1.
Mao Y  Zhang X 《Electrophoresis》2003,24(18):3289-3295
A comprehensive two-dimensional (2-D) separation system, coupling capillary reverse-phase liquid chromatography (cRPLC) to capillary isoelectric focusing (CIEF), is described for protein and peptide mapping. cRPLC, the first dimension, provided high-resolution separations for salt-free proteins. CIEF, the second dimension with an orthogonal mechanism to cRPLC afforded excellent resolution capability for proteins with efficient protein enrichment. Since all sample fractions in cRPLC effluents could be transferred to the CIEF dimensions, the combination of the two high-efficiency separations resulted in maximal separation capabilities of each dimension. Separation effectiveness of this approach was demonstrated using complex protein/peptide samples, such as yeast cytosol and a BSA tryptic digest. A peak capacity of more than 10 000 had been achieved. A laser-induced fluorescence (LIF) detector, developed for this system, allowed for high-sensitive detection, with a fmol level of peptide detection for the BSA digest. FITC and BODIPY maleimide were used to tag the proteins, and the latter was found better both for separation and detection in our 2-D system.  相似文献   

2.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

3.
A 2-D separation platform was constructed using micro strong cation-exchange liquid chromatography (μ-SCXLC) and reversed-phase pressurized capillary electrochromatography (RP-pCEC) for the analysis of complex samples. Samples were fractionated by the first-dimension μ-SCXLC with a linear solvent gradient and then injected into the second-dimension RP-pCEC for further separation. The μ-SCXLC/RP-pCEC 2-D system with three separation mechanisms, namely strong cation-exchange, reversed-phase chromatography and electrophoresis, provided high selectivity, high resolution and high peak capacity compared to one-dimensional chromatographic approaches. Separation effectiveness of this 2-D system was demonstrated by the analysis of different kinds of complex samples, such as traditional Chinese medicine Cortex Phellodendri, bovine serum albumin (BSA) tryptic digest and real serum tryptic digest. A theoretical peak capacity of approximately 1200 was achieved, which proves its promising potential for the separation and analysis of complex samples.  相似文献   

4.
High-efficiency capillary isoelectric focusing (cIEF) separations of protein complexes obtained from soluble protein fractions are demonstrated. Size-exclusion chromatography was used as a first dimension separation to fractionate putative protein complexes with apparent molecular masses of up to 1,500,000 from an Escherichia coli cytosolic fraction. Non-denaturing cIEF separations using highly hydrophilic polymer-coated capillaries constituted the second dimension. The conditions developed produced reproducible and high-efficiency separations, corresponding to approximately 2 x 10(6) theoretical plates and peak capacities of approximately 10(3) for pH 3-10 cIEF separations in 65 cm long capillaries. Combination of the two non-denaturing separation dimensions permitted isolation and analysis of individual protein complexes from complicated biological samples. Studies indicated that many E. coli complexes were stable on the time scale of the cIEF separations, but were degraded upon more extended periods of storage on ice, necessitating rapid sample processing and fast analysis techniques.  相似文献   

5.
魏娟  谷雪  王彦  阎超 《分析化学》2011,39(2):188-192
以毛细管等电聚焦(cIEF)为第一维分离模式,以反相加压毛细管电色谱(pCEC)为第二维分离模式,开展离线二维色谱分离研究,并对复杂肽段进行分离.羟丙基纤维紊(HPC)涂层的毛细管用于cIEF分离,对6种标准蛋白质的平均分离柱效约为31万.在毛细管末端引进电隔离槽,方便了第一维样品的收集.在加电6 kV下,第二维pCE...  相似文献   

6.
Capillary isoelectric focusing (cIEF) with whole column imaging detection (WCID) was explored for the characterization of bovine serum albumin (BSA)-tryptophan interaction, to further understand protein-drug interactions. The BSA-tryptophan interaction was dynamically monitored by cIEF-WCID, to provide the cIEF profiles of the BSA-tryptophan interaction system at different focusing times. Our study demonstrated that the cIEF behavior of BSA can serve as a probe into the study of BSA-tryptophan interaction, through monitoring the change in its cIEF profile when the interaction occurred. The study illustrated that the BSA peak split due to the BSA-tryptophan interaction, and the peak of BSA-tryptophan complex was clearly identified in the cIEF electropherograms. By comparing the cIEF profiles of BSA/L-tryptophan and BSA/D-tryptophan, respectively, our study demonstrated that BSA interacted with the enantiomers of tryptophan with a chiral recognition. L-Tryptophan demonstrated a very strong interaction with BSA, while D-tryptophan exhibited a much weaker interaction with BSA. The effects of the BSA concentration, the tryptophan concentration, the focusing time and the incubation time on the BSA-tryptophan interaction were investigated. This study offers a novel approach for the study of protein-drug interactions.  相似文献   

