首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Jin J  Li Y  Zhang Z  Su F  Qi P  Lu X  Chen J 《Journal of chromatography. A》2011,1218(51):9149-9154
A new method for the selective cleanup of complex matrices and simultaneous separation of benzo[a]pyrene (BaP) was developed in this study. This method was based on solid-phase extraction (SPE) using magnesium oxide microspheres as sorbents, and it eliminated interferences from various impurities, such as lipids, sulphur, pigments, halobenzenes, polychlorodibenzo-p-dioxins and polychlorodibenzofurans. Several parameters, including the volume of rinsing and eluting solvents, the type of loading solvents and SPE sorbents, were optimized systematically. The capability for impurity removal was verified by gel permeation chromatography, gas chromatography, and liquid chromatography. Compared to commercial sorbents (silica gel, florisil and alumina), MgO microspheres exhibited excellent performance in the selective isolation of BaP and removal of impurities. The proposed method was applied to detect BaP in complex samples (sediments, soils, fish, and porcine liver). The limit of quantification (LOQ) was 1.04 ngL(-1), and the resulting regression coefficient (r(2)) was greater than 0.999 over a broad concentration range (9.5-7600 ngL(-1)). In contrast to traditional methods, the proposed method can give rise to higher recovery (85.1-100.8%) and better selectivity with simpler operation and less consumption of organic solvents (20-40 mL).  相似文献   

2.
Enrichment of benzo[a]pyrene in vegetable oils and determination by HPLC-FL   总被引:7,自引:0,他引:7  
We have developed a simple method for the determination of the carcinogen Benzo[a]pyrene (BP) in vegetable oils. The method consists of extraction of the vegetable oil in acetonitrile, concentration to dryness in rotary evaporator and redissolution of the residue in hexane. The purification of the hexane extract was on Sep-Pack Silica Plus cartridges, and the determination of the BP in the isolated extract was by HPLC-FL. Detection and quantification limits were 0.23 and 0.32 μg kg−1 of olive oil, respectively. Recovery (>93%) and RSD (<4%) were satisfactory. When applied to 18 oil samples, BP levels varied from not detected to 1.99 μg kg−1.  相似文献   

3.
Magnesium oxide microspheres were developed as a novel SPE sorbent for the determination of benzo[a]pyrene (BaP), one of the most potent carcinogenic agents, in environmental water samples. The parameters controlling the extraction efficiency, such as elution volume, flow rate, pH values, and breakthrough volume, were investigated in detail. Considering the facile preparation and satisfying recovery, a corresponding analytical method has been developed to determine the concentration of BaP in real tap water, river water, and seawater. The recoveries for the spiked BaP were excellent (94–101%).  相似文献   

4.
For the analysis of edible oils, saponification is well known as a useful method for eliminating oil matrices. The conventional approach is conducted with alcoholic alkali; it consumes a large volume of organic solvents and impedes the retrieval of analytes by microextraction. In this study, a low‐organic‐solvent‐consuming method has been developed for the analysis of benzo[a]pyrene in edible oils by high‐performance liquid chromatography with fluorescence detection. Sample treatment involves aqueous alkaline saponification, assisted by a phase‐transfer catalyst, and selective in situ extraction of the analyte with a supramolecular solvent. Comparison of the chromatograms of the oil extracts obtained by different microextraction methods showed that the supramolecular solvent has a better clean‐up effect for the unsaponifiable matter from oil matrices. The method offered excellent linearity over a range of 0.03– 5.0 ng mL−1 (r > 0.999). Recovery rates varied from 94 to 102% (RSDs <5.0%). The detection limit and quantification limit were 0.06 and 0.19 μg kg−1, respectively. The proposed method was applied for the analysis of 52 edible oils collected online in China; the analyte contents of 23 tested oil samples exceeded the maximum limit of 2 μg kg−1 for benzo[a]pyrene set by the Commission Regulation of the European Union.  相似文献   

