A distributed feedback diode laser sensor based upon off-axis cavity-enhanced absorption spectroscopy at 1605.5 nm has been developed for 13C16O2/12C16O2 isotope ratio measurements in synthetic air and human breath. A noise-equivalent absorption sensitivity of 3.9×10-10 cm-1 Hz-1/2 has been determined for a cavity base length of 28.2 cm and averaging 4000 scans within 8.688 s. For 5% CO2 concentration measurements, δ13C standard deviations of 1.8 ‰ and 3.7 ‰ have been estimated for five successive measurements based on peak height and integrated area estimations at 107.9 Torr, respectively. The contributions of amplified spontaneous emission of the laser and a radiation that is spatially uncoupled into the cavity mode have been described for cavity transmittance measurements. The limitations of the developed sensor and further steps towards precision and accuracy improvements are discussed. PACS 42.55.Px; 39.30.+w; 42.62.Fi; 42.60.-v  相似文献   

2.
The present paper describes a compact and cryogen-free, quantum cascade laser based absorption spectrometer (QCLAS) designed for in situ, continuous and high precision isotope ratio measurements of atmospheric CO2. The mobile instrument incorporates several new features including a novel astigmatic multi-pass cell assembly, a quasi-room temperature quantum cascade laser, thermoelectrically cooled detectors as well as a new retrieval approach. The combination of these features now makes it possible to measure isotope ratios of ambient CO2 with a precision of 0.03 and 0.05‰ for δ13C and δ18O, respectively, using a 100 s integration time. A robust and optimized calibration procedure was developed to bring the retrieved isotope ratios on an absolute scale. This assures an accuracy better than 0.1‰ under laboratory conditions. The instrument performance was also assessed in a field campaign in which the spectrometer operated autonomously and provided mixing ratio values for the main three CO2 isotopologues at one second time resolution. An accuracy of 0.2‰ was routinely obtained for both isotope ratios during the entire period. The results were in excellent agreement with the standard laboratory-based isotope ratio mass spectrometer measurements made on field-collected flask samples. A few illustrative examples are used to depict the potential of this optical method in atmosphere–biosphere research. PACS  07.57.Ty; 42.62.Fi; 92.60.Kc  相似文献   

3.
We report on the design and laboratory performance of a portable infrared absorption spectrometer for the measurement of the isotopic ratio 13C:12C in CO2. The design relies on optical feedback cavity-enhanced absorption spectroscopy in the 2 μm spectral region to achieve optimal performance at ambient CO2 concentrations. The prototype instrument measures δ13C, relative to a standard calibration bottle, with a precision of ±0.7‰ for a 20-s integration time and with an automatic recalibration every 6 min. The absolute accuracy obtained is 0.9‰. The principal performance limitations are discussed along with improvements currently being implemented for the second generation instrument. PACS  42.62.Fi; 07.57.Ty; 33.20.Ea  相似文献   

4.
We performed highly sensitive measurements of stable carbon isotopes of CO2 using wavelength modulation spectroscopy with a distributed feedback laser diode in the 2-μm wavelength range. Ro-vibrational transitions, which belong to the different combination bands, were selected to measure the 13CO2/12CO2 carbon isotope ratio. The δ 13C value was determined through the signals obtained in a Herriott-type multipass cell with an optical path length of 29.9 m. The limit of detection for CO2 using our measurement system was 16±1 parts per billion by volume at the strongest absorption peak that is assigned to the 2ν 1+ν 3 R(16) line within the laser emitting frequency region. The 10-h long term precision was a δ 13C standard deviation of 0.24‰ (1σ) with the best suited line pairs of 12CO2 and 13CO2 and with careful temperature and pressure control in the cell. The 3-min response and high precision of this measurement allows for precise continuous measurements of stable carbon isotopes in ambient CO2.  相似文献   

