首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Performing localized chemical events on surfaces is critical for numerous applications. We earlier invented the microfluidic probe (MFP), which circumvented the need to process samples in closed microchannels by hydrodynamically confining liquids that performed chemistries on surfaces (Juncker et al. Nat. Mater. 2005, 4, 622-628). Here we present a new and versatile probe, the vertical MFP (vMFP), which operates in the scanning mode while overcoming earlier challenges that limited the practical implementation of the MFP technology. The key component of the vMFP is the head, a microfluidic device (~1 cm(2) in area) consisting of glass and Si and having microfluidic features fabricated in-plane in the Si layer. The base configuration of the head has two micrometer-size channels that inject/aspirate liquids and terminate at the apex which is ~1 mm(2). In scanning mode, the head is oriented vertically with the apex parallel to the surface with typical spacing of 1-30 μm. Such length scales and using flow rates from nanoliters/second to microliters/second allow chemical events to be performed on surfaces with tens of picoliter quantities of reagents. Before scanning, the head is clipped on a holder for leak-free, low dead volume interface assembly, providing a simple world-to-chip interface. Surfaces are scanned by mounting the holder on a computer-controlled stage having ~0.1 μm resolution in positioning. We present detailed steps to fabricate vMFP heads having channels with dimensions from 1 μm × 1 μm to 50 μm × 50 μm for liquid localization over areas of 10-10,000 μm(2). Additionally, advanced design strategies are described to achieve high yield in fabrication and to support a broad range of applications. These include particulate filters, redundant aperture architectures, inclined flow-paths that service apertures, and multiple channels to enable symmetric flow confinement. We also present a method to characterize flow confinement and estimate the distance between the head and the surface by monitoring the evolution of a solution of fluorescently labeled antibody on an activated glass surface. This flow characterization reveals regimes of operation suitable for different surface topographies. We further integrate the dispensing of immersion liquid to the vMFP head for processing surfaces for extended periods of time (~60 min). The versatility of the vMFP is exemplified by patterning fluorescently labeled proteins, inactivation of cells using sodium hypochlorite, and staining living NIH fibroblasts with Cellomics. These applications are enabled by the compact design of the head, which provides easy access to the surface, simplifies alignment, and enables processing surfaces having dimensions from the micrometer to the centimeter scale and with large topographical variations. We therefore believe that ease-of-operation, reconfigurability, and conservative use of chemicals by the vMFP will lead to its widespread use by microtechnologists and the chemical and biomedical communities.  相似文献   

2.
Channel geometry combined with surface chemistry enables a stable liquid boundary flow to be attained along the surfaces of a 12 microm diameter hydrophilic glass fiber in a closed semi-elliptical channel. Surface free energies and triangular corners formed by PDMS/glass fiber or OTS/glass fiber surfaces are shown to be responsible for the experimentally observed wetting phenomena and formation of liquid boundary layers that are 20-50 microm wide and 12 microm high. Viewing this stream through a 20 microm slit results in a virtual optical window with a 5 pL liquid volume suitable for cell counting and pathogen detection. The geometry that leads to the boundary layer is a closed channel that forms triangular corners where glass fiber and the OTS coated glass slide or PDMS touch. The contact angles and surfaces direct positioning of the fluid next to the fiber. Preferential wetting of corner regions initiates the boundary flow, while the elliptical cross-section of the channel stabilizes the microfluidic flow. The Young-Laplace equation, solved using fluid dynamic simulation software, shows contact angles that exceed 105 degrees will direct the aqueous fluid to a boundary layer next to a hydrophilic fiber with a contact angle of 5 degrees. We believe this is the first time that an explanation has been offered for the case of a boundary layer formation in a closed channel directed by a triangular geometry with two hydrophobic wetting edges adjacent to a hydrophilic surface.  相似文献   

