首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Artemisinin is an antimalarial drug containing an internal endoperoxide linkage in its structure. A simple, selective and sensitive high-performance liquid chromatography (HPLC)-peroxyoxalate chemiluminescence (PO-CL) method for the determination of artemisinin was developed. This method is based on the fact that endoperoxide in artemisinin structure can be converted to hydrogen peroxide (H(2)O(2)) under ultraviolet (UV) irradiation and the generated hydrogen peroxide can be measured using PO-CL detection. The HPLC-PO-CL system was optimized on a mobile phase, post column chemiluminescence reagent, UV source and irradiation time. In addition, the system was combined with simple liquid-liquid extraction using n-hexane that allowed selective and sensitive determination of artemisinin in serum. The limit of detection using 0.5 mL of blood was 0.062 micromol/L (17.5 ng/mL) at a signal-to-noise ratio of 3. Calibration curve obtained for artemisinin in human serum 4-80 micromol/L (1.1-22.6 microg/mL) showed a good linearity (r = 0.999).  相似文献   

2.
A sensitive, selective and reliable method has been developed and validated for the determination of halofantrine and its metabolite desbutylhalofantrine in rat plasma using 9,10-diphenylanthracene as an internal standard. The method is based on peroxyoxalate chemiluminescence detection of hydrogen peroxide produced from fused aromatic rings in the structures of halofantrine and desbutylhalofantrine upon UV irradiation. Using spiked rat plasma, good linear relationships were obtained for both halofantrine and desbutylhalofantrine between peak height ratios (vs internal standard) and their corresponding concentrations over a range of 0.01-0.8 microg/mL with correlation coefficients of at least 0.997. The detection limits at signal-to-noise ratio of 3 using 0.2 mL of rat plasma were 1.5 and 1.4 ng/mL for halofantrine and desbutylhalofantrine, respectively. Relative standard deviations (n = 3) intra- and inter-day were between 0.5 and 5.4% for all the studied concentrations. Using this method with simple sample treatment, halofantrine and desbutylhalofantrine in rat plasma could be precisely determined without interference from endogenous substances. The method was successfully applied to the measurement of the time courses of plasma halofantrine concentration after oral administration of the drug (7 mg/kg) to rats.  相似文献   

3.
Summary The combination of an ion-pair extraction detection system with peroxyoxalate chemiluminescence detection has been investigated. Ion-pairs of protonated tertiary amines with a chemiluminescent counter ion are on-line post-column extracted to 1,2-dichloroethane containing bis(2,4,6-trichlorophenyl)oxalate (TCPO). Hydrogen peroxide is added to the organic phase by means of a solid-state perhydrit reactor. The influence of the base catalyst (imidazole) on the chemiluminescence reaction in apolar solvents was studied. Some sulfonated chemiluminophores were compared with respect to their chemiluminescence, ion-pairing and extraction properties, and 5-dimethylaminonaphthalene-1-sulfonate was found to be the most suitable reagent. The detection limit of the potential drug secoverine is in the sub-nanogram range.  相似文献   

4.
Sandmann  B. W.  Grayeski  M. L. 《Chromatographia》1994,38(3-4):163-167
Summary A detection scheme based upon peroxyoxalate chemiluminescence, which utilizes two post-column pumps and two stages of depressurization is investigated. The chemiluminescent detection limit for perylene is 23 times lower than determined by fluorescence, and is in the attomole range. This detection technique is investigated for packed column supercritical fluid chromatography (SFC). Due to the interface design used and the chemical band narrowing effects of chemiluminescence, an apparent increase in efficiency is observed. The interface design affords a wide range of pressures to be used for a separation. During pressure programming the column effluent changes flow rate. Because of a back-pressure regulator, the reaction and detection take place at nearly constant pressure. Therefore pressure gradient work is possible without concern for post-column reagent solubility (which is a concern for high-performance liquid chromatography). The effects of the expanded CO2 from the SFC on the chemiluminescence signal and background are studied. The post-column detection is optimized for pH, photomultiplier voltage, concentrations and flow rates of the peroxide and oxalate ester.  相似文献   

5.
Yonghua Sun  Zhijun Xi  Zuolong Shi 《Talanta》2009,79(3):676-1696
A simple and sensitive liquid chromatographic method coupled with electrogenerated chemiluminescence (ECL) was described for the separation and quantification of naproxen in human urine. The method was based on the ECL of naproxen in basic NaNO3 solution with a dual-electrode system. Factors affected the ECL emission were investigated. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of naproxen in the range of 4.0 × 10−8 g mL−1 to 2.0 × 10−6 g mL−1 and the detection limit was 1.6 × 10−8 g mL−1 (S/N = 3). Application of the method to the analyses of naproxen in human urine proved feasible.  相似文献   

