首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, the capability of carbon nanofibers to be used for the design of catalytic electrochemical biosensors is demonstrated. The direct electrochemistry of NADH was studied at a glassy carbon electrode modified using carbon nanofibers. A decrease of the oxidation potential of NADH by more than 300 mV is observed in the case of the assembled carbon nanofiber‐glassy carbon electrode comparing with a bare glassy carbon electrode. The carbon nanofiber‐modified electrode exhibited a wide linear response range of 3×10?5 to 2.1×10?3 mol L?1 with a correlation coefficient of 0.997 for the detection of NADH, a high specific sensitivity of 3637.65 (μA/M cm2), a low detection of limit (LOD=3σ) of 11 μM, and a fast response time (3 s). These results have confirmed the fact that the carbon nanofibers represent a promising material to assemble electrochemical sensors and biosensors.  相似文献   

2.
《Electroanalysis》2005,17(4):289-297
Gold nanocrystal‐modified glassy carbon electrodes (nAu‐GCE) were prepared and used for the determination of histamine by flow injection and high performance liquid chromatography using pulsed amperometric detection (PAD) as the detection mode. Experimental variables involved in the electrodeposition process of gold from a HAuCl4 solution were optimized. A catalytic enhancement of the histamine voltammetric response was observed at the nAu‐GCE when compared with that obtained at a conventional Au disk electrode, as a consequence of the microdispersion of gold nanocrystals on the GC substrate. The morphological and electrochemical characteristics of the nAu‐GCE were evaluated by SEM and cyclic voltammetry. PAD using a very simple potential waveform consisting of an anodic potential (+700 mV for 500 ms) and a cathodic potential (?300 mV for 30 ms), was used to avoid the electrode surface fouling when histamine was detected under flowing conditions. Flow injection amperometric responses showed much higher Ip values and signal‐to‐noise ratios at the nAu‐GCE than at a conventional gold disk electrode. A limit of detection of 6×10?7 mol L?1 histamine was obtained. HPLC‐PAD at the nAu‐GCE was used for the determination of histamine in the presence of other biogenic amines and indole. Histamine was determined in sardine samples spiked at a 50 μg g?1 concentration level, with good results. Furthermore, the chromatographic PAD method was also used for monitoring the formation of histamine during the decomposition process of sardine samples.  相似文献   

3.
《Electroanalysis》2006,18(21):2092-2098
Gold‐bead electrodes were modified by covalent bonding or physical adsorption of several Starburst PAMAM dendrimers (generations 2.0, 3.0 and 4.0) followed by absorption of Prussian Blue (PB). The covalent dendrimer‐PB‐modified electrodes can be used as amperometric sensors of H2O2 in aqueous solution. They offer enhanced sensitivity with correspondingly lower detection and quantification limits compared to similar amperometric detectors.  相似文献   

4.
《Electroanalysis》2018,30(3):509-516
The effect of the oxidation degree of multiwalled carbon nanotubes (MWCNTs) for the detection of NADH was evaluated in this paper. MWCNTs were oxidized by microwave‐assisted sulfonitic treatment at different times (5, 10, 15, and 30 min) and deposited onto a graphite screen printed electrodes. Oxidized MWCNTs were characterized and the electrochemical performance evaluated. The best sensor in terms of sensitivity and stability was obtained after 15 minutes of oxidation (SPE/CNT15). A significant reduction of the NADH oxidation potential was recorded for oxidized MWCNTs compared with unmodified MWCNTs (0.270 V and 0.500 V, respectively vs. Ag/AgCl pseudo reference electrode), increasing the selectivity of the system. Chronoamperometric calibration curves carried out applying a potential of 0.3 V for 1 min were linear in the 4–35 μM range of NADH. A limit of detection of 1 μM was achieved with negligible surface fouling (three consecutive calibration curves, 30 total measurements: slope decrease 5.9 %). Inter electrode reproducibility (n=13) was good resulting in RSD of 15.2 % and 5.0 % for the peak intensity and the oxidation potential, respectively. Quantification of glucose in white wine samples was carried out to demonstrate the ability of the NADH sensor to work in real samples. A good correlation with a spectrophotometric kit for the glucose quantification was achieved.  相似文献   