5.
Länge K  Griffin G  Vo-Dinh T  Gauglitz G 《Talanta》2002,56(6):1153-1161
Antibodies of a polyclonal antiserum against benzo[a]pyrene were characterized by determining thermodynamic and kinetic constants of the antigen–antibody reaction. Label-free binding assays with optical detection based on reflectometric interference spectroscopy were performed to determine these constants. Different evaluation methods for kinetic measurements were compared. Also, cross-reactivity against two other polycyclic aromatic hydrocarbons, chrysene and pyrene, was checked. The affinity constant between the antibodies and benzo[a]pyrene in homogeneous phase was determined to be K=(5.3±0.3)×107 M−1 which was in the middle of the usual range of antibody affinities. The association rate constant for the reaction at the surface was determined to be (3.8±0.9)×105 M−1 s−1, the dissociation rate constant as (9.7±0.5)×10−3 s−1. Different evaluation methods applied to the kinetic measurements led to the same results. This antiserum would be suitable for the selective determination of benzo[a]pyrene in concentrated samples.  相似文献   

6.
Very simple and highly sensitive methods are presented for the determination of benzo[a]pyrene, one of the most carcinogenic polycyclic aromatic hydrocarbons (PAHs). The approaches are based on solid-phase extraction of the analyte on a nylon membrane via a syringe procedure, and its fluorescent or phosphorescent determination on the solid surface. While the native fluorescence of benzo[a]pyrene retained on a nylon surface is measured directly, room-temperature phosphorescence is induced by spotting a few microlitres of thallium(I) nitrate solution on the surface (heavy-atom effect). An enhancement of the phosphorescence signal was corroborated when the measurements were carried under a nitrogen atmosphere. The analytical figures of merit obtained under the best experimental conditions demonstrate the capability of detecting benzo[a]pyrene at a sub-parts-per-trillion (sub-ng L−1) level. The potential interference from other common PAHs and also from different metal ions was studied. The feasibility of determining benzo[a]pyrene in real samples was successfully evaluated through the analysis of spiked tap, underground and mineral water samples of different origins. Recoveries obtained from spiked river waters were successfully compared with those provided by a reference method, through rigorous statistical analysis.  相似文献   

7.
New solid-matrix phosphorescence (SMP) methods for (±)-anti-DB[a,l]PDE-DNA adducts and B[e]P were developed. The methods can be used to detect and characterize (±)-anti-DB[a,l]PDE-DNA adducts and B[e]P by employing SMP spectra, intensities, and lifetimes acquired with the heavy-atom salt, TlNO3, on Whatman 1PS paper. With the SMP data, a number of photophysical parameters were calculated such as biexponential SMP decay curves, pre-exponential factors, and fractional contribution to SMP decay curves. The SMP results were compared with earlier SMP data for (±)-anti-BPDE-DNA adducts and tetrol I-1. The SMP results show that small molecular-weight compounds like B[e]P can be readily detected and characterized by SMP. For example, the limit of detection for B[e]P was 0.60 pmol. Comparison of the SMP properties of the (±)-anti-DB[a,l]PDE-DNA adducts with earlier SMP data for the (±)-anti-BPDE-DNA adducts showed major differences in the SMP spectra, intensities, and lifetimes. The methods developed are important for the comparison of the SMP properties of different diol epoxides of PAH bonded to DNA.  相似文献   

8.
Al-Haddad A 《Talanta》2003,59(4):845-848
A back-flushing procedure using porous graphitic carbon (PGC) HPLC columns has been used successfully for the cleanup of soil samples for the determination of benzo[a]pyrene in ppb levels by an ODS-fluorescence HPLC column. The procedure was tested on nine random soil samples taken from an industrial area of the Kingdom of Bahrain. The mean percent recovery from the PGC column was 96% and the average coefficient of variation for the whole method was 5.2%.  相似文献   

9.
A quantitative immunochemical rapid test for sensitive determination of benzo[a]pyrene (BAP) as a model analyte was developed making use of a handheld reader for results evaluation. The covalent immobilization of antibodies to different Sepharose gels, i.e., CNBr-activated Sepharose 4B and CNBr-activated Sepharose 4 Fast Flow was compared with adsorption to a polyethylene support. The lowest limits of detection (LOD) were 4 ng L−1 and 40 ng L−1, respectively, using optimized assay conditions. The developed test was applied to food supplements (garlic, black radish and maca), including a pretreatment procedure. LOD of 9 ng kg−1 and linear range of 13-80 ng kg−1 were obtained. Results of BAP determination in naturally contaminated samples were confirmed by high-performance liquid chromatography coupled to fluorescence detection and a good correlation was achieved. We suggest that the developed test format can be used to quantitative detection of the low molecular weight analytes, such as mycotoxins, pesticides, other pollutants in food and environmental samples.  相似文献   