7.
Jia L  Tanaka N  Terabe S 《Electrophoresis》2005,26(18):3468-3478
A two-dimensional (2-D) separation system of coupling chromatography to electrophoresis was developed for profiling Escherichia coli metabolites. Capillary liquid chromatography (LC) with a monolithic silica-octadecyl silica column (500 x 0.2 mm ID) was used as the first dimension, from which the effluent fractions were further analyzed by capillary electrophoresis (CE) acting as the second dimension. Field-enhanced stacking was selectively employed as a concentration strategy to interface the two dimensions, which proved to be beneficial for the detection of metabolites. An artificial sample containing 118 standards, some of which lack chromophores or have weak UV absorbance, was used to optimize the 2-D separation system. Under the optimum conditions, 63 components in the artificial sample having absorbance at 254 nm could be well resolved and detected. The utility of the system was demonstrated by comprehensive analysis of E. coli metabolites. Comparing with the previous 2-D separation system we published in Anal. Chem. 2004, 76, 1419-1428, using a longer monolithic column in the first dimension improved the separation efficiency and offered the possibility of increasing the injection volume without compromising the separation efficiency. In the second dimension, field-enhanced stacking was used to improve the concentration sensitivity of the metabolites, and more metabolites in E. coli cell extract were detected and identified using the developed 2-D separation system. In addition, preliminary investigation for future CE-mass spectrometry coupling was also made in the study by using volatile buffers in the capillary LC and CE techniques.  相似文献   

8.
The non-availability of commercial carrier ampholytes in the pH range greater than 11 has contributed to difficulties in focusing and resolving highly basic proteins/peptides using capillary isoelectric focusing (cIEF). Two different approaches, involving the use of N,N,N',N'-tetramethylethylenediamine (TEMED) and ampholyte 9-11, are investigated for their effects on the extension of separation range in cIEF. The addition of TEMED into pharmalyte 3-10 not only prevents the peptides/proteins from focusing in sections of the capillary beyond the detection point, but also extends the separation range to at least isoelectric point (pI) 12. The combination of ampholyte 9-11 with pharmalyte 3-10 surprisingly provides baseline resolution between bradykinin (pI 12) and cytochrome c (pI 10.3). The sample mixture, containing bradykinin, the high-pI protein calibration kit (pI 5.2-10.3), and cytochrome c digest, is employed to demonstrate the cIEF separation of proteins and peptides over a wide pH range of 3.7-12.  相似文献   

9.
A pressurized electrochromatography (pCEC) instrument with gradient capability was used in this work for separation of peptides. Three separation modes, namely, pCEC, high-performance liquid chromatography and capillary electrophoresiscan be carried out with the instrument. In pCEC mode, the mobile phase is driven by both electroosmotic flow and pressurized flow, facilitating fine-tuning in selectivity of neutral and charged species. A continuous gradient elution can be carried out conveniently on this instrument, which demonstrates that it is more powerful than isocratic pCEC for separation of complicated samples. The effects of applied voltage, supplementary pressure and ion-pairing agents on separation of peptides in gradient pCEC were investigated. The effects of flow-rate of the pump and the volume of the mixer on resolution were also evaluated.  相似文献   

