首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A simultaneous distillation-extraction apparatus proposed by Godefroot has been used for the GC study of volatile components of cheese. 5–10 g of cheese provide a fraction that can be directly injected into a GC or a GC/MS. Two capillary columns (SE-30 and SP-1000) were evaluated, the second one being adequate for quantitative determinations. Camphor was used as internal standard. The coefficients of variation ranged from 1.4 to 11.8. The technique can be used as a fast method for the characterization of cheeses from their volatile component concentrations.  相似文献   

2.
Cistus ladanifer is a Mediterranean native plant from which valuable products, such as essential oil, are obtained. Manual harvesting of the plants in wild shrublands is usual during short periods of time. Their mechanised harvesting could increase the volume of harvested plants and prevent fires, further storage of the plants collected being necessary. The objective of this work is to study the influence of the storage period of mechanically harvested bales on the essential oil yield and qualitative composition. The harvesting trials were carried out with an adapted commercial harvester baler and the storage of the bales was performed indoors during 1–7 days, 15–30 days and 100–120 days. Afterwards, the bales were crushed (30 mm) and distilled in a 30 litre stainless steel still with saturated steam (0.5 bar). The essential oil components were identified by GC-MS and quantified by GC-FID. The storage of mechanically harvested Cistus ladanifer does not decrease the oil yield of steam distillation on a pilot scale. However, it leads to differences in the quantitative composition of the essential oils, decreasing the total monoterpene compounds content and increasing that of oxygenated sesquiterpenes, especially when the biomass is stored for 100–120 days, without affecting its qualitative composition.  相似文献   

3.
Zhang H  Shi Y  Wei S  Wang Y  Zhang H 《Talanta》2011,85(2):1081-1087
Ultrasonic nebulization extraction (UNE) coupled with headspace single-drop microextraction (HS-SDME) was developed. In the UNE process, the analytes were transferred from the aqueous phase to the gas phase. Then the analytes were transferred from the gas phase to the solvent phase by the carrier gas and extracted and enriched with suspended microdrop solvent. Finally, the microdrop solvent injected into GC-MS system. The parameters affecting extraction performance, such as type of suspended solvent, microdrop volume, flow rate of carrier gas, temperature of extraction vessel and extraction time were investigated and optimized. The proposed method can be applied for the extraction and enrichment of the volatile and semivolatile compounds simultaneously. The extraction efficiency of the proposed method was compared with that of ultrasonic extraction (UE) and UE-HS-SDME. Compared with UE-HS-SDME, the contents of constituents in the extract obtained by the proposed method were closer to those obtained by hydrodistillation (HD), which is a standard extraction method.  相似文献   

4.
ABSTRACT

The aim of this study was to provide the first from-start-to-end thin-layer chromatographic method of fingerprinting the Cistus incanus L. raw herbal material, with a purpose to further use it for rapid screening, authentication, and quality control of the traded C. incanus L. herbs. To this effect, 12 different C. incanus L. samples purchased as herbal teas from a local market were extracted by means of the accelerated solvent extraction (ASE) with chemometrically optimized solvent extraction mixture and temperature (methanol–water, 27:73, v/v; 130°C), to derive the polar fraction from the plant samples. Then, the extracts were developed in two thin-layer chromatographic systems, both using the commercially precoated silica gel 60 chromatographic plates, yet two different mobile phases (mobile phase 1, ethyl acetate–formic acid–acetic acid–water, 100:11:11:13, v/v/v/v, and mobile phase 2, ethyl acetate–dichloromethane–formic acid–acetic acid–water, 100:10:10:10:11, v/v/v/v/v). The chromatograms were densitometrically scanned in the reflectance mode at the wavelength λ?=?366?nm to obtain fingerprints of the extracts derived from individual C. incanus L. samples. Mobile phase 2 performed slightly better, because with its use, the maximum number of 11 peaks could be seen in the respective fingerprints, whereas with mobile phase 1, the maximum number of 10 peaks only. Then an antioxidant potential of the investigated herbal extracts was assessed, making use of mobile phase 2 and the 0.20% methanol solution of 2,2-diphenyl picrylhydrazyl as a visualizing reagent. The resulting chromatograms were densitometrically scanned in the extinction mode at the wavelength λ?=?550?nm to obtain biological fingerprints of the extracts. Finally, chromatographic and biological fingerprints underwent a semiquantitative evaluation in terms of the contents of the extracted polar fraction and an overall antioxidant potential of the individual plant species.  相似文献   