5.
We have developed a standalone, user-friendly, multi-species ringdown spectrometer for in situ measurements of methane (CH4), carbon dioxide (CO2), and a carbon dioxide isotope (13CO2). The instrument is based on near-infrared continuous-wave cavity ringdown spectroscopy (NIR cw-CRDS) and engineered to be of approximately 16 kg with dimensions of 50 cm × 40 cm × 15 cm. The instrument design, optical configuration, electronic control, and performance are described. CH4, CO2, and 13CO2 are measured at different wavelengths that are obtained through multiplexing two distributed feedback laser diodes with central wavelengths at 1597 and 1650 nm. The spectrometer has low power consumption and runs for 4–6 h when powered by a standard car battery. The instrument is operated either locally by interacting with a 7-inch touch screen or remotely via an Internet connection. The 1-σ detection limits for CH4 and CO2 are 0.2 and 120 ppmv, respectively. The measurement uncertainty is better than ±4% of full-scale reading for CH4 and CO2 and ±1.5‰ for δ13C (part per thousand relative to the Pee Dee Belemnite scale). Measurement of each species is near real-time; switching from measuring one species to another takes less than one minute. This work demonstrates a novel multiple-species CRDS-instrumentation platform, which can be adopted for development of an array of ringdown spectrometers for portable, user-friendly, field analysis of a variety of gases in environmental and industrial applications. Discussion of a future version of the spectrometer with better detection sensitivity, higher accuracy, and a smaller geometry is also presented. PACS  42.62.Fi; 42.55.Px; 33.20.Ea; 07.88.+y; 07.57.Ty  相似文献   

6.
A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8‰(±1σ) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 μm (∼2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations. Received: 16 April 2002 / Revised version: 28 May 2002 / Published online: 21 August 2002 RID="*" ID="*"Corresponding author. Fax: +1-713/5245237, E-mail: fkt@rice.edu  相似文献   

7.
We present a new approach to the measurement of stable isotopic ratios of carbon dioxide using a near-room-temperature pulsed quantum cascade laser and a spectral ratio method based upon dual multiple pass absorption cells. The spectral ratio method improves precision and accuracy by reducing sensitivity to variations in the laser tuning rate, power and line width. The laser is scanned across three spectral lines (near 2310 cm-1) quantifying three CO2 isotopologues: 12C16O2, 13C16O2 and 12C16O18O. Isotopic ratios are determined simultaneously with a precision of 0.2δ for each ratio with a one-second measurement. Signal averaging for 400 s improves the precision to better than 0.03δ for both isotopic ratios (13 R and 18 R). Long-term accuracy of 0.2 to 0.3δ is demonstrated with replicate measurements of the same sample over a one-month period. The fast time response of this instrument is suitable for eddy flux measurements. PACS 07.57.Ty; 42.62.Fi; 92.70.Cp; 91.67.Rx  相似文献   

8.
The feasibility of IR laser spectroscopy as a technique for the measurement of small abundances of stable and radioactive isotopes has been examined. Theoretical considerations and first experimental results with two laser systems are presented: 1) Coincidences between emission lines of a CO2-laser and absorption lines of13C-substituted ethylene can be used to determine the13C-concentration of C2H4. 2) A tunable PbS-diode laser emitting in the 4.3 μm-spectral region of the rotation-vibration bands of CO2 can be used to determine abundances of12C,13C,16O,17O and18O in small samples of CO2. With optimized performance, sensitivities up to 10−9–10−10 seem possible, and for higher abundances an accuracy of 10−3. This should allow geophysical isotope studies to be performed and it is hoped that the technique will eventually be applicable to measuring the activity of long-lived radioisotopes.  相似文献   

9.
The use of isotopic carbon dioxide lasers for determination of carbon (and oxygen) isotope ratios was first demonstrated in 1994. Since then a commercial device called LARA?, has been manufactured and used for Helicobacter pylori breath tests using 13C-labelled urea. The major advantages of the optogalvanic effect compared with other infrared absorption isotope ratio measurement techniques are its lack of optical background and its high sensitivity resulting from a signal gain proportional to laser power. Continuous normalisation using two cells, a standard and sample, lead to high accuracy as well as precision. Recent advances in continuous flow measurement of 13C/12C ratios of CO2 in air and extensions of the technique to 14C, which can be analysed as a stable isotope, are described.  相似文献   

10.
A near-IR laser absorption spectrometer using a technique of wavelength modulation spectroscopy is used to measure stable carbon isotope ratios of ambient CO213C) via the absorption lines 12CO2 R(17) (2ν1 + ν12  ν12 + ν3) at 4978.205 cm−1 and 13CO2 P(16) (ν1 + 2ν2 + ν3) at 4978.023 cm−1. The isotope ratios are measured with a reproducibility of 0.02‰ (1σ) in a 130-s integration time over a 12-h period. The humidity effect on δ13C values has been evaluated in laboratory experiments. The δ13C values of CO2 in ambient air were measured continuously over 8 days and agreed well with those from isotope ratio mass spectrometry of canister samples. The spectrometer is thus capable of real-time, in situ measurements of stable carbon isotope ratios of CO2 under ambient conditions.  相似文献   