10.
张政  唐涛  杨三东  孙元社  李彤  张维冰 《色谱》2017,35(5):526-532
基于蛋白质的尺寸及带电性质,将凝胶过滤色谱(GFC)与离子交换色谱(IEC)两种分离模式结合,采用双捕集柱接口构建了GFC/2×IEC二维液相色谱(2-D LC)分离系统,同时考虑离子交换色谱分离蛋白质对等电点范围的限制,进一步结合中心切割平行柱的方法实现对蛋白质的全二维分离。为与后续蛋白质在线酶解、多肽分离及质谱鉴定匹配,系统中采用常规柱以保证蛋白质质谱鉴定对样品量的要求,3种常规分离柱分别选用凝胶过滤色谱柱TSK-GEL G3000SW_(XL)(300 mm×7.8 mm,5μm)、强阴离子交换色谱柱Hypersil SAX(100 mm×4.6 mm,10μm)和强阳离子交换色谱柱Hypersil SCX(100 mm×4.6 mm,10μm)。最终以酵母细胞蛋白质提取液为样品,对构建的二维系统加以评价,在总蛋白质浓度13.5 mg/mL、上样体积100μL的条件下,将第一维分离等时间切割17次,并将切割馏分全部导入第二维继续分离,二维系统在148 min内获得的总峰容量达到884。说明所构建的系统可以用于蛋白质的在线全二维分离。  相似文献   

11.
A mixture of unsaturated fatty acid methyl esters was separated with a new splitless capillary set-up. With the employed apparatus configuration different capillary separation techniques such as capillary high-performance liquid chromatography (cHPLC), capillary electrochromatography (CEC) and pressurized capillary electrochromatography (pCEC) could be applied. The detection and identification of the sample compounds were accomplished by hyphenating these capillary separation techniques with nuclear magnetic resonance (NMR) spectroscopy using a novel configuration of the detection capillary set-up. Using modified electrokinetically driven separation techniques, the electric field was applied solely across the separation column. With this improved interface for capillary liquid chromatography-NMR on-line coupling, the stereochemical assignment of the cis and trans configuration of unsaturated fatty acids could be easily accomplished. Finally, the results of cHPLC-NMR, CEC-NMR and pCEC-NMR coupling experiments were compared.Dedicated to Professor Günter Häfelinger on the occasion of his 65th birthday  相似文献   

12.
李笃信  魏远隆  宋伦  李彤  杜一平  张维冰 《化学学报》2009,67(21):2481-2485
在二维液相色谱中, 第二维的分离速度是制约其发展的重要因素. 升高色谱柱温度可以有效降低流动相粘度, 加快溶质在两相间的传质速率, 有效加快分析速度. 以离子交换色谱法(WAX)为第一维分离模式和反相色谱法(RP)为第二维分离模式, 十通阀和两个捕集柱为接口, 通过将第二维色谱柱温度升高到80 ℃和提高流量到3 mL/min, 构建了高温WAX/RP二维液相色谱系统. 以4种标准蛋白的酶解物为样品评价系统的分离性能, 第一维共有33个馏分被捕集并导入到第二维分析, 高温二维液相色谱系统识别出187个色谱峰.  相似文献   

13.
The influence of several operation conditions on separation of recombinant human erythropoietin glycoforms by capillary isoelectric focusing (cIEF) is explored. From this study it is deduced that in order to separate several glycoforms of erythropoietin, urea has to be added to sample, which should not be completely depleted of the excipients used in its formulation. On-line desalting does not provide separation enhancement for samples with high content of salt. Better resolution is obtained using a mixture of a broad and a narrow pH-range carrier ampholytes than with either one used separately. Under the experimental conditions, focusing voltages of 25 kV improve separation compared to lower and higher electric fields. Focusing times shorter than the time necessary for electric current to reach a minimum provide similar separations than longer focusing times at which a minimum value of the current has already been achieved. The optimized method allows the separation and quantitation in 12 min of at least seven bands containing glycoforms of recombinant erythropoietin with apparent isoelectric points in the range 3.78–4.69. Compared to flat-bed isoelectric focusing, cIEF provides better separation of bands of glycoforms in a shorter time, and allows quantitative determination. Capillary zone electrophoresis (CZE) gives rise to resolution of erythropoietin glycoforms similar to that obtained by cIEF. Although CZE requires a longer analysis time, its reproducibility in terms of peak area of glycoforms is better than in cIEF.  相似文献   

