毛细管电色谱和加压毛细管电色谱的进展与应用 总被引:1,自引:1,他引:1
毛细管电色谱(CEC)以内含色谱固定相的毛细管为分离柱,以电渗流为驱动力,既可以分离带电物质也可以分离中性物质。它结合了毛细管电泳和高效液相色谱两者的优点,兼具高柱效、高分辨率、高选择性和高峰容量的特点,同时具有色谱和电泳的双重分离机理。然而,“纯粹”的电色谱在实际应用中有着天然的弱点,即: 在电流通过毛细管柱中的流动相时容易产生气泡(焦耳热作用),从而使电流中断和电渗流停止,毛细管柱必须被重新用流动相润湿后方能再次使用。加压毛细管电色谱(pCEC)将液相色谱中的压力流引入CEC系统中,不仅解决了气泡、干柱等问题,而且实现了定量阀进样和二元梯度洗脱。CEC和pCEC作为微分离领域的两种前沿技术,满足了当前复杂样品分析和分析仪器微型化的需求,近年来获得了广泛的关注。本文综述了这两种技术近来的发展,包括仪器、色谱固定相的发展,总结了其在生命科学、药物分析、食品安全以及环保样品分析等方面的应用进展,评述了各方法的特点,并展望了CEC和pCEC今后的发展和应用前景。 相似文献
3.
A novel on-line 2-D system was developed for peptide and protein mapping. The system combines capillary IEF (cIEF) with pressurized CEC (pCEC) using a micro-injection valve as the interface. Sample fractions, which were focused and separated in the first-dimension cIEF based on their differences in pIs, were electrically mobilized and further successively resolved by their differences in size, hydrophobicity, and electrophoretic mobility in the second-dimension pCEC. In the presented system, the valve interface was free of the external electric field in two dimensions for the purpose of stabilization, safety, and facilitating manipulation. In the first dimension, cIEF separation was executed by a one-step method to simplify the operation procedure. Moreover, a home-made electrical decoupler was introduced to isolate the micro-injection valve from the cIEF electric field. For the second dimension, taking advantage of the combination of hydrodynamic flow with EOF, reversed-phase pCEC not only offers on-column refocusing the effluent fractions, but also brings enhanced separation resolution and elution speed. Separation effectiveness of this 2-D system was demonstrated by the analysis of tryptic digest of BSA and human red blood cell lysate. A theoretical peak capacity of approximately 24,000 has been achieved for BSA digest, which proves its promising potential for the application in proteomics. 相似文献
4.
Scriba GK 《Electrophoresis》2003,24(15):2409-2421
Capillary electrophoresis is often considered an ideal method for the chiral analysis of compounds due to the high separation power of the technique and has therefore found widespread acceptance for the analysis of drugs and pharmaceuticals. In contrast, capillary electrochromatography is still more or less in an infancy state searching for its place among the analytical separation techniques although interesting applications have been published. The present review summarizes recent developments and applications of chiral pharmaceutical analysis by electromigration techniques published in 2002 and early 2003. 相似文献
5.
In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed. 相似文献
6.
Emil Paleček Viktor Brabec František Jelen Zdeněk Pechan 《Journal of Electroanalytical Chemistry》1977,75(2):471-485
Nucleic acids and proteins were studied by means of derivative and normal pulse polarography, and d.c. and a.c. polarography in connection with the dropping mercury electrode. It was shown that natural ribonucleic acids, as transfer, ribosomal and viral RNAs yield derivative pulse-polarographic peaks; from their heights and potentials conclusions can be made about their content of ordered structure in solution, similarly as in the case of deoxyribonucleic acids studied earlier. Synthetic single-stranded polyribo-cytidylic acid yields a well developed peak, whereas in the double-helical complex with polyriboguanylie acid it is inactive when using either derivative pulse polarography or d.c. polarography. Well developed peaks were obtained also with albumin (a protein containing reducible?S?S? groups), while only an inflex was observed on the d.c. polarogram. Proteins were also studied in media containing cobalt (Brdi?ka's solution) or nickel and it was shown that derivative pulse polarography due to its high sensitivity and accuracy enables us to carry out the measurements even in less common media than Brdi?ka's solution. This fact could be exploited in clinical chemistry as well as in the investigation of the nature of catalytic currents of proteins. The currents of double-helical polynucleotides obtained by means of normal pulse polarography exhibit a marked dependence on the initial potential and cannot represent a reliable indicator of structural changes of biopolymers in solution. They can however, be used in studies of the influence of the polynucleotide adsorption at different potentials on the subsequent reduction. 相似文献
7.
