首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Li J  Chen L  Wang X  Jin H  Ding L  Zhang K  Zhang H 《Talanta》2008,75(5):1245-1252
An automated system using on-line solid-phase extraction (SPE) high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was developed for the determination of tetracyclines (TCs), such as tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC), metacycline (MC), and doxycycline (DC) in honey. One milliliter diluted honey sample was injected into a conditioned C18 SPE column and the matrix was washed out with water for 3 min. By rotation of the switching valve, TCs were eluted and transferred to the analytical column by the chromatographic mobile phase. Chromatographic conditions were optimized. TCs were separated in less than 8 min with a gradient elution using a mixture of 0.8% formic acid and acetonitrile. The UV detection was performed at 365 nm. The conditions for on-line SPE, including solvent and total time for loading sample and washing matrix were also optimized. Time for extraction and separation decreased greatly. For the five kinds of TCs, the limits of detection (LODs) at a signal-to-noise of 3 ranged from 5 to 12 ng g−1. The relative standard deviations (R.S.D.) for the determination of TCs ranged from 3.4 to 7.1% within a day and ranged from 3.2 to 8.9% in 3 days, respectively.  相似文献   

2.
A liquid chromatography electrospray mass spectrometry (LC/ESI/MS) method has been developed to identify and quantify microcystins in fish liver and intestine. Microcystins (MCs) were extracted from 500 mg sample with methanol-water (85:25, v/v) and the extracts concentrated to 250 microl. The parameters were optimized by a full factorial 2(3) design. Neither laborious pre-treatment nor clean up were necessary. MCs were separated using conventional C18 column and an acetonitrile-acidified water (pH 3) gradient. Negative samples (without MCs) were discriminated by liquid chromatography diode array detection (LC/DAD). The limits of detection (LOD) and the limits of quantification (LOQ) resulted equal for MC-RR, MC-YR, and MC-LR and were 0.1 and 0.5 microg g(-1), respectively. MCs recoveries at three levels in spiked samples (0.5-3.0 microg g(-1)) were > 92%, with relative standards deviations (RSDs) < 16% for liver samples and > 68% with RSDs < 18% for intestine samples. The proposed method was applied to determine MC-LR in exposed fish to evaluate the bioaccumulation risk. The results showed the transference of MC-LR from cyanobacterial cells to fish tissues.  相似文献   

3.
Guo P  Guan Z  Wang W  Chen B  Huang Y 《Talanta》2011,84(2):587-592
In this paper, the potential use of multiwalled carbon nanotubes (MWCNTs) as solid phase extraction (SPE) adsorbent was evaluated for preconcentration of linear alkylbenzene sulfonates (LAS) using ion-pair (IP)-SPE with tetrabutylammonium hydroxide (TBAH). The LAS homologues present in the aqueous sample were ion-paired with TBAH and the solution was passed through the MWCNT cartridges. The analytes retained in the cartridge were eluted with methanol and the concentrated methanol extract was analysed by HPLC-UV. In order to obtain the satisfactory recovery of LAS homologues, various parameters including the type and amount of the ion-pair reagents, the desorption and enrichment conditions such as the effect of eluent and its volume, pH, the flow rate, the ultrasonic time of sample, and the volume of sample solution were systematically optimized. Under the optimal conditions, LAS homologues could be easily extracted by the proposed SPE cartridge. The favorable limits of detection (LOD) for LAS homologues were in the range from 0.02 to 0.03 μg L−1, and the relative standard deviations (RSDs) were 1.55-2.54% for 10 μg L−1 LAS (n = 6). The proposed method has been successfully applied for the analysis of LAS homologues in aqueous environmental samples. A comparison study with ion-pair solid extraction on MWCNTs, C8 and C18 as adsorbents for LAS demonstrated that ion pair-based solid extraction on MWCNTs adsorbent was advantageous over C8 and C18, the widely used traditional adsorbents.  相似文献   

4.
Summary A method for determining aromatic sulfonates in sea water is presented. Ion-pair solid phase extraction is coupled on-line to ion-pair liquid chromatography with UV detection. In the enrichment step, the recoveries from 100 mL of sea water were higher than 65% for most analytes. Linearity was good and detection limits were between 0.02 and 1 μgL−1. The repeatability of the method, expressed as % of relative standard deviation (n=3) was between 1 and 15%. The method was checked in coastal water near the commercial port of Tarragona, where effluents from the petrochemical industry are discharged. All the samples taken were found to contain 2-naphthalenesulfonate.  相似文献   