14.
We examined the use of monolithic capillary columns prepared via ring-opening metathesis polymerization (ROMP) for peptide separation in voltage-assisted capillary LC (voltage-assisted CLC). In order to demonstrate their potential for peptide separation, ROMP-derived monoliths with RP properties were prepared. The preparation procedure of monoliths was transferred from ROMP monoliths optimized for CLC. ROMP monoliths were synthesized within the confines of 200 microm id fused-silica capillaries with a length of 37 cm. After optimization of the chromatographic conditions, the separation performance was tested using a well-defined set of artificial peptides as well as two peptidic mixtures resulting from a tryptic digest of BSA as well as a collagenase digest of collagen. ROMP monoliths showed comparable performance to other monolithic separation media in voltage-assisted CLC published so far. Therefore, we conclude that by optimizing the composition of the ROMP monoliths as well as by using the controlled manner of their functionalization, ROMP monoliths bear a great potential in CLC and CEC.  相似文献   

15.
Capillary isoelectric focusing (cIEF) was online coupled to a Q‐TOF MS by a flow‐through microvial interface for the analysis of therapeutic mAb. Intact molecular weights obtained from the mass spectrum deconvolution of separated charge variants provided information on the structural heterogeneity of therapeutic mAbs. A sandwich cIEF–MS configuration composed of anolyte, sample, and catholyte segments sequentially injected into a neutrally coated capillary was used for the charge heterogeneity separation of four mAbs. Acetic acid and ammonium hydroxide were used in places of the non‐volatile acids and bases commonly used for IEF but are incompatible with online MS detection. Glycerol was added as the anti‐convective reagent. A chemical modifier was mixed with the cIEF effluent in the flow‐throw microvial to maintain the ESI stability and to mitigate ion suppression from the co‐eluted carrier ampholytes and glycerol. Analysis of mAb samples have shown relative populations of two basic variants originating from C‐terminal lysine process and acidic variant of deamidation. The lysine clippings, deamidation, and sialic acid modification in oligosaccharide chains were revealed in infliximab. Two lysine clipping variants and a deamidated variant were observed in adalimumab. The duplicate analyses of a reference mAb demonstrated five charge variants separated by cIEF due to some unidentified modifications, as their mass spectra shared close similarities. The mAb analyses demonstrated the feasibility of the cIEF–MS method, and they demonstrated how charge and structural variants and minor differences in therapeutic mAbs are observed with this technology. Online cIEF–MS is an information rich technology with high throughput, demonstrated by the initial data presented here.  相似文献   

16.
Chen J  Lee CS  Shen Y  Smith RD  Baehrecke EH 《Electrophoresis》2002,23(18):3143-3148
On-line combination of capillary isoelectric focusing (CIEF) with capillary reversed-phase liquid chromatography (CRPLC) is developed using a microinjector as the interface for performing two-dimensional (2-D) protein/peptide separations of complex protein mixtures. The focusing effect of CIEF not only contributes to a high-resolution protein/peptide separation, but also may permit the analysis of low-abundance proteins with a typical concentration factor of 50-100 times. The preparative capabilities of CIEF are much larger than most of capillary-based electrokinetic separation techniques since the entire capillary is initially filled with a solution containing proteins/peptides and carrier ampholytes for the creation of a pH gradient inside the capillary. The focused peptides which have a similar pI are coinjected into the second separation dimension and further resolved by their differences in hydrophobicity. The resolving power of combined CIEF-CRPLC system is demonstrated using the soluble fraction of Drosophila salivary glands taken from a period beginning before steroid-triggered programmed cell death and extending to its completion. The separation mechanisms of CIEF and CRPLC are completely orthogonal and the overall peak capacity is estimated to be around approximately 1800 over a run time of less than 8 h. Significant enhancement in the separation peak capacity can be realized by further increasing the number of CIEF fractions and/or slowing the solvent gradient in CRPLC, however, at the expense of overall analysis time. The results of our preliminary studies display significant differences in the separation profiles of peptide samples obtained from salivary glands of animals staged at the 6 and 12 h following puparium formation.  相似文献   

