首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The oxidative behaviour of the antidiabetic agent glibenclamide on a bare carbon paste electrode (CPE) and a Sephadex-modified carbon paste electrode (SMCPE) was explored by cyclic and differential pulse voltammetry (DPV). The analysis procedure consisted of an open circuit accumulation step in stirred sample solution of Britton-Robinson buffer (0.04 mol L–1, pH 2.0). This was followed by medium exchange to a clean solution of Britton-Robinson buffer (0.04 mol L–1, pH 5.0), and subsequently an anodic potential scan was effected to obtain the voltammetric peak. The glibenclamide oxidation peak current obtained by DPV was proportional to the concentration of the glibenclamide in the range of 1.0×10–9 mol L–1 to 5.0×10–8 mol L–1 for 180 s accumulation time, with a detection limit of 4.0×10–10 mol L–1. A method was developed for the determination of glibenclamide in formulation and spiked human serum. Moreover, the proposed procedure was used to estimate the serum concentrations after oral administration of a 5 mg tablet of glibenclamide to three diabetic subjects.  相似文献   

2.
A voltammetric method of Cr(VI) determination in a flow system based on the combination of selective accumulation of the product of Cr(VI) reduction on hanging mercury drop electrode and a very sensitive method of chromium determination in the presence of cupferron previously described is proposed. The calibration graphs were linear from 3 × 10−9 to 3 × 10−8 and from 5 × 10−10 to 5 × 10−9 mol L−1 for accumulation times of 120 and 600 s, respectively. The detection limit for the accumulation time of 600 s was 9 × 10−11 mol L−1. The relative standard deviation was 5.1% (n = 5) for Cr(VI) concentration 1 × 10−8 mol L−1 and the accumulation time of 120 s. The influence of foreign ions commonly present in water samples is presented. The validation of the method was made by studying the recovery of Cr(VI) from spiked natural water samples.  相似文献   

3.
In this study, a new method for selective determination of Cr(VI) in water samples at pH 4 is presented using raffinose capped silver nanoparticles (Ag/Raff NPs) as an optical sensor. The method is based on the variation of LSPR absorption band intensity as a result of electrostatic interaction between the negatively charged Ag/Raff NPs and positive Cr(III) ions, in-situ produced by chemical reduction of Cr(VI) with ascorbic acid, combined with the fast kinetics of Cr(III) coordination to the –OH groups of the capping agent on the nanoparticle surface, further causing the nanoparticle aggregation. The calibration curve for Cr(VI) is linear in the range 2.5–7.5 μmol L−1, the limit of quantification achieved is 1.9 μmol L−1, and values of relative standard deviation vary from 3 to 5% for concentration level 1.9–7.5 μmol L−1. The interference studies performed in the presence of various metal ions show very good selectivity of Ag/Raff NPs toward Cr(VI) species. The added–found method is used to confirm the accuracy and precision of developed analytical approach.  相似文献   

4.
A simple and fast catalytic adsorptive stripping voltammetric procedure for trace determination of Cr(VI) in natural samples containing high concentrations of humic substances has been developed. The procedure for chromium determination in the presence of DTPA and nitrates was employed as the initial method. In order to enhance the selectivity vs. Cr(III) the measurements were performed at 40°C. Interference from dissolved organic matter such as humic and fulvic acids was drastically decreased by adding Amberlite XAD-7 resin to the voltammetric cell before the deaeration step. The whole procedure was applied to a single cell, which allowed monitoring of the voltammetric scan. Optimum conditions for removing humic and fulvic acids due to their adsorption on XAD-7 resin were evaluated. The use of XAD-7 resin also minimize interferences from various cationic, anionic, and nonionic surfactants. The calibration graph for Cr(VI) for an accumulation time of 30 s was linear in the range 5 × 10−10 to 5 × 10−8 mol L−1. The relative standard deviation for determination of Cr(VI) at a concentration of 1 × 10−8 mol L−1 was 3.5% (n = 5). The detection limit estimated from 3 times the standard deviation for low Cr(VI) concentrations and an accumulation time of 30 s was about 1.3 × 10−10 mol L−1. The proposed method was successfully applied to Cr(VI) determination at trace levels in soil samples.  相似文献   

