首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
《Electroanalysis》2004,16(17):1439-1443
A film of poly‐L ‐lysine (PLL) adheres better to the surface of a glassy carbon electrode when the PLL is partially cross‐linked by means of glutaraldehyde. A film composition of 97.5% PLL/2.5% glutaraldehyde gives good adhesion and retains the anionic exchange capability of the PLL. The performance of the film was tested with hexacyanoferrate(III) using electrochemical and nonelectrochemical accumulation.  相似文献   

2.
Silicomolybdate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐SiMo) film modified glassy carbon electrode was successfully prepared by means of electrostatically trapping the silicomolybdate anion in PLL‐GA cationic coating. The PLL‐GA‐SiMo film was stable and the charge transport through the film was fast. The modified electrode shows excellent electrocatalytic activity towards bromate reduction with significant reduction of overpotential. In amperometric determination of bromate, the calibration plot was linear over the concentration range of 5×10?5 to 1.2×10?3 M with a sensitivity of 3.6 μA mM?1. Furthermore, PLL‐GA‐SiMo film electrode showed fast response and good stability.  相似文献   

3.
An electrochemical DNA sensing film was constructed based on the multilayers comprising of poly‐L ‐lysine (pLys) and Au‐carbon nanotube (Au‐CNT) hybrid. A precursor film of mercaptopropionic acid (MPA) was firstly self‐assembled on the Au electrode surface. pLys and Au‐CNT hybrid layer‐by‐layer assembly films were fabricated by alternately immersing the MPA‐modified electrode into the pLys solution and Au‐CNT hybrid solution. Cyclic voltammetry was used to monitor the consecutive growth of the multilayer films by utilizing [Fe(CN)6]3?/4? and [Co(phen)3]3+/2+ as the redox indicators. The outer layer of the multilayer film was the positively charged pLys, on which the DNA probe was easily linked due to the strong electrostatic affinity. The hybridization detection of DNA was accomplished by using methylene blue (MB) as the indicator, which possesses different affinities to dsDNA and ssDNA. Differential pulse voltammetry was employed to record the signal response of MB and determine the amount of the target DNA sequence. The established biosensor has high sensitivity, a relatively wide linear range from 1.0×10?10 mol/L to 1.0×10?6 mol/L and the ability to discriminate the fully complementary target DNA from single or double base‐mismatched DNA. The sequence‐specific DNA related to phosphinothricin acetyltransferase gene from the transgenically modified plants was successfully detected.  相似文献   

4.
《Electroanalysis》2005,17(14):1309-1316
The detection limit (about 0.017 μg mL?1) for voltammetric determination of iodide (peak at +0.87 V vs. Ag/AgCl at pH 2) at a glutaraldehyde‐cross‐linked poly‐L ‐lysine modified glassy carbon electrode involving oxidation to iodine was found to be several orders of magnitude lower than that for the voltammetric determination on a bare glassy carbon electrode. This method was applied successfully to the determination of iodide in two medicinal formulations. Idoxuridine was determined indirectly at the same electrode by accumulating it first at ?0.8 V vs. Ag/AgCl. At this potential the C? I bond in the adsorbed idoxuridine is reduced giving iodide, which is then determined at the modified electrode. The method was successfully applied to the determination of idoxuridine in a urine sample.  相似文献   

5.
A new strategy to make the electrochemical sensor was presented, through combining gold nanoparticles (GNPs) with reduced graphene oxide (rGO) via L‐cysteine (L‐cys) as crosslinker. The resulting electrodes were characterized by scanning electron microscopy (SEM) and electrochemical methods. And it was applied to develop a high‐sensitive electrochemical sensor for determination of sophoridine. Compared with the bare GCE and reduced graphene oxide modified electrode, the resulting electrodes exhibited excellent response toward the oxidation of sophoridine by significantly enhancing the oxidation peak currents and decreasing the overpotential of sophoridine. Under the selected conditions, there exist the linear relation between the oxidation peak currents and sophoridine concentration in the range of 1.0 x 10‐6~1.0 x 10‐4 mol L‐1, with detection limit of 4.0 x 10‐7 mol L‐1. At the same time, the method can be successfully applied to the quantitative determination of sophoridine in injection samples and its result is satisfactory.  相似文献   

