首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Electroanalysis》2005,17(17):1529-1533
The direct electrochemical oxidation of ascorbic acid at an edge plane pyrolytic graphite electrode (EPPG) is investigated and compared with other common carbon‐based electrodes, specifically glassy carbon, boron doped diamond and basal plane pyrolytic graphite. It is found that the EPPG electrode shows a significantly higher degree of electrochemical reversibility than the other electrode substrates giving rise to an analytically optimized limit of detection and sensitivity of 7.1×10?5 M and 0.065 A M?1 respectively.  相似文献   

2.
The electrochemical response of sodium levo‐thyroxin (T4) at the surface of an edge plane pyrolytic graphite (EPPG) electrode is investigated using cyclic voltammetric technique in the presence of 0.1 M HCl as supporting electrolyte. T4 underwent totally irreversible oxidation at this system and a well‐defined peak at 821 mV was obtained. Compared to the signals obtained in the optimized conditions at bare glassy carbon and carbon paste electrodes, the oxidation current of T4 at an EPPG electrode was greatly enhanced. The electrochemical process of T4 was explored and the experimental conditions were optimized. The oxidation peak current represented a linear dependence on T4 concentration from 0.01 to 10 µM. The detection limit of 3 nM (S/N=3) was obtained for 250 s accumulation at 0.3 V. Determination of T4 in a synthetic serum sample demonstrated that this sensor has good selectivity and high sensitivity.  相似文献   

3.
In this work, the electrochemical behavior of ferrocene (Fc) was investigated by cyclic voltammetry (CV) in room temperature ionic liquids (RTILs) of 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIBF4) on glass carbon (GC), edge plane pyrolytic graphite (EPPG) and multi‐walled carbon nanotube (MWCNTs)‐modified EPPG electrodes, respectively. The results demonstrated that on GC electrode, pairs of well‐defined reversible peaks were observed, while for the electrode of EPPG, the peak potential separation (ΔEp) is obviously larger than the theoretical value of 59 mV, hinting that the electrode of EPPG is distinguished from the commonly used electrode, consistent with the previous proposition that EPPG has many “defects”. To obtain an improved electrochemical response, multi‐walled carbon nanotubes (MWCNTs) were modified on the electrode of EPPG; the increased peak current and promoted peak potential separation not only proved the existence of “defects” in MWCNTs, but also supported that “creating active points” on an electrode is the main contribution of MWCNTs. Initiating the electrochemical research of Fc on the MWCNTs‐modified EPPG electrode in RTILs and verifying the presence of “defects” on both EPPG and MWCNTs using cyclic voltammograms (CVs) of Fc obtained in RTILs of EMIBF4, is the main contribution of this preliminary work.  相似文献   

4.
Antimony is an element of significant environmental concern, yet has been neglected relative to other heavy metals in electroanalysis. As such very little research has been reported on the electroanalytical determination of antimony at unmodified carbon electrodes. In this paper we report the electrochemical determination of Sb(III) in HCl solutions using unmodified carbon substrates, with focus on non-classical carbon materials namely edge plane pyrolytic graphite (EPPG), boron doped diamond (BDD) and screen-printed electrodes (SPE). Using differential pulse anodic stripping voltammetry, EPPG was found to give a considerably greater response towards antimony than other unmodified carbon electrodes, allowing highly linear ranges in nanomolar concentrations and a detection limit of 3.9?nM in 0.25?M HCl. Furthermore, the sensitivity of the response from EPPG was 100 times greater than for glassy carbon (GC). Unmodified GC gave a comparable response to previous results using the bare substrate, and BDD gave an improved, yet still very high limit of detection of 320?nM compared to previous analysis using an iridium oxide modified BDD electrode. SPEs gave a very poor response to antimony, even at high concentrations, observing no linearity from standard additions, as well as a major interference from the ink intrinsic to the working electrode carbon material. Owing to its superior performance relative to other carbon electrodes, the EPPG electrode was subjected to further analytical testing with antimony. The response of the electrode for a 40?nM concentration of Sb(III) was reproducible with a mean peak current of 1.07?µA and variation of 8.4% (n?=?8). The effect of metals copper, bismuth and arsenic were investigated at the electrode, as they are common interferences for stripping analysis of antimony.  相似文献   