8.
9.
In this article, the effects of the stationary phase, buffer pH, organic modifier type, organic modifier composition, applied voltage, and temperature on the migration of several synthetic peptides in etched chemically modified open-tubular capillaries are discussed. With these solutes, migration is due to two effects: electrophoretic mobility and solute/bonded phase interactions. In addition, relative migration rates are evaluated for the peptide samples as a function of these experimental variables in order to determine which parameters might be useful for optimizing separations in open-tubular capillary electrochromatography (OTCEC). Some examples of synthetic peptide separations are presented where the sample contains a major component and several minor species, demonstrating how the resolution of these mixtures can be affected by the appropriate choice of experimental variables. 相似文献
10.
Rapp E Jakob A Schefer AB Bayer E Albert K 《Analytical and bioanalytical chemistry》2003,376(7):1053-1061
A mixture of unsaturated fatty acid methyl esters was separated with a new splitless capillary set-up. With the employed apparatus configuration different capillary separation techniques such as capillary high-performance liquid chromatography (cHPLC), capillary electrochromatography (CEC) and pressurized capillary electrochromatography (pCEC) could be applied. The detection and identification of the sample compounds were accomplished by hyphenating these capillary separation techniques with nuclear magnetic resonance (NMR) spectroscopy using a novel configuration of the detection capillary set-up. Using modified electrokinetically driven separation techniques, the electric field was applied solely across the separation column. With this improved interface for capillary liquid chromatography-NMR on-line coupling, the stereochemical assignment of the cis and trans configuration of unsaturated fatty acids could be easily accomplished. Finally, the results of cHPLC-NMR, CEC-NMR and pCEC-NMR coupling experiments were compared.Dedicated to Professor Günter Häfelinger on the occasion of his 65th birthday 相似文献
11.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method. 相似文献
12.
以N,N-二甲基-N-甲基丙烯酰胺基丙基-N,N-二甲基-N-丙烷磺酸内盐(SPP)为单体,季戊四醇三丙烯酸酯(PETA)为交联剂,偶氮二异丁腈(AIBN)为引发剂及两类不同的致孔剂(乙醇/乙二醇和甲醇/1,4-丁二醇)制备了两种新型亲水性整体柱。为了获得理想的柱效、电渗流速度和渗透性,对制备整体柱的各反应物配比进行了研究和优化。比较了两种整体柱在渗透性和分离样品方面的性能,结果表明,以乙醇/乙二醇为致孔剂制备的整体柱在柱效、分离度方面优于以甲醇/1,4-丁二醇为致孔剂制备的整体柱,但在渗透性方面不及后者。探讨了流动相中盐浓度对核苷类样品保留的影响,发现当甲酸铵浓度从10 mmol/L增加到70 mmol/L时,核苷样品的保留因子呈现先增加后减小的状态。将制备的整体柱用于毛细管液相色谱和加压电色谱分别分离胺类、酚类和核苷类样品,获得了理想的分离效果。在分离酚类和核苷类混合样品时,发现加压毛细管电色谱在分离度和分离速度上均优于毛细管液相色谱。 相似文献
13.
A novel open tubular (OT) column covalently modified with hydrophilic polysaccharide, carboxymethylchitosan (CMC) as stationary phase has been developed, and employed for the separations of basic proteins and opium alkaloids by capillary electrochromatography (CEC). With the procedures including the silanization of 3-aminopropyltrimethoxysilane (APTS) and the combination of glutaraldehyde with amino-silylated silica surface and CMC, CMC was covalently bonded on the capillary inner wall and exhibited a remarkable tolerance and chemical stability against 0.1 mol/L HCl, 0.1 mol/L NaOH or some organic solvents. By varying the pH values of running buffer, a cathodic or anodic EOF could be gained in CMC modified column. With anodic EOF mode (pH<4.3), favorable separations of basic proteins (trypsin, ribonuclease A, lysozyme and cytochrome C) were successfully achieved with high column efficiencies ranging from 97,000 to 182,000 plates/m, and the undesired adsorptions of basic proteins on the inter-wall of capillary could be avoided. Good repeatability was gained with RSD of the migration time less than 1.3% for run-to-run (n=5) and less than 3.2% for day-to-day (n=3), RSD of peak area was less than 5.6% for run-to-run (n=5) and less than 8.8% for day-to-day (n=3). With cathodic EOF mode (pH>4.3), four opium alkaloids were also baseline separated in phosphate buffer (50 mmol/L, pH 6.0) with column efficiencies ranging from 92,000 to 132,000 plates/m. CMC-bonded OT capillary column might be used as an alternative medium for the further analysis of basic proteins and alkaline analytes. 相似文献
14.
