首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Poly(acrylamide-1-allyl-2-thiourea) hydrogels, Poly(AAm-ATU), were synthesized by gamma irradiation using a 60Co γ source at different irradiation dose rates and in a monomer mixture with different 1-allyl-2-thiourea contents. These hydrogels were used for the specific gold recovery from single and competitive media. It was observed that the gold adsorption capacity onto the hydrogels was high at low pHs and reached a maximum value at pH 0.5. It was found that the adsorption capacity of the hydrogels for gold ions in acidic media around pH 0.5 was high and about 940 mg g−1 dry hydrogel. Adsorption of these hydrogels for gold ions was found to be very fast and also these hydrogels were showed extremely high selectivity to the gold ions in acidic media even when the concentrations of the other metal ions were extremely higher than that of the gold. Because of the high specificity of these hydrogels to gold ions compared with the other metal ions at low pHs, all matrix effects could be easily eliminated by adsorbing gold ions onto the hydrogels at around pH 0.5 and desorbing into 0.8 M thiourea in 3.0 M HCl. The swellability of the synthesized hydrogels varied with irradiation dose rates and increased at high irradiation dose rates. The minimum swellability of the hydrogels was found to be at least 1000% which made it attractive for gold to penetrate into the hydrogels and react with all the functional groups in the interior surface of the hydrogels.  相似文献   

2.
An electrochemical preconcentration at a controlled potential on the electrode in a flow-through mode followed by graphite furnace atomic absorption spectrometric (GFAAS) detection is proposed for determination of trace amounts of palladium. After electrolysis the polarization of the electrodes was changed and deposited metal was dissolved electrochemically in the presence of an appropriate stripping reagent. Conditions for the electrodeposition, such as pH of the solutions, a deposition potential, dissolution potential and a composition of stripping solution were optimised. The graphite electrode (GE) and glassy carbon electrode (GCE) were tested for the palladium reduction process. The detection limit of 0.05 ng ml−1 Pd (1 pg) was obtained after palladium preconcentration on the GCE and dissolution with 0.2 mol l−1 thiourea in 0.1 mol l−1 HCl followed by GFAAS detection. The method was applied for the determination of palladium in spiked tap water and road dust samples.  相似文献   

3.
Poly((N-(Hydroxymethyl)methacrylamide)–1-allyl-2-thiourea) hydrogels, Poly(NHMMA–ATU), were synthesized by gamma radiation using 60Co γ source at different irradiation doses and different ATU content in the irradiated monomer mixture. The swellability of the synthesized hydrogels was changed by irradiation doses and by the content of ATU in the irradiated mixture. These hydrogels were used for the specific gold recovery and pre-concentration from single gold ion solutions and from different natural samples. It has been observed that gold adsorption capacity onto the hydrogels was high at low pHs and reached maximum value at pH = 0.5. Adsorption capacity of the hydrogels for gold at pH = 0.5 was found to be about 698 mg g− 1 dry hydrogels. Adsorption equilibrium time of gold ions onto the hydrogels was found to be very short and also these hydrogels were showed extremely high selectivity to the gold ions in acidic media when the concentration of the other metal ions were extremely higher than gold. Because of the high specificity of these hydrogels to gold beside the other metal ions at low pHs, all matrix effects were easily eliminated adsorbing gold onto the hydrogels and desorbing into 3 M HCl solution containing 0.8 M thiourea. These hydrogels were found to be highly open pore size. This property of the hydrogels make them attractive due to high adsorption capacity of gold ions on/in the hydrogels penetrating inside and react to all functional groups in the interior surface of the hydrogels.  相似文献   