5.
The chemical behaviour of Cr/VI/ at low concentrations /10–6–10–7 mol.1–1/ in several aqueous formic acid solutions was studied using high specific activity51Cr/VI/. A simple and efficient radiochromatographic method using paired cation and anion exchange analyses was used to quantify the51Cr/VI/ remaining in solution after different time periods as well as the several51Cr/III/ species formed. The product distribution of monomeric51Cr/III/ species includes those with 0, +1, +2 and +3 charges. Very little dimeric or higher polymeric species are formed. The rate of reaction of51Cr/VI/ with formic acid depends on the acid concentration, the presence or absence of sodium chloride and wheter, or not, the samples are exposed to light.  相似文献   

6.
A cobalt hexacyanoferrate (CoHCF) nanoparticle (size ca. 60 nm) chemically modified electrode (CME) was fabricated and the electrochemical behavior of thiols at this nanosized CoHCF CME was studied. In comparison with a bare glassy carbon (GC) electrode and with a general CoHCF CME which was electrodeposited in the traditional manner, the present nanosized CoHCF CME efficiently performed electrocatalytic oxidation for glutathione (GSH) and L-Cysteine (L-Cys) with relatively high sensitivity, outstanding stability, and long-life. Combined with high-performance liquid chromatography (HPLC), the nanosized CoHCF CME was used for electrochemical determination (ECD) of GSH and L-Cys. The peak currents were a linear function of concentrations in the range 2.0×10–7 to 2.0×10–4 mol L–1 for both GSH and L-Cys, with detection limits of 1.2×10–7 and 1.0×10–7 mol L–1, respectively. Coupled with microdialysis sampling, the HPLC–ECD system has been successfully used to assess the GSH and L-Cys content of rat striatum.  相似文献   

7.
We report the electroanalytical determination of lead by anodic stripping voltammetry at in-situ-formed, bismuth-film-modified, boron-doped diamond electrodes. Detection limits in 0.1 mol L–1 nitric acid solution of 9.6x10–8 mol L–1 (0.2 ppb) and 1.1x10–8 mol L–1 (2.3 ppb) were obtained after 60 and 300 s deposition times, respectively. An acoustically assisted deposition procedure was also investigated and found to result in improved limits of detection of 2.6×10–8 mol L–1 (5.4 ppb) and 8.5×10–10 mol L–1 (0.18 ppb) for 60 and 300 s accumulation times, respectively. Furthermore, the sensitivity obtained under quiescent and insonated conditions increased from 5.5 (quiescent) to 76.7 A mol–1 L (insonated) for 60 s accumulation and from 25.8 (quiescent) to 317.6 A mol–1 L (insonated) for 300 s accumulation. Investigation of the use of ultrasound with diluted blood revealed detection limits of the order of 10–8 mol L–1 were achievable with excellent inter- and intra-reproducibility and sensitivity of 411.9 A mol–1 L . For the first time, electroanalytical detection of lead in diluted blood is shown to be possible by use of insonated in-situ-formed bismuth-film-modified boron-doped diamond electrodes. This method is a rapid, sensitive, and non-toxic means of clinical sensing of lead in whole human blood.  相似文献   

8.
The voltammetric procedure for determination of traces of Cr(VI) [Anal. Chim. Acta (1992) 262:103] was modified by changing the temperature of the measurements. It was found that at the temperature of 40 °C the time of decrease of the Cr(III) signal was shortened from 30 to 5 min. As a result the total analysis time was drastically shortened. The modified procedure does not show any disadvantage as compared to the original method. The results of Cr(VI) determination by the modified procedure are less affected by Cr(III) as compared to the original method. The detection limit of the method was 2.5 × 10-11 mol L-1 (1.2 ng L-1). The validation of the modified procedure was performed by comparison of the results of analyses of tap and river water samples with those obtained using original procedure.  相似文献   

