首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
Y Liu  D Cheng  IH Lin  NL Abbott  H Jiang 《Lab on a chip》2012,12(19):3746-3753
Although biochemical sensing using liquid crystals (LC) has been demonstrated, relatively little attention has been paid towards the fabrication of in situ-formed LC sensing devices. Herein, we demonstrate a highly reproducible method to create uniform LC thin film on treated substrates, as needed, for LC sensing. We use shear forces generated by the laminar flow of aqueous liquid within a microfluidic channel to create LC thin films stabilized within microfabricated structures. The orientational response of the LC thin films to targeted analytes in aqueous phases was transduced and amplified by the optical birefringence of the LC thin films. The biochemical sensing capability of our sensing devices was demonstrated through experiments employing two chemical systems: dodecyl trimethylammonium bromide (DTAB) dissolved in an aqueous solution, and the hydrolysis of phospholipids by the enzyme phospholipase A(2) (PLA(2)).  相似文献   

2.
A new fiber-optic prototype of luminometer has been designed in order to perform ratiometric-based measurements for optical sensing purposes. The coupling of a pH-selective sensing phase to the fiber-optic prototype has been evaluated for robust pH optosensing in drinking water. The pH-sensitive material has been synthesized by entrapping a pH-sensitive luminescent indicator (mercurochrome) in a sol-gel inorganic matrix. The pH optosensing is based on the detection of pH-induced reversible changes in the mercurochrome fluorescent emission and in the light reflected by the sensing phase.The instrument has been constructed using low-cost and simple optoelectronic components. The active phase was excited by means of a visible 470 nm high intensity light emitting diode (LED). The radiant power of the LED was modulated using a sinusoidal function so that scattered light due to light sources of different frequency than the modulating signal (e.g. sunlight) can be easily removed by adequate electronic filtering of the emission signal. Both the fluorescence emission from the dye and the sensing phase reflected light were collected in a bifurcated fiber-optic to allow the ratiometric measurement.Two different ratiometric approaches have been evaluated. The analytical performance of the pH optrode using both measurement methods have been compared, between them and with simple fluorescence intensity measurements, in terms of sensitivity, measurement range, response time, repeatability and insensitivity to changes in excitation light intensity.The applicability of the developed pH optrode and methods has been tested for pH analysis in tap and bottled still mineral water samples. The results obtained showed good agreement with the corresponding pH values provided by a commercial glass electrode.In this work, pH was selected as a model analyte to evaluate the performance of the proposed methodology, although other optical sensors for different applications/analytes could benefit of this approach.  相似文献   

3.
An original computer-controlled solid-state photometer has been developed and its potential for simultaneous multicomponent flow-injection analysis of binary and ternary mixtures is demonstrated. The device is simple in construction. Its principle of operation is based on rapid sequential measurements of the absorbance of the complexes formed by the analytes with chromogenic reagents at the wavelengths corresponding to the emission maxima of three light emitting diodes (563, 580 and 638 nm).  相似文献   

4.
Despite the increasing number of usage of molecularly imprinted polymers (MIPs) in optical sensor application, the correlation between the analytical signals and the binding isotherms has yet to be fully understood. This work investigates the relationship between the signals generated from MIPs sensors to its respective binding affinity variables generated using binding isotherm models. Two different systems based on the imprinting of metal ion and organic compound have been selected for the study, which employed reflectance and fluorescence sensing schemes, respectively. Batch binding analysis using the standard binding isotherm models was employed to evaluate the affinity of the binding sites. Evaluation using the discrete bi-Langmuir isotherm model found both the MIPs studied have generally two classes of binding sites that was of low and high affinities, while the continuous Freundlich isotherm model has successfully generated a distribution of affinities within the investigated analytical window. When the MIPs were incorporated as sensing receptors, the changes in the analytical signal due to different analyte concentrations were found to have direct correlation with the binding isotherm variables. Further data analyses based on this observation have generated robust models representing the analytical performance of the optical sensors. The best constructed model describing the sensing trend for each of the sensor has been tested and demonstrated to give accurate prediction of concentration for a series of spiked analytes.  相似文献   

5.
The new optical concepts currently developed in the research field of plasmonics can have significant practical applications for integrated optical device miniaturization as well as for molecular sensing applications. Particularly, these new devices can offer interesting opportunities for optical addressing of quantum systems. In this article, we develop a realistic model able to explore the various functionalities of a plasmon device connected to a single fluorescing molecule. We show that this theoretical method provides a useful framework to understand how quantum and plasmonic entities interact in a small area. Thus, the fluorescence signal evolution from excitation control to relaxation control depending on the incident light power is clearly observed.  相似文献   

