首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A flow injection (FI) on-line preconcentration procedure by using a nanometer-sized alumina packed micro-column coupled to inductively coupled plasma mass spectrometry (ICP-MS) was described for simultaneous determination of trace metals (V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb) in the environmental samples. The effects of pH value, sample flow rate, preconcentration time, and interfering ions on the preconcentration of analytes have been investigated. Under the optimized operating conditions, the adsorption capacity of the nanometer-sized alumina for V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb were found to be 11.7, 13.6, 15.7, 9.5, 12.2, 13.3, 17.1, 17.7 and 17.5 mg g−1, respectively. With 60 s preconcentration time and 60 s elution time, an enrichment factor of 5 and the sampling frequency of 15 h−1 were obtained. The proposed method has been applied to the determination of trace metals in environmental certified reference materials and natural water samples with satisfactory results.  相似文献   

2.
Narin I  Soylak M  Elçi L  Doğan M 《Talanta》2000,52(6):1041-1046
A simple preconcentration method is described for the determination of Cu, Mn, Co, Cd, Pb, Ni and Cr in water samples by flame AAS. Trace metal ions in water were sorbed as pyrocatechol violet complexes on activated carbon column at the pH range of 4–8, then eluted with 1 M HNO3 in acetone. The effect of major cations and anions of the natural water samples on the sorption of metal ions has been also investigated. The concentration of the metal ions detected after preconcentration was in agreement with the added amount. The present method was found to be applicable to the preconcentration of Cu, Mn, Co, Cd, Pb, Ni and Cr in natural water samples with good results such as R.S.D. from 3 to 8% (N=10) and detection limits under 70 ng l−1.  相似文献   

3.
煤中痕量元素在循环流化床锅炉中的迁移行为与富集特性   总被引:2,自引:0,他引:2  
对天津市某电厂循环流化床(CFB)锅炉燃用的原煤及燃烧产物底灰、飞灰、细飞灰(≤50 μm)进行痕量元素含量的测定,分析了Be、Zn、Hg、V、Cr、Mn、Co、Ni、Cu、As、Se、Cd、Pb 13种痕量元素在燃烧过程中的迁移行为,揭示了痕量元素在CFB锅炉中的分配、富集特性。结果表明,CFB锅炉中,较低的炉温对于痕量元素的迁移富集产生了较大的影响。由相对富集系数得知,Be、V、Co、Se在底灰中耗散,在飞灰中富集,Zn、Mn倾向于在底灰中富集,元素Cd、Pb、Ni、Cu挥发性较强,在底灰和飞灰中均是耗散。As受钙氧化物影响,挥发性表现并不明显。Hg在底灰和飞灰中相对富集系数均很低,表明Hg在整个燃烧过程中以气态形式排放;Hg、As、Se、V、Cr、Mn、Co、Ni、Cu、Zn、Pb均有向小颗粒物中富集的趋势。根据相对富集系数以及研究的13种元素在低温CFB锅炉中的迁移行为,将这些元素分为三类:A类(ER<0.1),主要是以气态形式排放元素Hg;B类(0.1R≤0.85),较易挥发元素As、Be、Ni、Cu、Se、Cd、Pb、Co、V;C类(ER>0.85),主要残留在固体产物中元素Zn、Mn、Cr。  相似文献   

4.
A new method is proposed using a microcolumn (20 mm × 2.0 mm) packed with nanometer-sized zirconia as solid-phase extractor for the separation/preconcentration of Mn, Cu, Cr, Zn, Ni and Co prior to their determination by inductively coupled plasma optical emission spectrometer (ICP-OES) in environmental samples. The factors affecting the separation and preconcentration of analytes such as pH, sample flow rate and volume, eluent concentration and volume were determined, interfering ions were studied, and the optimal experimental conditions were established. The adsorption capacity of nanometer-sized ZrO2 for Mn, Cu, Cr, Zn, Ni and Co was found to be 1.3, 1.3, 1.7, 2.0, 3.9 and 1.5 mg g−1, respectively. The detection limits of the method were 12, 58, 24, 2, 7 and 36 ng L−1, respectively, with a preconcentration factor of 25. The precision of this method was 1.7% (Mn), 2.9% (Cu), 5.9% (Mn), 3.8% (Mn), 6.2% (Mn) and 4.3% (Mn) with 9 determinations of 10 ng mL−1 of target analytes, respectively. The method was successfully applied to the determination of trace metals in lake water, dried fish samples, certified reference materials of human hair and milk, and provided satisfactory results.  相似文献   

