1.
Silva SG  Rocha FR 《Talanta》2010,83(2):559-564
A flow system designed with solenoid micro-pumps is proposed for fast and greener spectrophotometric determination of free glycerol in biodiesel. Glycerol was extracted from samples without using organic solvents. The determination involves glycerol oxidation by periodate, yielding formaldehyde followed by formation of the colored (3,5-diacetil-1,4-dihidrolutidine) product upon reaction with acetylacetone. The coefficient of variation, sampling rate and detection limit were estimated as 1.5% (20.0 mg L−1 glycerol, n = 10), 34 h−1, and 1.0 mg L−1 (99.7% confidence level), respectively. A linear response was observed from 5 to 50 mg L−1, with reagent consumption estimated as 345 μg of KIO4 and 15 mg of acetylacetone per determination. The procedure was successfully applied to the analysis of biodiesel samples and the results agreed with the batch reference method at the 95% confidence level.  相似文献   

2.
An ion mobility spectrometer equipped with an ultraviolet lamp was used for the qualitative and quantitative determination of acetone in urine samples. This analyte can be used as a biomarker for some fat metabolism-related diseases in humans and cows. Samples require no pretreatment other than warming at 80 °C for 5 min, after which an N2 stream is used to drive volatile analytes to the ion mobility spectrometer. The precision of the ensuing method, expressed as relative standard deviation (%RSD), is better in all cases than 6.7% for peak height and calculated at three levels of concentration. The analyte concentration range studied was from 5 to 80 mg L−1, its limit of detection in the aqueous matrix 3 mg L−1 and recoveries from spiked urine samples 109 ± 3%. The calculated reduced mobility for acetone in the urine samples, 1.75 ± 0.04 cm2 V−1 s−1, was similar to previously reported values. Also, the results were consistent with those provided by test strips used for reference. The proposed method provides a new vanguard screening system for determining acetone in urine samples.  相似文献   

3.
Melchert WR  Rocha FR 《Talanta》2005,65(2):461-465
Nitrate determination in waters is generally carried out with cadmium filings and carcinogenic reagents or by reaction with phenolic compounds in highly concentrated sulfuric acid medium. In this work, it was developed a green analytical procedure for nitrate determination in natural waters based on direct spectrophotometric measurements in ultraviolet, using a flow-injection system with an anion-exchange column for separation of nitrate from interfering species. The proposed method employs only one reagent (HClO4) in a minimum amount (equivalent to 18 μL concentrated acid per determination), and allowed nitrate determination within 0.50-25.0 mg L−1, without interference of up to 200.0 mg L−1 humic acid; 1.0 mg L−1 NO2; 200.0 mg L−1 PO43−; 75.0 mg L−1 Cl; 50.0 mg L−1 SO42− and 15.0 mg L−1 Fe3+. The detection limit (99.7% confidence level) and the coefficient of variation (n = 20) were estimated as 0.1 mg L−1 and 0.7%, respectively. The results obtained for natural water samples were in agreement with those achieved by the reference method based on nitrate reduction with copperized cadmium at the 95% confidence level.  相似文献   

4.
A simple, automatic and practical system for successive determination of albumin and creatinine has been developed by combining sequential injection analysis (SIA) and highly sensitive dye-binding assays. Albumin detection was based on the increase in the absorbance due to complex formation between albumin and eosin Y in acidic media. The absorbance of the complex was monitored at 547 nm. For the creatinine assay, the concentration of creatinine was measured by reaction with alkaline picrate to form a colored product which absorbs at 500 nm. The influences of experimental variables such as effects of pH, reagent concentration, standard/sample volume and interferences were investigated. Under optimal conditions, the automated method showed linearity up to 20 mg L−1 for albumin and 100 mg L−1 for creatinine. The 3σ detection limits were 0.6 and 3.5 mg L−1 for albumin and creatinine, respectively, and the relative standard deviations (n = 10) were 2.49% for 20 mg L−1 albumin, and 3.14% for 20 mg L−1 creatinine. Application of the proposed method to the direct analysis of urinary samples yielded results which agreed with those obtained from the Bradford protein assay and a creatinine enzymatic assay according to a paired t-test. The results obtained should be a step towards developing a fully automated and reliable analytical system for clinical research, which requires direct determination of albumin and creatinine and/or its ratios.  相似文献   