A weak anion-exchange type chiral stationary phase (CSP) based on tert.-butylcarbamoylquinine as chiral selector and silica as chromatographic support was applied to non-aqueous capillary electrochromatography. The mobile phases used consisted of acetonitrile and methanol as organic solvents, and acetic acid and triethylamine were added as background electrolytes. The influence of several experimental parameters (electrolyte concentration, acetic acid-triethylamine ratio, acetonitrile-methanol ratio and temperature) was evaluated in order to obtain improved enantioselectivity and efficiency as well as short run times for the enantiomeric separation of negatively charged chiral analytes including benzyloxycarbonyl, N-(3,5-dinitrobenzyloxycarbonyl, 9-fluorenylmethoxycarbonyl, benzoyl, acetyl and N-(2,4-dinitrophenyl) derivatized amino acids and profens. Solvent composition of acetonitrile-methanol (80:20) and enhanced electrolyte concentrations up to 600 mM acetic acid at a constant acid-base ratio of 100:1 with high applied voltages of -25 kV proved to be optimum regarding short retention times and improved efficiencies. For example, the enantiomers of Fmoc-Leu could be separated in less than 10 min with a resolution factor of 6.9 and about 100000 theoretical plates per meter. 相似文献
15.
Determining the change in topological properties like shape, flexibility and packing of proteins and nucleic acids on complexation is important in characterizing the role of induced structural changes and various interactions which control the functional specificity of proteins and nucleic acids. To this end, we have analyzed and compared the three dimensional structures of several protein-protein, protein-DNA and protein-RNA complexes available in the Protein Data Bank (PDB) and the Nucleic Acid Data Bank (NDB). The size of complexed proteins and nucleic acids, as measured by the radius of gyration, follows Flory's scaling law. The change in the scaling exponents for proteins, RNA and DNA reflects the changes in their respective sizes due to complexation. The anisotropy in the shape of proteins, DNA and RNA in complexes is measured by considering the asphericity and shape parameter, which are calculated from the eigenvalues of the moment of inertia tensor. The distribution of asphericity and shape shows that complexed proteins are mostly spherically symmetrical, while DNA and RNA in complexed states are largely prolate and considerably more aspherical compared to the proteins. Persistence length characterizes the intrinsic flexibility/rigidity of proteins and nucleic acids. The flexibility of all biomolecules decreases with the chain length. For small DNA molecules (6-147 base pairs), persistence length is larger compared to RNA and proteins in protein-protein and protein-RNA complexes. The flexibility of DNA increases, while RNA decreases, in their respective complexed states as compared to that of proteins which remain almost unchanged. The two body contact analysis confirms that the side-chain-backbone contacts are predominant compared to sidechain-sidechain and backbone-backbone contacts in the complexed proteins. The average packing density of proteins decreases in their complexed states, which is measured by the mean value of the contact density of their alpha carbon atoms. The average number of hydrogen bonds are found to be less in the interface region of protein-protein complexes compared to that in protein-DNA and protein-RNA complexes. 相似文献
16.