5.
Liu Y  Liang P  Guo L 《Talanta》2005,68(1):25-30
Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer TiO2) was prepared by sol-gel method and characterized by using X-ray diffraction (XRD) and scanning electron microscope (SEM). The adsorptive potential of immobilized nanometer TiO2 for the preconcentration of trace Cd, Cr, Cu and Mn was assessed in this work. The metal ions studied can be quantitative retained at a pH range of 8-9, and 0.5 mol L−1 HNO3 was sufficient for complete elution. The adsorption capacity of immobilized nanometer TiO2 for Cd, Cr, Cu and Mn was found to be 2.93, 2.11, 6.69 and 2.47 mg g−1, respectively. A new method using a microcolumn packed with immobilized nanometer TiO2 as sorbent has been developed for the preconcentration of trace amounts of Cd, Cr, Cu and Mn prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). The method has been successfully applied for the determination of trace elements in some environmental samples with satisfactory results.  相似文献   

6.
A microwave-assisted digestion procedure using HNO3, HF, and H2O2 has been developed for analysis of elements in ambient particulate matter (PM). The samples are collected on cellulose filters and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). The ICP-MS is calibrated with external standards, and recovery of analytes is tested with NIST SRM 1648 Urban Dust. This method has been used to quantify the airborne concentrations of a large number of elements, including Ag, As, Ba, Be, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, K, Li, Mg, Mn, Mo, Ni, Pb, Rb, Se, Sb, Sr, Ti, Tl, V, and Zn. For the majority of these elements, recovery of the NIST SRM is within 15% of the certified values.  相似文献   

7.
Li S  Deng N  Zheng F  Huang Y 《Talanta》2003,60(6):1097-1104
The adsorption of W (VI) on different metal oxides (TiO2, ZrO2), different crystal form of TiO2 (rutile, anatase) with high surface areas was studied and compared under different pH. A novel method for preconcentration of W (VI) with nanometer size titanium dioxide (rutile) and determination by spectrophotometry has been developed. W (VI) was selective adsorbed on 100 mg TiO2 from 250 ml solution at pH 3.0, then eluted by 2 ml 9 mol l−1 sodium hydroxide solution. The eluent was adjusted to 5 ml pH 0 solution, added 0.5 ml 12 mol l−1 HCl, 0.3 ml 3% TiCl3, 0.3 ml 50% NH4SCN, stirred for 20 min, used for the analysis of W (VI) by measuring the absorbance at 402 nm with spectrophotometry, based on the chromogenic reaction between the W (VI) and the mixture of TiCl3 and NH4SCN. This method gave a concentration enhancement of 50 for 250 ml sample, eliminated the sizable interferences on direct determination with spectrophotometry. Detection limits (3σ, n=11) of 1.2 ng ml−1, relative standard deviation of 2.3% at 10 ng ml−1 level were obtained. The method was applied to determine the W (VI) in hot spring water, river water, tap water and stream sediment. Analytical recoveries of W (VI) added to samples were 98–101%.  相似文献   

8.
A field oriented and economical method of coprecipitation of trace elements like Al, Au, Bi, Cd, Co, Cu, Fe, Mo, Ni, Pb, Pd, Ti, V, W, Zn and REE has been developed. A novel reductant D-glucose, reduces KMnO4 in solution to form a precipitate of MnO2. Two liters of clear natural water sample is adjusted to pH 3.5–4.0, and is treated with 10 ml of 1% KMnO4 and 20 ml of 0.1% D-glucose. The sample is heated at a temperature of 75–80 °C, MnO2 is formed which coprecipitates the above trace elements. The precipitate is separated by filtration, dissolved in 2 ml of 50% HCl and 2 ml of 30% H2O2 and diluted to 25 ml for analysis using AAS and ICP-AES. The recoveries were found to be 96–105%. The preconcentration factor is 80. Limits of determination by the proposed method in natural waters are 1 μg l−1 for Al, Cd, Mo, V, W, Ti and Zn, 5 μg l−1 for Au, Bi, Co, Cu, Fe, Ni, Pb and Pd and 8 μg l−1 for REE. The RSD of the present procedure (n=5) is 8% at 5 μg l−1 level. Twenty water samples can be analyzed by an analyst in an 8-h day.  相似文献   