9.
A sensitive and selective protocol for the extraction of all forms of Cr(VI) from solid materials followed by determination by catalytic adsorptive stripping voltammetry has been elaborated. Cr(VI) was leached to a solution with 0.2 mol L?1 (NH4)2SO4/NH4OH+0.1 mol L?1 EDDS (pH 9.5) and simultaneously Cr(III) was transferred to a nonactive electrochemical complex with EDDS. The method allows for Cr(VI) determination in solid samples containing even a 1000–2000 fold excess of extractable Cr(III) without its noticeable influence. The effects of several experimental variables such as the composition and pH of the extractant, the time and temperature of the solid sample mixing with the extractant were studied. At the optimized conditions more than 95% of total Cr(VI) recoveries from solid samples were achieved. The validation of the proposed procedure was carried out by Cr(VI) determination in certified reference material CRM 019 Ash, spiked and unspiked with Cr(III), and by comparing the obtained results with those obtained using other common extraction procedures.  相似文献   

10.
A modified SBA-15 mesoporous silica was developed, as an adsorbent, for the removal of Cr(VI) ions from natural-water samples. The effects of experimental parameters, including pH of solution, sample and eluent flow rate, the eluent composition, the eluent volume, and the effect of coexisting ions on the separation and determination of Cr(VI), were investigated. It was shown that Cr(VI) was selectively adsorbed from aqueous solution at pH 3, but Cr(III) could be adsorbed from solution at alkaline pH range. The retained Cr(VI) was eluted with 0.5?mol?L?1 KCl solution in 0.1?mol?L?1 Na2CO3 subsequently. Under the optimum conditions, the modified mesoporous silica (py-SBA-15) with a high pore diameter exhibited an adsorption capacity of 136?mg?g?1 and a lower limit of detection than 2.3?µg?L?1 by using diphenylcarbazide as a chromophorous reagent for the determination of Cr(VI) ions. A preconcentration factor as high as 200 was calculated for Cr(VI). The loaded py-SBA-15 can be reactivated with recovery of more than 98.5% over at least eight cycles. The relative standard deviation (RSD) for Cr(VI) ion recovery was less than 1.8%. Validation of the outlined method was performed by analysing a certified reference material (BCR 544). The proposed method was applied to determine Cr(VI) value in natural and waste water samples successfully.  相似文献   

11.
A novel procedure has been developed for spectrophotometric determination of anionic surfactants in water using a solenoid micro-pump as fluid-propulsion device. The proposed method is based on substitution of methyl orange (MO) by anionic surfactants in the formation of an ion-pair with the cetyl pyridine ion (CPC+) at pH 5.0. The flow network comprised four solenoid micro-pumps which, under microcomputer control, enabled sample and reagent introduction, and homogenisation in the reaction zone. The system is flexible and simple to operate and control, and sensitive and precise. The analytical plot for the anionic surfactant was linear between 1.43×10–6 and 1.43×10–5 mol L–1 (0.5 to 5.0 mg L–1; R=0.997, n=5). The relative standard deviation was 0.8% (n=11) for a sample containing 5.74×10–6 mol L–1 (2 mg L–1) surfactant. The limit of detection was 9.76×10–8 mol L–1 (0.034 mg L–1) and the sampling throughput was 60 determinations per hour. The results obtained for washing-water samples were comparable with those obtained by use of the reference method, and no significant differences at the 95% confidence level were observed.  相似文献   

12.
The coordination reactions of bromopyrogallol red (BPR) with tri- and hexavalent chromium in the presence of cetyltrimethylammonium bromide (CTAB) have been studied by absorption spectrometry. Results show that the reactions of Cr(VI) and Cr(III) with BPR in the absence or presence of CTAB have different temperature dependences. The reaction mechanism of Cr(VI) is that Cr(VI) is first reduced by BPR to Cr(III) and then the Cr(III) produced reacts with BPR. Based on the study on the coordination reactions and the effects of surfactants upon them, a simple, rapid, sensitive and accurate method for Cr speciation has been developed. Over the range of 0–8 g Cr(VI) or 0–12g Cr(III) per 25ml final volume, the calibration curve is linear with a detection limit of 3.5 × 10–7 mol/1 for Cr(VI) or 4.4 × 10–7 mol/1 for Cr(III).  相似文献   