4.
Sawula GM 《Talanta》2004,64(1):80-86
Microcolumns containing 8-hydroxyquinoline azo-immobilized on controlled pore glass were incorporated in a field sampler for on-site collection, isolation and preconcentration of trace metal ions in waters of the Okavango Delta, Botswana. Sequestered trace metal ions were recovered by elution with 0.5 ml of 1.5 M nitric acid, and determined by graphite furnace atomic absorption spectrometry (GFAAS). This sampling and enrichment method minimizes sample contamination, and collection of large volumes of water samples for transporting, over long distances, to analytical laboratories is avoided.Data reported comprise one of the initial surveys on trace metal ion concentrations in waters of the Okavango Delta, Botswana. In waters with more efficient mixing, dissolved metal ion concentrations found were generally low with slightly elevated levels of manganese (7-19 μg l−1), zinc (2.7-4.8 μg l−1), nickel (0.2-2.5 μg l−1) and copper (0.3-2.1 μg l−1). For each trace metal ion, concentration levels seem to reflect zones of varying water conveyance, and show no obvious temporal and spatial variations apart from a slight increment from the inlet in the upper Delta to the outlets in the lower Delta.  相似文献   

5.
The present paper proposes a pre-concentration procedure for determination of lead and iron in several samples by flame atomic absorption spectrometry. In it, lead(II) and iron(III) ions are coprecipitated using the violuric acid-copper(II) system as collector. Afterwards, the precipitate is dissolved with 1 M HNO3 solution and the metal ions are determined. The optimization step was performed using factorial design involving the variables: pH, violuric acid mass (VA) and copper concentration (Cu).Using the optimized experimental conditions, the proposed procedure allows the determination these metals with detection limits of 0.18 μg L−1 for iron and 0.16 μg L−1 for lead. The effects of foreign ions on the pre-concentration procedure were also evaluated and the results demonstrated that this method could be applied for determination of iron and lead in several real samples. The proposed method was successfully applied to the analysis of seawater, urine, mineral water, soil and physiological solution samples. The concentrations of lead and iron achieved in these samples agree well with others data reported in the literature.  相似文献   

6.
A new method that utilizes ethylenediamine-modified activated carbon (AC-EDA) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) prior to the measurement by inductively coupled plasma optical emission spectrometry (ICP-OES). The new sorbent was prepared by oxidative surface modification. Experimental conditions for effective adsorption of trace levels of Cr(III), Fe(III), Hg(II) and Pb(II) were optimized with respect to different experimental parameters using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4.0. Complete elution of absorbed metal ions from the sorbent surface was carried out using 3.0 mL of 2% (%w/w) thiourea and 0.5 mol L−1 HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.4, 28.9, 60.5 and 49.9 mg g−1 for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The time for 94% adsorption of target metal ions was less than 2 min. The detection limits of the method was found to be 0.28, 0.22, 0.09 and 0.17 ng mL−1 for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The precision (R.S.D.) of the method was lower 4.0% (n = 8). The prepared sorbent as solid-phase extractant was successfully applied for the preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) in natural and certified samples with satisfactory results.  相似文献   

7.
Chelex-100, Dowex 50W-x8 and Dowex MAC-3 exchange resins were investigated for separation and pre-concentration of trace amounts of Cd, Cr, Cu, Fe, Mn, Pb, Ti and Zn in alcohols with respect to retention and desorption characteristics. Dowex 50W-x8 was found to be the best sorbent with percentages recoveries >95%. In addition, Chelex-100 appeared to be suitable for the pre-concentration of Cu, Fe and Zn, whereas Dowex MAC-3 was selective for Cu and Fe. Therefore, Dowex 50W-x8 was used for further investigations. The relative standard deviations <4% (n = 20), limits of detection and quantification were 0.1–1.2 μg L−1 and 0.3–1.5 μg L−1, respectively. The SPE method was validated against a certified reference material and the results were in agreement with certified values. The accuracy of the optimized method was verified by the recovery test in the spiked alcohol samples. The accuracy and spike recovery test for different metal ions were in the range 98–102% and 95–105%, respectively. The optimized method was applied to the separation and pre-concentration of metal ions in different commercial alcohol samples.  相似文献   

