首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and efficient solid-phase microextraction (SPME) method for the determination of seven pyrethroid insecticides including fenpropathrin, λ-cyhalothrin, deltamethrin, fenvalerate, permethrin, τ-fluvalinate and bifenthrin in cucumber and watermelon samples using high performance liquid chromatography combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection (SPME-HPLC-PIF-FD) was developed and validated. The optimum SPME conditions were used for the extraction of samples of both matrices (extraction time 30 min, stirring rate 1100 rpm, extraction temperature 65 °C, sample pH 3, soaking time 7 min, desorption time 5 min, ACN content 25%, desorption and soaking solvent was the mobile phase and in static mode). The method was validated in terms of limits of detection (LODs) and the limits of quantification (LOQs) in both IUPAC and EURACHEM criteria. LODs and LOQs were achieved in values lower than the maximum residue levels (MRLs) established in the Spanish regulations for all pesticides in this study (MRLs range between 0.01 and 0.1 mg kg−1 for all pyrethroid insecticides in both matrices). LOQs according to the second criterion were between 1.5 and 5 μg kg−1 for cucumber; and between 1.3 and 5 μg kg−1 for watermelon samples. Precision and recovery studies were evaluated at two concentration levels for each matrix. Good precision was obtained and relative standard deviation values were less than 10% in all cases. Recovery values were calculated at 0.05 and 0.5 mg kg−1 levels (n = 6) and they ranged between 93% and 108% for cucumber and between 91% and 110% for watermelon samples. Applicability of the method to pyrethroids in cucumber and watermelon of commercial samples was demonstrated.  相似文献   

2.
This study examines the application of coupled-column LC-photochemically induced fluorimetry-fluorescence detection (LC-LC-PIF-FD), demonstrating its potential for the quantitative and selective detection of six herbicides, including propanil and the phenylureas monuron, monolinuron, chlorotoluron, diuron and neburon in groundwater samples. An AQUASIL C18 50 x 4.6 mm(2) id column coupled to an AQUASIL C18 150 x 4.6 mm(2) id column for analyte clean-up and determination were used, respectively. A simple SPE with Cl8 cartridges was carried out, yielding average recoveries between 80 and 112% (n = 6) with RSDs between 0.5 and 9%. The LODs ranged from 0.0083 to 0.0833 microg/L in the groundwater samples.  相似文献   

3.
A solid-phase microextraction (SPME) method has been developed for the determination of six benzoylureas (diflubenzuron, triflumuron, hexaflumuron, teflubenzuron, lufenuron, and flufenoxuron) in natural orange juice based on the direct immersion mode of a 60 microm polydimethylsiloxane/divinylbenzene fiber. An orange juice was obtained from blended, homogenized, and diluted ecological natural orange juice samples. An aliquot of 3 mL of a spiked sample was extracted under optimum SPME conditions. The determination of benzoylureas was carried out using HPLC combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection. The limits of quantification obtained in matrix were within the range of 0.02 to 0.04 mg/kg and these limits are lower than the maximum residue levels established in Spanish regulations for all pesticides in this study. Recoveries in juice samples ranged between 85 and 110% and relative standard deviations between 1.8 and 7.4%.  相似文献   

4.
This study reports the first application of coupled-column liquid chromatography–photochemically induced fluorimetry–fluorescence detection (LC-LC-PIF-FD), demonstrating its potential for the quantitative and selective detection of seven pyrethroids in vegetable samples such as cucumber, green bean, tomato and aubergine. An internal surface reversed-phase (ISRP) column coupled to a C18 column for analyte clean-up and determination were used, respectively. In comparison with a C18 column, the ISRP substantially improved the separation between analytes and interferences from the vegetable matrix. The limits of detection ranged from 0.01 to 0.22 g kg–1 in the vegetable samples (equivalent to 0.01 and 0.13 g L–1 in the extract injected), and limits of determination ranged from 0.56 to 8.33 g kg–1 in the vegetable samples (equivalent to 0.34 and 5.00 g L–1 in the extract injected). Samples were extracted into dichloromethane to yield mean recoveries at two levels of concentration between 72.8 and 110.0% in all cases. Relative standard deviations were lower than 11%.  相似文献   