3.
We demonstrate a new method for joining thermoplastic surfaces to produce microfluidic devices. The method takes advantage of the sharply defined permeation boundary of case-II diffusion to generate dimensionally controlled, activated bonding layers at the surfaces being joined. The technique is capable of producing bonds that exhibit cohesive failure, while preserving the fidelity of fine features in the bonding interface. This approach is uniquely suited to production of layered microfluidic structures, as it allows the bond-forming interface between plastic parts to be precisely manipulated at micrometre length scales. Distortions in microfluidic device channels are limited to the size scale of the permeant-swollen layer; 6 microm deep channels are routinely produced with no detectable cross-sectional distortions. Conventional thermal diffusion bonding of identical parts yields less strongly bonded microfluidic structures with increasingly severe dimensional compressions as bonding temperatures approach the thermoplastic glass-transition temperature: a preliminary rheological analysis is consistent with the observed compressions. The bond-enhancing procedure is easily integrated in standard process flows, uses inexpensive reagents, and requires no specialized equipment.  相似文献   

4.
We present a capillary flow system for liquid transport in microsystems. Our simple microfluidic system consists of two planar parallel surfaces, separated by spacers. One of the surfaces is entirely hydrophobic, the other mainly hydrophobic, but with hydrophilic pathways defined on it by photolithographic means. By controlling the wetting properties of the surfaces in this manner, the liquid can be confined to certain areas defined by the hydrophilic pathways. This technique eliminates the need for alignment of the two surfaces. Patterned plasma-polymerized hexafluoropropene constitutes the hydrophobic areas, whereas the untreated glass surface constitutes the hydrophilic pathways. We developed a theoretical model of the capillary flow and obtained analytical solutions which are in good agreement with the experimental results. The capillarity-driven microflow system was also used to pattern and immobilize biological material on planar substrates: well-defined 200 microm wide strips of human cells (HeLa) and fluorescence labelled proteins (fluorescein isothiocyanate-labelled bovine serum albumin, i.e., FITC-BSA) were fabricated using the capillary flow system presented here.  相似文献   

5.
The manipulation of electron transfer reactions at surfaces forms the cornerstone of electrodeposition and processing of materials on substrates with precise control of stoichiometry and oxidation state. However, the utility of this technique, which is mainly carried out in liquid electrolytes, is ultimately limited by the electrolysis of the solvent which limits a potential window to at best 4.8 V in nonaqueous solutions (A. J. Bard and L. R. Faulkner, Electrochemical Methods: Fundamentals and Applications, Wiley, New York, NY, 2nd edn, 2001; ref. 1) and can be up to 6 V in ionic liquids (A. P. Abbott, K. J. McKenzie, Phys. Chem. Chem. Phys., 2006, 8, 4265-4279; ref. 2). A long-sought-after goal has been to develop a corresponding technique at the solid/gas interface in the absence of a solvent which will allow in principle a potential window in excess of 100 V (J. M. Goodings, J. Guo, A. N. Hayhurst and S. G. Taylor, Int. J. Mass Spectrom., 2001, 206, 137-151; ref. 3). This extended potential window will enable chemistry at the solid/gas interface that is not possible at the solid/liquid interface. Here we describe a new approach to gas-phase electrochemistry using a flame plasma as the electrolyte medium. We demonstrate the controlled electrochemical reduction of Cu(+) to Cu(0) at an electrode surface in a flame environment with resulting deposition of either Cu(2)O or Cu species on conducting diamond electrodes. This approach is novel in that it involves the application of an electrochemical potential difference to change the redox state of surface confined species, not the measurement of flame bore ions (as in flame ionisation detectors). This new technique will permit deposition of films and particles on surfaces with control over the oxidation state of the species. This will provide a valuable enhancement to the capabilities of materials preparation methods such as flame spray deposition.  相似文献   