5.
The effect of surface modifications on the electrochemical behavior of the anticancer drug idarubicin was studied at multiwalled carbon nanotubes modified glassy carbon and edge plane pyrolytic graphite electrodes. The surface morphology of the modified electrodes was characterized by scanning electron microscopy. The modified electrodes were constructed for the determination of idarubicin using adsorptive stripping differential pulse voltammetry. The experimental parameters such as supporting electrolyte, pH, accumulation time and potential, amount of carbon nanotubes for the sensitive assay of idarubicin were studied as details. Under the optimized conditions, idarubicin gave a linear response in the range 9.36×10?8–1.87×10?6 M for modified glassy carbon and 9.36×10?8–9.36×10?7 M for modified edge plane pyrolytic graphite electrodes. The detection limits were found as 1.87×10?8 M and 3.75×10?8 M based on modified glassy carbon and edge plane pyrolytic graphite electrodes, respectively. Interfering species such as ascorbic acid, dopamine, and aspirin showed no interference with the selective determination of idarubicin. The analyzing method was fully validated and successfully applied for the determination of idarubicin in its pharmaceutical dosage form. The possible oxidation mechanism of idarubicin was also discussed. The results revealed that the modified electrodes showed an obvious electrocatalytic activity toward the oxidation of idarubicin by a remarkable enhancement in the current response compared with bare electrodes.  相似文献   

6.
Electrochemical detection of hydrogen peroxide using an edge-plane pyrolytic-graphite electrode (EPPG), a glassy carbon (GC) electrode, and a silver nanoparticle-modified GC electrode is reported. It is shown, in phosphate buffer (0.05 mol L–1, pH 7.4), that hydrogen peroxide cannot be detected directly on either the EPPG or GC electrodes. However, reduction can be facilitated by modification of the glassy-carbon surface with nanosized silver assemblies. The optimum conditions for modification of the GC electrode with silver nanoparticles were found to be deposition for 1 min at –0.5 V vs. Ag from 5 mmol L–1 AgNO3/0.1 mol L–1 TBAP/MeCN, followed by stripping for 2 min at +0.5 V vs. Ag in the same solution. A wave, due to the reduction of hydrogen peroxide on the silver nanoparticles is observed at –0.68 V vs. SCE. The limit of detection for this modified nanosilver electrode was 2.0×10–6 mol L–1 for hydrogen peroxide in phosphate buffer (0.05 mol L–1, pH 7.4) with a sensitivity which is five times higher than that observed at a silver macro-electrode. Also observed is a shoulder on the voltammetric wave corresponding to the reduction of oxygen, which is produced by silver-catalysed chemical decomposition of hydrogen peroxide to water and oxygen then oxygen reduction at the surface of the glassy-carbon electrode.  相似文献   

7.
The voltammetric performance of glassy carbon (GC) and edge‐plane pyrolytic graphite (EPPG) electrodes was investigated for the oxidation of potassium ferrocyanide in aqueous solution both with and without the addition of surfactant (sodium dodecyl sulfate and Triton X‐100). The heterogeneous electron transfer kinetics were determined for all cases, and it was found that the GC electrode surface was far more sensitive to the presence of surfactant than the more hydrophilic EPPG surface. This result was then applied to the electroanalysis of copper via adsorptive stripping voltammetry in the presence of Triton X‐100 and it was observed that the EPPG electrode response was unaffected by up to 100 μM of surfactant, whilst the voltammetry on the GC electrode was significantly affected by only 10 μM.  相似文献   

8.
We report the comparison of electron transfer kinetic parameters of the ferrocene redox couple in both acetonitrile and in room temperature ionic liquid (RTIL) 1‐butyl‐3‐methylimidiazonium hexafluorophosphate ([C4mim] [PF6]), using edge plane pyrolytic graphite (EPPG), basal plane pyrolytic graphite (BPPG) and glassy carbon (GC) electrodes. Each electrode surface was characterized using SEM and AFM and the surface morphology was analyzed in terms of surface heterogeneity including the distribution of edge plane defects. The experimental data were modeled using both one and two dimensional simulations to correlate the electron transfer parameters obtained with the different surface structure of each electrode. Furthermore, we show that the diffusion domain approximation (commonly used to accurately simulate electron transfer kinetics at graphitic surfaces) breaks down when a BPPG electrode is used in RTIL and demonstrate the near impossibility of assigning rate constant to the basal plane surface.  相似文献   