5.
Solid-phase microextraction (SPME) coupled to LC for the analysis of five diphenylether herbicides (aclonifen, bifenox, fluoroglycofen-ethyl, oxyfluorfen, and lactofen) is described. Various parameters of extraction of analytes onto the fiber (such as type of fiber, extraction time and temperature, pH, impact of salt and organic solute) and desorption from the fiber in the desorption chamber prior to separation (such as type and composition of desorption solvent, desorption mode, soaking time, and flush-out time) were studied and optimized. Four commercially available SPME fibers were studied. PDMS/divinylbenzene (PDMS/DVB, 60 microm) and carbowax/ templated resin (CW/TPR, 50 microm) fibers were selected due to better extraction efficiencies. Repeatability (RSD, < 7%), correlation coefficient (> 0.994), and detection limit (0.33-1.74 and 0.22-1.94 ng/mL, respectively, for PDMS/DVB and CW/TPR) were investigated. Relative recovery (81-104% for PDMS/DVB and 83-100% for CW/TPR fiber) values have also been calculated. The developed method was successfully applied to the analysis of river water and water collected from a vegetable garden.  相似文献   

6.
Solid-phase microextraction (SPME) is a rapid and simple analytical technique which uses coated fused-silica fibers to extract analytes from aqueous samples. This study develops a method of SPME analysis for seven pyrethroids, including fenpropathrin, lambda-cyhalothrin, deltamethrin, fenvalerate, permethrin, tau-fluvalinate and bifenthrin in groundwater samples using high performance liquid chromatography combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection (SPME-LC-PIF-FD). To perform the SPME, a 60 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used for the extraction of the pesticides from groundwater samples. The main factors affecting the SPME process, such as extraction time, stirring rate, extraction temperature, pH and the desorption process were studied. The use of photochemically induced fluorescence for detection improved sensitivity and selectivity. The limits of quantification (LOQs) obtained in the matrix, with respect to EURACHEM Guidance, varied between 0.03 and 0.075 microgL(-1). Relative recoveries ranged from 92 to 109% and relative standard deviations values ranged from 2 to 9%.  相似文献   

7.
Shiqian Gao 《Talanta》2010,82(4):1371-99
The determination of phenylurea and triazine herbicides in milk based on microwave assisted ionic liquid microextraction (MAILME) coupled with high-performance liquid chromatographic separation was described. The experimental parameters of the MAILE, including type and amount of ionic liquid, microwave extraction power, extraction time and salt concentration in sample, were evaluated by a univariate method and orthogonal screening. When 60 μL of [C6MIM][PF6] was used as extraction solvent the target compounds can be isolated from the 4 mL of milk. The MAILME is quick (7 min) and simple. The detection limits for isoproturon, monolinuron, linuron, propazine, prometryne, terbutryn and trietazine are 0.46, 0.78, 1.00, 1.21, 1.96, 0.84 and 1.28 μg L−1, respectively. The proposed method was applied to the analysis of milk samples and the recoveries of the analytes ranged from 88.4 to 117.9% and relative standard deviations were lower than7.43%.  相似文献   

8.
Tso-Ying Chou 《Talanta》2009,80(2):493-9119
Partitioned dispersive liquid-liquid microextraction (PDLLME), using THF as the dispersive solvent and dichloromethane as the extraction solvent, was utilized to isolate and concentrate phenylurea herbicides (PUHs) from aqueous samples. In PDLLME, a dispersive solvent should be able to partition in the organic extractant droplets to effectively extract the polar organic compounds from aqueous samples. The mixture of the water-immiscible extractant and the partitioned dispersive solvent was obtained by centrifugation, dried under low pressure, reconstituted in methanol-water mixture (1:1), and injected into a HPLC system for the determination of PUHs. The enrichment factors of the PUHs ranged from 68 to 126 under the optimal conditions. The linear range was 0.5-100 ng ml−1 for each analyte, the relative standard deviations of PUHs were in the range of 1.5-5.9% (n = 5), and the detection limits (signal-to-noise ratio of 3) ranged from 0.10 to 0.28 ng ml−1 for the herbicides. The range of intraday precision (n = 5) for PUHs at the levels of 0.5, 5, and 50 ng ml−1 were 3.0-5.9%, 1.8-3.3%, and 2.2-3.6%, respectively. The range of interday precision (n = 5) at 0.5, 5, and 50 ng ml−1 were 0.4-1.8%, 1.2-2.4%, and 0.9-2.3%, respectively. The recoveries of PUHs from three spiked river water samples, at a level of 10 ng ml−1, were 91.2-104.1%. Due to its rapidity, ease of operation, and high recovery, PDLLME can be utilized to isolate and concentrate organic environmental contaminants such as PUHs from aqueous samples.  相似文献   