10.
11.
Plant phytochemicals, such as flavonoids are in use for the development of optical biosensor. Benzo[a]pyrene (B[a]P), is a pervasive environmental and dietary carcinogen. A fluorescent assay is developed using plant isolated flavonoid for the detection of B[a]P. High content saponins are excluded from the flavonoid-containing methanolic extract of Corchorus depressus by implying reduction of silver ions by saponins resulting in formation of silver nanoparticles. Isolated plant flavonoids are used to develop a spectrofluorometric assay for the detection of B[a]P. Decrease in the flavonoid fluorescence intensity by B[a]P is found to be based on both static and dynamic quenching. Specificity of the assay for B[a]P was tested for other carcinogens belonging to different classes of compounds. Flavonoids-mediated sensing can be implied for the development of new generation of nanoparticle-based biosensors that can be more sensitive and less susceptible to external factors, such as temperature and humidity.  相似文献   

12.
Improved technologies for the detection of polycyclic aromatic hydrocarbon adducts are required for human biomonitoring. Therefore, a coupled-column high-performance liquid chromatographic method, with system-integrated sample processing, has been developed and its applicability for determination of tetrahydrotetrols of polycyclic aromatic hydrocarbons in acid hydrolysates of human hemoglobin has been investigated. A novel column-switching technique applying ‘thermotransfer’ is used to separate tetrahydrotetrols of benzo[a]pyrene and benz[a]anthracene more efficiently. Derivatives of polycyclic aromatic hydrocarbons from blood hydrolysates are concentrated on a pre-column and then transferred to the analytical column by applying an electrical current to heat the solvent eluting the pre-column. This method allows for rapid and quantitative transfer of the analytes from the pre-column to the analytical column, after HPLC-integrated sample processing.  相似文献   

13.
Determination of benzo[a]pyrene (BaP) in cigarette smoke can be very important for the tobacco quality control and the assessment of its harm to human health. In this study, mid-infrared spectroscopy (MIR) coupled to chemometric algorithm (DPSO-WPT-PLS), which was based on the wavelet packet transform (WPT), discrete particle swarm optimization algorithm (DPSO) and partial least squares regression (PLS), was used to quantify harmful ingredient benzo[a]pyrene in the cigarette mainstream smoke with promising result. Furthermore, the proposed method provided better performance compared to several other chemometric models, i.e., PLS, radial basis function-based PLS (RBF-PLS), PLS with stepwise regression variable selection (Stepwise-PLS) as well as WPT-PLS with informative wavelet coefficients selected by correlation coefficient test (rtest-WPT-PLS). It can be expected that the proposed strategy could become a new effective, rapid quantitative analysis technique in analyzing the harmful ingredient BaP in cigarette mainstream smoke.  相似文献   

14.
The metabolites of the environmental pollutant, benzo[a]pyrene (BaP) are carcinogenic and mutagenic agents. Thus, the determination of additional products (adducts) of the interaction between DNA and BaP, attracts great interest in cancer research.

In this study, the determination of interaction between BaP and calf thymus double-stranded DNA (dsDNA) was performed by using differential pulse voltammetry (DPV) and constant current chronopotentiometric stripping analysis (PSA) in connection with carbon paste electrode (CPE) or glassy carbon electrode (GCE). As a result of interaction of BaP with dsDNA, the signal obtained from the oxidation of guanine decreased and a new adduct signal at a more positive potential appeared. This new peak is attributed to the formation of an adduct from the interaction of guanine with BaP. The chemically prepared anti-7,8,9,10-tetrahydrobenzo[a]pyrene-7,8-diol-9,10-epoxide (BPDE) adduct by using iodine oxidation was analyzed and the electrochemical signal of the adduct was observed. When the dsDNA modified GCE was immersed into various concentrations of BaP solution, the oxidation peak of guanine decreased and the adduct peak increased with the increasing BaP concentration. The partition coefficient was also obtained from the peak of BaP with dsDNA. The results revealed that the formation of adducts could be determined by using electrochemical DNA biosensors, which are fast, simple and cost-effective devices. Furthermore, this study promises that the analysis of other important adducts would benefit from the introduction of electrochemical methods.  相似文献   