11.
Abstract

Breath tests using 13C-labelled substrates require the measurement of 13CO2/12CO2 ratio in breath gas samples. Next to isotope ratio mass spectrometry (IRMS), which is very sensitive but also complex and expensive, alternatively isotope selective nondispersive infrared spectrometry (NDIRS) can be used to determine the 13CO2/12CO2 ratio in expired breath. In this study we compared NDIRS- with IRMS-results to investigate whether the less expensive and very simply to operate NDIRS works as reliable as IRMS. For this purpose we applicated 1-13C-Phenylalanine to patients with advanced liver cirrhosis and healthy volunteers and took duplicated breath samples for IRMS and NDIRS at selected time points. Our data show a good correlation between these two methods for a small number of samples as required for simple breath tests. Longer series, where repeated measurements are required on the NDIRS instrument lead to a decreasing correlation. This indicates the superiority of IRMS concerning 13CO2-kinetics over longer time periods.  相似文献   

12.
We present a nondispersive infrared spectrometer (NDIRS) for the measurement of the 13CO2/12CO2-ratio in breath samples. A commercial NDIR spectrometer for CO2 concentration measurements in industrial process control was modified using two separate optical channels for the 13CO2 and 12CO2 detection. Cross interference due to overlapping absorption lines of both isotopic gases was successfully eliminated. The sensitivity of this device is ± 0.4‰ of the 13CO2/12CO2-ratio in a range of 2.5 to 5% of total CO2. This is sufficient for biomedical applications. Our spectrometer is small in size, cheap and simple to operate and thus a true alternative to isotope ratio mass spectrometers (IRMS). Several biomedical applications with breath samples were demonstrated and were compared in very good agreement with IRMS.  相似文献   

13.
CO2 stable carbon isotopes are very attractive in environmental research to investigate both natural and anthropogenic carbon sources. Laser-based CO2 carbon isotope analysis provides continuous measurement at high temporal resolution and is a promising alternative to isotope ratio mass spectrometry (IRMS). We performed a thorough assessment of a commercially available CO2 Carbon Isotope Analyser (CCIA DLT-100, Los Gatos Research) that allows in situ measurement of δ 13C in CO2. Using a set of reference gases of known CO2 concentration and carbon isotopic composition, we evaluated the precision, long-term stability, temperature sensitivity and concentration dependence of the analyser. Despite good precision calculated from Allan variance (5.0 ppm for CO2 concentration, and 0.05 ‰ for δ 13C at 60 s averaging), real performances are altered by two main sources of error: temperature sensitivity and dependence of δ 13C on CO2 concentration. Data processing is required to correct for these errors. Following application of these corrections, we achieve an accuracy of 8.7 ppm for CO2 concentration and 1.3 ‰ for δ 13C, which is worse compared to mass spectrometry performance, but still allowing field applications. With this portable analyser we measured CO2 flux degassed from rock in an underground tunnel. The obtained carbon isotopic composition agrees with IRMS measurement, and can be used to identify the carbon source.  相似文献   

14.
A newly developed isotope selective nondispersive infrared (NDIR) spectrometer for the measurement of 13CO2 and 12CO2 concentrations in breath samples was applied as a low cost and very simple to operate alternative to isotope ratio mass spectrometry (IRMS). We used this device for several biomedical applications ([13C]urea breath test, [13C]leucine metabolism, [13C]methacetin catabolism of rats) and found that the results agree very well with IRMS.  相似文献   

15.
The paper is based on C12O2 16 rotational constants and line frequency data gained from laser frequency measurements performed recently. Equations for transition frequencies and their standard deviations have been derived. A list is presented containing accurate 10.4 and 9.4 μm line frequencies and their relative and absolute standard deviations; also wavenumbers and wavelengths are given for each line. For transitions usually observed in CO2 lasers the relative standard deviations are on the order of a few megahertz, the absolute accuracy is about 25 MHz for the 10.4 μm band and about 18 MHz for the 9.4=μm band.  相似文献   