5.
A sensitive voltammetric method for detection of trace heavy metal ions using chemically modified carbon nanotubes (CNTs) electrode surfaces is described. The CNTs were covalently modified with cysteine prior to casting on electrode surfaces. Cysteine is an amino acid with high affinities towards some heavy metals. In this assay, heavy metals ions accumulated on the cysteine‐modified CNT electrode surfaces prior to being subjected to differential pulse anodic stripping voltammetry analysis. The resulting peak currents were linearly related to the concentrations of the metal ions. The method was optimized with respect to accumulation time, reduction time and reduction potential. The detection limits were found to be 1 ppb and 15 ppb for Pb2+ and Cu2+ respectively. The technique was used for the detection of Pb2+ and Cu2+ in spiked lake water. The average recoveries of Pb2+ and Cu2+ were 96.2% and 94.5% with relative standard deviations of 8.43% and 7.53% respectively. The potential for simultaneous detection of heavy metal ions by the modified CNTs was also demonstrated.  相似文献   

6.
The polymer, poly(vinylferrocenium) (PVF+) modified electrode was developed as the first time herein for the improved electrochemical sensing of DNA based on the oxidation signals of polymer and guanine. The morphologies of polymer film and DNA immobilized polymer film were examined using scanning electron microscope (SEM). The electrochemical behavior of polymer modified electrode was investigated by using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in the absence/presence of DNA. Experimental parameters, such as the polymeric film thickness, the DNA immobilization time, the concentration of buffer solution, pH and DNA concentration were examined in order to obtain more sensitive and selective electrochemical signals. After optimization studies, DNA hybridization was also investigated.  相似文献   

7.
This paper reports the use of a tetracycline (TC) sensor constructed from a combination of molecularly imprinted polymer (MIP) and gold nanoparticles modified multiwall carbon nanotubes (MWNTs‐GNPs). The results demonstrated that the amount of recognition sites in the polymer was significantly increased and the electron transfer ability of the sensor was improved. The relationship between the peak current and the TC concentration was linear in the range from 0.1 to 40 mg L?1, and the detection limit was 0.04 mg L?1 (S/N=3). The peak current to TC was 4.3, 6.2 and 6.8 times larger than that of oxytetracycline, chloramphenicol and nafcillin, respectively. Thus, the combination of MIP and MWNTs‐GNPs provides a sensitive and selective electrochemical detection method for tetracycline.  相似文献   

8.
This paper demonstrates the development of an analytical method for detecting steroid hormones by coupling HPLC to electrochemical detection, using a nickel‐modified glassy carbon electrode. The method was evaluated in terms of sensitivity, linear dynamic range, limit of detection, and response stability. The developed method exhibited good figures of merit for the steroid hormones studied with no evidence of electrode fouling. As an example, the limit of detection (S/N=3) for E3 was 0.10 µM and the response precision (n=5) was 0.6 %. The application of the method for the analysis of a real river water sample is demonstrated.  相似文献   

9.
《Analytical letters》2012,45(6):912-922
An amine-Fe3O4 modified glassy carbon (GC) electrode was constructed for detecting Pb(II) ions in wastewater. The electrode was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Square wave anodic stripping voltammetry (SWASV) was used to detect the Pb(II), and the detection limit of Pb(II) was 0.15 µM. The sensitivity of the electrode to detect Pb(II) was about 10.07 µA/µM, with a correlation coefficient of 0.991, which was approximately 10 times bigger than that of a pure Fe3O4 modified electrode. The electrode also showed good selectivity and stability. This results indicated that the amine-magnetite material could have some potential applications in heavy metal ions detection in wastewater.  相似文献   

10.
《Electroanalysis》2005,17(14):1325-1330
Interference by Cu(II) causes serious problems in the detection of As(III) using anodic stripping voltammetry at gold electrodes. The behavior of Cu(II) and As(III) were examined at both a gold macro electrode and two kinds of gold nanoparticle modified electrodes, one where gold particles are deposited on glassy carbon (GC) and the other where basal plane pyrolytic graphite (BPPG) is the substrate. The sensitivity of As(III) detection was higher on gold nanoparticle modified electrodes than those on a macro gold electrode by up to an order of magnitude. In addition, the stripping peak of As(III) was narrower and more symmetric on a gold nanoparticle‐modified GC electrode, leading to analytical data with a lower limit of detection. At a macro gold electrode, the peak currents of Cu(II) were higher than those on gold nanoparticle modified electrodes. Accordingly, through the use of gold nanoparticle modified electrodes, the effect of copper interference to the arsenic detection can be reduced.  相似文献   