5.
A spectrophotometric method was developed to quantify low polysorbate (PS) levels in biopharmaceutical formulations containing high protein concentrations. In the method, Oasis HLB solid phase extraction (SPE) cartridge was used to extract PS from high protein concentration formulations. After loading a sample, the cartridge was washed with 4 M guanidine HCl and 10% (v/v) methanol, and the retained PS was eluted by acetonitrile. Following the evaporation of acetonitrile, aqueous cobalt-thiocyanate reagent was added to react with the polyoxyethylene oxide chain of polysorbates to form a blue colored PS–cobaltothiocyante complex. This colored complex was then extracted into methylene chloride and measured spectrophotometrically at 620 nm. The method performance was evaluated on three products containing 30–40 mg L−1 PS-20 and PS-80 in ≤70 g L−1 protein formulations. The method was specific (no matrix interference identified in three types of protein formulations), sensitive (quantitation limit of 10 mg L−1 PS) and robust with good precision (relative standard deviation ≤6.4%) and accuracy (spike recoveries from 95% to 101%). The linear range of the method for both PS-20 and PS-80 was 10 to 80 mg L−1 PS. By diluting samples with 6 M guanidine HCl and/or using different methylene chloride volumes to extract the colored complexes of standards and samples, the method could accurately and precisely quantify 40 mg L−1 PS in up to 300 g L−1 protein formulations.  相似文献   

6.
Tang Y  Wu M 《Talanta》2005,65(3):794-798
A method of quickly determining ascorbic acid and sorbic acid by capillary zone electrophoresis with ultraviolet detection was developed. The choice of background electrolyte, wavelength, injection time and applied voltage were discussed. Ascorbic acid and sorbic acid were well separated in 80 mmol L−1 boric acid-5 mmol L−1borax (pH = 8.0) in 5 min at the detecting wavelength of 270 nm. Under the optimum condition, the method has linear ranges of 2.54-352.00 mg L−1 for ascorbic acid and 1.08-336.39 mg L−1 for sorbic acid with the detection limit of 1.70 mg L−1 for ascorbic acid and 0.54 mg L−1 for sorbic acid, respectively. Other organic acids in fruit juices have no effect on the detection. This method is very feasible and simple and can be used to detect ascorbic acid and sorbic acid in fruit juices.  相似文献   

7.
In this work, a solid phase spectrophotometric method in association with flow injection analysis for formaldehyde determination has been developed with direct measurement of light-absorption in C18 material. The 3,5-diacetyl-1,4-dihydrolutidine produced from the reaction between formaldehyde and fluoral P was quantitatively retained on C18 support and the spectrophotometric detection was performed simultaneously at 412 nm. The retained complex was quickly eluted from C18 material with the eluent stream consisting of a 50% (v/v) ethanol solution. The results showed that the proposed method is simple, rapid and the analytical response is linear in the concentration range of 0.050-1.5 mg L−1. The limit of detection was estimated as 30 μg L−1 and the R.S.D. 2.2% using a sample volume of 625 μL. The system presented an analytical throughput of 20 determinations per hour. The method was successfully applied in the determination of formaldehyde in ethanol fuel.  相似文献   

8.
A sequential injection analysis (SIA) using lab-on-valve with air segmentation and spectrophotometric detection was designed for copper(II) determination. It is based on the reaction of copper(II) and 2-carboxy-2′-hydroxy-5′-sulfoformazyl benzene (Zincon) in a weak alkaline solution between the air zones. Beer's Law was obeyed over the range of 0.1-2.0 mg L−1 copper(II) with a correlation coefficient 0.9985 and a slope of 0.2893 absorbance unit/mg L−1. The relative standard deviation was 2.0% for a series of 10 measurements of 0.5 mg L−1 copper(II) solution. The detection limit (3 S/N) and the limit of quantification (LOQ) were 0.05 and 0.17 mg L−1 respectively. This method has been successfully applied to determination of copper(II) in wastewater with a sample throughput of 120 h−1. The method is superior to the batchwise method in that it provides fully automation, rapidity, less reagents and sample consumption with little waste generation.  相似文献   