9.
This work describes a new approach for the determination of trimethylamine (TMA) in water and air by liquid chromatography (LC). The assay is based on the employment of a solid-phase microextraction (SPME) fiber for sampling and for derivatization of the analyte with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC). The fiber, with a Carbowax-templated resin −50 μm coating, was first immersed into a solution of the reagent. Once loaded with the reagent, the fiber was immersed into the water samples or exposed to the air samples in order to extract and to derivatize the analyte. Finally, the fiber was placed into a HPLC-SPME interface to desorb and transfer the TMA-FMOC derivative to the LC equipment. A comparative study of the analytical characteristics of the procedure in water and air samples was carried out. Under optimized conditions, the proposed approach permits the quantification of TMA in solution within the 1.0-10.0 μg/ml interval and in air within the 25-200 mg/m3 interval. The limits of detection were 0.25 μg/ml and 12 mg/m3 (25 °C, 1.013 × 10−5 Pa) in water and air, respectively. The utility of the proposed method for determining TMA in different kind of samples is discussed.  相似文献   

10.
The coupled-column (LC-LC) system, consisting of a first column packed with internal surface reversed phase (ISRP) (50 x 4.6mm ID) and a Chrompack C18 (100 x 4.6 mm ID) as second column, allowed the simultaneous determination of five benzoylurea insecticides in dichloromethane (CH2Cl2) extracts of vegetable samples without any clean-up step. This system was combined with a photochemically induced fluorescence (PIF) post-column derivatization in order to provide strongly fluorescent photoproducts from the non-fluorescent benzoylureas. Limits of detection ranged from 0.21 to 0.98 microg L(-1) of pesticide (equivalent to 0.14-0.65 microg kg(-1) in vegetable samples) and limits of determination ranged from 4.0 to 10.0 microg L(-1) (equivalent to 2.7-6.7 microg kg(-1)). Linearity of the method was established between 2 and 1800 microg L(-1), depending upon the compound. Validation of the total method was performed by randomly analyzing recoveries of four vegetable samples (aubergine, cucumber, green bean, and tomato) spiked at two levels of concentration (10.0 and 33.3 microg kg(-1)). The combination of the LC-LC system with PIF detection provides a sensitive, selective, and rapid method for the determination of pesticides in vegetable samples at levels lower than the maximum residue levels (MRLs) established for these compounds by Spanish legislation.  相似文献   

11.
12.
Huang SD  Huang HI  Sung YH 《Talanta》2004,64(4):887-893
Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) for the determination of triazine is described. Carbowax/templated resin (CW/TPR, 50 μm), polydimethylsiloxane/divinylbenzene (PDMS/DVB, 60 μm), polydimethylsiloxane (PDMS, 100 μm), and polyacrylate (PA, 85 μm) fibers were evaluated for extraction of the triazines. CW/TPR and PDMS/DVB fibers were selected for further study. Several parameters of the extraction and desorption procedure were studied and optimized (such as types of fibers, desorption mode, desorption time, compositions of solvent for desorption, soaking periods and the flow rate during desorption period, extraction time, temperature, pH, and ionic strength of samples). Both CW/TPR and PDMS/DVB fibers are acceptable; a simple calibration-curve method based on simple aqueous standards can be used. The linearity of this method for analyzing standard solution has been investigated over the range 5-1000 ng mL−1 for both PDMS/DVB and CW/TPR fibers. All the correlation coefficients in the range 5-1000 ng mL−1 were better than 0.995 except Simazine and Atratone by CW/TPR fiber. The R.S.D.s range from 4.4% to 8.8 % (PDMS/DVB fiber) and from 2.4% to 7.2% (CW/TPR fiber). Method-detection limits (MDL) are in the range 1.2-2.6 and 2.8-3.4 ng mL−1 for the two fibers. These methods were applied to the determination of trazines in environmental water samples (lake water).  相似文献   