6.
Summary A very simple high-performance liquid chromatographic method for determination of Vitamin A in pharmaceutical preparations without the need for saponification was developed. A reversed-phase (Nova-Pack C18, 4 m) column was used with a mobile phase of acetonitrile-tetrahydrofuran-water (55378) and a flowrate of 1.5 ml/min. Sample treatment only consisted of the extraction of retinol acetate content from capsules or tablets with methanol. Total extraction was achieved by shaking vigorously with the aid of magnetic stirring for three hours at room temperature. No change of solvent is necessary to introduce the sample in the chromatographic system. This method is suitable for routine quantification of Vitamin A.  相似文献   

7.
Estradiol extracted with an ODS minicolumn from serum (500 μl) is derivatized with 5-dimethylamino-1-naphthalenesulfonyl (dansyl) chloride at room temperature for 80 min, purified on the ODS minicolumn, separated on silica gel columns (150 × 1.9 mm i.d. and 100 × 1.9 mm i.d.) with n-hexane/chloroform/ethanol (70:30:0.1) as eluent at 3 ml min?1 and detected by the chemiluminescence emission produced in a post-column reaction with bis-(2,4,6-trichlorophenyl) oxalate (8 mM in chloroform containing 100 mM triethylamine) and hydrogen peroxide (600 mM in methanol containing 6% (v/v) sodium acetate buffer at pH 4.0). The overall recovery of estradiol from serum is ca. 90% and the detection limit is ca. 50 pg.  相似文献   

8.
A modified preparation of sample was developed for the determination of glutathione content in grape juice and wine by high-performance liquid chromatography with fluorescence detection, using on-line pre-column derivatization. Ice-cold deoxygenated methanol was used to deactivate the oxidation enzymes in juices or wines and keep the glutathione stable. The optimum recovery of glutathione content in grape juice and wine was obtained when either the sample of grape juice or wine was mixed in ice-cold deoxygenated methanol in the ratio 10:90 (v:v) and further diluted in sodium acetate buffer in the ratio 1:1 (v:v). The optimized method was validated for linearity, limit of detection, limit of quantification, precision and uncertainty. According to the validation data the method is appropriate for the determination of glutathione content in grape juice and wine. Glutathione contents in grape juices made from White Muscat grapes and Sauvignon Blanc wines were analysed. The average glutathione content in 28 young Sauvignon Blanc wines was 12.5 mg L−1.  相似文献   

9.
Zhang Y  Zhang Z  Qi G  Sun Y  Wei Y  Ma H 《Analytica chimica acta》2007,582(2):229-234
The determination of indomethacin (INM) in pharmaceutical and biological samples by means of high-performance liquid chromatography (HPLC) with in situ electrogenerated Mn(III) chemiluminescence (CL) detection was proposed. The method was based on the direct CL reaction of INM and Mn(III), which was in situ electrogenerated by constant current electrolysis. The chromatographic separation was carried out on Nucleosil RP-C18 column (250 mm × 4.6 mm; i.d., 5 μm; pore size, 100 Å) at 20 °C. The mobile phase consisted of methanol:water:acetic acid = 67:33:0.1 solution. At a flow rate of 1.0 mL min−1, the total run time was 10 min. The effects of several parameters on the HPLC resolution and CL emission were studied systematically. Under the optimal conditions, a linear range from 0.01 to 10 μg mL−1(R2 = 0.9991), and a detection limit of 8 ng mL−1 (signal-to-noise ratio = 3) for INM were achieved. The relative standard deviations (R.S.D.) for 0.1 μg mL−1 INM were 2.2% within a day (n = 11) and 3.0% on 5 consecutive days (n = 6), respectively. The recovery of INM from urine samples was more than 92%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

10.
Summary A new, rapid, sensitive, and specific method for the determination of methoxsalen in dosage forms using HPLC has been developed. methoxsalen is extracted in chloroform, evaporated on a water bath, and the residue is redissolved in ethanol. A standard solution of khellin (internal standard) in ethanol is added, and injected. A plot of peak height ratio (methoxsalen/internal standard) vs. concentration of methoxsalen gave a straight line (r=0.998). The column used was a stainless steel, 3.8 mm×30 cm, and the mobile phase was methanol: water (6040) at a flow rate of 2 cm3/min. Retention times for methoxsalen and khellin were 3.45 and 9.6 min, respectively. This method was found superior to the spectrophotometric assay in that no interference was encountered from structurally similar compounds or from coloring agents used in some commercial methoxsalen products.  相似文献   

