首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Electroanalysis》2017,29(2):497-505
An electrochemical sensor for the simultaneous and sensitive detection of Cd(II) and Pb(II) is proposed on the basis of square‐wave anodic stripping voltammetry (SWASV) experiments using a novel bismuth film/ordered mesoporous carbon‐molecular wire modified graphite carbon paste electrode (Bi/OMC‐MW/GCPE). Ordered mesoporous carbon (OMC) and molecular wire (MW) (diphenylacetylene) were used as the modifier and binder, respectively. The Bi/OMC‐MW/GCPE was prepared with the addition of graphite powder, OMC and DPA at the ratio of 2 : 1 : 1. The electrochemical properties and morphology of the electrode were characterized by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), SWASV and scanning electron microscopy (SEM). The parameters affecting the stripping current response were investigated and optimized. The experimental results show that the prepared electrode exhibited excellent electrochemical performance, good electrical conductivity and a high stripping voltammetric response. Under optimized conditions, a linear range was achieved over a concentration range from 1.0 to 70.0 μg/L for both Cd(II) and Pb(II) metal ions, with detection limits of 0.07 μg/L for Cd(II) and 0.08 μg/L for Pb(II) (S/N=3) with the deposition time 150 s. Moreover, the sensor exhibited improved sensitivity and reproducibility compared to traditional CPEs. The fabricated electrode was then successfully used to satisfactorily detect Cd(II) and Pb(II) in real soil samples.  相似文献   

2.
The antimony film electrode (SbFE) was prepared ex situ for anodic and adsorptive stripping voltammetric measurement of selected heavy metal ions. The electrode revealed good linearity for Cd(II) and Pb(II) in a nondeaerated solution of 0.01 M HCl in the examined concentration range from 25 to 80 μg L?1 with limits of detection of 1.1 μg L?1 for Cd(II) and 0.3 μg L?1 for Pb(II) and an excellent reproducibility. The preplated SbFE was also preliminary tested for measuring low levels of Ni(II) using adsorptive stripping voltammetry exhibiting good linearity and sensitivity in combination with only a 30 s deposition step.  相似文献   

3.
This paper describes a comparative study of the simultaneous determination of Cd(II), Pb(II), Tl(I), and Cu(II) in highly saline samples (seawater, hydrothermal fluids, and dialysis concentrates) by ASV using the mercury‐film electrode (MFE) and the bismuth‐film electrode (BiFE) as working electrodes. The features of MFE and BiFE as working electrodes for the single‐run ASV determinations are shown and their performances are compared with that of HMDE under similar conditions. It was observed that the stripping peak of Tl(I) was well separated from Cd(II) and Pb(II) peaks in all the studied saline samples when MFE was used. Because of the severe overlapping of Bi(III) and Cu(II) stripping peaks in the ASV using BiFE, as well as the overlapping of Pb(II) and Tl(I) stripping peaks in the ASV using HMDE, the simultaneous determination of these metals was not possible in highly saline medium using these both working electrodes. The detection limits calculated for the metals using MFE and BiFE (deposition time of 60 s) were between 0.043 and 0.070 μg L?1 for Cd(II), between 0.060 and 0.10 μg L?1 for Pb(II) and between 0.70 and 8.12 μg L?1 for Tl(I) in the saline samples studied. The detection limits calculated for Cu(II) using the MFE were 0.15 and 0.50 μg L?1 in seawater/hydrothermal fluid and dialysis concentrate samples, respectively. The methods were applied to the simultaneous determination of Cd(II), Pb(II), Tl(I), and Cu(II) in samples of seawater, hydrothermal fluids and dialysis concentrates.  相似文献   