13.
An adsorptive stripping voltammetric method for speciation analysis of chromium in natural water samples has been developed. Ethylenediaminetetraacetic acid (EDTA) and diethylenetriaminepentaacetic acid (DTPA) were used as complexing agents for Cr(III) present in the sample and formed as products of Cr(VI) reduction, respectively. Under optimum experimental conditions linear relations in the range from 1×10?6 to 3×10?5 mol L?1 without accumulation and from 1×10?9 to 1×10?7 at 30 s accumulation time were obtained for Cr(III) and Cr(VI), respectively. For samples in which Cr(III) concentration is higher than 1×10?6 mol L?1 the Cr(III) and Cr(VI) were determined simultaneously in one voltammetric cell. For samples in which Cr(III) concentration is below 1×10?6 mol L?1 only Cr(VI) was selectively determined in the presence of Cr(III), which did not influence the Cr(VI) signal. The determination of Cr(III) and Cr(VI) was successful with the application of the proposed procedure in the presence of common foreign ions. The presented method was applied for the speciation of chromium in spiked tap and river water samples with satisfactory results.  相似文献   

14.
A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP–MS). High resolution (HR) ICP–MS was used to examine the influence of polyatomic interferences on the detection of the 52Cr+ and 53Cr+ isotopes. If there was strong interference with m/z 52 for plastic materials, it was possible to use quadrupole ICP–MS for m/z 53 if digestions were performed with HNO3+H2O2. This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH4+/NH3 buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC–ICP–MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc–nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient. In the case of painted metallic plate, because of a reactive matrix towards Cr(VI), its extraction without degradation was difficult to perform.  相似文献   

15.
Under natural conditions gold has low solubility that reduces its bioavailability, a critical factor for phytoextraction. Researchers have found that phytoextraction can be improved by using synthetic chelating agents. Preliminary studies have shown that desert willow (Chilopsis linearis), a common inhabitant of the Chihuahuan Desert, is able to extract gold from a gold-enriched medium. The objective of the present study was to determine the ability of thiocyanate to enhance the gold-uptake capacity of C. linearis. Seedlings of this plant were exposed to the following hydroponics treatment: (1) 5 mg Au L–1 (2.5×10–5 mol L–1), (2) 5 mg Au L–1+10–5 mol L–1 NH4SCN, (3) 5 mg Au L–1+5×10–5 mol L–1 NH4SCN, and (4) 5 mg Au L–1+10–4 mol L–1 NH4SCN. Each treatment had its respective control. After 2 weeks we determined the effect of the treatment on plant growth and gold content by inductively coupled plasma–optical emission spectroscopy (ICP–OES). No signs of shoot-growth inhibition were observed at any NH4SCN treatment level. The ICP–OES analysis showed that addition of 10–4 mol L–1 NH4SCN increased the concentration of gold by about 595, 396, and 467% in roots, stems, and leaves, respectively. X-ray absorption spectroscopy (XAS) studies showed that the oxidation state of gold was Au(0) and that gold nanoparticles were formed inside the plants.  相似文献   

16.
《Electroanalysis》2006,18(12):1223-1226
A sensitive catalytic adsorptive stripping voltammetric procedure for determination of traces of total chromium in environmental samples is reported. The method is based on the preconcentration of a Cr(III)? H2DTPA complex by adsorption at the HMDE from an acetate buffer solution at the potential ?1.0 V vs. Ag/AgCl. Total chromium was determined as Cr(III) after reduction of Cr(VI) to Cr(III) by NaHSO3. In order to stabilize the signal of Cr(III) the measurements were performed at 5 °C. The calibration graph for chromium for an accumulation time of 60 s was linear in the range from 5×10?10 to 5×10?8 mol L?1. The relative standard deviation for a chromium concentration of 1×10?8 mol L?1 was 3.9% (n=5). The detection limit for accumulation time of 60 s was about 8×10?11 mol L?1. The validation of the procedure was performed by the analysis of the certified reference materials.  相似文献   