6.
H Ding  S Sadeghi  GJ Shah  S Chen  PY Keng  CJ Kim  RM van Dam 《Lab on a chip》2012,12(18):3331-3340
Digital microfluidic chips provide a new platform for manipulating chemicals for multi-step chemical synthesis or assays at the microscale. The organic solvents and reagents needed for these applications are often volatile, sensitive to contamination, and wetting, i.e. have contact angles of <90° even on the highly hydrophobic surfaces (e.g., Teflon? or Cytop?) typically used on digital microfluidic chips. Furthermore, often the applications dictate that the processes are performed in a gas environment, not allowing the use of a filler liquid (e.g., oil). These properties pose challenges for delivering controlled volumes of liquid to the chip. An automated, simple, accurate and reliable method of delivering reagents from sealed, off-chip reservoirs is presented here. This platform overcomes the issues of evaporative losses of volatile solvents, cross-contamination, and flooding of the chip by combining a syringe pump, a simple on-chip liquid detector and a robust interface design. The impedance-based liquid detection requires only minimal added hardware to provide a feedback signal to ensure accurate volumes of volatile solvents are introduced to the chip, independent of time delays between dispensing operations. On-demand dispensing of multiple droplets of acetonitrile, a frequently used but difficult to handle solvent due to its wetting properties and volatility, was demonstrated and used to synthesize the positron emission tomography (PET) probe [(18)F]FDG reliably.  相似文献   

7.
Microfluidics with aqueous two-phase systems   总被引:1,自引:0,他引:1  
Hardt S  Hahn T 《Lab on a chip》2012,12(3):434-442
An overview is given about research activities in which aqueous two phase systems (ATPSs) are utilized in microfluidic setups. ATPSs consist of two immiscible aqueous phases and have traditionally been used for the separation and purification of biological material such as proteins or cells. Microfluidic implementations of such schemes are usually based on a number of co-flowing streams of immiscible phases in a microchannel, thereby replacing the standard batch by flow-through processes. Some aspects of the stability of such flow patterns and the recovery of the phases at the channel exit are reviewed. Furthermore, the diffusive mass transfer and sample partitioning between the phases are discussed, and corresponding applications are highlighted. When diffusion is superposed by an applied electric field normal to the liquid/liquid interface, the transport processes are accelerated, and under specific conditions the interface acts as a size-selective filter for molecules. Finally, the activities involving droplet microflows of ATPSs are reviewed. By either forming ATPS droplets in an organic phase or a droplet of one aqueous phase inside the other, a range of applications has been demonstrated, extending from separation/purification schemes to the patterning of surfaces covered with cells.  相似文献   

8.
This paper presents a simple method to change the hydrophilic nature of the glass surface in a poly(dimethylsiloxane) (PDMS)-glass hybrid microfluidic device to hydrophobic by an extra-heating step during the fabrication process. Glass substrates bonded to a native or oxygen plasma-treated PDMS chip having microchambers (12.5 mm diameter, 110 μm height) were heated at 200°C for 3 h, and then the hydrophobicity of the glass surfaces on the substrate was evaluated by measuring the contact angle of water. By the extra-heating process, the glass surfaces became hydrophobic, and its contact angle was around 109°, which is nearly the same as native PDMS surfaces. To demonstrate the usefulness of this surface modification method, a PDMS-glass hybrid microfluidic device equipped with microcapillary vent structures for pneumatic manipulation of droplets was fabricated. The feasibility of the microcapillary vent structures on the device with the hydrophobic glass surfaces are confirmed in practical use through leakage tests of the vent structures and liquid handling for the electrophoretic separation of DNA molecules.  相似文献   

9.
Wu D  Wu SZ  Chen QD  Zhao S  Zhang H  Jiao J  Piersol JA  Wang JN  Sun HB  Jiang L 《Lab on a chip》2011,11(22):3873-3879
Composition modification and surface microstructures have been widely utilized in interface science to improve the surface performance. In this paper, we observed a significant improvement of oil contact angle (CA) from 66 ± 2° to 120 ± 4° by introducing a radical silanol group on a flat PDMS surface through oxygen plasma pretreatment. By combining surface microstructures and plasma modification, we produced three kinds of superoleophobic surfaces: 20 μm pitch micropillar arrays, 2.5 μm pitch micropillar arrays and gecko foot-like hierarchical microstructures. Among them, the hierarchical surface with high surface roughness showed extreme underwater superoleophobicity, which featured ultrahigh CA (175 ± 3°) and ultrasmall sliding angle (<1°). Quantitative measurements demonstrated that these superoleophobic surfaces exhibited distinct adhesive behaviors, by which they were interpreted as Wenzel's, Cassie's and the Lotus state, respectively. A microfluidic channel with superoleophobic microstructures was further created by novel curve-assisted imprint lithography, and the characterization based on anti-oil contamination applications was carried out and discussed. We believe that the superoleophobic surfaces will power broad applications in oil microdroplet transportation, anti-oil channels and droplet microfluidic systems.  相似文献   