5.
王雪梅  王娟  杜彤彤  马晓敏  卢小泉 《色谱》2018,36(3):190-194
以石墨烯海绵(GS)为固相萃取材料,建立了固相萃取-高效液相色谱(SPE-HPLC)同时测定化妆品中6种紫外吸收剂的分析方法。样品经甲醇超声提取,用自制的石墨烯海绵固相萃取小柱净化富集,丙酮洗脱。采用Agilent Zorbax SB-C18色谱柱(150 mm×4.6 mm,5 μm)进行分离,甲醇-水(95∶5,v/v)为流动相,紫外检测波长为340 nm。结果表明,6种紫外吸收剂均在各自的范围内线性关系良好,2-(2'-羟基-5'-甲基苯基)苯并三氮唑的相关系数(r) > 0.997,其他5种r > 0.999。方法的检出限(LOD,S/N=3)和定量限(LOQ,S/N=10)分别为0.08~1.82 μg/L和0.26~6.07 μg/L。在20、50和100 μg/L 3个加标水平下,6种目标物的加标回收率为61.1%~119.0%,相对标准偏差(RSD)小于1%(n=6)。该法简便、快速,灵敏度高,重复性好,适用于不同类型化妆品中紫外吸收剂的检测。  相似文献   

6.
Polymer monoliths are promising materials for sample preparation due to their high porosity, pH stability, and simple preparation. The use of melamine formaldehyde foams has been reported as an effective support to prepare highly robust silica and polymer monoliths. Herein, divinylbenzene monoliths based on a 50:50 (%, w/w) crosslinker/porogen ratio have been nested within a melamine-formaldehyde sponge, resulting in monoliths with a surface area higher than 400 m2/g. The extraction performance of these monoliths was evaluated for the extraction of endocrine-disrupting bisphenols from aqueous solutions. We evaluated for the first time the versatility of sponge-nested polymer monoliths by comparing three different extraction modes (vortex mixing, magnetic stirring, and orbital shaking). Vortex mixing showed a comparable recovery of bisphenols (39%–81%) in a shorter extraction time (30 min, instead of 2 h). In addition, the robustness of the sponge-nested polymer monoliths was demonstrated for the first time by reshaping a larger monolithic cube (0.125 cm3) into four smaller pieces (4 × 0.03125 cm3) leading to a 16%–21% increase in extraction efficiency. This effect was attributed to an increase in the effective contact area with the sample, obtaining a higher analyte extraction capacity.  相似文献   

7.
王宁  李永仙  郑飞云  刘春凤  李崎  顾国贤 《色谱》2009,27(3):372-375
采用Waters Sep-Pak C18固相萃取小柱对啤酒样品进行分离纯化,建立了啤酒中黄腐酚的固相萃取-高效液相色谱检测方法。选用色谱柱Zorbax Eclipse XDB-C18柱(250 mm×4.6 mm,5 μm),以甲醇和0.1%甲酸水溶液为流动相进行梯度洗脱,柱温25 ℃,流速0.4 mL/min,检测波长370 nm。在此条件下,黄腐酚分离良好且无杂质峰干扰,在0.5~500 μg/L的范围内线性关系良好(r21),在高、中、低浓度下的加标回收率为91.21%~95.58%,相对标准偏差小于2%。方法的检出限为0.24 μg/L,定量限为0.80 μg/L。该方法简便快速、结果准确、重现性好,是检测啤酒中黄腐酚含量的有效方法。  相似文献   

8.
A method based on on-line solid-phase extraction (SPE) coupling to high-performance liquid chromatography (HPLC) for the determination of estrogens has been developed. This method can continuously perform extraction of estrone, estradiol, estriol and diethylstilbestrol from aqueous samples without any other pretreatment, which can then be analyzed by HPLC with a UV detector at 230 nm. A pre-concentration column was adapted with methanol/water for chromatographic separation and two kinds of sorbents were involved, which are octadecyl-bonded silica and cigarette filter. The condition of pH of samples, sample loading flow rate and desorption time were all optimized, and the performances of both two sorbents were satisfactory. The on-line SPE system requires very low maintenance and just involved a switching-valve-filter system and a flow-inject pump, and the operation of the whole SPE-HPLC instrumentation is quite simple. The detection limits for pre-concentrating 50 mL of standard solution using cigarette filter as sorbent ranged from 0.98 to 78.1 ng L−1. The enhancement factors were in the range of 197-326. The recoveries of estrogens spiked in real water samples ranged from 85 to 112%. The precisions for nine replicate measurements of a standard mixture (5.0 μg L−1) were in the range of 1.0-3.4%.  相似文献   