17.
An emulsion liquid membrane method has been developed for separating traces of heavy metals from an iron matrix. A 1.0-mL volume of aqueous iron(III) solution (pH 2.0) was emulsified with a mixture of 0.6 mL toluene, 2.4 mL n -heptane, and 80 mg sorbitan monooleate (Span-80). The resulting water-in-oil type emulsion was gradually injected into 25 mL of 1.5 mol L–1 hydrochloric acid solution containing 30 mmol L–1 8-quinolinol and 1.0 mol L–1 of ammonium sulfate and was dispersed as numerous tiny globules by stirring for 40 min. More than 90% of the iron(III) diffused through the oil layer to the external hydrochloric acid solution with the aid of complexation with 8-quinolinol, whereas trace heavy metals, e.g. Cr(III), Mn(II), Co(II), Ni(II), Cu(II), and Pb(II), remained quantitatively in the internal aqueous phase. After collecting the dispersed emulsion globules, they were demulsified and trace metals in the segregated aqueous phase were determined by graphite-furnace atomic absorption spectrometry. Owing to sufficient removal of the iron matrix trace metal impurities in high-purity iron were successfully determined without interference, as was confirmed by analysis of certified reference materials.  相似文献   

18.
A new grafted polymer has been developed by the chemical modification of Amberlite XAD-16 (AXAD-16) polymeric matrix with [(2-dihydroxyarsinoylphenylamino)methyl]phosphonic acid (AXAD-16-AsP). The modified polymer was characterized by a combination of 13C CPMAS and 31P solid-state NMR, Fourier transform-NIR-FIR-Raman spectroscopy, CHNPS elemental analysis, and thermogravimetric analysis (TGA). The distribution studies for the extraction of U(VI), Th(IV), and La(III) from acidic solutions were performed using an AXAD-16-AsP-packed chromatographic column. The influences of various physiochemical parameters on analyte recovery were optimized by both static and dynamic methods. Accordingly, even under high acidities (>4 M), good distribution ratio (D) values (102–104) were achieved for all the analytes. Metal ion desorption was effective using 1 mol L–1 (NH4)2CO3. From kinetic studies, a time duration of <15 min was sufficient for complete metal ion saturation of the resin phase. The maximum metal sorption capacities were found to be 0.25, 0.13, and 1.49 mmol g–1 for U(VI); 0.47, 0.39, and 1.40 mmol g–1 for Th(IV); and 1.44, 1.48, and 1.12 mmol g–1 for La(III), in the presence of 2 mol L–1 HNO3, 2 mol L–1 HCl, and under pH conditions, respectively. The analyte selectivity of the grafted polymer was tested in terms of interfering species tolerance studies. The system showed an enrichment factor of 365, 300, and 270 for U(VI), Th(IV), and La(III), and the limit of analyte detection was in the range of 18–23 ng mL–1. The practical applicability of the polymer was tested with synthetic nuclear spent fuel and seawater mixtures, natural water, and geological samples. The RSD of the total analytical procedure was within 4.9%, thus confirming the reliability of the developed method.  相似文献   

19.
Liquid chromatography with amperometric detection (LC-AD) is developed and applied to simultaneously determine five aromatic amines. In the LC-AD, a new carbon nanotubes/poly(3-methylthiophene) modified dual-electrode is fabricated and then used as the working electrode. It is found that this chemically modified electrode (CME) exhibits efficiently electrocatalytic oxidation for aromatic amines with relatively high sensitivity, stability and long-life. Thus, lower detection in LC-AD can be achieved, which are 4.0 × 10–8 mol L–1 for aniline, 1.6 ×10–7 mol L–1 for 4-nitroaniline, 1.0 × 10–7 mol L–1 for 4-chloroaniline, 1.5 × 10–7 mol L–1 for 1-naphthylamine, 1.7 × 10–7 mol L–1 for 2-bromoaniline. The recoveries of the five analytes are also determined, which range between 0.95 and 1.05 for drinking water, 0.86 and 1.10 for the LiWa River water.  相似文献   

20.
A sensitive procedure for determination of micro-traces of Co(II) by adsorptive stripping voltammetry is proposed. The procedure exploits the enhancement of the cobalt peak obtained by use of the system Co(II)–dimethylglyoxime–piperazine-1,4-bis(2-ethanesulfonic acid)–cetyltrimethylammonium bromide. Using the optimized conditions, a detection limit (based on the 3 criterion) for Co(II) of 1.2×10–11 mol L–1 (0.7 ng L–1) was achieved. The calibration plot for an accumulation time of 30 s was linear from 5×10–11 to 4×10–9 mol L–1. The procedure was validated by analysis of certified reference materials and natural water samples.  相似文献   