8.
《Microchemical Journal》2007,85(1-2):80-87
Poly((N-(Hydroxymethyl)methacrylamide)–1-allyl-2-thiourea) hydrogels, Poly(NHMMA–ATU), were synthesized by gamma radiation using 60Co γ source at different irradiation doses and different ATU content in the irradiated monomer mixture. The swellability of the synthesized hydrogels was changed by irradiation doses and by the content of ATU in the irradiated mixture. These hydrogels were used for the specific gold recovery and pre-concentration from single gold ion solutions and from different natural samples. It has been observed that gold adsorption capacity onto the hydrogels was high at low pHs and reached maximum value at pH = 0.5. Adsorption capacity of the hydrogels for gold at pH = 0.5 was found to be about 698 mg g 1 dry hydrogels. Adsorption equilibrium time of gold ions onto the hydrogels was found to be very short and also these hydrogels were showed extremely high selectivity to the gold ions in acidic media when the concentration of the other metal ions were extremely higher than gold. Because of the high specificity of these hydrogels to gold beside the other metal ions at low pHs, all matrix effects were easily eliminated adsorbing gold onto the hydrogels and desorbing into 3 M HCl solution containing 0.8 M thiourea. These hydrogels were found to be highly open pore size. This property of the hydrogels make them attractive due to high adsorption capacity of gold ions on/in the hydrogels penetrating inside and react to all functional groups in the interior surface of the hydrogels.  相似文献   

9.
Poly(p-chloromethylstyrene-ethyleneglycoldimethacrylate) polymeric microbeads, poly(p-CMS-EGDMA), were synthesized and 1,5,9,13-tetrathiacyclohexadecane-3,11-diol (S4HD) was attached chemically onto the polymeric microbeads. Characterization of all microbeads was done by Fourier transform-infrared spectrometry (FT-IR) and elemental analyzer. The amount of attached 1,5,9,13-tetrathiacyclohexadecane-3,11-diol to the polymer was found to be 2.23 mmol g−1 polymers. The ligand attached microbeads, poly(p-CMS-EGDMA-S4HD), were used to examine the adsorption capacity of Pb(II), Cd(II), Hg(II) and Cr(II) ions for recovery, pre-concentration and the matrix elimination by changing the pH and the initial metal ion concentrations and also adsorption kinetics of the studied metal ions was determined. Pre-concentration factors for the studied toxic metal ions were found to be more than 500-fold and recovery was between 92 and 106%. In the drinking, lake, tap and sea-water samples from water lands, ultra-trace toxic metal ion concentrations were determined easily by using ligand modified microbeads after pre-concentration because of the high pre-concentration factor and easily matrix elimination using ligand modified microbeads. Reference sea-water material was used for the validation of the method and it was found that recovery, pre-concentration and the matrix elimination were performed perfectly. For the desorption of the toxic metal ions, 3 M HCl containing 0.8 M thiourea was used and desorption ratio was obtained more than 96%.  相似文献   

10.
The use of selective pre-concentration and differential pulse anodic stripping voltammetry (DPASV) using a carbon paste electrode modified (CPEM) with spinel-type manganese oxide has been proposed for the determination of lithium ions content in natural waters. The new procedure is based on the effective pre-concentration of lithium ions on the electrode surface containing spinel-type Mn(IV) oxide with the reduction of Mn(IV) to Mn(III) and consequently the lithium ions intercalation (insertion) into the spinel structure. The best DPASV response was reached for an electrode composition of 25% (m/m) spinel-type MnO2 in the paste, 0.1 mol l−1 tris(hydroxymethyl)aminomethane (TRIS) buffer solution of pH 8.3, scan rate of 5 mV s−1, accumulation potential of 0.3 V versus saturated calomel reference electrode (SCE), pre-concentration time of 30 s and potential pulse amplitude of 50 mV. In these experimental conditions, the proposed methodology responds to lithium ions in the concentration range of 2.8×10−6 to 2.0×10−3 mol l−1 with a detection limit of 5.6×10−7 mol l−1. The determination of the lithium ions content in different samples of natural waters samples using the proposed methodology and atomic absorption spectrophotometry are in agreement at the 95% confidence level and within an acceptable range of error.  相似文献   