5.
Air in a room infested by Cimex lectularius L. (Hemiptera: Cimicidae) was sampled simultaneously by three different sampling devices including solid phase microextraction (SPME) fiber coatings, thin film microextraction (TFME) devices, and needle trap devices (NTDs) and then analyzed by gas chromatography–mass spectrometry (GC–MS). The main focus of this study was to fully characterize indoor air by identifying compounds extracted by three different microextraction formats and, therefore, perform both the device comparison and more complete characterization of C. lectularius pheromone. The NTD technique was capable of extracting both (E)-2-hexenal and (E)-2-octenal, which were previously identified as alarm pheromones of bedbugs, and superior NTD recoveries for these two components allowed reliable identification based on mass spectral library searching and linear temperature programmed retention index (LTPRI) technique. While the use of DVB/CAR/PDMS SPME fiber coatings provided complementary sample fingerprinting and profiling results, TFME sampling devices provided discriminative extraction coverage toward highly volatile analytes. In addition to two alarm pheromones, relative abundances of all other analytes were recorded for all three devices and aligned across all examined samples, namely, highly infested area, less infested area, and control samples which were characterized by different bedbug populations. The results presented in the current study illustrate comprehensive characterization of infested indoor air samples through the use of three different non-invasive SPME formats and identification of novel components comprising C. lectularius pheromone, therefore, promising future alternatives for use of potential synthetic pheromones for detection of infestations.  相似文献   

6.
P. Popp  A. Paschke 《Chromatographia》1997,46(7-8):419-424
Summary A new 80 μm Carboxen-polydimethylsiloxane (PDMS) fiber for solid phase microextraction (SPME) was tested for the enrichment of volatile organic compounds from water and air. Detection limits between 13 ng L−1 (CH2Cl2) and 0.1 ng L−1 (CHCl2Br and CHClBr2) for the combination: Carboxen-PDMS fiber and GC-ECD and between 35 ng L−1 and 45 ng L−1 (BTEX compounds) for the combination: Carboxen-PDMS and GC-FID using the headspace procedure were determined. Comparisons with the 100 μm PDMS fiber and further coatings show the advantages of the Carboxen-PDMS fiber with respect to extraction efficiency. Disadvantages of the new fiber compared with the 100 μm PDMS fiber are poorer repeatability and prolongation of equilibrium time. Distribution coefficients of the BTEX compounds between aqueous solution and SPME fiber coating were calculated and compared with the results of other researchers and with octanol-water partition coefficients.  相似文献   

7.
蛇油的挥发性成分分析和脱腥   总被引:1,自引:0,他引:1  
孙培冬  马樱 《分析试验室》2007,26(11):74-78
采用水蒸汽蒸馏、黏土吸附、乙醇-乙酸乙酯共沸的方法除去蛇油的腥味,运用顶空固相微萃取(SPME)-气相色谱(GC)-质谱(MS)联用技术分析脱腥前后蛇油中挥发性成分的变化,并运用GC-MS联用技术分析脱腥后的蛇油中的脂肪酸.结果表明水蒸汽蒸馏是效果最佳的脱腥方法,它可使蛇油挥发性成分的量降至脱腥前的38%,使腥味的主要成分减少60%~100%,同时较大程度地保留了多不饱和脂肪酸.  相似文献   

8.
Solid phase microextraction (SPME) was applied in the development of a protocol for the analysis of a number of target organic compounds in landfill site samples. The selected analytes, including aromatic hydrocarbons, chlorinated hydrocarbous, and unsaturated compounds, were absorbed directly from a headspace sample above a soil layer onto a fused silica fiber. Following exposure, the fiber was thermally desorbed in the injection port of the gas chromatograph and eluted compounds were detected using a mass selective detector. The stability and sensitivity of the extraction technique were examined at five temperatures (22–60°C) using a 100μm polydimethylsiloxane fiber. Calibrations, using soil samples spiked with selected solvents (0.5–30 μg/g), were linear; trichloroethene (r2 = 0.992) and benzene (r2 = 0.998). SPME was applied to the examination of a municipal landfill where 8 sites were sampled, at three depths, resulting in the detection of xylene (maximum 2.8 μg/g) and a number of other non-target organic contaminants.  相似文献   