9.
Dielectric barrier discharge (DBD) at atmospheric pressure provides an efficient radiation source for the excitation of bromine and it is used for the first time for optical emission spectrometric (OES) detection of bromide and bromate. A portable DBD–OES system is developed for screening potential pollution from bromide and bromate in environmental waters. Bromide is on-line oxidized to bromine for in-situ generation of volatile bromine. Meanwhile, a helium stream carries bromine into the DBD micro-plasma for its excitation at a discharging voltage of 3.7 kV and optical emission spectrometric detection with a QE65000 charge-coupled device (CCD) spectrometer in the near-infrared spectral region. Similarly, the quantification of bromate is performed by its pre-reduction into bromide and then oxidized to bromine. The spectral characteristics and configuration of the DBD micro-plasma excitation source in addition to the oxidation vapor generation of bromine have been thoroughly investigated. With a sampling volume of 1 mL, a linear range of 0.05–10.0 mg L−1 is obtained with a detection limit of 0.014 mg L−1 by measuring the emission at 827 nm. A precision of 2.3% is achieved at 3 mg L−1 bromide. The system is validated by bromine detection in certified reference material of laver (GBW10023) at mg L−1 level, giving rise to satisfactory agreement. In addition, it is further demonstrated by screening trace bromide and bromate as well as spiking recoveries in a series of environmental water samples.  相似文献   

10.
Two miniature and compact optoelectronic devices fabricated by means of integration of light emitting diodes have been developed for turbidimetric and nephelometric measurements. These devices are operating according to paired-emitter-detector-diode (PEDD) principle. The detectors have been characterized using bovine serum albumin and Exton protein assay as a model analyte and a model analytical method, respectively. The developed detectors have been adapted for measurements under conditions of flow injection analysis (FIA). Under optimized conditions the turbidimetric flow system offers the range of linear response up to 400 mg L−1 with the detection limit at 20 mg L−1. The linear range and detection limit found for optimized nephelometric FIA system are 15–500 mg L−1 and 8 mg L−1, respectively. The PEDD-based FIA systems with the detector operating according to both modes of measurements have been successfully applied for urinalysis offering total protein determination at physiological and pathological levels with high throughput (over 60 injections per hour).  相似文献   

11.
The paper presents a new method for a simultaneous determination of inorganic nitrogen species in the oxidized (NO2, NO3) and reduced (NH4+) form in rain water samples. The method is based on a system of nitrogen species separation employing ion exchange and diode-array detection. The ions are separated in a strong ion-exchanger, nitrites and nitrates are determined directly at 208 and 205 nm, respectively, while the ammonium ions are determined in the column hold-up time after a post-column derivatization by the Nessler reagent, at 425 nm. The use of a diode-array detector permits a simultaneous identification of the inorganic nitrogen species in 8 min. The detection limits obtained are: NO2, 0.1 mg L−1; NO3, 0.05 mg L−1; NH4+, 1 mg L−1. The method proposed has been successfully used for speciation analysis of inorganic nitrogen in precipitation.  相似文献   

12.
This text presents a novel method for the separation and detection of phosphorothioate oligonucleotides with the use of ion pair ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry The research showed that hexafluoroisopropanol/triethylamine based mobile phases may be successfully used when liquid chromatography is coupled with such elemental detection. However, the concentration of both HFIP and TEA influences the final result. The lower concentration of HFIP, the lower the background in ICP-MS and the greater the sensitivity. The method applied for the analysis of serum samples was based on high resolution inductively coupled plasma mass spectrometry. Utilization of this method allows determination of fifty times lower quantity of phosphorothioate oligonucleotides than in the case of quadrupole mass analyzer. Monitoring of 31P may be used to quantify these compounds at the level of 80 μg L−1, while simultaneous determination of sulfur is very useful for qualitative analysis. Moreover, the results presented in this paper demonstrate the practical applicability of coupling LC with ICP-MS in determining phosphorothioate oligonucleotides and their metabolites in serum within 7 min with a very good sensitivity. The method was linear in the concentration range between 0.2 and 3 mg L−1. The limit of detection was in the range of 0.07 and 0.13 mg L−1. Accuracy varied with concentration, but was in the range of 3%.  相似文献   