16.
New laser lines have been generated using methanol when isotopically labelled CO2 is used in the pump laser. 19 lines have been found when13C16O2 is used and 29 when12C18O2 is used. The wavelengths of the emission lines have been measured with a relative accuracy of 5×10–3 using the submillimetre resonator as a scanning Fabry-Perot interferometer, and the polarizations of the lines have also been measured. Some of the laser lines have been assigned to pure rotational transitions in the excited state associated with the CO stretching mode, other lines are believed to originate from pumping in combination bands.  相似文献   

17.
CO2, CH4, and N2O are recognised as the most important greenhouse gases, the concentrations of which increase rapidly through human activities. Space-borne integrated path differential absorption lidar allows global observations at day and night over land and water surfaces in all climates. In this study we investigate potential sources of measurement errors and compare them with the scientific requirements. Our simulations reveal that moderate-size instruments in terms of telescope aperture (0.5–1.5 m) and laser average power (0.4–4 W) potentially have a low random error of the greenhouse gas column which is 0.2% for CO2 and 0.4% for CH4 for soundings at 1.6 μm, 0.4% for CO2 at 2.1 μm, 0.6% for CH4 at 2.3 μm, and 0.3% for N2O at 3.9 μm. Coherent detection instruments are generally limited by speckle noise, while direct detection instruments suffer from high detector noise using current technology. The wavelength selection in the vicinity of the absorption line is critical as it controls the height region of highest sensitivity, the temperature cross-sensitivity, and the demands on frequency stability. For CO2, an error budget of 0.08% is derived from our analysis of the sources of systematic errors. Among them, the frequency stability of ± 0.3 MHz for the laser transmitter and spectral purity of 99.9% in conjunction with a narrow-band spectral filter of 1 GHz (FWHM) are identified to be challenging instrument requirements for a direct detection CO2 system operating at 1.6 μm. PACS 42.68.Wt; 95.75.Qr  相似文献   

18.
We present the first photoacoustic spectrometer for gas sensing employing both the fundamental and the frequency-doubled radiation of a continuously tunable high-pressure CO2 laser with room temperature operation. A quasi-phase-matched diffusion-bonded GaAs crystal is used in the system for second-harmonic generation. A pulsed photoacoustic detection scheme with a non-resonant cell, equipped with an 80-microphone array, is employed. The wide continuous tuning range in the fundamental (9.2–10.7 μm) and the frequency-doubled (4.6–5.35 μm) regimes, together with the narrow linewidth of 540 MHz (0.018 cm-1) for the 10-μm region and of 1050 MHz (0.0315 cm-1) for the 5-μm region, allow the measurement of gas mixtures, individual species and isotope discrimination. This is illustrated with measurements on NO and CO2. The measured isotope ratio 15 NO/14 NO=(3.58±0.55)×10-3 agrees well with the literature (3.700×10-3) and demonstrates the good selectivity of the system. Received: 30 April 2002 / Revised version: 10 June 2002 / Published online: 2 September 2002 RID="*" ID="*"Corresponding author. Fax: +41-1/633-1077, E-mail: sigrist@iqe.phys.ethz.ch  相似文献   

19.
The isotope-selective multiphoton dissociation of CHClF2 in a multipass refocusing Herriott cell was used to enrich more than 4 moles of chlorodifluoromethane to 99.99% of12C isotopic purity. It is the largest isotope quantity ever separated by a laser process. A cw excited mechanically Q-switched CO2 laser, which delivers 16 mJ pulses at 5 kHz was used. The enrichment controlled by a mass-spectrometer and guided by a PC was run with a rate of 25 g12C per 24 h.  相似文献   

20.
The Er:YAG and the CO2 laser are competitors in the field of hard tissue ablation. The use of Er:YAG lasers (2.94 μm, pulse length L of 100 to 200 μs) show smaller areas of thermal defects then ‘‘superpulsed’’ CO2 lasers with pulse lengths of approximately 100 μs. Only the development of a Q-switched CO2 laser (9.6 μm, τL=250 ns) allowed for similar results. In this paper new results for the Er:YAG and the Q-switched CO2 laser under the influence of water spray will be presented. Several parameters are of special interest for these investigations: the specific ablation energy, which shows a minimum for the CO2 laser at an energy density of 9 J/cm 2 and a broad shallow minimum in the range of 10 to 70 J/cm2 for the Er:YAG laser, and comparison of the cut-shape and depth. Surface effects and cutting velocity are discussed based on SEM pictures. Received: 19 July 2000 / Revised version: 1 November 2000 / Published online: 30 November 2000  相似文献   