9.
In this study, a simple and solvent-free method was developed for determination of the volatile compounds from fresh flowers of Syringa oblata using headspace solid-phase microextraction and gas chromatography-mass spectrometry. The SPME parameters were studied, the optimum conditions of a 65 μm polydimethylsiloxan/divinylbenezene (PDMS/DVB), extraction temperature of 25 °C and extraction time of 30 min were obtained and applied to extraction of the volatile compounds emitted from fresh flowers of S. oblata. The volatile compounds released from fresh flowers of S. oblata were separated and identified by GC-MS. Lilac aldehyde A, lilac aldehyde B, lilac aldehyde C, lilac aldehyde D, lilac alcohol A, lilac alcohol B, lilac alcohol C, lilac alcohol D, α-pinene, sabinene, β-pinene, myrcene, d-limonene, eucalyptol, cis-ocimene, benzaldehyde, terpinolene, linalool, benzene acetaldehyde, α-terpineol, p-methoxyanisole, p-anisaldehyde, (Z,E)-α-farnesene and (E,E)-α-farnesene were the most abundant volatiles released from fresh flowers of S. oblata var. alba. The relative contents of main volatile fragrance were found to be different in emissions from two varieties of S. oblata flowers (white or purple in color). The four isomers of lilac alcohol and four isomer lilac aldehyde were the characteristic components of the scent of fresh flowers of S. oblata. The main volatile fragrance from fresh flowers of S. oblata var. alba in different florescence ((A) flower buds; (B) at the early stage of flower blooming; (C) during the flower blooming; (D) at the end of flower blooming; (E) senescence) were studied in this paper. The results demonstrated that headspace SPME-GC-MS is a simple, rapid and solvent-free method suitable for analysis of volatile compounds emitted from fresh flowers of S. oblata in different florescence.  相似文献   

10.
Two different fibre coatings, for solid phase microextraction (SPME) sampling, poly(dimethylsiloxane) (PDMS) and poly(acrylate) (PA), were studied in order to test, for olive oil matrixes, two mathematical models that relate the directly proportional relationship between the amount of analyte absorbed by a SPME fibre and its initial concentration in the sample matrices. Although the PA fibre was able to absorb higher amounts of compounds from the olive oil sample, the equilibrium was reached later then with the PDMS fibre. In both cases, the amount of analyte present affected the time profile or the equilibrium time in two of the concentrations studied, 0.256 μL/kg, 2.56 μL/kg and for 2-ethylfuran, pentan-3-one, pent-1-en-3-one, hexanal, trans,trans-non-2,4-dienal and in the four concentrations studied, 0.256 μL/kg, 2.56 μL/kg, 6.25 μL/kg and 400 μL/kg, for 4-methyl-pent-3-en-2-one, 2-methylbutan-1-ol, methoxybenzene, hexan-1-ol, cis-hex-3-en-1-ol, trans-hex-2-en-1-ol, 2-ethyl-hexan-1-ol and trans,trans-dec-2,4-dienal. Comparing the mathematical models of both fibres, the PA-coated fibre showed direct proportionality between the initial concentration and amount extracted, that allows the possibility of relative quantification in a non-equilibrium state in non-aqueous media. The same was not observed for the PDMS fibre.  相似文献   

11.
A fast, sensitive and selective procedure employing a combination of microwave-assisted extraction (MAE) and solid phase extraction (SPE) was applied prior to liquid chromatographic identification and quantification of phenolic compounds in plant materials. MAE has been tested and optimized for the isolation of phenolic acids (gallic, protocatechuic, p-hydroxybenzoic, chlorogenic, vanilic, caffeic, syringic, p-coumaric, ferulic, sinapic, benzoic, m-coumaric, o-coumaric, rosmarinic, cinnamic acids) and 3,4-dihydroxybenzaldehyde, syringaldehyde, p-hydroxybenzaldehyde, and vanillin in various plants. The effects of experimental conditions on MAE efficiency, such as solvent composition, temperature, extraction time, have been studied. The extraction efficiencies were compared with those obtained by computer-controlled, two-step Soxhlet-like extractions. Plant extracts were purified and phenolic compounds were pre-concentrated using SPE on polymeric RP-105 SPE sorbent prior to HPLC analysis. Chromatographic separation was carried out on a Hypersil BDS C18 column using a mobile phase consisted of 0.3% (v/v) acetic acid in water (solvent A) and methanol (solvent B) at flow rate 0.6 ml min−1 and column temperature 30 °C with gradient elution.  相似文献   