4.
Multiwall carbon nanotubes were dispersed in Nafion (MWCNTs‐NA) solution and used in combination with bismuth (MWCNTs‐NA/Bi) for fabricating composite sensors to determine trace Pb(II) and Cd(II) by differential pulse anodic stripping voltammetry (DPASV). The electrochemical properties of the MWCNTs‐NA/Bi composites film modified glassy carbon electrode (GCE) were evaluated. The synergistic effect of MWCNTs and bismuth composite film was obtained for Pb(II) and Cd(II) detection with improved sensitivity and reproducibility. Linear calibration curves ranged from 0.05 to 100 μg/L for Pb(II) and 0.08 to 100 μg/L for Cd(II). The determination limits (S/N=3) were 25 ng/L for Pb and 40 ng/L for Cd, which compared favorably with previously reported methods in the area of electrochemical Pb(II) and Cd(II) detection. The MWCNTs‐NA/Bi composite film electrodes were successfully applied to determine Pb(II) and Cd(II) in real sample, and the results of the present method agreed well with those of atomic absorption spectroscopy.  相似文献   

5.
An antimony film electrode (SbFE) was prepared in situ on a glassy carbon support and in a new supporting electrolyte, a saturated solution of hydrogen potassium tartrate in which Sb(III) ions were complexed using tartrate. Its performance in anodic stripping voltammetric (ASV) determination of Cd(II), Pb(II), Zn(II), Tl(I), In(III) and Cu(II) traces was examined. It was found that 1.2 mg/L of Sb(III) yields the finest quality SbFE for analytical purposes. The procedure with in situ SbFE ensures well‐defined anodic stripping voltammetric curves of the investigated elements, low detection limits (0.5–3.8 µg/L), good reproducibility (1–5 %) and satisfactory sensitivity (32–184 nA/(µg/L)).  相似文献   

6.
《Analytical letters》2012,45(2):283-302
Abstract

A method is described for the reliable determination of copper, lead, cadmium and zinc in natural waters by anodic stripping potentiometry with the use of a novel combined electrode. The method involves two stripping cycles during which copper is initially determined on its own, followed by simultaneous determination of lead, cadmium and zinc after addition of gallium (III) ions. The optimum conditions include 0.01 M HCl as supporting electrolyte, 10 mg/L Hg (II) as chemical oxidant; Edep(Cu) -700 mV vs Ag/AgCl; Edep(Pb,Cd,Zn) -1200 mV vs Ag/AgCl; tdep 10s; 150 μg/L Ga (III); sample rotation rate 5 and rest period 30s. Under these conditions, as low as 0.06 μg/L Cu (0.7% RSD); 0.2 μg/L Pb (13% RSD); 0.04 μg/L Cd (7.8% RSD) and 0.06 μg/L Zn (5.5% RSD) can be determined reliably. A linear concentration range of 0–110 μg/L was obtained for the four metals. The successful application of the method to reference fresh water, creek water and tap water is demonstrated.  相似文献   

7.
以铋膜修饰玻碳电极为工作电极,采用阳极溶出伏安法对微量Pb(Ⅱ)进行测定。考察了铋离子浓度、支持电解质pH、沉积时间等因素对测定的影响。实验结果表明,铋膜修饰电极对痕量Pb(Ⅱ)具有良好的电化学响应。在实验选定条件下,Pb(Ⅱ)在10~260!g/L范围内与峰电流呈良好的线性关系,检出限为1.98!g/L。用同一支铋膜电极对50!g/L Pb(Ⅱ)平行测定10次,相对标准偏差(RSD)为2.82%。该电极可应用于井水中铅的测定。  相似文献   

8.
An in-situ antimony film screen-printed carbon electrode (in-situ SbSPCE) was successfully used for the determination of Cu(II) simultaneously with Cd(II) and Pb(II) ions, by means of differential pulse anodic stripping voltammetry (DPASV), in a certified reference groundwater sample with a very high reproducibility and good trueness. This electrode is proposed as a valuable alternative to in-situ bismuth film electrodes, since no competition between the electrodeposited copper and antimony for surface sites was noticed. In-situ SbSPCE was microscopically characterized and experimental parameters such as deposition potential, accumulation time and pH were optimized. The best voltammetric response for the simultaneous determination of Cd(II), Pb(II) and Cu(II) ions was achieved when deposition potential was −1.2 V, accumulation time 120 s and pH 4.5. The detection and quantification limits at levels of μg L−1 suggest that the in-situ SbSPCE could be fully suitable for the determination of Cd(II), Pb(II) and Cu(II) ions in natural samples.  相似文献   

