5.0 × 10?7–1.0 × 10?2 M for CGE). The potentiometric responses were independent of pH of the test solution in the range 2.9–6.8. The electrodes possessed advantages of low resistance, relatively fast response time, long lifetimes and, especially, good selectivity relative to a wide variety of other cations. The electrodes were used, as indicator electrodes, in the potentiometric titration of silver ion and in the determination of Ag+ ion in waste water, photographic emulsion, radiographic and photographic films and dental amalgams.  相似文献   

20.
Two new highly selective triiodide electrodes have been prepared using charge‐transfer complex of iodine with cryptand 222 as an electroactive ionophore and nitrophenyl octyl ether as a plasticizing agent. The electrodes showed Nernstian response to triiodide ions over a concentration range from 1.0 × 10?;2 — 7.9 × 10?;7 M and from 1.0 × 10?;2 — 1 × 10?;6 M with detection limits of 6.3 × 10?;7 and 7.9 × 10?;7 M for cryptand and its charge‐transfer complex with iodine, respectively. The response times (t95%) of the sensors were 10 and 5 s. The membrane could be used for more than 1 month without any divergence in potentials. The proposed sensors exhibited very high selectivity for triiodide ion over other anions, and could be used in a wide pH range ?2–10. These electrodes were successfully applied as an indicator electrode in potentiometric titration of copper in ore samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号