9.
Method of sorption–atomic-absorption determination of Co, Cr, Cu, Fe, Mn, and Ni in samples of high-purity Nb2O5 with heterochain S,N-containing sorbents was developed. The method is based on the sorption preconcentration of trace impurities followed by their determination by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS). Selectivity of three original inhouse synthesized S,N-containing heterochain sorbents was studied. The recoveries of Co, Cr, Cu, Fe, Mn, and Ni using heterochain sorbents OKS, MTH, and GLSH were 100, 80, and 76%, correspondingly. Sorbent “OKS”, which provided the quantitative recovery of trace impurities, was chosen for further research. The sorption conditions for chloride solutions of different acidities (0.1–3 M HCl) were studied and optimized. Using the conditions established for the sorption and HR CS GFAAS analysis, trace Co, Cr, Cu, Fe, Mn, and Ni were determined in high purity Nb2O5 with a relative error less than 5%. The trueness control of the obtained results is confirmed by the “added–found” method. The developed method allows us to determine concentrations of analytes: 0.02–0.20 ppm Co, 2.0–3.3 ppm Cr, 0.2–1.5 ppm Cu, 6.0–21.0 ppm Fe, 0.6–0.8 ppm Mn, and 2.8–3.5 ppm Ni. The proposed methodology can be successfully extended to the determination of various trace elements in other high-purity inorganic materials.  相似文献   

10.
A procedure based on electrothermal evaporation (ETV) and inductively coupled plasma atomic emission spectrometry (ICP-OES) for the determination of trace impurities in Al2O3 powders without any sample pretreatment is presented. With the aid of matrix modifier the transport and the evaporation efficiency for refractory compounds could be increased by forming halides with a lower boiling point. As calibration is still a problem in direct solid sample analysis, different calibration approaches including the use of certified reference materials from NIST and standard addition of aqueous solutions of analytes were discussed. The accuracy obtained with calibration and with the standard addition method was shown up for the elements Ca, Fe, Ga, Mg, Mn, Na, Ni and V for the case of Al2O3 NIST standard reference material (SRM 699). The ETV–ICP-OES method was used for the analysis of Al2O3 powders with impurities in the low μg/g range and the results for the elements Ca, Fe, Ga, Mg, Mn, Na, Ni and V obtained with evaporation of discrete powder amounts with ETV–ICP-OES and slurry evaporation under the use of ultrasonic homogenization during the sampling and ETV–ICP-MS were shown to be in a good agreement.  相似文献   

11.
以TiO2为载体,采用等体积浸渍法制备了负载型CuxMn1-xCe0.75Zr0.25/TiO2(x=1.0、0.75、0.5、0.25、0)负载型催化剂,采用XRD、H2-TPR、O2-TPD和XPS等方法对催化剂进行了表征,并通过低温等离子体协同催化剂对大流量的甲苯模拟废气进行了催化降解反应研究。结果表明,Cu和Mn单主金属催化剂的活性优于Cu-Mn双主金属催化剂,其原因是双金属催化剂中Mn的添加减弱了Cu与助剂Ce之间的相互作用,使得催化剂的晶格氧减少,低温还原性能降低。在反应初期,甲苯降解主要依赖于催化剂的活性,具有较好的低温还原性以及丰富的氧空穴和晶格氧含量的CuCe0.75Zr0.25/TiO2的活性最好;Mn具有较强的O3分解能力,当等离子体比能密度(SED)增加到一定值后,等离子体与催化剂的协同作用增强,从而使得MnCe0.75Zr0.25/TiO2催化剂活性高于CuCe0.75Zr0.25/TiO2,强化了甲苯的脱除。  相似文献   

12.
李悦  张婷婷  王娟  朱圳  贾冰  余江 《物理化学学报》2016,32(8):2084-2092
通过调控Cu负载量及Cu/Mn原子比,探究其对TiO2负载Cu-Mn复合氧化物(CuxMny/TiO2)催化材料中活性组分间相互作用的影响,结果表明,铜负载量为15% (w,质量分数)和Cu/Mn原子比为1 : 1时有利于类铜锰尖晶石相Cu1.5Mn1.5O4的形成,随着Cu负载量的增加促使氧物种从晶格氧向表面吸附氧转移。复合催化材料中铜负载量的变化及Cu/Mn原子比对活性组分和催化活性间的相互作用影响显著。结果发现Cu15Mn15/TiO2在225 ℃时使正己醛转化率达到90% (T90),材料良好的性能归因于其具有较高的Cu2+与Oads含量,并可与Mn2+实现双还原氧化过程。结果表明,Cu15Mn15/TiO2复合材料中的类铜锰尖晶石活性组分可完成redox循环,以保持催化材料较高的稳定性。  相似文献   