9.
Trace analysis of thallium at surface modified thick-film graphite electrode with Bi nanopowder has been carried out using square-wave anodic stripping voltammetry (SWASV) technique. The Bi nanopowder electrode exhibited a well-defined response relating to the oxidation of Tl. From the linear relationship between Tl concentration and peak current, the sensitivity of the Bi nanopowder electrode was quantitatively estimated. The detection limit of Tl was determined to be 0.03 μg/L for 1.0 μg/L Tl solution under 10 min accumulation, which is lower than the reported values for a Bi film electrode. Furthermore, it is confirmed that EDTA addition effectively eliminates the Pb and Cd interferences in the course of Tl determination by forming complexes with Pb2+ and Cd2+.  相似文献   

10.
《Electroanalysis》2006,18(2):177-185
In this article, the results of some recent investigations on two types of bismuth‐modified carbon paste electrodes are presented. In the first study, the bismuth‐film carbon paste electrode (BiF‐CPE) operated in situ and employed in anodic stripping voltammetry of Cd(II) and Pb(II) at the low μg L?1 level was of interest in view of choosing the proper Bi(III)‐to‐Me(II) concentration ratios (where Me: Pb or Cd). Such optimization has resulted in significant improvement of detection limits down to 1.0 μg L?1 Cd and 0.8 μg L?1 for Pb, which allowed us to apply the BiF‐CPE for analysis of selected real samples of tap and sea water. The BiF‐CPE was also further investigated for its application in highly alkaline media. In this case, attention was focused on the complex‐forming capabilities of the OH ions and their effect on the anodic stripping characteristics of some heavy metals (i.e. Cd, Pb, Tl) as well as upon the formation of the bismuth film itself. The last example deals with the continuing characterization of the recently introduced carbon paste electrodes modified with bismuth powder (Bi‐CPEs) which combine the advantageous properties of carbon paste material with the favorable electrochemical properties of bismuth. Three series of electrodes, differing either in the content of metallic bismuth (from 8 to 50% w/w) or in the type of the carbon powder used (two spectroscopic types of graphite and powdered glassy carbon), were compared and the respective relations to the optimal carbon paste composition evaluated. Attractive electroanalytical performance of the Bi‐CPE in anodic stripping voltammetry is demonstrated for selected model mixtures of heavy metals (Mn, Zn, Cd, Pb, Tl, and In).  相似文献   

11.
Platinum nanoflowers modified glassy carbon electrodes (PtNFs/GCE) was fabricated simply for lead determination in water samples. The modified electrodes were prepared by electrodeposition in hexachloroplatinic acid solution at constant potential. The influence of deposition time and potential on surface morphology, chemical composition, electrochemical properties of electrode were investigated. At ?0.2 V of potential and 150 s of deposition duration, platinum developed as nanoflower shape and scattered densely all over the glassy carbon surface, producing the largest electrochemically active surface areas. The highest differential pulse stripping voltammetry (DPSV) signal of lead was obtained by using the prepared electrode. Under optimized experimental condition of electrolyte, accumulation potential and time, the peak current was found to be linear proportion to lead concentration in range of 1 to 100 μg L?1 (slope=0.371) with a limit of detection of 0.398 μg L?1. The method has good repeatability and reproducibility with relative standard deviations of 1.47 % and 4.83 %, respectively. The modified PtNFs/GCE also demonstrated an excellent long‐term stability with only 9 % decrease in Pb peak current over 30 days. Moreover, the performance of the modified PtNFs/GCE in determination of Pb(II) in two industrial wastewaters was good agreement with data obtained by a graphite furnace atomic absorption spectrometry (GFAAS) method.  相似文献   