9.
ABSTRACT

In this work, a low-cost melamine-formaldehyde polymer with large-surface-area mesoporous structure was prepared and applied as an efficient solid sorbent for pre-concentration of five kinds of chlorinated herbicides including fomesafen, atrazine, pyrithiobac-sodium, benazolin and acifluorfene from water samples. Extraction parameters such as pH of the sample solution, amount of mesoporous melamine-formaldehyde polymer (mMFP), extraction time, type of desorption solv-ent and volume of the sample were systematically investigated. Combining dispersive solid-phase extraction with high-performance liquid chromatography (HPLC), the detection limits (S/N = 3) of the five herbicides were ranged from 0.04 to 0.18 μg L?1 with good linearity (R2 ≥ 0.9908). Then the tap water and river water samples were analysed by the developed method, and the obtained results indicated that this method provides acceptable recoveries and precisions. mMFP can be prepared through one-pot catalyst-free polymerisation from low-cost starting materials, so that they could be easily scaled up for the sample pre-treatment and have the powerful potentiality in purification of contaminated water.  相似文献   

10.
The potential of solid-phase extraction (SPE) time-resolved laser-induced fluorimetry (TRLIF) is evaluated for screening polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Octadecyl membranes are used with the dual purpose of extracting the pollutants from the water sample and serving as the solid substrate for fluorescence detection. Excitation of fluorescence is performed with a Nd:YAG pumped tunable dye laser pumped with a pulsed source for time-resolving spectral interference. Wavelength time matrices (WTMs) and real time-resolved fluorescence spectra are recorded with a pulsed delay generator, a spectrograph and an intensified charge-coupled device (ICCD). In comparison to SPE solid-matrix luminescence (SML) with conventional instrumentation, this approach provides better limits of detection (LOD) and selectivity. The improvement in LOD is of one order of magnitude, reaching the parts-per-trillion level with 10 ml of water sample. The improvement in selectivity allows the direct determination of target compounds in complex samples. The direct determination of benzo[a]pyrene from a spiked river water sample of unknown composition is presented.  相似文献   

11.
固相萃取-气相色谱法测定茶叶中残留的92种农药   总被引:13,自引:5,他引:8  
建立了茶叶中92种农药多残留的气相色谱分析方法。茶叶样品用乙腈一次性提取后,有机磷类农药经Envi-Carb固相小柱净化,用10 mL乙腈-甲苯(体积比为3∶1)洗脱剂淋洗,气相色谱-火焰光度检测器(GC-FPD)检测;有机氯类和拟除虫菊酯类农药经串联Envi-Carb和NH2固相小柱净化,用5 mL乙腈-甲苯(体积比为3∶1)洗脱剂淋洗,GC-电子捕获检测器(ECD)检测。采用外标法定量。添加回收试验的结果表明:92种农药的平均回收率为80.3%~117.1%,相对标准偏差为1.5%~9.8%。方法的检出限为0.0025~0.10 mg/kg。该方法的灵敏度、准确度和精密度均符合农药残留测定的技术要求。  相似文献   

12.
Extraction and determination of seven aromatic amines in environmental water samples were performed with solid-phase extraction (SPE) and micellar liquid chromatography (MLC) using experimental design. Extraction of aromatic amines was carried out with a C18 cartridge modified with sodium dodecyl sulphate (SDS). The washing solution and elution solvent for extraction of aromatic amines were aqueous solution containing 5% (v/v) acetonitrile and 5% (v/v) acetone and 3 mL methanol, respectively. The chemometrics approach was applied for the separation optimisation of these compounds using MLC. Different mobile phase compositions were used for modelling based on retention times to obtain the best separation using central composite design. The optimum mobile phase composition for separation and determination of analytes in water samples was 69 mM SDS, 9% v/v 1-propanol and pH = 6.4. Recoveries were between 84.8–93.5% with relative standard deviation (RSD) less than 5.8% (n = 5). Limits of detection and linear range were 1–4.5 and 3.1–125.0 µg/L, respectively. The proposed method was applied to determine the aromatic amines in real samples (river and well waters). Amount of 4-nitroaniline and 3-nitroaniline in river water sample were 2.15 and 1.91 µg/L, respectively.  相似文献   