6.
For the first time, the combination of multicommutation concept with flow-through multioptosensors is exploited and a biparameter multicommutated UV sensor is developed. A very easy-operated and automated sensing device is proposed here and demonstrated to be useful in the routine analysis by applying it to the determination of two widely used pharmaceuticals chosen as model analytes: salicylamide and caffeine. The particulated solid phase used performs two functions: (a) states selectivity conditions by itself in the flow cell and (b) provides appropriate separation of the analytes in the on-line precolumn, thus making possible the sequential arrival of the analytes to the detection zone. Both carrier and eluting solutions chosen allow (with a very simple solenoid valve configuration and operation) the transitory signals to be developed in a completely automated device. Drastic reduction of carrier and eluting solutions used are achieved as compared to typically FIA optosensor configuration. The sensor responds linearly in the range 2-30 and 1-14 μg ml−1 for SLC and CF, with detection limits of 0.33 and 0.15 μg ml−1, respectively. Solution savings between 50 and 85% were obtained when comparing to typical flow injection analysis (FIA).  相似文献   

7.
A novel optical biochemical sensor based on surface plasmon resonance (SPR) has been developed for immunosensing. The new device is a relatively simple and inexpensive one designed on the basis of fixing angle of incidence and scanning wavelength in the range of 400-800 nm. While the BIAcore SPR sensing method is to fix wavelength and modulate angle of incidence light, which need an expensive and complicated apparatus.  相似文献   

8.
Mu S  Wang X  Li YT  Wang Y  Li DW  Long YT 《The Analyst》2012,137(14):3220-3223
A novel multi-channel electrode array sensing device was fabricated by screen-printing techniques using 96-well plate as the template. To confirm its practical value, we developed a one-step preparation of multi-walled carbon nanotubes (MWCNTs) doped electrode array by an ink containing MWCNTs, which was applied to the simultaneous detection of a variety of biological samples and environmental pollutants. Results demonstrated that the designed sensing device could carry out the multiple measurements of different analytes at the same time, while MWCNTs enhanced the electrocatalytic activity of electrodes toward electroactive molecules. The required amount of each sample was only ~200 μL. Moreover, the excellent differential pulse voltammetric (DPV) response toward dopamine, hydroquinone and catechol was obtained and the detection limits was determined to be 0.337, 0.289 and 0.369 μM, respectively. Comparing it with the traditional screen-printed electrode (SPE), this sensing device possesses the advantages of high-throughput, fast electron transfer rate for electrodes, short-time analysis and low sample consumption.  相似文献   

9.
A novel device, membrane extraction with a sorbent interface (MESI) coupled with a portable gas chromatograph (GC) system, has been developed. The main components of this system include a membrane module, a microtrap, and a control unit for the heater and cooler. The membrane module, as an on-line sample-introduction device for this system, can be manipulated in different configurations, allowing for the selective permeation of analytes across the membrane into the carrier/stripping gas. The analytes are trapped and concentrated onto a microtrap, which serves as an injector for gas chromatography separation. A concentration pulse of the trapped analytes is generated through direct electrical heating of the microtrap. The characteristics of this system have been explored, and its applicability and effectiveness have been demonstrated in field monitoring applications including the analysis of toluene in wastewater, Volatile organic compounds (VOCs) in laboratory air, and chloroform in swimming-pool water. This system is very promising, as it is a simple, fast, and portable tool for on-site process environmental monitoring.  相似文献   

10.
O' Toole M  Lau KT  Diamond D 《Talanta》2005,66(5):1340-1344
A novel inexpensive optical-sensing technique has been developed for colorimetric flow analysis. This sensing system employs two LEDs whereby one is used as the light source and the other as a light detector. The LED used as light detector is reverse biased with a 5-V supply so that the photocurrent generated by the incident light discharges the capacitance. Direct digital output is provided by a simple timer circuit that measures the time taken for this discharge process from 5 V (logic 1) to 1.7 V (logic 0).

This sensing concept has been applied in flow analysis by constructing an optical flow cell with a pair of LEDs. Calibration of the integrated optical flow cell using a dye resulted in a linear response that obeys the Beer–Lambert law. The flow rate, dynamic range, sensitivity and limits of detection were investigated. The system was also used for pH determination in the range of pH 2.5–6.8 using bromocresol green (BCG). The pKa of BCG was successfully determined by this technique.  相似文献   