12.
The simultaneous “in natura” determination of trace Zn, Pb and Cu in whisky samples by anodic stripping voltammetry (ASV), using a hanging mercury drop electrode, without previous treatment or addition of supporting electrolyte is described. The choice of an appropriate stripping voltammetric method and deposition potential minimizes the influence of the organic content and ensures a good reproducibility of the measurements. The reliability of the method was tested comparing the results with those of atomic absorption spectroscopy (AAS), with differences of about 10%. The method allows the determination of heavy metal ions in the μg L–1 range.  相似文献   

13.
The preparation of Hg(II)-modified multi walled carbon nanotube (MWCNT) by reaction of oxidized MWCNT with aqueous HgCl2 was carried out. The Hg(II)-modified multi walled carbon nanotube (Hg(II)/MWCNT) dispersed in Nafion solution was used to coat the polished graphite electrode surface. The Hg(II)/MWCNT modified graphite electrode was held at a cathodic potential (−1.0 V) to reduce the coordinated Hg(II) to Hg forming nanodroplets of Hg. The modified electrode was characterized by FESEM/EDAX which provided useful insights on the morphology of the electrode. The SEM images showed droplets of Hg in the size of around 260 nm uniformly distributed on the MWCNT. Differential pulse anodic stripping voltammetry (DPASV) and electrochemical impedance spectroscopy were used to study the Hg(II) binding with MWCNT. Differential pulse anodic stripping voltammetry of ppb levels of cadmium and lead using the modified electrode yielded well-defined peaks with low background current under a short deposition time. Detection limit of 0.94 and 1.8 ng L−1 were obtained following a 3 min deposition for Pb(II) and Cd(II), respectively. Various experimental parameters were characterized and optimized. High reproducibility was observed from the RSD values for 20 repetitive measurements of Pb(II) and Cd(II) (1.7 and 1.9%, respectively). The determination of Pb(II) and Cd(II) in tap water and Pb(II) in human hair samples was carried out. The above method of fabrication of Hg(II)/MWCNT modified graphite electrode clearly suggests a safe route for preparing Hg immobilized electrode for stripping analysis.  相似文献   

14.
重金属铅和镉元素在环境中普遍存在并可长期蓄积,是不可降解的环境污染物,常危害人体健康.建立快速准确的测定方法具有实际意义[1].  相似文献   

15.
A simple electroanalytical method for Cd(II) and Pb(II) detection based on differential pulse anodic stripping voltammetry (DPSV) with in situ prepared antimony-modified glassy carbon rotating disk electrode (in situ Sb-GC-RDE) was developed. The electrochemical detection was performed in a microdroplet (50 μL) of 0.01 M hydrochloric acid that is placed between the electrode surface (top) and a Parafilm®-covered glass slide to maintain a hydrophobic surface (bottom). This method includes a preconcentration process using a membrane filter (MF). The target metal ions were complexed with 1-(2-pyridylazo)-2-naphthol (PAN) as a chelating agent, which was accumulated on the MF via filtration. The RDE microdroplet anodic stripping voltammetry was suitable for the elution and determination of metal ions accumulated on the MF. The in situ preparation of antimony-modified electrode allows the use of common GC electrode with high performance. The detection limits for Cd(II) and Pb(II) were 1.4 and 1.1 μg/L, respectively. The proposed method was successfully used in natural water samples for the simultaneous determination of Cd(II) and Pb(II).  相似文献   

16.
研究了金-钯双金属纳米颗粒修饰电极测定痕量砷的阳极溶出伏安法。采用紫外可见分光光度法、高分辨透射电镜及循环伏安法对颗粒的结构和电化学特性进行表征。采用方波伏安法测定三价砷,探讨了富集电位和方波伏安参数如频率、增幅、波幅以及干扰离子等对测定结果的影响。实验结果表明:金-钯双金属纳米颗粒呈壳-核结构;砷在0.30 V出现灵敏的阳极溶出伏安峰,峰电流与砷质量浓度在0.5~20μg/L范围内呈良好的线性关系,检出限为0.15μg/L;所制备的修饰电极重现性好,可用于三价砷的重复测定。共存离子Cu(Ⅱ)会影响三价砷的测定,而Pb(Ⅱ)、Cd(Ⅱ)、Zn(Ⅱ)等离子的存在对测定结果无影响。  相似文献   