13.
For a long time, the detection of nitroimidazole antibiotics (NIABs) has been a research focus in environmental analytical chemistry. In this work, a novel technique for the analysis of nitroimidazoles was established based on capillary electrophoresis (CE). UiO-66, synthesized using a solvothermal method, was utilized as an adsorbent in the dispersive solid-phase extraction (DSPE) of five different NIABs. The separation and detection of NIABs in environmental water samples were accomplished using the CE diode array detection method. The optimal extraction conditions were obtained after systematically studying the effects of adsorption time, the amount of extractant, and elution solvent on extraction efficiency. According to the results of the study, the limit of detections of the five NIABs were between 16 and 97 ng/mL, the relative standard deviations were between 0.32% and 0.55%, and the spike recoveries were between 87.43% and 104.8%. This study presents a novel technique for measuring NIABs in complex water samples.  相似文献   

14.
Fluoroquinolones are in the order of the day concerning environmental contamination through anthropogenic activities, resulting in increased risk for antibiotic resistance dissemination. In this context, accessible, low-cost analytical methods are required for implementation of comprehensive surveillance and screening schemes. In this work, we propose a down-scaled disk-based solid-phase extraction system from which the eluate can be first screened by miniaturized fluorimetric reading, followed by individual determination of target fluoroquinolones (ciprofloxacin, norfloxacin, and enrofloxacin) by liquid chromatography combined to tandem mass spectrometry. The fluorimetric measurement is based on the intrinsic fluorescence of fluoroquinolones. Disk-based retention was performed after sample acidification (pH 4.0) by mixed-mode cation exchange using polystyrene divinylbenzene sulphonated sorbent. Sample loading was precisely controlled in a dedicated flow system operating at 4.0 mL min?1. Different eluent compositions were tested, with elution performed by 1.00 mL of methanol-ammonium hydroxide (98:2, v/v), with subsequent reading of eluate in both detectors. Quantification was attained for 2–25 µg L?1 range, with LOD values at 1 µg L?1. The proposed approach was successfully applied to estuarine waters from the Douro River, with comparable results to a conventional SPE-LC-MS/MS procedure.  相似文献   

15.
A simple, rapid and sensitive analytical method was developed for the simultaneous determination of bisphenol A (BPA), bisphenol F (BPF) and their corresponding diglycidyl ethers (BADGE and BFDGE) in wastewater and river water, in order to have a useful tool for evaluating their fate and distribution in aquatic environments. It was based on their extraction with coacervates made up of decanoic acid reverse micelles and subsequent determination by liquid chromatography-fluorimetry. The procedure involved the extraction of 10.8 mL of water sample for 5 min, its centrifugation for 10 min to accelerate phase separation and then the chromatographic analysis of the target compounds. Clean-up or solvent evaporation steps were not necessary to get the required sensitivity and selectivity. Extraction efficiencies and concentration factors mainly depended on the amount of decanoic acid and tetrahydrofuran making up the coacervate. A general equation for the prediction of the volume of the coacervate as a function of its components has been proposed and fitted by nonlinear regression. This equation permits to know a priori the maximum concentration factors that can be achieved under given experimental conditions. Extractions were independent of salt addition (up to 1 M), the temperature (up to 60 °C) and the pH (below 4) rendering the method robust. Recoveries in samples ranged between about 80 and 92% and the actual concentrations factors were between 87 and 102, which resulted in practical detection limits around 30-35 ng L−1. The method was successfully applied to the determination of the target pollutants in raw and treated sewage from four mechanical-biological treatment plants and three rivers. Bisphenols and their diglycidyl ethers were present in wastewater influents at concentrations in the range 0.96 to 1.6 μg L−1. The biological treatment at the wastewater treatment plants (WWTPs) studied reduced the concentration of BPA and BPF in a percentage above 75%, while diglycidyl ethers were not detected in most of the effluents investigated. Only BPA was detected in surface waters.  相似文献   

16.
In this study, an automated on-line solid-phase extraction coupled to fast liquid chromatography–tandem mass spectrometry (on-line SPE fast LC–MS/MS) method was developed for the simultaneous analysis of bisphenol A (BPA), bisphenol F (BPF), bisphenol E (BPE), bisphenol B (BPB) and bisphenol S (BPS) in canned soft drinks without any previous sample treatment. A C18 (12 μm particle size) loading column was used for the SPE on-line preconcentration before the liquid chromatography baseline separation of bisphenol compounds using a C18 Fused-Core™ (50 mm × 2.1 mm i.d.) column, which took less than 3 min. Gradient elution and heated electrospray were used to reduce matrix effect and improve ionization efficiency. To select the most intense and selective transitions, fragmentation studies were performed by multiple-stage mass spectrometry in an ion trap mass analyzer and tandem mass spectrometry in a triple quadrupole instrument, this latter instrument being used for quantitation in SRM mode. Quality parameters of the method were established and we obtained a simple, fast, reproducible (RSD values lower than 10%) and accurate (precision higher than 93%) method for the analysis of bisphenols in canned soft drinks at the ng L−1 level using matrix-matched calibration.  相似文献   