10.
The fabrication of microfluidic channels with complex three-dimensional (3D) geometries presents a major challenge to the field of microfluidics, because conventional lithography methods are mainly limited to rectangular cross-sections. In this paper, we demonstrate the use of mechanical micromachining to fabricate microfluidic channels with complex cross-sectional geometries. Micro-scale milling tools are first used to fabricate semi-circular patterns on planar metallic surfaces to create a master mold. The micromilled pattern is then transferred to polydimethylsiloxane (PDMS) through a two-step reverse molding process. Using these semi-circular PDMS channels, circular cross-sectioned microchannels are created by aligning and adhering two channels face-to-face. Straight and serpentine-shaped microchannels were fabricated, and the channel geometry and precision of the metallic master and PDMS molds were assessed through scanning electron microscopy and non-contact profilometry. Channel functionality was tested by perfusion of liquid through the channels. This work demonstrates that micromachining enabled soft lithography is capable of fabricating non-rectangular cross-section channels for microfluidic applications. We believe that this approach will be important for many fields from biomimetics and vascular engineering to microfabrication and microreactor technologies.  相似文献   

11.
We demonstrate new principles of microfluidic pumping and mixing by electronic components integrated into a microfluidic chip. The miniature diodes embedded into the microchannel walls rectify the voltage induced between their electrodes from an external alternating electric field. The resulting electroosmotic flows, developed in the vicinity of the diode surfaces, were utilized for pumping or mixing of the fluid in the microfluidic channel. The flow velocity of liquid pumped by the diodes facing in the same direction linearly increased with the magnitude of the applied voltage and the pumping direction could be controlled by the pH of the solutions. The transverse flow driven by the localized electroosmotic flux between diodes oriented oppositely on the microchannel was used in microfluidic mixers. The experimental results were interpreted by numerical simulations of the electrohydrodynamic flows. The techniques may be used in novel actively controlled microfluidic-electronic chips.  相似文献   

12.
In microchannel flow, gas-liquid interface behavior is important for developing a wide range of microfluidic applications, especially in passive microfluidic systems. This paper presents a discussion of interface motion driven by capillary action in a microchannel. We have extended the theory beyond the previous theory of capillary rise problem for a circular tube, to a rectangular microchannel. The same formula for the relation between nondimensional time and interface position is obtained as for a circular tube. We examined rectangular microchannels with several sizes (about 50 to 100 microm square) of glass capillaries and 85 x 68 microm and 75 x 45 microm polydimethylsiloxane (PDMS) microchannels fabricated by photolithography technique, respectively. We observed movement of the gas-liquid interface position and compared it to the dimensionless relation. We obtained the value of a dimensionless variable of driving force that is related to dynamic contact angles for glass-water, glass-ethanol, and PDMS-ethanol. Using this variable, interface motion can be predicted for any size of rectangular channels.  相似文献   

13.
We consider theoretically liquid rise against gravity in capillaries with height-dependent cross-sections. For a conical capillary made from a hydrophobic surface and dipped in a liquid reservoir, the equilibrium liquid height depends on the cone-opening angle alpha, the Young-Dupré contact angle theta, the cone radius at the reservoir's level R(0), and the capillary length kappa(-)(1). As alpha is increased from zero, the meniscus' position changes continuously until, when alpha attains a critical value, the meniscus jumps to the bottom of the capillary. For hydrophilic surfaces the meniscus jumps to the top. The same liquid height discontinuity can be achieved with electrowetting with no mechanical motion. Essentially the same behavior is found for two tilted surfaces. We further consider capillaries with periodic radius modulations and find that there are few competing minima for the meniscus location. A transition from one to another can be performed by the use of electrowetting. Finite pressure difference between the two sides of the liquids can be incorporated as well, resulting in complicated phase-diagrams in the alpha-theta plane. The phenomenon discussed here may find uses in microfluidic applications requiring the transport small amounts of water "quanta" (volume < 1 nL) in a regular fashion.  相似文献   