9.
The electrochemical regeneration of NADH/NAD+ redox couple has been studied using poly(phenosafranin) (PPS)-modified carbon electrodes to evaluate the formal potential and catalytic rate constant for the oxidation of NADH. The PPS-modified electrodes were prepared by electropolymerization of phenosafranin onto different carbon substrates (glassy carbon (GC) and basal-plane pyrolytic graphite (BPPG)) in different electrolytic solutions. The formal potential was estimated to be ? 0.365 ± 0.002 V vs. SHE at pH 7.0. As for the bare carbon electrodes, the oxidation of NADH at the BPPG electrode was found to be enhanced compared with the GC electrode. For the PPS-modified electrodes, it was found that the electrocatalysis of PPS-modified electrodes for the oxidation of NADH largely depends on the carbon substrate and electrolyte solution employed for their preparation, i.e., the PPS-modified BPPG electrode prepared in 0.2 M NaClO4/acetonitrile solution exhibits an excellent and persistent electrocatalytic property toward NADH oxidation in phosphate buffer solution (pH 7.0) with a diminution of the overpotential of about 740 and 670 mV compared with those at the bare GC electrode and the PPS-modified GC electrode prepared in 0.2 M H2SO4 solution, respectively. A quantitative analysis of the electrocatalytic reaction based on rotating disk voltammetry gave the electrocatalytic reaction rate constants of the order of 103–104 M?1 s? 1 depending on the preparation conditions of the PPS-modified electrodes.  相似文献   

10.
Antimony(V) determination at an unmodified edge plane pyrolytic graphite (EPPG) electrode using anodic stripping voltammetry (ASV) by depositing beyond the hydrogen wave is shown in this paper. By depositing beyond the hydrogen wave, we report a sensitive method to determine pentavalent antimony at a carbon electrode in 0.25 M HCl. Using differential pulse anodic stripping voltammetry (DPASV), a bare EPPG electrode gave a detection limit of 5.8±0.02 nM without the need for surface modification. This level is greatly within the EU limit for drinking water of 40 nM.  相似文献   

11.
Pyrolytic carbon films (PCFs) were prepared by chemical vapor deposition (CVD) at different deposition temperatures. As an example of using PCF electrode in electroanalysis, the direct electrooxidation of ascorbic acid (AA) at the PCF electrode was investigated and compared with common carbon‐based electrodes such as glassy carbon (GC), edge plane pyrolytic graphite (EPPG), and basal plane pyrolytic graphite (BPPG) electrodes. It was found that the PCF electrodes prepared under deposition temperatures higher than 1050 °C showed a higher sensitivity and lower overpotential compared to the other carbon electrodes. The electrode was successfully applied for determination of AA in real samples.  相似文献   

12.
A square wave voltammetric procedure for the determination of trace amounts of Fe(III) was developed at an unmodified edge plane pyrolytic graphite (EPPG) electrode and a screen printed electrode (SPE). This simple procedure was applied to real samples of commercially bottled mineral water. Sensitive results in the micromolar region could be achieved without modification of the electrode. Using the WHO guideline limits for the Fe(III) concentration in drinking water, recovery percentages at an EPPG gave 103 % and 107 %, and 98.6 % and 95.0 % at a SPE for the 5.36 µM (0.3 mg L?1) and 53.6 µM (3.0 mg L?1) additions of Fe(III), respectively.  相似文献   

13.
《Analytical letters》2012,45(15):2929-2948
Abstract

This report describes the construction and characterization of an oxalate-sensing electrode. The electrode is based on the incorporation of ground beet stem into the graphite paste of a graphite paste electrode. The hydrogen peroxide generated by enzymatic degradation of oxalate is monitored at a working voltage of 0.900 V vs SCE. All measurements were conducted in a succinic acid/EDTA buffer at pH 4.00. Under these conditions, the electrodes exhibit reproducible responses to oxalate. The lower limit of oxalate detection was less than 1.03 × 10?4 M. The time to achieve a steady state response after exposure to a step change in oxalate concentration in solution is less than one minute. The magnitude of response to oxalate over the oxalate concentrations studied varies among several electrode tested as does the degree of linearity of response. An electrode studied still exhibited analytically useful responses to oxalate on the 15th day of its use. The beet stem-based electrodes display little response to glycolic acid, glucose, DL-valine, or pyruvate.  相似文献   