17.
固相萃取-高效液相色谱检测葡萄酒中赭曲霉毒素A   总被引:7,自引:0,他引:7  
使用C18小柱固相萃取, C18反相柱(250 mm×4.6 mm i.d.)分离,V(乙腈):V(水):V(乙酸)=99:99:2为流动相,荧光检测器(激发波长333 nm,发射波长460 nm)检测,测定葡萄酒中赭曲霉毒素A.其质量浓度在6.25~200 ng/mL范围内呈良好线性,相关系数为0.9997.样品经浓缩60倍后,方法检出限为0.027 ng/mL.对红葡萄酒、干红及白葡萄酒进行了加标回收实验,回收率为80.1%~109.8%.平行7份样品加标回收率相对标准偏差为5.9%.对市售6种葡萄酒进行了赭曲霉毒素A的测定.  相似文献   

18.
An efficient magnetic dummy template molecularly imprinted polymer nanocomposite was prepared using multi-walled carbon nanotubes as a support and metolachlor deschloro as a dummy template. The obtained nanocomposites were characterized using Fourier transform infrared spectroscopy, vibrating sample magnetometry, scanning electron microscopy, and transmission electron microscopy. The adsorption performance of the obtained nanocomposites was evaluated through binding experiments, including static adsorption, kinetic adsorption, and selective recognition studies. The obtained nanocomposites were successfully applied as selective sorbents for the magnetic solid-phase extraction of seven amide herbicides (alachlor, acetochlor, pretilachlor, butachlor, metolachlor, diethatyl ethyl, and dimethachlor) coupled with liquid chromatography-tandem mass spectrometry from fish samples. Under the optimized conditions, the limit of detection was 0.01–0.1 μg/kg. The obtained recoveries of the amide herbicides from the fish samples were in the range of 88.0 to 102.1% with a relative standard deviation of less than 7.5%. This method, which eliminated the effect of template leakage on qualitative and quantitative analysis was found to be superior to the methods reported in the literature. The results indicated that it could be successfully applied to analyze amide herbicides in fish samples with satisfactory recoveries.  相似文献   

19.
黄成  姜理英  陈建孟  陈效 《色谱》2008,26(5):618-621
采用固相萃取-衍生化气相色谱/质谱法(GC/MS)测定某制药厂污水中的雌酮(E1)、雌二醇(E2)、雌三醇(E3)和乙炔基雌二醇(EE2)4种雌激素化合物。样品经固相萃取柱萃取富集及双(三甲基硅烷基)三氟乙酰胺(1%三甲基氯硅烷)(BSTFA(1%TMCS))衍生化后进行GC/MS分析。该法对4种目标物的检出限为1.8~4.7 ng/L,相对标准偏差为2.3%~9.1%(n=8)。目标化合物的加标回收率为(94.0±2.9)%~(101±3.8)%,说明该方法能较好地应用于污水中雌激素化合物的定量检测。通过对某制药厂污水中的雌激素进行定量分析,发现污水中乙炔基雌二醇和雌酮质量浓度分别达396.6 和39.9 ng/L;经过传统的厌氧兼氧好氧生物处理后,污水中的环境雌激素的去除率仅为35%~40%,说明传统的污水处理工艺对去除污水中雌激素效果并不明显,需要改进。  相似文献   

20.
Summary The eleven Environmental Protection Agency (EPA) priority phenolic compounds have been determined by solid-phase extraction (SPE) coupled on-line to supercritical-fluid chromatography (SFC) with diodearray detection. The variables affecting chromatographic separation were optimized and the analytes were separated at 40 °C in two diol columns connected in series; a gradient of methanol, as modifier, and CO2 was used as mobile phase. Under these conditions, all the compounds studied were separated to baseline in less than 13 min. PLRP-S and LiChrolut EN were tested as sorbents in a 10×3 mm i.d. laboratory-packed precolumn for solid-phase extraction. An ion-pair reagent, tetrabutylammonium bromide (TBA), was used in the extraction process to increase break-through volumes. The performance of the method was checked with tap and river waters and the pre-concentration of 20 mL of sample in a PLRP-S pre-column enabled phenolic compounds to be determined at low μg L−1 levels with limits of detection ranging between 0.4 and 2 μg L−1. The repeatability and reproducibility between days (n=3) for real samples spiked at 10 μg L−1 were lower than 10%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号