6.
Silicomolybdate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐SiMo) film modified glassy carbon electrode was prepared by means of electrostatically trapping the silicomolybdate anion in the cationic film. The PLL‐GA‐SiMo film was stable and the charge transport through the film was fast. The modified electrode shows excellent electrocatalytic activity towards hydrogen peroxide reduction with significant reduction of overpotential, however, not responded to potential interferrents such as dopamine, ascorbic acid and uric acid. This unique feature of PLL‐GA‐SiMo modified electrode allowed for the development of a highly selective method for the determination of H2O2 in the presence of interferents.  相似文献   

7.
The present work describes oxidation of ascorbic acid (AA) at octacyanomolybdate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐Mo(CN) film modified glassy carbon electrode in 0.1 M H2SO4. The modified electrode has been successfully prepared by means of electrostatically trapping Mo(CN) mediator in the cationic film of glutaraldehyde‐cross‐linked poly‐L ‐lysine. The dependence of peak current of modified electrode in pure supporting indicates that the charge transfer in the film was a mixed process at low scan rates (5 to 200 mV s?1), and kinetically restrained at higher scan rates (200 to 1000 mV s?1). Cyclic voltammetry and rotating disk electrode (RDE) techniques are used to investigate the electrocatalytic oxidation of ascorbic acid and compared with its oxidation at bare and undoped PLL‐GA film coated electrodes. The rate constant of catalytic reaction k obtained from RDE analysis was found to be 9.5×105 cm3 mol?1 s?1. The analytical determination of ascorbic acid has been carried out using RDE technique over the physiological interest of ascorbic acid concentrations with a sensitivity of 75 μA mM?1. Amperometric estimation of AA in stirred solution shows a sensitivity of 15 μA mM?1 over the linear concentration range between 50 and 1200 μM. Interestingly, PLL‐GA‐Mo(CN) modified electrode facilitated the oxidation of ascorbic acid but not responded to other electroactive biomolecules such as dopamine, uric acid, NADH, glucose. This unique feature of PLL‐GA‐Mo(CN) modified electrode allowed for the development of a highly selective method for the determination of ascorbic acid in the presence of interferents.  相似文献   

8.
The present work describes reduction of iodate (IO3?), and periodate (IO4?) at silicomolybdate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐SiMo) film coated glassy carbon electrode in 0.1 M H2SO4. In our previous study, we were able to prepare the PLL‐GA‐SiMo film modified electrode by means of electrostatically trapping SiMo12O404? mediator in the cationic film of PLL‐GA, and the voltammetric investigation in pure supporting indicated that the charge transport through the film was fast. Here, the electrocatalytic activity of PLL‐GA‐SiMo film electrode towards iodate and periodate was tested and subsequently used for analytical determination of these analytes by amperometry. The two electron reduced species of SiMo12O404? anion was responsible for the electrocatalytic reduction of IO3? at PLL‐GA‐SiMo film electrode while two and six electron reduced species were showed electrocatalytic activity towards IO4? reduction. Under optimized experimental conditions of amperometry, the linear concentration range and sensitivity are 2.5×10?6 to 1.1×10?2 M and 18.47 μA mM?1 for iodate, and 5×10?6 to 1.43×10?4 M and 1014.7 μA mM?1 for periodate, respectively.  相似文献   

9.
Liquid‐crystal (LC) droplet patterns are formed on a glass slide by evaporating a solution of nematic LC dissolved in heptane. In the presence of an anionic phospholipid, 1,2‐dioleoyl‐sn‐glycero‐3‐phospho‐rac‐(1‐glycerol) (DOPG), the LCs display a dark cross pattern, indicating a homeotropic orientation. When LC patterns are incubated with an aqueous mixture of DOPG and poly‐L ‐lysine (PLL), there is a transition in the LC pattern from a dark cross to a bright fan shape due to the electrostatic interaction between DOPG and PLL. Known to catalyze the hydrolysis of PLL into oligopeptide fragments, trypsin is preincubated with PLL, significantly decreasing the interactions between PLL and DOPG. LCs adopt a perpendicular orientation at the water–LC droplet interface, which gives rise to a dark cross pattern. This optical response of LC droplets is the basis for a quick and sensitive biosensor for trypsin.  相似文献   