14.
《Analytical letters》2012,45(7):1289-1298
Abstract

Poly (acridine orange) (PAO) film–modified electrode was prepared by the electrooxidation of Acridine orange on a glassy carbon electrode (GCE) for the detection of hydroquinone in the presence of o‐hydroquinone and m‐hydroquinone. The electrochemical behavior of hydroquinone on the modified electrode was investigated with respect to different solution acidity, scan rate, and accumulation time. A pair of sharp and well‐defined peaks was obtained at 0.45 and 0.42 V [vs. a saturated calomel electrode (SCE)] at the PAO film–modified electrode. The potential difference between this pair of cathodic and anodic peaks was decreased to only 30 mV as compared to the 241 mV that was obtained on the bare glassy carbon electrode (GCE). As to o‐hydroquinone and m‐hydroquinone, their corresponding oxidation peaks appeared at 0.55 V and 0.89 V (vs. SCE), respectively. The oxidation potential differences between these three isomers enabled the separate detection of hydroquinone. Under the optimum experimental situation, the oxidation peak current of hydroquinone was proportional to the concentration at the range of 6.8×10?7–9.6×10?5 M. The detection limit was been estimated as 3×10?7 M with 130 s accumulation. This method was applied to the hydroquinone detection in tap water samples.  相似文献   

15.
A novel and reliable direct electrochemical method has been established to monitor DNA damage in acid hydrolyzed calf thymus DNA, based on the determination of 2,8‐dihydroxyadenine (2,8‐DHA). A single‐wall carbon nanotubes (SWCNT) modified edge plane pyrolytic graphite electrode (EPPGE) has been used as a sensor to monitor the DNA damage. 2,8‐DHA the main in vivo adenine oxidation product undergoes oxidation at ~395 mV at SWCNT modified EPPGE using square wave voltammetry (SWV). The sensor exhibits potent and persistent electron‐mediating behavior. A well‐defined oxidation peak for the oxidation of 2,8‐DHA was observed at modified electrode with lowering of peak potential and increase in peak current as compared to bare EPPGE. At optimal experimental conditions, the catalytic oxidative peak current was responsive with the 2,8‐DHA concentrations ranging from 0.05 nM to 100 nM. The detection limit was 3.8×10?11 M and limit of quantification was 1.27×10?10 M. The modified electrode exhibited high stability and reproducibility.  相似文献   

16.
Stable electroactive iron tetra(o-aminophenyl)porphyrin (FeTAPP) films are prepared by electropolymerization from aqueous solution by cycling the electrode potential between −0.4 and 1.0 V vs Ag/AgCl at 0.1 V s−1. The cyclic voltammetric response indicates that polymerization takes place after the oxidation of amino groups, and the films could be produced on glassy carbon (GC) and gold electrodes. The film growth of poly(FeTAPP) was monitored by using cyclic voltammetry and electrochemical quartz crystal microbalance. The cyclic voltammetric features of Fe(III)/Fe(II) redox couple in the film resembles that of surface confined redox species. The electrochemical response of the modified electrode was found to be dependent on the pH of the contacting solution with a negative shift of 57 mV/pH. The electrocatalytic behavior of poly(FeTAPP) film-modified electrode was investigated towards reduction of hydrogen peroxide, molecular oxygen, and chloroacetic acids (mono-, di-, and tri-). The reduction of hydrogen peroxide, molecular oxygen, and dichloroacetic acid occurred at less negative potential on poly(FeTAPP) film compared to bare GC electrode. Particularly, the overpotential of hydrogen peroxide was reduced substantially. The O2 reduction proceeds through direct four-electron reduction mechanism.  相似文献   