11.
The development of a chip-based sensor array composed of individually addressable polystyrene-poly(ethylene glycol) and agarose microspheres has been demonstrated. The microspheres are selectively arranged in micromachined cavities localized on silicon wafers. These cavities are created with an anisotropic etch and serve as miniaturized reaction vessels and analysis chambers. A single drop of fluid provides sufficient analysis media to complete approximately 100 assays in these microetch pits. The cavities possess pyramidal pit shapes with trans-wafer openings that allows for both fluid flow through the microreactors/analysis chambers and optical access to the chemically sensitive microspheres. Identification and quantitation of analytes occurs via colorimetric and fluorescence changes to receptor and indicator molecules that are covalently attached to termination sites on the polymeric microspheres. Spectral data are extracted from the array efficiently using a charge-coupled device allowing for the near-real-time digital analysis of complex fluids. The power and utility of this new microbead array detection methodology is demonstrated here for the analysis of complex fluids containing a variety of important classes of analytes including acids, bases, metal cations, metabolic cofactors, and antibody reagents.  相似文献   

12.
Surface enhanced Raman spectroscopy (SERS) is a powerful optical sensing technique that can detect analytes of extremely low concentrations. However, the presence of enough SERS probes in the detection area and a close contact between analytes and SERS probes are critical for efficient acquisition of a SERS signal. Presented here is a light‐powered micro/nanomotor (MNM) that can serve as an active SERS probe. The matchlike AgNW@SiO2 core–shell structure of the nanomotors work as SERS probes based on the shell‐isolated enhanced Raman mechanism. The AgCl tail serves as photocatalytic nanoengine, providing a self‐propulsion force by light‐induced self‐diffusiophoresis. The phototactic behavior was utilized to achieve enrichment of the nanomotor‐based SERS probes for on‐demand biochemical sensing. The results demonstrate the possibility of using photocatalytic nanomotors as active SERS probes for remote, light‐controlled, and smart biochemical sensing on the micro/nanoscale.  相似文献   

13.
The suitability of an integrated optical chemical sensor for the determination of highly volatile chlorinated hydrocarbons in aqueous solutions has been proven. The analytes are detected by NIR absorption spectrometry in the evanescent field of an integrated optical strip waveguide generated in a BGG31 (Schott, Germany) glass substrate, which is coated with a hydrophobic polymer superstrate as sensing layer. It has been shown that the sensitivity increases when the refractive index of the superstrate is increased from 1.333 up to 1.46. Different UV-cured polysiloxanes with low cross sensitivity to water have been prepared. Due to the good light transmission properties of the IO-sensors prepared by this method, quantitative measurements have been performed with the model system trichloroethene (TCE) in water. A detection limit of 22 ppm has been found and the sensor response times (t(90)-value) are between five and fourteen minutes for a coating thickness of around 30 microm. The sensor response is totally reversible. The analyte desorbes in air within 2 min. The enrichment of trichloroethene in the polysiloxane coating can be described by film diffusion through the aqueous boundary layer as rate determining step.  相似文献   

14.
An optical waveguiding sensor array featuring monolithically integrated organic photodiodes as integrated photo-detector, which simplifies the readout system by minimizing the required parts, is presented. The necessity of any optical filters becomes redundant due to the proposed platform geometry, which discriminates between excitation light and sensing signal. The sensor array is capable of measuring luminescence or absorption, and both sensing geometries are based on the identical substrate. It is demonstrated that background light is virtually non-existent. All sensing and waveguide layers, as well as in- and out-coupling elements are assembled by conventional screen-printing techniques. Organic photodiodes are integrated by layer-by-layer vacuum deposition onto glass or common polymer foils. The universal and simple applicability of this sensor chip is demonstrated by sensing schemes for four different analytes. Relative humidity, oxygen, and carbon dioxide are measured in gas phase using luminescence-based sensor schemes; the latter two analytes are also measured by absorbance-based sensor schemes. Furthermore, oxygen and pH in aqueous media were enabled. The consistency of calibration characteristics extending over different sensor chips is verified.
Figure
Integrated fluorescence (left) and absorbance (right) based sensor waveguide  相似文献   

15.
We present for the first time an electrowetting on dielectric (EWOD) microfluidic system coupled to a surface-assisted laser desorption-ionization (SALDI) silicon nanowire-based interface for mass spectrometry (MS) analysis of small biomolecules. Here, the transfer of analytes has been achieved on specific locations on the SALDI interface followed by their subsequent mass spectrometry analysis without the use of an organic matrix. To achieve this purpose, a device comprising a digital microfluidic system and a patterned superhydrophobic/superhydrophilic silicon nanowire interface was developed. The digital microfluidic system serves for the displacement of the droplets containing analytes, via an electrowetting actuation, inside the superhydrophilic patterns. The nanostructured silicon interface acts as an inorganic target for matrix-free laser desorption-ionization mass spectrometry analysis of the dried analytes. The proposed device can be easily used to realize several basic operations of a Lab-on-Chip such as analyte displacement and rinsing prior to MS analysis. We have demonstrated that the analysis of low molecular weight compounds (700 m/z) can be achieved with a very high sensitivity (down to 10 fmol μL(-1)).  相似文献   