10.
A simple but highly snesitive electrochemical sensor for the determination of dihydromyricetin (DMY) based on graphene‐Nafion nanocomposite film modified Glassy carbon electrode (GCE) was reported. The characteristic of the sensor was examined by scanning electron microscopic (SEM) and electrochemical impedance spectroscopy (EIS). Compares with bare GCE, pre‐anodized glassy carbon electrode (GCE(ox)) and Nafion modified electrode, the sensor exhibited the more superior ability of detecting DMY, due to the synergetic graphene and Nafion. Other, the dependence of the current on pH, instrumental parameters, accumulation time and potential were investigated to optimize the experimental conditions in the determination of DMY. Under the selected conditions, the response peak currents were linear relationship with the DMY concentrations in the range of 8.0 × 10?8 ~ 2.0 × 10?5 mol L?1 with a detection limit of 2.0 × 10?8 mol L?1. And, the method was also applied successfully to detect DMY in Ampelopsis grossedentata samples.  相似文献   

11.
The present work describes preparation of hemoglobin‐incorporated multiwalled carbon nanotubes‐poly‐L ‐lysine (MWCNT‐PLL)/Hb) composite modified electrode film modified glassy carbon electrode (GCE) and its electrocatalytic behavior towards reduction of bromate ( ) in 0.1 M acetate buffer (pH 5.6). The modified electrode has been successfully fabricated by immobilizing hemoglobin on MWCNT dispersed in poly‐L ‐lysine. The surface morphologies of MWCNT, PLL and Hb were characterized using atomic force microscopy (AFM). The voltammetric features suggested that the charge transport through the film was fast and the electrochemical behavior resembles that of surface‐confined redox species. Cyclic voltammetry was used to investigate the electrocatalytic behavior of the modified electrode towards bromate and was compared with that of the CNT‐modified as well as bare electrode. The analytical determination of bromate has been carried out in stirred solution at an optimized potential with a sensitivity of 7.56 μA mM?1 and the calibration curve was linear between 1.5×0?5 to 6.0×0?3 M.  相似文献   

12.
Glassy carbon electrode modified with phosphotungstate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐PW) film was employed for iodate determination. The PLL‐GA‐PW film electrode shows excellent electrocatalytic activity towards iodate reduction with significant reduction of overpotential. Under optimized experimental conditions, a linear range from 5×10?8 to 2.27×10?2 M with a sensitivity of 61.75 μA mM?1 was obtained. Possible interfering species, in iodate determination, were evaluated and the applicability of proposed sensor for iodate estimation in table salt was also demonstrated. The PLL‐GA‐PW film electrode shows fast response, wider linear range, and good selectivity and stability.  相似文献   

13.
Despite the increasing number of applications of molecularly imprinted polymers (MIPs) in analytical chemistry, the construction of a biomimetic potentiometric sensor remains still challenging. In this work, a biomimetic potentiometric sensor, based on a non‐covalent imprinted polymer was fabricated for the recognition and determination of cetirizine. The MIP was synthesized by precipitation polymerization, using cetirizine dihydrochloride as a template molecule, methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross linking agent. The sensor showed high selectivity and a sensitive response to the template in aqueous system. The MIP‐modified electrode exhibited Nernstian response (28.0±0.9 mV/decade) in a wide concentration range of 1.0×10?6 to 1.0×10?2 M with a lower detection limit of 7.0×10?7 M. The electrode has response time of ca. 20 s, high performance, high sensitivity, and good long term stability (more than 5 months). The method was satisfactory and used to the cetirizine assay in tablets and biological fluids.  相似文献   

14.
The synthesis and characterization of two new capped silica mesoporous nanoparticles for controlled delivery purposes are described. Capped hybrid systems consist of MCM‐41 nanoparticles functionalized on the outer surface with polymer ε‐poly‐L ‐lysine by two different anchoring strategies. In both cases, nanoparticles were loaded with model dye molecule [Ru(bipy)3]2+. An anchoring strategy involved the random formation of urea bonds by the treatment of propyl isocyanate‐functionalized MCM‐41 nanoparticles with the lysine amino groups located on the ε‐poly‐L ‐lysine backbone (solid Ru‐rLys‐S1 ). The second strategy involved a specific attachment through the carboxyl terminus of the polypeptide with azidopropyl‐functionalized MCM‐41 nanoparticles (solid Ru‐tLys‐S1 ). Once synthesized, both nanoparticles showed a nearly zero cargo release in water due to the coverage of the nanoparticle surface by polymer ε‐poly‐L ‐lysine. In contrast, a remarkable payload delivery was observed in the presence of proteases due to the hydrolysis of the polymer’s amide bonds. Once chemically characterized, studies of the viability and the lysosomal enzyme‐controlled release of the dye in intracellular media were carried out. Finally, the possibility of using these materials as drug‐delivery systems was tested by preparing the corresponding ε‐poly‐L ‐lysine capped mesoporous silica nanoparticles loaded with cytotoxic drug camptothecin (CPT), CPT‐rLys‐S1 and CPT‐tLys‐S1 . Cellular uptake and cell‐death induction were studied. The efficiency of both nanoparticles as new potential platforms for cancer treatment was demonstrated.  相似文献   