13.
Arslan Z 《Talanta》2005,65(5):1326-1334
A method is developed for determination of trace elements, including Ag, As, Cd, Co, Cr, Cu, Mn, Ni, Se, Tl and Zn, in fish otoliths by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Hydrofluoric acid was used to precipitate calcium resulting from acid dissolution of otolith calcium carbonate. Initial acidity of the sample solution influenced the precipitation efficiency of calcium fluoride. Up to 99.5% of Ca was precipitated in solutions that contained less than 2% (v/v) HNO3. Recoveries of the elements obtained from spiked artificial otolith solutions were between 90 and 103%. Stabilization of the elements within the ETV cell was achieved with 0.3 μg Pd/0.2 μg Rh chemical modifier that also afforded optimum sensitivity for multielement determination. The method was validated by the analysis of a fish otolith reference material (CRM) of emperor snapper, and then applied to the determination of the trace elements in otoliths of several fish species captured in Raritan Bay, New Jersey. Results indicated that fish physiology and biological processes could influence the levels of Cu, Mn, Se and Zn in the otoliths of fish inhabiting a similar aqueous environment. Otolith concentrations of Cr and Ni did not show any significant differences among different species. Concentrations for Ag, As, Cd, Co and Tl were also not significantly different, but were very low indicating low affinity of otolith calcium carbonate to these elements.  相似文献   

14.
Methods are described for the determination of trace and ultra trace amounts of Cd, Co, Cr, Cu, Fe, Mn, Ni and Pb in natural waters, alkali and alkaline earth salts. Separation and preconcentration of trace metals is achieved by a column solid phase extraction procedure using silica gel modified with derivatives of dithiocarbamates — Na-DDTC (sodium diethyldithio-carbamate and HMDTC (ammonium hexamethylene-dithiocarbamate) as column packing material. The influence of the sorbent preparation procedure on the degree of sorption of the trace analytes is examined for different pH values of the sample solution. Isobutylmethyl ketone (IBMK) is proposed as an effective eluent for quantitative elution of retained metal ions. Optimal instrumental parameters for ETAAS determination of preconcentrated elements in organic eluate are presented. Practical application of sorbents in analysis of natural waters and alkali and alkaline earth salts is demonstrated. Proposed preconcentration procedure combined with ETAAS determination of trace analytes allows the determination of 0.04 g l–1 Cd, 0.1 g l–1 Cr, Cu, and Mn and 0.3 g l–1 Co, Fe, Ni and Pb in natural waters and 1.10–7% Cd, 3.10–7% Cr and Mn, 7.10–7% Co, Ni and Pb and 2.10–6% Cu and Fe in alkali and alkaline earth salts.  相似文献   

15.
Elçi L  Sahin U  Oztaş S 《Talanta》1997,44(6):1017-1023
A method for determination of trace amounts of Cu, Fe, Pb, Mn, Zn, Cd, Ni, Bi and Cr in aqueous solutions by flame atomic absorption spectrometry after coprecipitation by using a combination of sodium diethyldithiocarbamate as a chelating agent and cobalt as a carrier element was introduced. Different factors including amounts of reagents, pH of sample solution, standing time, sample volume for the precipitation and matrix effects were examined. Under selected conditions, the relative standard deviation of the combined method of sample treatment, coprecipitation and determination with flame AAS (n = 9) is generally about 3.5-6.9%; the limits of detection (3 s, n = 20) for the analytes were found to be between 4 and 64 microg 1(-1). The procedure was applied to the analysis of sea water and dialysis concentrate samples with quantitative recovery, > or =95%.  相似文献   

16.
A new method that utilizes p-dimethylaminobenzaldehyde-modified nanometer SiO2 (SiO2-p-DMABD) as a solid phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). The preconcentration conditions of analytes were investigated, including the pH value, the shaking time, the mass of sorbent, the sample flow rate and volume, the elution condition and the interfering ions. The adsorption capacity of nanometer SiO2-p-DMABD was found to be (mg g− 1) Cr(III): 6.2, Cu(II): 18.6, Fe(III): 4.7 and Pb(II): 6.0 at pH 4. The adsorbed metals were quantitatively eluted with 4 mL of 1.0 mol L− 1 HCl. According to the definition of IUPAC, the detection limits (3σ) of this method for Cr(III), Cu(II), Fe(III) and Pb(II) were 0.79, 1.27, 0.40 and 1.79 ng mL− 1, respectively. The proposed method achieved satisfied results when it was applied to the determination of trace Cr(III), Cu(II), Fe(III) and Pb(II) in biological and water samples.  相似文献   