17.
毛细管电色谱和加压毛细管电色谱的进展与应用   总被引:2,自引:1,他引:1  
毛细管电色谱(CEC)以内含色谱固定相的毛细管为分离柱,以电渗流为驱动力,既可以分离带电物质也可以分离中性物质。它结合了毛细管电泳和高效液相色谱两者的优点,兼具高柱效、高分辨率、高选择性和高峰容量的特点,同时具有色谱和电泳的双重分离机理。然而,“纯粹”的电色谱在实际应用中有着天然的弱点,即: 在电流通过毛细管柱中的流动相时容易产生气泡(焦耳热作用),从而使电流中断和电渗流停止,毛细管柱必须被重新用流动相润湿后方能再次使用。加压毛细管电色谱(pCEC)将液相色谱中的压力流引入CEC系统中,不仅解决了气泡、干柱等问题,而且实现了定量阀进样和二元梯度洗脱。CEC和pCEC作为微分离领域的两种前沿技术,满足了当前复杂样品分析和分析仪器微型化的需求,近年来获得了广泛的关注。本文综述了这两种技术近来的发展,包括仪器、色谱固定相的发展,总结了其在生命科学、药物分析、食品安全以及环保样品分析等方面的应用进展,评述了各方法的特点,并展望了CEC和pCEC今后的发展和应用前景。  相似文献   

18.
Poggel M  Melin T 《Electrophoresis》2001,22(6):1008-1015
Different continuously working free-flow zone electrophoresis (FFZE) chambers have already been developed [1, 2]. All of them deal with the problem of distinctive Joule heating. The resulting temperature gradients cause an unstable density field which leads to thermal convection and thus to an intermixing of the different fractions within the chamber. The most promising and simple approach to stabilize the flow is to build chambers with one very small dimension (e.g., h = 0.5 mm) to assure efficient heat withdrawal. This in turn presents substantial disadvantages, namely limited throughput and restricted scale-up potential. The novel approach combines a simplified design and assembly with the possibility of straightforward scale-up. It still operates with one small dimension (d = 1-2 mm) to handle the Joule heating. Here, however, not the dimension perpendicular to the electric field but the dimension parallel to the electric field (separation distance) is chosen as the smallest dimension. The efficiency of the new device is shown by the separation of bovine serum albumin (BSA) and cytochrome c with an overall protein throughput of up to 1.1 g/h, using a cell with a separation volume of less than 20 mL.  相似文献   

19.
Six amino acids with pIs that ranged from 3.2 to 9.7 were used as ampholytes to establish a pH gradient in capillary isoelectric focusing. This amino acid-based capillary isoelectric focusing (cIEF) was coupled with ESI-MS/MS using an electrokinetically pumped sheath-flow interface for peptide analysis. Amino acid-based isoelectric focusing generates a two-order of magnitude lower background signal than commercial ampholytes in the important m/z range of 300–1800. Good focusing was achieved for insulin receptor, which produced ∼10 s peak width. For 0.1 mg mL−1 bovine serum albumin (BSA) digests, 24 ± 1 peptides (sequence coverage 47 ± 4%) were identified in triplicate analysis. As expected, the BSA peptides were separated according to their pI. The concentration detection limit for the BSA digests is 7 nM and the mass detection limit is 7 fmole. A solution of six bovine protein tryptic digests spanning 5 orders of magnitude in concentration was analyzed by amino acid based cIEF-ESI-MS/MS. Five proteins with a concentration range spanning 4 orders of magnitude were identified in triplicate runs. Using amino acid based cIEF-ESI-MS/MS, 112 protein groups and 303 unique peptides were identified in triplicate runs of a RAW 264.7 cell homogenate protein digest. In comparison with ampholyte based cIEF-ESI-MS/MS, amino acid based cIEF-ESI-MS/MS produces higher resolution of five acidic peptides, much cleaner mass spectra, and higher protein spectral counts.  相似文献   

20.
A system enabling coupling of pressurized capillary electrochromatography (pCEC) with off-column amperometric detection (AD) is reported in which conduction of the current in pCEC was achieved through a cellulose acetate-coated porous polymer joint, and the effect of the high-voltage field applied to pCEC for AD was also eliminated. Effects of supplementary pressure on the porous polymer joint and the effects on AD of capillary columns of different i.d. were investigated. The performance of the pCEC–AD system with the porous polymer joint was evaluated with phenol and hydroquinone using sulfonated stearyl methacrylate monolithic columns. The separation efficiency of the column in pCEC–AD, using the proposed off-column detection with the cellulose acetate membrane joint, was comparable with that of pCEC–UV using on-column detection. Compared with end-column detection using a 50 μm i.d. capillary column without a joint, a higher signal-to-noise ratio was achieved, even using a 100 μm i.d. capillary column with a joint. Successful separation and detection of dopamine and epinephrine were also achieved by use of this system.  相似文献   