11.
The nickel-aluminum layered double hydroxide (Ni-Al LDH) was synthesized by a simple co-precipitation method and used as a solid-phase extraction (SPE) sorbent for separation and pre-concentration of trace levels of salicylic acid (SA) from aqueous solutions. Extraction of analyte is based on the adsorption of salicylate ions on the Ni-Al (NO3) LDH and/or their exchanging with LDH interlayer NO3 ions. The retained analyte on the LDH was stripped by 3 mol L−1 NaOH solution and its concentration was subsequently determined spectrofluorometrically at λem = 400 nm with excitation at λex = 270 nm. Various parameters affecting the extraction efficiency of SA on the Ni-Al (NO3) LDH, such as pH, amount of nano-sorbent, sample loading flow rate, elution conditions, sample volume and matrix effects were investigated. In the optimum experimental conditions, the limit of detection (3 s) and enrichment factor were 0.12 μg L−1 and 40, respectively. The relative standard deviation (RSD) for six replicate determinations of 10 μg L−1 SA was 2.3%. The calibration graph using the pre-concentration system was linear in the range of 0.3-45 μg L−1 with a correlation coefficient of 0.9985. The optimized method was successfully applied to the determination of SA in blood serum, willow leaf and aspirin tablet.  相似文献   

12.
The examination of the effect of interfering ions on the analytical signal of ruthenium measured by electrothermal atomic absorption spectrometry was initially performed in this work. The complexes of ruthenium(III) with thiosemicarbazide (TSd) and acetaldehyde thiosemicarbazone (AcTSn) were prepared and imprinted in polymeric network. The ion-imprinted polymers were synthesized by copolymerization of methacrylic acid, as functional monomer and ethylene glycol dimethacrylate, as crosslinking agent in the presence of 2,2-azobisisobutyronitrile as initiator. The effects of sample volume, pH, and flow rate on the extraction of analyte were studied in dynamic mode. The optimum pH for quantitative retention of ruthenium on each of the studied sorbents was 7.5 ± 0.5. The elution of analyte was completed with 0.2 mol L−1 thiourea in 0.2 mol L−1 HCl. The effect of matrix ions on ruthenium(III) separation process was studied. The analytical performance of the Ru-TSd polymer in the presence of competing ions was better than Ru-AcTSn polymer, considering recovery of analyte, reproducibility of results, selectivity coefficients, and sorbent capacity. The detection limit of the proposed method (0.16 ng mL−1 on Ru-TSd and 0.25 ng mL−1 on Ru-AcTSn) is lower in comparison with the previously published methods. The developed separation method was successfully applied to the determination of trace amounts of ruthenium in spiked water samples, sludge, grass, and human hair.  相似文献   

13.
Rapid surface oxidation of a metal was carried out using a low voltage (9-18 V dc) power supply to examine the feasibility of low power electrocorrosion as an alternative to current metal sampling techniques such as acid digestion. Potential was applied between a metal alloy and a cellulose electrode that was made conductive using an aqueous solution (NH4NO3, KCl). Metal ions diffuse into the cellulose as rapid surface oxidation of the metal occurs. The metal ions can then be extracted and analyzed using atomic spectroscopy (e.g. GFAAS). Steel (316L, SRM 663), brass and aluminum alloys were electro-corroded using constant potential. At short intervals (<2 min) the mass of corroded metal increased linearly with time. Corrosion rates for Cr, Ni, Cu and Mn ranged from 870 to 34 pg s−1. The mass of metal corroded increased as applied potential/current increased and depends on the surface area of the cellulose-metal contact. Experiments showed that preferential metal corrosion does not occur in steel samples. SEM images show that there is a relatively large area (∼1 mm2) of homogenous corrosion and that the most damage occurs closest to the edge of filter paper/metal contact. Low power electrocorrosion was used to identify metals in a fork of unknown composition. Multiple techniques (GFAAS, FAAS and SN-ICP-MS) were used for analysis and it was found that Ag and Cu were the primary metals in the alloy, in a ratio of 3:1. Trace amounts of other metals (<1%) were found but not quantified.  相似文献   