17.
于浩  郑建斌 《中国化学》2007,25(4):503-509
A copper hexacyanoferrate modified ceramic carbon electrode (CuHCF/CCE) had been prepared by two-step sol-gel technique and characterized using electrochemical methods. The resulting modified electrode showed a pair of well-defined surface waves in the potential range of 0.40 to 1.0 V with the formal potential of 0.682 V (vs. SCE) in 0.050 mol·dm^-3 HOAc-NaOAc buffer containing 0.30 mol·dm^-3 KCl. The charge transfer coefficient (a) and charge transfer rate constant (ks) for the modified electrode were calculated. The electrocatalytic activity of this modified electrode to hydrazine was also investigated, and chronoamperometry was exploited to conveniently determine the diffusion coefficient (D) of hydrazine in solution and the catalytic rate constant (kcat). Finally, hydrazine was determined with amperometry using the resulting modified electrode. The calibration plot for hydrazine determination was linear in 3.0 × 10^-6--7.5 × 10^-4 mol·dm^-3 with the detection limit of 8.0 × 10^-7 molodm^-3. This modified electrode had some advantages over the modified film electrodes constructed by the conventional methods, such as renewable surface, good long-term stability, excellent catalytic activity and short response time to hydrazine.  相似文献   

18.
The direct electrochemical oxidation of sodium sulfide has been examined at five different carbon-based electrode substrates (glassy carbon (GC), boron-doped diamond (BDD), edge-plane pyrollytic graphite (EPPG), basal-plane pyrollytic graphite (BPPG) and carbon nanotubes (CNT)). An electrocatalytic response is observed at both the EPPG and CNT electrode compared to that of the other three substrates. The higher capacitative charging currents obtained at the CNT electrode hinder its detection range and, as such, the EPPG electrode has been clearly shown to be the substrate of choice for the direct electrochemical detection of sulfide. The procedure was applied to the recovery of a sulfide spike in river water, with a recovery of 104%.  相似文献   

19.
An electrochemical study of the anthelmintic drug bithionol using edge plane pyrolytic graphite electrode (EPPGE) is presented for the first time by applying different electrochemical techniques, such as cyclic voltammetry (CV), square‐wave voltammetry (SWV), square‐wave adsorptive stripping voltammetry (SWAdSV), and alternating current (AC) impedance spectroscopy. Mechanistic aspects of the electrode reaction were studied implying a quasireversible electrode reaction from an adsorbed state of the reactant, coupled with a follow‐up chemical reaction to a final electroinactive product. The overall mechanism appears totally irreversible under conditions of CV at moderate scan rate, while being quasireversible under conditions of the fast SWV. Furthermore, an optimisation of the analytical procedure for quantitative determination of bithionol was conducted by applying SWV in an adsorptive stripping mode. The calibration curve was constructed in the concentration range of 0.1–1.0 μmol L?1 (R2=0.9984) with a sensitivity of 3.6 μA L μmol?1 and LOD of 26.7 nmol L?1. The simple and sensitive SWAdSV procedure was proved to be suitable for the analysis of spiked urine samples.  相似文献   

20.
《Electroanalysis》2005,17(9):783-788
In this work, a new porphyrin, the 5,10,15,20‐tetrakis‐(2,6‐difluoro‐3‐sulfonatophenyl) porphyrinato iron(III) chloride (denoted as FeTsP) was immobilized on SiO2/Al2O3 (SiAl) coated with n‐propylpyridiniumsilsesquioxane polymer (SiPy+Cl?). The FeTsP was adsorbed on SiAl/SiPyCl by an ion exchange reaction, obtaining a modified solid, SiAl/SiPy/FeTsP, where the porphyrin complex was strongly adhered. Cyclic voltammograms of the SiAl/SiPy/FeTsP carbon paste electrode showed an irreversible response, with an oxidation peak at Epa=0.40 V and nondefined reduction peak at Epc=0.15 V (vs. SCE). These peaks were not observed for the nonmetallated porphyrin, indicating that they probably correspond to the Fe(III)/Fe(II) process. Studies made in solutions having different pH, (between pH 2 and 9) using the modified electrode showed that the peak potentials and the current density were not affect by pH changes, indicating that the iron porphyrin is very stable and strongly entrapped in the matrix. The modified electrode presented the property to electrocatalyze the eletrooxidation of hydrazine at 0.41 V (vs. SCE), at pH 7. The potentiality of the SiAl/SiPy/FeTsP electrode as a sensor for hydrazine was evaluated by the using the chronoamperometric technique. A linear response was obtained in the concentration range between 5×10?5 and 6×10?4 mol L?1 of hydrazine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号