15.
A boron‐doped diamond (BDD) electrode coupled to flow injection analysis (FIA) was firstly developed for determination of N‐acetyl‐L ‐cysteine (NAC) in drug formulations. The effects of experimental parameters including pH, applied potential and scan rate on the response were investigated. FIA amperometry was applied as an automatic method for the quantitative detection of trace amounts of NAC. A wide linear range of 0.5–50 µmol/L and a low detection limit of 10 nmol/L were obtained. The results of amperometric determinations show a very good reproducibility, and the RSD for the measurement based on 10 measurements was <3.7 % and <4.1 % for intra‐ and inter‐day, respectively. The benefits of the proposed method are fast, simple, sensitive and no requirement of complicated operational steps.  相似文献   

16.
We developed an electrochemical system for detecting lipopolysaccharide (LPS) that uses an ultraflat nanocarbon film electrode modified with poly‐ε‐lysine with a high affinity to LPS. LPS was captured on the modified electrode, and then ferrocene labeled polymyxin B (FcPMB) was captured on the LPS adsorbed electrode via the LPS‐PMB affinity interaction. The adsorbed FcPMB provided an amplified response with Fe2+ ions, and the current response was dependent on the amount of captured LPS (LOD=2.0 ng/mL). This was due to the efficient accumulation of the obtained current for LPS and the very low noise made possible by the ultraflat surface.  相似文献   

17.
A ferrocene‐labeled high molecular weight coenzyme derivative (PEI‐Fc‐NAD) and a thermostable NAD‐dependent L ‐lysine 6‐dehydrogenase (LysDH) from thermophile Geobacillus stearothermophilus were used to fabricate a reagentless L ‐lysine sensor. Both LysDH and PEI‐Fc‐NAD were immobilized on the surface of a gold electrode by consecutive layer‐by‐layer adsorption (LBL) technique. By the simple LBL method, the reagentless L ‐lysine sensor, with co‐immobilization of the mediator, coenzyme, and enzyme was obtained, which exhibited current response to L ‐lysine without the addition of native coenzyme to the analysis system. The amperometric response of the sensor was dependent on the applied potential, bilayer number of PEI‐Fc‐NAD/LysDH, and substrate concentration. A linear current response, proportional to L ‐lysine concentration in the range of 1–120 mM was observed. The response of the sensor to L ‐lysine was decreased by 30% from the original activity after one month storage.  相似文献   

18.
The first ( PG1 ) and second ( PG2 ) generation dendronized polymethacrylates with L ‐lysine based dendrons have been synthesized, and their conformation has been investigated. The chiral dendrons can be synthesized efficiently on a multi‐gram scale from L ‐lysine by a solution peptide coupling method, and the over‐all yields for the first ( MG1 ) and second ( MG2 ) generation macromonomers are 77 and 75%, respectively. High molar masses (1 to 2 million) of PG1 and PG2 are achieved by conventional radical polymerization of the corresponding macromonomers. Characterization with optical rotation, circular dichroism, and UV measurements showed that, in contrast to PG1 , PG2 adopts a single‐handed helical conformation in solution, which is stable in different polar solvents and also over a broad temperature range. Interestingly, the stable helical conformation remained in aqueous solution after deprotection of the terminal amines, by which the mass and steric hindrance of the dendrons reduced significantly.

  相似文献   


19.
20.
A novel poly‐L ‐arginine group microcapsule was produced to investigate its nutritional function and pharmacological efficacy. The molecular weight of poly‐L ‐arginine is an important parameter for its membrane strength, but does not obviously affect its release property. Thus, poly‐L ‐arginine can be used as a kind of new membrane material in microcapsules, and it is expected to be used as an therapeutic and biodegradable drug carrier.

Influence of the molecular weight of poly‐L ‐arginine on membrane thickness.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号