14.
Patel MV  Tovar AR  Lee AP 《Lab on a chip》2012,12(1):139-145
A novel on-chip microfluidic switch is demonstrated that utilizes the acoustic microstreaming generated by an oscillating air-liquid interface to switch cells/particles into bifurcating microchannels. The air-liquid interface of the Lateral Cavity Acoustic Transducers (LCATs) can be actuated by an external acoustic energy source causing the interface to oscillate. The oscillating interface results in the generation of vortex-like microstreaming flow within a localized region of the surrounding liquid. This streaming was utilized here to deflect cells/particles into a collection outlet. It was demonstrated that the switching zone could be controlled by varying the actuation time of the LCAT. An LCAT based microfluidic switch is capable of achieving theoretical switching rates of 800 cells/particles per second. It was also demonstrated that K562 cells could be switched into a collection channel with cell viability comparable to that of controls as determined by Trypan blue exclusion assay.  相似文献   

15.
Fan SK  Yang H  Hsu W 《Lab on a chip》2011,11(2):343-347
We present a long (204 mm), curved (curvature of 0.04 mm(-1)), and closed droplet pathway in "droplet-on-a-wristband" (DOW) with the designed digital microfluidic modular interfaces for electric signal and droplet connections based on the study of electrowetting-on-dielectric (EWOD) in inclined and curved devices. Instead of using sealed and leakage-proof pipes to transmit liquid and pumping pressure, the demonstrated modular interface for electrowetting-driven digital microfluidics provides simply electric and fluidic connections between two adjacent parallel-plate modules which are easy-to-attach/detach, showing the advantages of using droplets for microfluidic connections between modules. With the previously reported digital-to-channel interfaces (Abdelgawad et al., Lab Chip, 2009, 9, 1046-1051), the chip-to-chip interface presented here would be further applied to continuous microfluidics. Droplet pumping across a single top plate gap and through a modular interface with two gaps between overlapping plates are investigated. To ensure the droplet transportation in the DOW, we actuate droplets against gravity in an inclined or curved device fabricated on flexible PET substrates prepared by a special razor blade cutter and low temperature processes. Pumping a 2.5 μl droplet at a speed above 105 mm s(-1) is achieved by sequentially switching the entire 136 driving electrodes (1.5 mm × 1.5 mm) along the four flexible modules of the DOW fabricated by 4-inch wafer facilities.  相似文献   

16.
Organic-aqueous liquid (phenol) extraction is one of many standard techniques to efficiently purify DNA directly from cells. The cell components naturally distribute themselves into the two fluid phases in order to minimize interaction energies of the biological components with the surrounding solvents. The membrane components and protein partition to the interface between the organic and aqueous phases while the DNA stays in the aqueous phase. The aqueous phase is then removed with a purified DNA sample. This work studies the first steps towards miniaturizing this liquid extraction technique in a microfluidic device. The first step is to understand how the two liquid phases behave in microchannels. Due to the interfacial tension between the two liquid phases, novel approaches must be examined in order to obtain interfacial stability under flow conditions. The stability of the organic-aqueous interface is improved by reducing the interfacial tension between the two phases by incorporating a surfactant into the aqueous phase. The variation of the interfacial tension as a function of surfactant concentration is also quantified in this work. This has led to the ability to create stable stratified microflows in both a dual inlet and three inlet microfluidic systems. Also, the first step in understanding biological interactions at the organic-aqueous interface is investigated using a fluorescently labeled bovine serum albumin protein.  相似文献   