11.
Electrochemical detection of dopamine (DA) in the presence of a large excess of ascorbic acid (AA) was investigated with a novel all‐carbon nanocomposite film of C60‐MWCNTs (C60‐functionalized multi‐walled carbon nanotubes) using a bare MWCNTs film as control. Although both films can selectively detect DA from AA by separating their oxidation potentials, the C60‐MWCNTs film shows special selectivity and good sensitivity for detecting DA. On one hand, the C60‐MWCNTs composite film shows a higher activity for DA oxidation with enhanced peak current. On the other hand, the C60‐MWCNTs composite film effectively suppresses the oxidation of AA. Remarkably, it is found that the oxidation current of DA is over 2 times higher than that of AA even when the concentration of AA is about 3 to 4 orders of magnitude higher than that of DA. This offers a tremendous advantage for the simple and clean detection of DA free of the interfering AA signal in a real assay. Cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectrometry are used to characterize the C60‐MWCNTs composite film. These novel properties are interpreted to arise from the facile electron transfer between C60 and MWCNTs in the C60‐MWCNTs nanocomposite film.  相似文献   

12.
分别以2种阴离子表面活性剂(SDS、SDBS)、3种季铵盐阳离子表面活性剂(CTAB、TTAB、DTAB)和2种季铵盐型双子表面活性剂(12-3-12、12-4-12)修饰碳糊电极。通过原子力显微镜、接触角以及分析物在电极表面的电化学行为探讨了不同表面活性剂在电极表面的吸附情况,推测在浓度大于临界胶束浓度(CMC)时,季铵盐型阳离子表面活性剂CTAB、TTAB、12-3-12和12-4-12在碳糊电极表面形成了圆柱形的表面胶团,而DTAB和SDS可能是饱和单分子层吸附。以BPA为分析物,研究了表面活性剂修饰电极对BPA的电化学增敏机理,结果表明修饰电极对双酚A(BPA)的电化学增敏作用主要是因为表面胶团对BPA的增溶作用,表面活性剂和BPA间的阳离子-π作用是表面胶团增溶BPA的主要原因。  相似文献   

13.
A self‐assembled monolayer (SAM) modified by 4‐formylphenylboronic acid was formed on the gold electrode, which was applied for the determination of trace concentrations of Cu(II). The formation of advanced SAM on the gold electrode was evidenced by electrochemical impedance spectroscopy, atomic force microscopy and contact angle measurements. Electrochemical determination of Cu(II) ions was performed by square wave voltammetry. Some mutual interferences caused by Cd(II), Co(II), Fe(II), Ni(II) and Pb(II) ions were investigated and it was demonstrated how the negative effects of these interfering ions could be eliminated by adjustment of proper parameters of square wave voltammetry.  相似文献   

14.
汪学英  顾锋  尹凡  屠一锋 《分析化学》2012,40(5):657-662
在0.1 mol/L磷酸盐缓冲溶液(PBS,pH 7.0)中,于2.0V恒电位电解10 min,即可在金电极表面原位、快速制备纳米功能化修饰膜.经原子力显微镜表征,此修饰膜具有纳米尺度的蓬松结构.此纳米金膜对细胞膜上脂质过氧化反应具有显著的催化作用,因而对细菌产生电流响应.采用传统的标准平板计数法对试样进行细菌培养计数作为校正,以计时电流法电流响应作为输出信号进行细菌的测定,响应电流和细菌数量呈线性关系,据此可对牛奶样品中细菌浓度进行快速测定.本方法的测定范围为1.1×103~2.5×107 cfu/mL,检测时间缩短至1h以内,较平板计数法有显著改善.  相似文献   

15.
《Electroanalysis》2006,18(11):1105-1113
We report for the first time the effective catalytic electrooxidation of nicotinamide adenine dinucleotide (NADH) on the pencil 8B‐scrawled gold electrode of an electrochemical quartz crystal microbalance (EQCM). The EQCM allowed us to quantitatively evaluate the catalytic activity of the pencil‐scrawled Au electrode. With increasing the mass of modified pencil powders, the peak potential for NADH oxidation shifted negatively, with maximum shift of ?0.35 V at saturated pencil modification; the NADH‐oxidation peak current density (jp) was also notably increased, and the jp at saturated pencil modification was found to be larger than those at conventional pencil 8B and bare Au electrodes. Sensitive amperometric detection of NADH was achieved at the gold electrode with saturated pencil modification, with low detection potential (0.4 V versus SCE), low detection limit (0.08 μmol L?1) and wide linear range (0.2–710 μmol L?1). The fluoroelectrochemical measurements of NADH at bare and pencil‐modified gold electrodes were also conducted with satisfactory results. The convenient and low‐cost modification of pencil powders on the Au electrode may have presented a new functional surface of the EQCM, which is recommended for wider applications to bioelectrochemical studies, especially in view of the EQCM's capability of providing abundant in situ information in relevant processes.  相似文献   