13.
Summary The analysis of several phenylurea herbicides in different waters is described using an immunoaffinity column clean-up and determination by high performance liquid chromatography. The pesticides were selectively retained on a solid phase extraction column containing antibodies to chlortoluron and to isoproturon immobilised onto silica. Selected phenylureas were eluted using a simple phosphate buffered saline/ethanol mixture at low pH. The immunoaffinity approach gave extracts free of interfering substances and allowed detection limits comparable to those required for pesticides in water in the European Community. The proposed method was successfully applied to the determination of chlortoluron, isoproturon, linuron and chlorbromuron in tap and river water. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996  相似文献   

14.
Solid-phase microextraction coupled with high-performance liquid chromatography was successfully applied to the analysis of nine phenylurea herbicides (metoxuron, monuron, chlorotoluron, isoproturon, monolinuron, metobromuron, buturon, linuron, and chlorbromuron). Polydimethylsiloxane-divinylbenzene (PDMS-DVB, 60 microm) and Carbowax-templated resin (CW-TPR, 50 microm) fibers were selected from four commercial fibers for further study because of their better extraction efficiencies. The parameters of the desorption procedure were studied and optimized. The effects of the properties of analytes and fiber coatings, carryover, duration and temperature of absorption, pH, organic solvent and ionic strength of samples were also investigated. External calibration with an aqueous standard can be used for the analysis of environmental samples (lake water) using either PDMS-DVB or CW-TPR fibers. Good precisions (1.0-5.9%) are achieved for this method, and the detection limits are at the level of 0.5-5.1 ng/ml.  相似文献   

15.
Coquet  A.  Haerdi  W.  Degli Agosti  R.  Veuthey  J. -L. 《Chromatographia》1994,38(1-2):12-16
Summary A method for the determination of reducing sugars such as fructose and glucose and nonreducing sugar such as sucrose by high performance liquid chromatography followed by an acidic hydrolysis and a derivatization with benzamidine has been developed. After separation of sugars on a gel column packed with a polymer-based cation exchange material (Sugar-Pak I, Waters-Millipore), the sucrose is first hydrolysed in a solid phase reactor to convert it into reducing subunits. A post-column fluorigenic reaction with benzamidine under alkaline condition allows the selective determination of both natural and converted reducing carbohydrates.This procedure has proven to be selective (fluorigenic detection) and highly sensitive (allowing detection as little as picomoles amounts), reproducible and linear over a broad range of concentrations: 5×10–4 to 1.0×10–2 M.The applicability of this method to natural matrices such as plant extracts and beverages is also described. The sugar content of a barley extract has been determined and compared with a specific enzymatic test. The determined sugar content of natural and commercial lemon juices as well as of Cola beverages has been compared with those found by the conventional LC refractive index analytical procedure. In all cases, the results were comparable and were within the experimental errors of the methods.  相似文献   

16.
Summary Eight triazine herbicides, prometon, propazine, atrazine, simazine, prometryn, ametryn, metribuzin, and cyanazine, have been extracted from human whole blood and urine samples by headspace solid-phase microextraction (SPME) with a polydimethylsiloxane-coated fiber and quantified by capillary gas chromatography with nitrogen-phosphorus detection. Extraction efficiencies for all compounds were 0.21–0.99% for whole blood, except for cyanazine (0.06%). For urine, the extraction efficiencies for prometon, propazine, atrazine, prometryn and ametryn were 13.6–38.1%, and those of simazine, metribuzin and cyanazine were 1.35–8.73%. The regression equations for the compounds extracted from whole blood were linear within the concentration ranged 0.01–1 μg (0.5 mL)−1 for prometon, propazine, atrazine, prometryn, and ametryn, and 0.02–1 μg (0.5 mL)−1 for simazine, metribuzin, and cyanazine. For urine, regression equations for all compounds were linear within the concentration range 0.005–0.25 μg mL−1. Compound detection limits were 2.8–9.0 ng (0.5 mL)−1 and 0.4–2.0 ng mL−1 for whole blood and urine, respectively. The coefficients of within-day and day-to-day variation were satisfactory for all the compounds, and not greater than 10.3 and 14.2%, respectively. Data obtained from determination of atrazine in rat whole blood after oral administration of the compound are also presented.  相似文献   