12.
A simple and fast method based on solid-phase microextraction (SPME) followed by fast gas chromatography (Fast GC) has been developed for the analysis of volatile compounds in Asturian apple juices employed in the cider production. Three different fiber coatings have been checked (PDMS, PDMS-DVB and CAR-PDMS) and PDMS-DVB has been presented to be the most suitable one. Experimental design has been employed in the optimization of extraction factors and robustness assessment. The use of Fast GC allowed the separation of 14 compounds (esters, aldehydes and alcohols) in approximately 4 min, clearly reducing the analysis time when compared to conventional GC. Good linearity, recoveries and repeatability of the solid-phase microextraction were obtained with r(2) values, recoveries and relative standard deviations ranging from 0.9822 to 0.9998, 83.2 to 109.8% and 0.5 to 11.7%, respectively, using standard solution.  相似文献   

13.
茼蒿挥发性成分的固相微萃取气相色谱-质谱分析   总被引:6,自引:0,他引:6  
采用顶空固相微萃取技术富集茼蒿挥发性化合物,经气相色谱—质谱联用仪分析,共分离和鉴定了25个化合物;主要的化合物及相对含量为蒎烯38.6%、罗勒烯19.3%、2-己烯醛9.0%、1,6,10-十五碳三烯6.4%、乙酸冰片酯4.3%、大根香叶烯2.7%和金合欢烯1.1%等。  相似文献   

14.
The volatile composition of different apple varieties of Malus domestica Borkh. species from different geographic regions at Madeira Islands, namely Ponta do Pargo (PP), Porto Santo (PS), and Santo da Serra (SS) was established by headspace solid‐phase microextraction (HS‐SPME) procedure followed by GC‐MS (GC‐qMS) analysis. Significant parameters affecting sorption process such as fiber coating, extraction temperature, extraction time, sample amount, dilution factor, ionic strength, and desorption time, were optimized and discussed. The SPME fiber coated with 50/30 μm divinylbenzene/carboxen/PDMS (DVB/CAR/PDMS) afforded highest extraction efficiency of volatile compounds, providing the best sensitivity for the target volatiles, particularly when the samples were extracted at 50°C for 30 min with constant magnetic stirring. A qualitative and semi‐quantitative analysis between the investigated apple species has been established. It was possible to identify about 100 of volatile compounds among pulp (46, 45, and 39), peel (64, 60, and 64), and entire fruit (65, 43, and 50) in PP, PS, and SS apples, respectively. Ethyl esters, terpenes, and higher alcohols were found to be the most representative volatiles. α‐Farnesene, hexan‐1‐ol and hexyl 2‐methylbutyrate were the compounds found in the volatile profile of studied apples with the largest GC area, representing, on average, 24.71, 14.06, and 10.80% of the total volatile fraction from PP, PS, and SS apples. In PP entire apple, the most abundant compounds identified were α‐farnesene (30.49%), the unknown compound m/z (69, 101, 157) (21.82%) and hexyl acetate (6.57%). Regarding PS entire apple the major compounds were α‐farnesene (16.87%), estragole (15.43%), hexan‐1‐ol (10.94), and E‐2‐hexenal (10.67). α‐Farnesene (30.3%), hexan‐1‐ol (18.90%), 2‐methylbutanoic acid (4.7%), and pentan‐1‐ol (4.6%) were also found as SS entire apple volatiles present in a higher relative content. Principal component analysis (PCA) of the results clustered the apples into three groups according to geographic origin. Linear discriminant analysis (LDA) was performed in order to detect the volatile compounds able to differentiate the three kinds of apples investigated. The most important contributions to the differentiation of the PP, PS, and SS apples were ethyl hexanoate, hexyl 2‐methylbutyrate, E,E‐2,4‐heptadienal, p‐ethyl styrene, and E‐2‐hexenal.  相似文献   

15.
The complexity and matrix variability of biological samples requires an accurate evaluation of matrix effects. The dilution of the biological sample is the simplest way to reduce or avoid the matrix effect. In the present study, a set of volatile organic compounds with different volatilities was used to assess the effect of the dilution of blood samples on the extraction efficiency by headspace solid‐phase microextraction. It was found that there was a significant matrix effect but that this effect differs significantly depending on the volatility of the compound. A 1:2 (blood/water) dilution was enough to allow quantitative recoveries of those compounds with boiling points <100°C. For compounds with boiling points between 100 and 150°C, the matrix effect was stronger and a 1:5 dilution was required. The dilution of blood samples proved to be inefficient for quantitative recovery of compounds with boiling points >150°C. A 1:5 dilution of the sample allowed detection limits in the range of nanogram per liter to be obtained. This was sufficient to detect the main volatile compounds present in blood and contamination after exposure.  相似文献   