16.
Z Zhou  K Wang  X Yang  S Huang  L Zhou  D Qin  L Du 《The Analyst》2001,126(11):1838-1840
A novel method for the synchronization of separation and determination is described, in which a mode-filtered light detector is used as an online detector in capillary electrophoresis. An instrument is described which has been developed for this purpose. The round capillary used in conventional capillary electrophoresis is replaced by an annular column, which is constructed from a naked optical fibre inserted into a fused-silica capillary. In fact, the annular electrophoresis column itself forms part of the mode-filtered light sensor. Along the side of the annular column are several detection channels for gathering and transmitting the mode-filtered light to a charge-coupled device (CCD). Every channel provides information on the sample from the point at which it is located. Using capillary isotachophoresis incorporating the annular column, the analytes in a sample containing alanine (10.0 mM) and glycine (9.7 mM) were simultaneously separated and determined using multichannel mode-filtered light detection with a detection limit of 1.5 mM.  相似文献   

17.
Novel fused-LEDs devices as optical sensors for colorimetric analysis   总被引:1,自引:0,他引:1  
The development of a novel, low power optical sensing platform based on light emitting diodes (LEDs) is described. The sensor is constructed from a pair of LEDs fused together at an angle where one LED functions as the light source and the other LED is reverse biased to function as a light detector. Sensor function is based on the level of light received by the detector diode, which varies with the reflectance of the interface between the device and its environment, or the chemochromic membrane that covers the device. A simple microprocessor circuit is used to measure the time taken for the photon-induced current to discharge the detector LED from an initial 5 V (logic 1) to 1.7 V (logic zero). This sensing device has been successfully used for colour and colour-based pH measurements and offers extremely high sensitivity, enabling detection down to the sub micro molar level of dyes.  相似文献   

18.
A novel “turn-off” fluorescence, smart hydrogel sensor for detection of a nerve agent simulant has been developed and tested. The smart hydrogel chemosensor has demonstrated an extremely fast and select fluorescence quenching detection response to the Sarin simulant diethylchlorophosphate (DCP) in the aqueous and vapor phases. The fluorogenic sensor utilizes 6,7-dihydroxycoumarin embedded in an polyacrylamide hydrogel matrix as the fluorescent sensing material. The rapid fluorescence quenching of the smart hydrogel films could easily be observed with the naked eye using a hand-held UV light at λ = 365 nm which demonstrates their practical application in real-time on-site monitoring.  相似文献   

19.
Optical simulations of a liquid crystal biosensor device are performed using an integrated optical/textural model based on the equations of nematodynamics and two optical methods: the Berreman optical matrix method [J. Opt. Soc. Am. 62, 502 (1972)] and the discretization of the Maxwell equations based on the finite difference time domain (FDTD) method. Testing the two optical methods with liquid crystal films of different degrees of orientational heterogeneities demonstrates that only the FDTD method is suitable to model this device. Basic substrate-induced texturing process due to protein adsorption gives rise to an orientation correlation function that is nearly linear with the transmitted light intensity, providing a basis to calibrate the device. The sensitivity of transmitted light to film thickness, protein surface coverage, and wavelength is established. A crossover incident light wavelength close to lambda(co) approximately 500 nm is found, such that when lambda>lambda(co) thinner films are more sensitive to the amount of protein surface coverage, while for lambda相似文献   

20.
The gas sensing behaviors of cobalt phthalocyanine (CoPc) and metal-free phthalocyanine (H2Pc) thin films were investigated with respect to analyte basicity. Chemiresistive sensors were fabricated by deposition of 50 nm thick films on interdigitated gold electrodes via organic molecular beam epitaxy (OMBE). Time-dependent current responses of the films were measured at constant voltage during exposure to analyte vapor doses. The analytes spanned a range of electron donor and hydrogen-bonding strengths. It was found that, when the analyte exceeded a critical base strength, the device responses for CoPc correlated with Lewis basicity, and device responses for H2Pc correlated with hydrogen-bond basicity. This suggests that the analyte-phthalocyanine interaction is dominated by binding to the central cavity of the phthalocyanine with analyte coordination strength governing CoPc sensor responses and analyte hydrogen-bonding ability governing H2Pc sensor responses. The interactions between the phthalocyanine films and analytes were found to follow first-order kinetics. The influence of O2 on the film response was found to significantly affect sensor response and recovery. The increase of resistance generally observed for analyte binding can be attributed to hole destruction in the semiconductor film by oxygen displacement, as well as hole trapping by electron donor ligands.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号