11.
Summary The development of a computer-aided rapid-scanning detector for HPLC based on the linear photodiode array UV-visible spectrophotometer is described. Chomatograms monitored at up to three wavelengths, with automatic capture of spectra for eluted peaks and post-run processing of spectral data to generate log10 (A) spectra, second derivative and fourth derivative spectra, are described. Methods are reported for the analysis of forensic samples of diacetylmorphine (heroin) in the presence of the degradation products and potential contaminants caffeine, papaverine, 6-acetylcodeine, thebaine, 6-acetyl-morphine, procaine and morphine separated by HPLC. The novel use of second and higher derivative spectra for the qualitative characterisation of drugs and contaminants separated by HPLC is described.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

12.
A method was developed for the determination of polyamines (PA) by high-performance liquid chromatography with chemiluminescence detection. It is based on the unsaturated complex of PA with Cu(II) which had a strong catalytic effect on the luminol-H2O2 chemiluminescence reaction. The separation of PA was carried out on a reveres phase C18 column using methanol/water (25/75, v/v) as a mobile phase. The method was applied to the analysis of putrescine and the total amount of spermine and spermidine in apple leaves and strawberry fruit. The results indicated that the method is practical and useful.  相似文献   

13.
S Higashidate  K Imai 《The Analyst》1992,117(12):1863-1868
A highly sensitive method for determination of the plasma catecholamines, norepinephrine (NE), epinephrine (E) and dopamine (DA) is described. The method consists of the extraction of the catecholamines, using 3,4-dihydroxybenzylamine as internal standard, from plasma with alumina (5 mg), followed by a reversed-phase column separation, on-column fluorogenic derivatization with ethylenediamine (ED) and post-column peroxyoxalate chemiluminescent reaction detection utilizing bis[4-nitro-2-(3,6,9-trioxadecyl-oxycarbonyl)phenyl] oxalate (TDPO) and hydrogen peroxide. In order to optimize the reaction conditions for high-performance liquid chromatography to obtain highly sensitive detection, the effects of changing reagent compositions on the chemiluminescence yield were investigated. The following are the optimized conditions. Eluent, a mixture of 50 mmol l-1 potassium acetate (pH 3.20)-50 mmol l-1 potassium phosphate (pH 3.20)-acetonitrile (90.15 + 4.85 + 3 v/v/v) containing 1 mmol l-1 sodium hexanesulfonate (40 degrees C) and flow rate, 0.5 ml min-1. Fluorogenic reagent solution, 105 mmol l-1 ED and 175 mmol l-1 imidazole in acetonitrile-ethanol (90 + 10 v/v) and flow rate, 0.25 ml min-1. Reaction coil (15 m x 0.5 mm i.d.) heated at 80 degrees C. Chemiluminogenic reagent solution, 0.25 mmol l-1 TDPO, 150 mmol l-1 hydrogen peroxide and 110 mmol l-1 trifluoroacetic acid in dioxane-ethyl acetate (50:50 v/v) and flow rate, 1.4 ml min-1. The detection limits for all the catecholamines were 1 fmol (signal-to-noise ratio at 2). The standard deviations of the method for the determination of NE, E and DA added to rat plasma (2.5 nM) were 3, 3 and 4%, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
A combination of the electrophoretically mediated microanalysis methodology with a partial filling technique was applied for the inhibition study of bovine liver rhodanese by 2-oxoglutarate. In this set-up, part of the capillary is filled with the best buffer for the enzymatic reaction, while the rest of the capillary is filled with the optimal background electrolyte for separation of substrates and products. The estimated value of KI for 2-oxoglutarate was 3.62·10−4±1.43·10−4 M with respect to cyanide and 1.40·10−3±1.60·10−4 M with respect to thiosulfate. In addition, the type of inhibition was also evaluated. The findings of 2-oxoglutarate as the competitive inhibitor with respect to cyanide and as the uncompetitive inhibitor with respect to thiosulfate are in accordance with previous literature data.  相似文献   

15.
固相萃取-高效液相色谱电化学法检测大鼠血浆儿茶酚胺   总被引:2,自引:3,他引:2  
建立了一种Oasis HLB固相萃取-高效液相色谱(HPLC)电化学检测大鼠血浆儿茶酚胺(CAs)的方法。血浆样本在形成二苯基硼酸-儿荼酚胺复合物后经优化的固相提取技术,得到较高样本回收率。以Atlantis C18色谱柱为固定相,确定了各种影响色谱的参数,如流动相组成、pH范围及检测器的设定。儿茶酚胺所有组分肾上腺素(E)、去甲肾上腺素(NE)和多巴胺(DA)的平均提取回收率在90%~95%之间。E、NE和DA的质量浓度在0.25~30ng/mL时与峰面积呈良好的线性关系(r值分别为0.9989,0.9992和0.9984);检出限为0.4pg。该法灵敏、准确、重现性好、结果可靠。  相似文献   