16.
《Analytical letters》2012,45(14):2223-2234
This study reports the application of a dispersive extraction method for the extraction and separation of phenolic acids from Salicornia Herbacea L. using silica-confined ionic liquids as the sorbent. A suitable sorbent for phenolic acid extraction and separation was first identified based on the adsorption behavior of phenolic acids on different silica-confined ionic liquids. The sample was then mixed with the optimized sorbent and solvent to achieve dispersive extraction. After transferring the supernatant to an empty cartridge, a solid phase extraction process was used to separate the three organic acids from other interferences. Through systematical optimization, the optimal conditions were obtained with high recovery rates of protocatechuic acid (98.1%), caffeic acid (89.4%), and ferulic acid (92.2%). Overall, the proposed method expected to have wide applicability.  相似文献   

17.
Various sampling techniques including flash evaporation (FE), headspace solid-phase microextraction (HS-SPME) and steam distillation (SD) were compared for the gas chromatography-mass spectrometry of volatile constituents present in Houttuynia cordata Thunb (HCT). 2-Undecanone (22.21%) and houttuynum (7.23%) were predominant components of HCT samples obtained by HS-SPME whereas those levels were 3.95 and 3.60% in the same samples by FE and 25.93 and 6.60% in those by SD, respectively. SPME with polydimethylsiloxane (PDMS) fibre was more selective and particularly efficient for the isolation of biologically active compounds and afforded a higher yield of total compounds than FE and SD. A total of 60 compounds were detected in SPME extracts. While in FE and SD extracts, the detected compounds were 41 and 51, respectively. The total amount of compounds isolated by SPME was much larger than that isolated by FE or SD. Some minor constituents were isolated by SPME, but not by SD and FE. This carries great significance because of the importance of the oil volatiles to clinical therapy. HS-SPME is a powerful tool for determining the volatile constitutes present in the TCMs.  相似文献   

18.
This study was designed to identify and quantify the carotenoids and phenolic compounds from annatto seeds using high performance liquid chromatography coupled to diode array and mass spectrometer detectors (HPLC-DAD-MS/MS). Furthermore, using response surface methodology, an optimized procedure for simultaneous extraction of these compounds was established. In addition to bixin, known to be the main carotenoid in annatto seeds, hypolaetin and a caffeoyl acid derivative were identified as the main phenolic compounds. The optimized procedure involved 15 extractions using acetone:methanol:water (50:40:10, v/v/v) as solvent, a solid-liquid ratio of 1:9 (m/v) and an extraction time of 5 min. Validation data indicated that the HPLC method proposed provided good linearity, sensitivity, procedure accuracy, system precision and suggested its suitability for the simultaneous analysis of phenolic compounds and carotenoids in annatto seeds.  相似文献   

19.
In this study, the usability of the plant thistle, Onopordum acanthium L., belonging to the family Asteraceae (Compositae), in liquid fuel production has been investigated. The experiments were performed in a fixed-bed Heinze pyrolysis reactor to investigate the effects of heating rate, pyrolysis temperature and sepiolite percentage on the pyrolysis product yields and chemical compositions. Experiments were carried out in a static atmosphere with a heating rate of 7 °C/min and 40 °C/min, pyrolysis temperature of 350, 400, 500, 550 and 700 °C and particle size of 0.6 < Dp < 0.85 mm. Catalyst experiments were conducted in a static atmosphere with a heating rate of 40 °C/min, pyrolysis temperature of 550 °C and particle size of 0.6 < Dp < 0.85 mm. Bio-oil yield increased from 18.5% to 27.3% with the presence of 10% of sepiolite catalyst at pyrolysis temperature of 550 °C, with a heating rate of 40 °C/min, and particle size of 0.6 < Dp < 0.85 mm. It means that the yield of bio-oil was increased at around 48.0% after the catalyst added. Chromatographic and spectroscopic studies on the bio-oil showed that the oil obtained from O. acanthium L. could be used as a renewable fuels and chemical feedstock.  相似文献   

20.
This paper describes a novel analytical method, flash gas chromatography (FGC), for the analysis of volatile compounds from Houttuynia cordata Thunb. This method does not demand time-consuming extraction process. The ground powder of the plant material can be directly applied for the analysis and only a few milligrams of sample are needed. The identification of the components was made by FGC-MS. The results between FGC and ordinary GC (using the extracted essential oil as sample) were compared and found that FGC offered a similar number and types of the components with GC. FGC is a novel and feasible method for the quality control of traditional Chinese medicines (TCMs).  相似文献   