13.
This work reports a new sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection, confirmation and quantification of forty-six pesticides and transformation products belonging to different chemical classes in wines. The proposed method makes use of a solid-phase extraction (SPE) procedure with Oasis HLB cartridges that combines isolation of the pesticides and sample clean-up in a single step. Analysis is performed by liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-MS/MS) operated in the selected reaction monitoring (SRM) mode, acquiring two specific precursor-product ion transitions per target compound. An investigation of matrix effects has been performed during method validation showing medium to low effects for the majority of the compounds. Limits of detection (LODs) were in the range 0.0003–0.003 mg L−1 and limits of quantification (LOQs) were in the range 0.001–0.01 mg L−1. The average recoveries, measured at two concentration levels (0.010 and 0.050 mg L−1), were in the range 70–110% for most of the compounds tested with % relative standard deviations below 20%, while a value of 0.010 mg L−1 has been established as the method limit of quantification (MLOQ) for all target species. Expanded uncertainty values were in the range 10–40% while the Horrat ratios were below 1. The method has been successfully applied to the analysis of 60 wine samples in the course of an annual monitoring study with carbendazim-benomyl, thiophanate-methyl and carbaryl being the most frequently determined pesticides.  相似文献   

14.
The usefulness of the secondary line at 252.744 nm and the approach of side pixel registration were evaluated for the development of a method for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The influence of side pixel registration on the sensitivity and linearity was investigated by measuring at wings (248.325, 248.323, 248.321, 248.329, and 248.332 nm) of the main line for Fe at 248.327 nm. For the secondary line at 252.744 nm or side pixel registration at 248.325 nm, main lines for Cu (324.754 nm), Mn (279.482 nm) and Zn (213.875 nm), sample flow-rate of 5.0 mL min−1 and calibration by matrix matching, analytical curves in the 0.2-1.0 mg L−1 Cu, 1.0-20.0 mg L−1 Fe, 0.2-2.0 mg L−1 Mn, 0.1-1.0 mg L−1 Zn ranges were obtained with linear correlations better than 0.998. The proposed method was applied to seven soil samples and two soil reference materials (IAC 277; IAC 280). Results were in agreement at a 95% confidence level (paired t-test) with reference values. Recoveries of analytes added to soil extracts containing 0.15 and 0.30 mg L−1 Cu, 7.0 and 14 mg L−1 Fe, 0.60 and 1.20 mg L−1 Mn, 0.07 and 0.15 mg L−1 Zn, varied within the 94-99, 92-98, 93-101, and 93-103% intervals, respectively. The relative standard deviations (n = 12) were 2.7% (Cu), 1.4% (Fe - 252.744 nm), 5.7% (Fe - 248.325 nm), 3.2% (Mn) and 2.8% (Zn) for an extract containing 0.35 mg L−1 Cu, 14 mg L−1 Fe, 1.1 mg L−1 Mn and 0.12 mg L−1 Zn. Detection limits were 5.4 μg L−1 Cu, 55 μg L−1 Fe (252.744 nm), 147 μg L−1 Fe (248.325 nm), 3.0 μg L−1 Mn and 4.2 μg L−1 Zn.  相似文献   

15.
Poachanee Norfun 《Talanta》2010,82(1):202-207
A reverse flow injection analysis (rFIA) spectrophotometric method has been developed for the determination of aluminium(III). The method was based on the reaction of Al(III), quercetin and cetyltrimethylammonium bromide (CTAB), yielding a yellow colored complex in an acetate buffer medium (pH 5.5) with absorption maximum at 428 nm. The rFIA parameters that influence the FIA peak height have been optimized in order to obtain the best sensitivity and minimum reagent consumption. A linear relationship between the relative peak height and Al(III) concentrations were obtained over the concentration range of 0.02-0.50 mg L−1 with a correlation coefficient of 0.9998. The limit of detection (LOD, defined as 3σ) and limit of quantification (LOQ, defined as 10σ) were 0.007 and 0.024 mg L−1, respectively. The repeatability was 1.10% (n = 11) for 0.2 mg L−1 Al(III). The proposed method was applied to the determination of Al(III) in tap water samples with a sampling rate of 60 h−1. Results obtained were in good agreement with those obtained by the official ICP-MS method at the 95% confidence level.  相似文献   