14.
Chaozhang Huang 《Talanta》2007,73(2):274-281
Mesoporous titanium dioxide as a novel solid-phase extraction material for flow injection micro-column preconcentration on-line coupled with ICP-OES determination of trace metals (Co, Cd, Cr, Cu, Mn, Ni, V, Ce, Dy, Eu, La and Yb) in environmental samples was described. Possessing a high adsorption capacity towards the metal ions, mesoporous titanium dioxide has found to be of great potential as an adsorbent for the preconcentration of trace metal ions in samples with complicated matrix. The experimental parameters including pH, sample flow rate, volume, elution and interfering ions on the recovery of the target analytes were investigated, and the optimal experimental conditions were established. Under the optimized operating conditions, a preconcentration time of 90 s and elution time of 18 s with enrichment factor of 10 and sampling frequency of 20 h−1 were obtained. The detection limits of this method for the target elements were between 0.03 and 0.36 μg L−1, and the relative standard deviations (R.S.D.s) were found to be less than 6.0% (n =7, c =5 ng mL−1). The proposed method was validated using a certified reference material, and has been successfully applied for the determination of the afore mentioned trace metals in natural water samples and coal fly ash with satisfactory results.  相似文献   

15.
A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L−1 HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g−1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL−1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n = 8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.  相似文献   

16.
A new chelating resin based on chitosan biopolymer modified with 5-sulphonic acid 8-hydroxyquinoline using the spray drying technique for immobilization is proposed. The chelating resin was characterized by thermogravimetric analysis (TGA) and X-ray diffraction (XRD) and surface area by nitrogen sorption. The efficiency of the chelating resin was evaluated by the preconcentration of metal ions Cu(II) and Cd(II) present in aqueous samples in trace amounts. The metal ions were previously enriched in a minicolumn and the concentrations of the analytes were determined on-line by flame atomic absorption spectrometry (FAAS). The maximum retention for Cu(II) occurred in the pH range 8-10, and for Cd(II) at pH 7. The optimum flow rate for sorption was found to be 7.2 ml min−1 for the preconcentration of the metal ions. The analytes gave relative standard deviations (R.S.D.) of 0.7 and 0.6% for solutions containing 20 μg l−1 of Cu(II) and 15 μg l−1 of Cd (II), respectively (n=7). The enrichment factors for Cu(II) and Cd (II) were 19.1 and 13.9, respectively, and the limits of detection (LOD) were 0.2 μg l−1 for Cd(II) and 0.3 μg l−1 for Cu(II), using a preconcentration time of 90 s (n=11). The accuracy of the proposed method was evaluated by the metal ion recovery technique, in the analysis of potable water and water from a lake, with recoveries being between 97.2 and 107.3%.  相似文献   

17.
A new and simple method was developed for preconcentration trace amount of gold in aqueous and mineral samples. The method was based on the sorption of gold on granular activated carbon (AC) in acidic medium (hydrochloric acid) and subsequently direct determination by graphite furnace atomic absorption spectrometry (GFAAS). A small particle of adsorbent was delivered to small volume of sample. After extraction, AC removed and analyzed directly by GFAAS. Several factors influencing the extraction efficiency, such as the hydrochloric acid concentration, sample volume and extraction time were studied as well as effect of potential interfering ions. The preconcentration factor 50 was obtained. The limit of detection (LOD) of gold in water and soil samples was 0.007 μg L− 1 and 0.9 ng g− 1, respectively. The proposed method was applied successfully to the determination of trace amount of gold in environmental and geological samples. In order to validate the developed method, two certified reference materials: Platinum Ore (SARM-7B) and Copper Ore Mill Heads (No. 330) were analyzed and the determined values obtained were in good agreement with the certified values and recovery was obtained in the range of 80-118%. The relative standard deviations (RSD) for the spiking levels of 0.5 μg L− 1 in the real samples was 4%, (n = 15).  相似文献   