17.
We present for the first time an electrowetting on dielectric (EWOD) microfluidic system coupled to a surface-assisted laser desorption-ionization (SALDI) silicon nanowire-based interface for mass spectrometry (MS) analysis of small biomolecules. Here, the transfer of analytes has been achieved on specific locations on the SALDI interface followed by their subsequent mass spectrometry analysis without the use of an organic matrix. To achieve this purpose, a device comprising a digital microfluidic system and a patterned superhydrophobic/superhydrophilic silicon nanowire interface was developed. The digital microfluidic system serves for the displacement of the droplets containing analytes, via an electrowetting actuation, inside the superhydrophilic patterns. The nanostructured silicon interface acts as an inorganic target for matrix-free laser desorption-ionization mass spectrometry analysis of the dried analytes. The proposed device can be easily used to realize several basic operations of a Lab-on-Chip such as analyte displacement and rinsing prior to MS analysis. We have demonstrated that the analysis of low molecular weight compounds (700 m/z) can be achieved with a very high sensitivity (down to 10 fmol μL(-1)).  相似文献   

18.
Using COMSOL multiphysics software and a previously validated 3D numerical model, performances of a novel air-breathing microfluidic fuel cell (MFFC) are discussed. The microfluidic fuel cell employs a simple structure composed of a flow channel with sloped upper wall, a gas diffusion cathode and a finny anode. Furthermore it can reduce the losses related to mixing in fuel-electrolyte interface and also promote the replenishment of the depletion layer on anode surfaces. Thus, high fuel utilization can be achieved. Numerical simulations show that the fuel utilization can be up to 70%.  相似文献   

19.
Young-Teck Kim  Ji Hoon Lee 《Talanta》2009,78(3):998-1507
Based on the principle of liquid core waveguide, a novel microfluidic device with micro-scale detection window capable of sensing flashlight emitted from rapid 1,1′-oxalyldi-4-methylimidazole (OD4MI) chemiluminescence (CL) reaction was fabricated. Light emitted from OD4MI CL reaction occurring in the micro-dimensional pentagonal detection window (length of each line segment: 900.0 μm, depth: 50.0 μm) of the microfluidic device with two inlets and one outlet was so bright that it was possible to take an image every 1/30 s at the optimal focusing distance (60 cm) using a commercial digital camera. Peaks obtained using a flow injection analysis (FIA) system with the micro-scale detection window and OD4MI CL detection show excellent resolution and reproducibility without any band-broadening observed in analytical devices having additional reaction channel(s) to measure light generated from slow CL reaction. Maximum height (Hmax) and area (A) of peak, reproducibility and sensitivity observed in the FIA system with the microfluidic device and OD4MI CL detection depends on (1) the mole ratio between bis(2,4,6-trichlorophenyl) oxalate and 4-methyl imidazole yielding OD4MI, (2) the flow rate to mix OD4MI, H2O2 and 1-AP in the detection window of the microfluidic device, and (3) H2O2 concentration. We obtained linear calibration curves with wide dynamic ranges using Hmax and A. The detection limit of 1-AP determined with Hmax and A was as low as 0.05 fmole/injection (signal/background = 3.0).  相似文献   

20.
Kim P  Lee SE  Jung HS  Lee HY  Kawai T  Suh KY 《Lab on a chip》2006,6(1):54-59
We present simple soft lithographic methods for patterning supported lipid bilayer (SLB) membranes onto a surface and inside microfluidic channels. Micropatterns of polyethylene glycol (PEG)-based polymers were fabricated on glass substrates by microcontact printing or capillary moulding. The patterned PEG surfaces have shown 97 +/- 0.5% reduction in lipid adsorption onto two dimensional surfaces and 95 +/- 1.2% reduction inside microfluidic channels in comparison to glass control. Atomic force microscopy measurements indicated that the deposition of lipid vesicles led to the formation of SLB membranes by vesicle fusion due to hydrophilic interactions with the exposed substrate. Furthermore, the functionality of the patterned SLBs was tested by measuring the binding interactions between biotin (ligand)-labeled lipid bilayer and streptavidin (receptor). SLB arrays were fabricated with spatial resolution down to approximately 500 nm on flat substrate and approximately 1 microm inside microfluidic channels, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号