16.
An indirect fluoride determination method has been developed based on the ICP-AES determination of excess cerium(III) ion after precipitation. From four cations—Y(III), Sr(II), Ce(III), La(III)-cerium(III) proved to be the best precipitate forming cation in the 0-20 mg L−1 fluoride concentration range with the limit of detection of 1.4 mg L−1. The precision (RSD) of the proposed method is 0.71% at 8 mg L−1 fluoride. The role of sulphate ions in the formation of the fluoride precipitate was studied as well. The applicability of the technique for the study of solid hazardous wastes as well as for groundwater monitoring of a fluoride contaminated area is demonstrated.  相似文献   

17.
18.
A simple chiral high-performance liquid chromatography (HPLC) method with ultraviolet (UV) and circular dichroism (CD) detection was developed and validated for measuring benalaxyl enantiomers using (R,R) Whelk-O 1 column. The effects of mobile phase composition and column temperature on the entioseparation were investigated. A CD detector was used to determine the elution order of the enantiomers. Excellent resolution was easily obtained using n-hexane-polar organic alcohols mobile phase. The chiral recognition mechanism was also discussed. Based on the developed chiral HPLC method, enantioselective analysis methods for this fungicide in environment matrix (soil and water) were developed and validated. Good linearities were obtained over the concentration range of 0.25-25 mg L−1 for both enantiomers. Liquid-liquid extraction and solid phase extraction (SPE) were used for the enrichment and cleanup of soil and water samples. Recoveries for the two enantiomers were 79-91% at 0.02, 0.04 and 0.2 mg kg−1 levels from soil, and 89-101% at 0.0025, 0.01 and 0.05 mg L−1 levels from water. Run-to-run and day-to-day assay precisions were below 10% for both enantiomers at concentrations of 0.5, 1 and 5 mg L−1. Individual detection limits of the two enantiomers were both 2 ng. Limits of detection (LOD) were 0.004 mg kg−1 in soil and 0.001 mg L−1 in water.  相似文献   

19.
Mycophenolic acid (MPA) is an immunosuppressant drug which powerfully inhibits lymphocyte proliferation. Since the early 1990s it has been used to prevent rejection in organ transplantation. The requirement of therapeutic drug monitoring shown in previous studies raises the necessity of acquiring accurate and sensitive methods to measure MPA and its major metabolite mycophenolic acid glucuronide (MPAG).The authors developed a sample cleanup-free, rapid, and highly specific method for simultaneous measurement of MPA and MPAG in human plasma and serum using the novel technology of ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry. MPA- and MPAG-determinations were performed during a 2.0-min run time. Multiple calibration curves for the analysis of MPA and MPAG exhibited consistent linearity and reproducibility in the range of 0.05-100 (r > 0.999) mg L−1 and 4-4000 mg L−1 (r > 0.999), respectively. Limits of Detection were 0.014 mg L−1 for MPA and 1.85 mg L−1 for MPAG. Lower Limits of Quantification were 0.05 mg L−1 for MPA and 2.30 mg L−1 for MPAG. Interassay imprecision was <10% for both substances. Mean recovery was 103.6% (range 78.1-129.7%) for MPA and 111.1% (range 73.0-139.6%) for MPAG. Agreement was good for MPA and MPAG between the presented method and a validated HPLC-MS/MS method. The Passing-Bablok regression line for MPA and MPAG was HPLC-MS/MS = 1.14 UPLC-MS/MS—0.14 [mg L−1], r = 0.96, and HPLC-MS/MS = 0.77 UPLC-MS/MS + 0.50 [mg L−1], r = 0.97, respectively. This sample cleanup-free and robust LC-MS/MS assay facilitates the rapid, accurate and simultaneous determination of MPA and MPAG in human body fluids.  相似文献   

20.
The construction and evaluation of a Low Temperature Co-fired Ceramics (LTCC)-based continuous flow potentiometric microanalyzer prototype to simultaneously monitor the presence of two ions (potassium and nitrate) in samples from the water recycling process for future manned space missions is presented. The microsystem integrates microfluidics and the detection system in a single substrate and it is smaller than a credit card. The detection system is based on two ion-selective electrodes (ISEs), which are built using all-solid state nitrate and potassium polymeric membranes, and a screen-printed Ag/AgCl reference electrode. The obtained analytical features after the optimization of the microfluidic design and hydrodynamics are a linear range from 10 to 1000 mg L−1 and from 1.9 to 155 mg L−1 and a detection limit of 9.56 mg L−1 and 0.81 mg L−1 for nitrate and potassium ions respectively.  相似文献   