16.
S. Ito  T. Kato  K. Fujita 《Chromatographia》1986,21(11):645-647
Summary 5-S-Cysteinyldopamine, a new metabolite of dopamine, was determined in urine by high-performance liquid chromatography with electrochemical detection. The catechol was detected in 14 of 21 melanoma patients and 7 of 21 normal subjects; the highest values were 657 μg/day for melanoma patients and 44 μg/day for normal subjects. These results suggest that the cysteine conjugate may arise from autoxidation of dopamine but tyrosinase may also participate in the oxidation.  相似文献   

17.
Vitamin K is a fat-soluble vitamin involved in blood coagulation and bone metabolism. The detection and monitoring of vitamin K homologues in rheumatoid arthritis (RA) patients is a challenging problem due to the smaller concentrations of vitamin K and the presence of several interfering medications. Therefore, this study aimed to develop a new highly sensitive and selective chemiluminescence (CL) method designated to quantify vitamin K homologues in plasma of RA patients including phylloquinone (PK, vitamin K1), menaquinone-4 (MK-4, vitamin K2) and menaquinone-7 (MK-7, vitamin K2). The method was based on the unique photochemical properties of vitamin K homologues that were exploited for selective luminol CL reaction. The correlation coefficients of 0.998 or more were obtained in the concentration ranges of 0.1-100 ng mL−1 vitamin K homologues. The detection limits were 0.03-0.1 ng mL−1 in human plasma for vitamin K homologues. The developed HPLC-CL system was successfully applied for selective determination of vitamin K homologues in plasma of RA patients. The developed method may provide a useful tool for monitoring vitamin K homologues in different clinical studies such as RA, osteoporosis and hepatocellular carcinoma in which vitamin K is intervented.  相似文献   

18.
A highly sensitive high-performance liquid chromatographic method with fluorescence detection has been developed for determination of vitamin B1. Vitamin B1 was converted into a fluorescent compound by treatment with hydrogen peroxide–horseradish peroxidase and the derivative was subsequently analyzed by HPLC on a Waters Spherisorb ODS2 column (250 mm×4.6 mm ID, 5 μm) with 40:60 methanol–pH 8.5 acetate buffer solution as mobile phase and fluorescence detection at 440 nm (with excitation at 375 nm). The calibration graph was linear from 5.00×10−10 mol L−1 to 5.00×10−7 mol L−1 for vitamin B1 with a correlation coefficient of 0.9991 (n=9). The detection limit was 1.0×10−10 mol L−1. The method was successfully used for determination of vitamin B1 at pg mL−1 levels in microalgal fermentation media and seawater after solid-phase extraction. Recovery was from 89 to 110% and the relative standard deviation was in the range 1.1 to 4.3%.  相似文献   

19.
In the present work, an analytical method for determination of risedronate, a member of bisphosphonates, is described for the routine analysis in rat plasma. Sample pre-treatment involves protein precipitation, co-precipitation with calcium at alkaline pH, hydrolysis of possible derivatives of pyrophosphate and reprecipitation. A good separation was obtained by using a reversed-phase column (Hypersil ODS-2 C18, 4.6 mm × 250 mm, 5 μm). The mobile phase was an aqueous solution of buffer (contained 1.5 mM EDTA-2Na, 1 mM sodium etidronate, 11 mM sodium phosphate and 5 mM tetrabutylammonium bromide as ion-pair reagent) - methanol (88:12, v/v) adjusted to pH 6.75 using 1 M NaOH. The flow rate was 1 ml min−1. UV detection (λ = 262 nm) was used to quantitate risedronate in the concentration range of 10-500 ng ml−1. The limit of detection and quantitation for risedronate were 7 and 10 ng ml−1, respectively. The method was applied successfully to plasma samples from Wistar rats undergoing oral administration of risedronate mini-pills. Precision, extraction recoveries, as well as accuracy results, were satisfactory and no interference was found at the retention time of risedronate. Hence, the method is suitable for monitoring risedronate in rat plasma.  相似文献   

20.
In this work, a stable electrogenerated chemiluminescence (ECL) detector was developed. The detector was prepared by packing cation-exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)32+ can be compensated by adding a small amount of Ru(bpy)32+ into solution phase. Coupled with high-performance liquid chromatography separation, the detector has been used for determination of itopride hydrochloride in human serum. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of itopride hydrochloride in the range of 1.0 × 10−8 g mL−1 to 1.0 × 10−6 g mL−1 and the detection limit was 3 × 10−9 g mL−1 (S/N = 3). The as-prepared ECL detector displayed good sensitivity and stability.  相似文献   