17.
The MOCVD(Metal-Organic Chemistry Vapour Deposition) technology has already been important means in research and production of semiconductor membrane material at these years. The metal-organic compounds are often used to be the raw materials of MOCVD in electrical material industry. Trimethyl gallium is one of the key raw materials. By chemical characteristic, trimethyl gallium is much reactive. It is easy to explode if touches water or air. Hence, we study the safe and correct decomposition of trimethyl gallium,and also study the analytical method of determining high purity trimethyl gallium. In this paper, we developed a method of determining Al,As,Au, B, Ba, Be, Bi, Ca, Cd, Co, Cr, Cu,Fe, Ge, Hf,Hg, Mg, Mn, Mo, Nb,Ni,Pb,Sb,Sc, Si,Sn, Sr, Ta, Ti,V, Zn, Zr etc. 32 trace impurity elements in high purity Ga(CH3)3 by ICP-AES.  相似文献   

18.
The binding of metals to proteins in blood fractions was investigated applying hydrophobic interaction chromatography (HIC) for protein separation and graphite furnace atomic absorption spectrometry (GFAAS) as the element specific detector. For the semi-preparative separation of metalloproteins in erythrocytes and blood plasma, a HIC column (Fractogel EMD Phenyl I (S) 150 mm×10 mm I.D.) was adapted. The separation column was calibrated with the same four standard proteins as used in Pomazal et al. [Analyst 124 (1999) 657]. The sample injection volume and the ammonium sulphate gradient set-up were optimized: 20 or 200 μl, respectively, of blood plasma and of lysed erythrocytes were injected. The separated proteins were collected in 4-ml fractions and analyzed by GFAAS off-line. An optimization of the GFAAS measuring parameters for Cu, Mn, Fe, Zn, Co, Ni, and Cr was performed. For each element, a specific temperature program was optimized with respect to the matrix of the HIC eluate (0.02 M NaH2PO4, 1.8 M (NH4)2SO4). The obtained metal profiles of the eluate were compared with the HIC chromatograms. The limits of detection (LOD) for the elements by GFAAS were: 0.5 ng Cu/ml; 0.2 ng Mn/ml; 1 ng Fe/ml; 0.2 ng Zn/ml; 0.12 ng Co/ml; 0.2 ng Ni/ml; 0.16 ng Cr/ml. The GFAAS method enabled the detection of the proteins of interest via the metals.  相似文献   

19.
《Analytical letters》2012,45(3):509-534
Abstract

The sequential determination of 14 trace metals, Al, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Mo, Cd, Sb and Pb, in rain and river water samples has been investigated using an inductively coupled plasma mass spectrometry (ICP-MS) with a graphite rod electrothermal vaporizer (ETV) in the presence of the mixed modifier of palladium nitrate and magnesium nitrate. The sensitivity enhancements due to the presence of the modifier were observed for all analyte elements. Detection limits as high as 0.52, 0.13, 0.89, 0.35, 1.76, 0.5, 0.9, 0.5, 0.04, 1.03, 0.28, 0.07, 0.1 and 3.78 pg, respectively, for Al, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Mo, Cd, Sb and Pb have been achieved. For the determination of trace metals in both rain and river water samples by this method, the repeatibility of sample solution were very good, i.e. from 1% to 7% (as a coefficient variation) and the recoveries of elements were good enough, i.e. from 81% to 106%, by using a standard addition method. There was no difference between the results obtained by nebulizer ICP-MS and those obtained by this method, except for zinc and arsenic.  相似文献   

20.
Neutron activation analysis methods for the determination of impurities in zirconium cladding material and uranium oxide are described. Detection limits for the elements Al, Cd, Cr, Co, Cu, Hf, Fe, Mn, Ni, W and U in zirconium are below that required by the ASTM B 352-79 standard. The method has been tested on the NIST SRM 360a Zircaloy-2 from which the elements Na, Mg, Al, Ca, V, Cr, Fe, Co, Ni, Cu, Eu and U have been detected. The values for Cr, Fe, Ni and Cu are compared with the certified values. A method for the pre-irradiation separation of the elements Mg, Na, Al, K, Sc, Ca, V, Mn, Cr, Fe, Co, Cu, Zn, Rb, Zr, Cd, Cs, REE and Hf from uranium has been developed. A neutron activation analysis method for the determination of those elements in uranium is described. The method is tested by the analysis of the IAEA reference sample SR-54/64. The elements Al, Mn, V, Cu, Cr, Co, Ni and Fe have been detected and the results compared with the certified values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号