17.
采用循环伏安法以镍铬合金为基体构建了铋膜/镍铬合金电极,以扫描电镜表征其表面形貌,利用线性扫描伏安法研究了Pb(II)、Cd(II)在该电极上电化学行为。结果表明:在0.20 mol/L HAc-NaAc缓冲溶液(pH4.5)中,该电极对Pb(II)、Cd(II)离子有较好的电催化活性,Pb(II)、Cd(II)的阳极溶出峰电流与其浓度分别呈良好的线性关系,检出限分别为6.39μg/L和3.52μg/L。  相似文献   

18.
Three different commercial carbon nanomaterial-modified screen-printed electrodes based on graphene, carbon nanotubes and carbon nanofibers were pioneeringly tested as electrode platforms for the plating with Sb film. They were microscopically and analytically compared to each other and to the most conventional unmodified carbon screen-printed electrode (SPCE). The obtained detection and quantification limits suggest that the in-situ antimony film electrode prepared from carbon nanofibers modified screen-printed electrode (SbSPCE-CNF) produces a better analytical performance as compared to the classical SPCE modified with antimony for Pb(II) and Cd(II) determination, approving its appropriateness for measuring low μg L−1 levels of the considered metals. In-situ SbSPCE-CNF was successfully used for the simultaneous determination of Pb(II) and Cd(II) ions, by means of differential pulse anodic stripping voltammetry, in a certified reference estuarine water sample with a very high reproducibility and good trueness.  相似文献   

19.
Bismuth film modified and chemically activated carbon micro‐thread electrodes were investigated for the simultaneous determination of Cd(II) and Pb(II) using square wave anodic stripping voltammetry. The carbon thread electrode was characterised using both surface and electrochemical techniques. Electrochemical impedance spectroscopy (EIS) studies demonstrated that the H2SO4/IPA‐treated carbon thread electrode showed a much improved resistance response (Rct=23 Ω) compared to the IPA‐untreated carbon thread (Rct=8317 Ω). Furthermore, parameters such as the effect of deposition potential, deposition time and Bi(III) concentration were explored using square wave voltammetry. Detection limits (S/N=3) for Cd(II) and Pb(II) were found to be 1.08 µg L?1 and 0.87 µg L?1, respectively and response was found to be linear over the range 5–110 µg L?1. The proposed Bi/IPA‐treated carbon thread electrode exhibited a high selectivity towards Cd(II) and Pb(II) even in the presence of a range of heavy metals and is capable of repetitive and reproducible measurements, being attributed to the high surface area, geometry and electrode treatment characteristics. The proposed metal ion sensor was employed to determine cadmium and lead in river water samples and % RSD was found to be 5.46 % and 5.93 % for Cd(II) and Pb(II) respectively (n=3). Such facile sensing components favour the development of cost effective portable devices for environmental sample analysis and electrochemical applications.  相似文献   

20.
This work reports the trace determination of Tl(I) by square‐wave anodic stripping voltammetry (SWASV) on novel microsensors equipped with a bismuth‐film electrode (BiFE). The sensors were fabricated by a multistep microfabrication approach combining sputtering (to deposit the electrode materialm, bismuth‐ and the insulator SiO2, on the surface of a silicon wafer) and photolithography (to define the geometry of the sensor). The effect of the preconcentration time, the preconcentration potential and the SW stripping parameters were investigated. Using the selected conditions, the 3σ limit of detection was 0.6 µg L?1 of Tl(I) at a preconcentration time of 240 s and the percent relative standard deviation was 4.3 % at the 10 µg L?1 level (n=8). In order to eliminate the interference caused by Pb(II) and Cd(II), EDTA was added in the sample solution The method was successfully applied to the determination of Tl(I) in a certified lake water sample. These new sensors exhibit excellent mechanical stability and offer wide scope as mercury‐free disposable sensors for trace metal analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号