18.
Silica gel was firstly functionalized with aminopropyltrimethoxysilane obtaining the aminopropylsilica gel (APSG). The APSG was reacted subsequently with curcumin yielding curcumin-bonded silica gel (curcumin-APSG). This new bonded silica gel was used for separation, pre-concentration and determination of Cu(II), Fe(III), Zn(II) in biological and natural water samples by inductively coupled plasma optical emission spectrometry (ICP-OES). Experimental conditions for effective adsorption of trace levels of metal ions were optimized with respect to different experimental parameters using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the newly sorbent was 4.0. Complete elution of the adsorbed metal ions from the sorbent surface was carried out using 2.0 mL of 0.1 mol L− 1 of HCl. Common coexisting ions did not interfere with the separation and determination at pH 4.0. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 0.63, 0.46 and 0.37 mmol g− 1 for Cu(II), Fe(III) and Zn(II) respectively. The time for 95% sorption for Cu(II) Fe(III) and Zn(II) was less than 2 min. The detection limits of the method defined by IUPAC was found to be 0.12, 0.15 and 0.40 ng mL− 1 for Cu(II), Fe(III) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was lower 3.0% (n = 5). The procedure was validated by analyzing the certified reference river sediment material (GBW 08301, China), the results obtained were in good agreement with standard values. This sorbent was successfully employed in the separation and pre-concentration of trace Cu(II), Fe(III) and Zn(II) from the biological and natural water samples yielding 75-fold concentration factor.  相似文献   

19.
An off-line extraction chromatographic technique has been developed using Amberlite XAD-16 (AXAD-16)-N,N-dihexylcarbamoylmethyl phosphonic acid, as the stationary phase for the extraction of uranium, thorium and lanthanum from nuclear spent fuels as well as from geological and natural water resources. The chemical modifications of the polymeric matrix were monitored using FT-IR spectroscopy, CHNPS elemental analysis and also by thermo gravimetric analysis for water regain measurements. Various physio-chemical parameters influencing the quantitative metal ion extraction by the resin phase were optimized by both static and dynamic methods. The developed resin matrix showed good distribution ratio values under wide concentrations of acidity and pH conditions. Moreover, the sequential separation of analytes is also possible at sample pH 6.5. Also, the polymeric matrix showed superior metal sorption capacities and rapid metal exchange kinetics with a high sample flow rate value of 26 cm3 min−1 for all the three analytes. Thus, reducing the time of analyte extraction from large number of samples anticipated in nuclear waste management programs. The quantitative metal ion recovery of >99.8% was effected with 0.5 M (NH4)2CO3 solution. The method was highly sensitive with lower limits of detections to be 10, 20 and 15 ng cm−3 for U(VI), Th(IV) and La(III), respectively, with a better pre-concentration values of 333 for U(VI) and Th(IV) and 400 for La(III), respectively paving way for its applicability in pre-concentrating trace analytes from large sample volumes. The analytical data were within 4.2% R.S.D. reflecting the reproducibility and reliability of the developed method.  相似文献   

20.
The potential of multiwalled carbon nanotubes (MWNTs) as solid-phase extraction adsorbent for the separation and preconcentration of gold has been investigated. Gold could be adsorbed quantitatively on MWNTs in the pH range of 1–6, and then eluted completely with 2 mL of 3% thiourea in 1 mol L− 1 HCl solution at a flow rate of 0.5 mL min− 1. A new method using a microcolumn packed with MWNTs as sorbent has been developed for the preconcentration of trace amount of Au prior to its determination by flame atomic absorption spectrometry. Parameters influencing the preconcentration of Au, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been examined and optimized. Under the optimum experimental conditions, the detection limit of this method for Au was 0.15 µg L− 1 with an enrichment factor of 75, and the relative standard deviation (R.S.D) was 3.1% at the 100 µg L− 1 Au level. The method has been applied for the determination of trace amount of Au in geological and water samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号