17.
A method based on direct immersion solid‐phase microextraction (DI‐SPME) coupled with high performance liquid chromatography combined with post‐column photochemically induced fluorimetry derivatization and fluorescence detection (HPLC‐PIF‐FD) was developed to extract three pyrethroid insecticides, i.e. cyfluthrin, cypermethrin, and flumethrin from water samples. A sol‐gel based coating fiber using 3‐(trimethoxysilyl propyl) amine as precursor was prepared and used for the extraction of the pyrethroids from groundwater samples. A post‐column photochemical reactor was designed and constructed for the derivatization of these environmentally important pollutants to increase their fluorescence sensitivity and determination in HPLC. The parameters affecting extraction process (extraction time and temperature, pH, salt addition, and co‐solvent) and desorption step (solvent, desorption time, and temperature) of the analytes from the sol‐gel‐based fiber, along with photochemical reaction conditions were investigated. The developed method proved to be relatively rapid, simple, and easy and offers high sensitivity and reproducibility. Linear dynamic ranges (LDR) for these insecticides were ranged between 0.25 to 50 μg/L. The regression coefficients were satisfactory (R2 > 0.984) for these pyrethroids. The limits of detection and limits of quantification varied between 0.09 and 0.35 μg/L and 0.25 and 1.00 μg/L, respectively. Relative standard deviation RSDs values varied between 4.41% and 6.20%. Relative recoveries obtained from analysis of Jajroud river water sample ranged between 94% and 104%.  相似文献   

18.
A rapid multiresidue method has been developed for the analysis of seven phenylurea herbicides in the presence of two s-triazines in environmental waters. A simple end-column electrochemical detector was used in combination with a commercially-available capillary electrophoresis instrument with UV detection. The determination of phenylurea pesticides using micellar electrokinetic capillary chromatography with electrochemical detection represents the first such determination that has been reported. In both detection systems, linear ranges were obtained for the seven phenylurea herbicides at concentrations lower than 2.0×10–5 mol l–1, in 0.020 mol l–1 phosphoric acid at pH 7.0 and containing 0.020 mol l–1 of sodium dodecylsulfate, in order to obtain selectivity in the additional separation by a micellar distribution process. Under these conditions a detection limit lower than 5.0×10–6 mol l–1 (0.25 pmol of pesticide) was achieved for most of them. The pesticides were resolved in less than 30 min.  相似文献   

19.
The use of a different optimization procedure that involves Experimental Design (ED) and Artificial Neural Networks (ANN) for the off-line coupling solid-phase microextraction-micellar electokinetic chomatography (SPME-MEKC) is presented. This combination of ED and ANN, mathematical tools not previously used in SPME-MEKC optimization, allowed us to obtain good extraction efficiencies in the SPME procedure for the determination of a group of eleven triazine herbicides in groundwater samples. Both extraction and desorption steps were carried out by solution stirring at 900 rpm. Optimal conditions for the off-line SPME procedure were: extraction with a poly(dimethylsiloxane)/divinylbenzene SPME fiber for 120 min, 10% (w/v) NaCl, desorption time 40 min, and 70% (v/v) of methanol/buffer as desorption mixture. Detection limits lay between 0.80 microg L(-1) and 4.89 microg L(-1). Finally, the optimized method was applied to the determination of these compounds in spiked and non-spiked groundwater samples using a previously optimized MEKC separation.  相似文献   

20.
A sensitive, selective, and reproducible in-tube polypyrrole-coated capillary (PPY) solid-phase microextraction and liquid chromatographic method for fluoxetine and norfluoxetine enantiomers analysis in plasma samples has been developed, validated, and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. Separation of the analytes was achieved with a Chiralcel OD-R column and a mobile phase consisting of potassium hexafluorophosphate 7.5 mM and sodium phosphate 0.25 M solution, pH 3.0, and acetonitrile (75:25, v/v) in the isocratic mode, at a flow rate of 1.0 mL/min. Detection was carried out by fluorescence absorbance at Ex/Em 230/290 nm. The multifunctional porous surface structure of the PPY-coated film provided high precision and accuracy for enantiomers. Compared with other commercial capillaries, PPY-coated capillary showed better extraction efficiency for all the analytes. The quantification limits of the proposed method were 10 ng/mL for R- and S-fluoxetine, and 15 ng/mL for R- and S-norfluoxetine, with a coefficient of variation lower than 13%. The response of the method for enantiomers is linear over a dynamic range, from the limit of quantification to 700 ng/mL, with correlation coefficients higher than 0.9940. The in-tube SPME/LC method can therefore be successfully used to analyze plasma samples from ageing patients undergoing therapy with fluoxetine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号