16.
Mesoporous carbon ceramic SiO2/50 wt % C (SBET=170 m2 g?1), where C is graphite, were prepared by the sol‐gel method. The materials were characterized using N2 sorption isotherms, scanning electron microscopy, and conductivity measurements. The matrix was used as support for the in situ immobilization of Mn(II) phthalocyanine (MnPc) on their surface. XPS was used to determine the Mn/Si atomic ratios of the MnPc‐modified materials. Pressed disk electrodes were prepared with the MnPc‐modified matrix, and tested as an electrochemical sensor for nitrite oxidation. The linear response range, sensitivity, detection limit and quantification limit were 0.79–15.74 µmol L?1, 17.31 µA L µmol?1, 0.02 µmol L?1 and 0.79 µmol L?1, respectively, obtained using cyclic voltammetry. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation was 1.7 % for 10 measurements of a solution of 12.63 µmol L?1 nitrite. The sensor employed to determine nitrite in sausage meat, river and lake water samples showed to be a promising tool for this purpose.  相似文献   

17.
The present work describes oxidation of ascorbic acid (AA) at octacyanomolybdate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐Mo(CN) film modified glassy carbon electrode in 0.1 M H2SO4. The modified electrode has been successfully prepared by means of electrostatically trapping Mo(CN) mediator in the cationic film of glutaraldehyde‐cross‐linked poly‐L ‐lysine. The dependence of peak current of modified electrode in pure supporting indicates that the charge transfer in the film was a mixed process at low scan rates (5 to 200 mV s?1), and kinetically restrained at higher scan rates (200 to 1000 mV s?1). Cyclic voltammetry and rotating disk electrode (RDE) techniques are used to investigate the electrocatalytic oxidation of ascorbic acid and compared with its oxidation at bare and undoped PLL‐GA film coated electrodes. The rate constant of catalytic reaction k obtained from RDE analysis was found to be 9.5×105 cm3 mol?1 s?1. The analytical determination of ascorbic acid has been carried out using RDE technique over the physiological interest of ascorbic acid concentrations with a sensitivity of 75 μA mM?1. Amperometric estimation of AA in stirred solution shows a sensitivity of 15 μA mM?1 over the linear concentration range between 50 and 1200 μM. Interestingly, PLL‐GA‐Mo(CN) modified electrode facilitated the oxidation of ascorbic acid but not responded to other electroactive biomolecules such as dopamine, uric acid, NADH, glucose. This unique feature of PLL‐GA‐Mo(CN) modified electrode allowed for the development of a highly selective method for the determination of ascorbic acid in the presence of interferents.  相似文献   

18.
Single‐wall carbon nanotubes (SWCNTs) were used as an immobilization matrix to incorporate [Ir(ppy)2(phen‐dione)](PF6) complex onto a glassy carbon electrode for the study of electrocatalytic reduction of periodate ion. Detailed preliminary electrochemical data for the Ir(III)‐complex in acetonitrile solution and for the modified GCE/SWCNTs/[Ir(ppy)2(phen‐dione)](PF6)/CGE are presented. The modified electrode was applied to selective amperometric detection of periodate through its electrocatalytic reduction to iodide at 0.200 V and pH 2.0. The use of amperometry resulted in two calibration plots over the concentration ranges of 1‐20 μM and 20‐450 μM, with a detection limit of 0.6 μM and sensitivity of 198 nA μM?1.  相似文献   

19.
A carbon-paste electrode chemically modified with a Schiff-base complex of cobalt (cobalt(II)-4-chlorosalophen, CoClSal) is utilized to investigate the voltammetric response of propylthiouracil (PTU). The mechanism of electrocatalytic oxidation of the compound is investigated by means of cyclic voltammetric studies applying various pHs to the buffered solutions. The modified electrode exhibits effective catalytic properties that lower the anodic overpotential and enhance the rate of electron transfer for the electrochemical oxidation of PTU. The results of the cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques showed that the modified electrode exhibits good selectivity for discriminating between the anodic wave of PTU and some biological thiols (e.g. cysteine) which may be present in human serum samples. DPV is used as a very sensitive electroanalytical method for the detection of trace amounts of PTU in pharmaceutical and clinical preparations. The results showed that the anodic peak current for the analyte in DPV varies linearly with the concentration of PTU in the range of 7.5 × 10−6 to 7.5 × 10−4 M (RSD for the slope of calibration curve <4%, n = 6).  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号