The use of capillary electrochromatography (CEC) for the separation by isocratic elution of synthetic peptides, proteins as well as the tryptic digest of cytochrome c has been demonstrated. The monolithic porous stationary phase was prepared from silanized fused-silica capillaries of 75 microm I.D. by in situ copolymerization of vinylbenzyl chloride and ethylene glycol dimethacrylate in the presence of propanol and formamide as the porogens. The chloromethyl groups at the surface of the porous monolith were reacted with N,N-dimethylbutylamine to form a positively charged chromatographic surface with fixed n-butyl chains. Results of studies on the influence of temperature and mobile phase composition on the retention and selectivity of separation by CEC demonstrated the feasibility of rapid polypeptide analysis and tryptic mapping at elevated temperature with high resolution and efficiency. Typically the chromatography of a tryptic digest of cytochrome c took about 5 min at 55 degrees C and 75 kV/m with hydro-organic mobile phases containing acetonitrile in 50 mM phosphate buffer, pH 2.5. For peptides and proteins plots of logarithmic k'cec against acetonitrile concentration were nonlinear, whereas Arrhenius plots for the mobilities were nearly linear. Comparison of the separation of such samples under conditions of CEC and capillary zone electrophoresis (CZE) indicates that the mechanism of separation in CEC is unique and leads to a chromatographic profile different from that obtained by CZE. 相似文献
17.
Aurora Cerasi Enrico Millo Maria Francesca OttavianiGianluca Damonte Michela CangiottiUmberto Benatti Laura Chiarantini 《Tetrahedron letters》2003,44(48):8701-8704
A new combined solid-liquid phase synthesis method for a spin labeled peptide nucleic acid (PNA) is developed. The methodology involved initial preparation of a protected PNA on solid phase, followed by efficient solution phase coupling to a spin label containing a reactive carboxylic group. This strategy allows to maintain the integrity of the nitroxide moiety during the various steps of chemical synthesis assuring in the same time the fidelity of the hybridization assay. This compound can be used as a reporter molecule to investigate the binding of peptide nucleic acids to oligonucleotide sequences (DNA or RNA) by EPR spectroscopy. 相似文献
18.
UV- and visible-excited fluorescence detection strategies were compared for nucleic acids separated by capillary electrophoresis (CE). A dual-polymer sieving matrix consisting of hydroxypropylmethylcellulose and poly(vinylpyrrolidone) was used to separate DNA fragments from a 100-base pair ladder and RNA from individual cells. Two nucleic acid dyes, SYBR Gold and SYBR Green I, were evaluated for their performance at both UV (275 nm) and visible (488 nm) excitation wavelengths. While SYBR Gold-bound RNA from single cells yielded a substantially reduced UV-excited signal compared to that with visible excitation (as expected), the sensitivity of SYBR Gold-bound double-stranded DNA was comparable for UV and Vis excitation wavelengths. This study reveals the first demonstration of using SYBR Gold dyes for DNA detection following separation with CE and also the first example of SYBR-based detection of RNA sampled and separated from individual cells. 相似文献
19.
以丙烯酰胺(AM)为单体,八乙烯基倍半硅氧烷(POSS)为交联剂,偶氮二异丁腈(AIBN)为引发剂,四氢呋喃(THF)为致孔剂,通过原位聚合法制备了poly(POSS-co-AM)有机-无机杂化整体柱,并对各反应物的配比进行了优化。结果表明,当功能单体与致孔剂、POSS与AM的质量比均为1.0: 5.0, AIBN的质量分数为0.1%时,杂化整体柱的柱效最高。无机材料的引入使整体柱结构均匀并具有良好的渗透性,该整体柱既能用于亲水色谱模式,也能用于反相色谱模式。将制备的整体柱用于毛细管液相色谱和加压毛细管电色谱分离核苷类、胺类、硝基苯胺类等化合物,获得了良好的效果。 相似文献
20.
A flexible and convenient protocol for the analysis and purification of peptide nucleic acid (PNA) oligomers and PNA-peptide chimeras by denaturing PAGE is described. Vertical slab gel electrophoresis, 26% in polyacrylamide and 8 M urea at pH 3, was suitable for analysis of oligomers ranging in size from tetramers (4-mers) to tetradodecamers (24-mers). Single-base resolution of oligomers was achieved and separations are generally superior to those given by standard RP-HPLC techniques. The separation of a related series of PNA oligomers showed the distance migrated was linearly dependent on the logarithm of the molecular weight. The migration of oligomers through the gel is dependent on the number of basic functional groups present, such as amino groups, and the A and C content of the oligomer. PNAs are amenable to detection by UV-shadowing technique illuminated at 260 nm or Coomassie blue staining, both with similar, sub-microgram per band detection limits. 相似文献