15.
Benzo[a]pyrene diol epoxide (BPDE) was reacted in vitro with (2'-deoxy)nucleotides and with calf thymus DNA. The modified DNA was enzymatically hydrolyzed to the 5'-monophosphate nucleotides using deoxyribonuclease I (DNA-ase I), nuclease P1 and snake venom phosphodiesterase (SVP). Most of the unmodified nucleotides were removed using solid phase extraction (SPE) in a polystyrene divinylbenzene copolymer. Three adducts could be detected and identified using capillary zone electrophoresis(negative)-ion electrospray ionization-mass spectrometry (CZE-(-)-ESI-MS) in conjunction with sample stacking. This way, not only a BPDE-dGMP adduct [(M-H)(-) at m/z 648], a well-known nucleotide adduct, could be retrieved, but also a BPDE-dAMP [(M-H)(-) at m/z 632] and a BPDE-dCMP adduct [(M-H)(-) at m/z 608] could be detected for the first time. The presence of the prominent ion at m/z 195 (the deoxyribose-phosphate ion) in the three low-energy collision-activated decomposition (CAD) spectra indicated that the adducts were formed through base-alkylation. CZE-positive ion ESI-MS/MS experiments were performed to obtain further information on base-alkylation. The absence of the loss of NH(3) from the nucleobase in each CAD spectrum points to an alkylated exocyclic NH(2) position of the nucleobase. So, the three adducts could be identified as BPDE-N(2)-dGMP, BPDE-N(6)-dAMP and BPDE-N(4)-dCMP using CZE-ESI-MS and CZE-ESI-MS/MS.  相似文献   

16.
Solid‐phase extraction based on humic acid bonded silica followed by gas chromatography with electron capture detection was developed to determine fipronil and its metabolites in edible oil. To achieve the best extraction performance, we systematically investigated a series of solid‐phase extraction parameters. Under the optimized conditions, the method was validated according to linearity, recovery, and precision. Good linearities were obtained with R2 more than 0.9996 for all analytes. The limits of detection were between 0.3 and 0.5 ng/g, and the recoveries ranged from 83.1 to 104.0% at three spiked concentrations with intra‐ and interday relative standard deviation values less than 8.7%. Finally, the proposed method was applied to determine fipronil and its metabolites in 11 edible oil samples taken from Wuhan markets. Fipronil was detectable in four samples with concentrations ranging from 3.0 to 5.2 ng/g. In China, the maximum residue limits of fipronil in some vegetables and maize are 20 and 100 ng/g (GB/T 2763‐2014), respectively. The residues of fipronil and its metabolites in commercial edible oils might exhibit some potential threat to human health as a result of high consumption of edible oil as part of daily intake.  相似文献   

17.
18.
A green, convenient, high yielding and one-pot procedure for the synthesis of novel spiro[benzo[a]pyrano[2,3-c]phenazine] derivatives by domino multi-component condensation reaction between 2-hydroxynaphthalene-1,4-dione, benzene-1,2-diamines, ninhydrine, and malononitrile in the presence of a catalytic amount of 1,3-dimethyl-7H-purine-2,6-dione (theophylline) as an expedient, eco-friendly and reusable solid base catalyst under thermal, microwave irradiation and solvent-free conditions. This procedure has also been applied successfully for the synthesis of benzo[a]pyrano[2,3-c]phenazines.  相似文献   

19.
建立了一种快速、新颖的高效液相色谱荧光检测法测定天然生育酚中痕量苯并[a]芘.天然生育酚样品经中性氧化铝柱色谱富集和净化后在 XDB-C,18反相柱上,采用水-乙腈(体积比20比80)为流动相进行分离,采用荧光检测器进行检测,其激发波长为 260 nm,发射波长为 408 nm.苯并[a]芘的定量下限为 0.50 ng·g-1.加标回收率大于 77.9%.分析了 3 个不同试样,测定结果的相对标准偏差在 3.0%~10.6%之间.  相似文献   

20.
In this work, using benzo(a)pyrene (BaP) as marker, the analytical merits of on-line flow-injection cloud-point extraction (FI CPE), including preconcentration factor, extraction efficiency, sample throughput, and analysis time were evaluated by use of peroxyoxalate chemiluminescence (CL) detection. Moreover, by detailed discussion of several preconcentration conditions for traditional and on-line FI CPE the advantages of on-line FI CPE became conspicuously apparent. When coupled with separation techniques such as high-performance liquid chromatography (HPLC) or capillary electrophoresis (CE), on-line FI CPE–CL has much potential for analysis of low concentrations of polycyclic aromatic hydrocarbons (PAH) in environmental samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号