首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
Gynostemma pentaphyllum (Thunb.) Makino, a traditional Chinese herb possessing antitumor and antioxidant activities, has been shown to contain several functional components like saponins and flavonoids. However, their identities remain uncertain. The objectives of this study were to develop an appropriate extraction, purification and HPLC-MS method to determine saponins and flavonoids in G. pentaphyllum. Both flavonoids and saponins were extracted with methanol, followed by purification with a C18 cartridge to elute the former with 50% methanol and the latter with 100% methanol. A total of 34 saponins were separated within 40 min by a Gemini C18 column and a gradient mobile phase of acetonitrile and 0.1% formic acid in water, in which 18 saponins were identified by LC-MS with ESI mode and Q-TOF (LC/MS/MS). Similarly, a total of eight flavonoids were separated within 45 min by the same column and a gradient solvent system of methanol and 0.1% formic acid in water, with identification being carried out by a post-column derivatization method and LC-MS with ESI mode. The amounts of flavonoids in G. pentaphyllum ranged from 170.7 to 2416.5 μg g−1, whereas saponins were from 491.0 to 89,888.9 μg g−1.  相似文献   

2.
A rapid and sensitive LC?CMS?CMS method for the simultaneous determination of escin Ia and isoescin Ia in rat plasma, urine, feces and bile samples was developed and validated. Analytes and telmisartan [internal standard (IS)] were extracted by solid-phase extraction on C18 cartridges. Components in the extract were separated on an HC-C18 column (5 ??m, 150 × 4.6 mm i.d.) using 10 mM ammonium acetate?Cmethanol?Cacetonitrile (40:30:30, v/v/v) as the mobile phase. The method demonstrated good linearity from 5 ng mL?1 (LLOQ) to 1,500 ng mL?1 for both escin Ia and isoescin Ia. Intra- and inter-day precision measured as RSD was within ±15%. Recoveries and matrix effects of both escin Ia and isoescin Ia were satisfactory in all four matrices examined. The method was successfully applied to a pharmacokinetic study in Wistar rats after a single intravenous administration of escin Ia at the dose of 1.0 mg kg?1.  相似文献   

3.
Sereshti H  Khojeh V  Samadi S 《Talanta》2011,83(3):885-890
In this study, dispersive liquid-liquid microextraction (DLLME) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed for simultaneous preconcentration and trace determination of chromium, copper, nickel and zinc in water samples. Sodium diethyldithiocarbamate (Na-DDTC), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters of DLLME such as volume of extraction and disperser solvents, pH, concentration of salt and concentration of the chelating agent were studied by a (2f−1) fractional factorial design to identify the most important parameters and their interactions. The results showed that concentration of salt and volume of disperser solvent had no effect on the extraction efficiency. In the next step, central composite design was used to obtain optimum levels of effective parameters. The optimal conditions were: volume of extraction solvent, 113 μL; concentration of the chelating agent, 540 mg L−1; and pH, 6.70. The linear dynamic range for Cu, Ni and Zn was 1-1000 μg L−1 and for Cr was 1-750 μg L−1. The correlation coefficient (R2) was higher than 0.993. The limits of detection were 0.23-0.55 μg L−1. The relative standard deviations (RSDs, C = 200 μg L−1, n = 7) were in the range of 2.1-3.8%. The method was successfully applied to determination of Cr, Cu, Ni and Zn in the real water samples and satisfactory relative recoveries (90-99%) were achieved.  相似文献   

4.
Jing-Shan Chiang 《Talanta》2007,71(2):882-886
Dynamic hollow fiber liquid-phase microextraction (HF-LPME) coupled with gas chromatography with flame ionization detection (GC-FID) and GC-electron capture detecion (GC-ECD) was used for quantification of toxic haloethers in lake water. The analytes were extracted from 5 ml of aqueous sample using 4 μl of organic solvent through a porous polypropylene hollow fiber. The effects on extraction performance of solvent selection, agitation rate, extraction time, extraction temperature, concentration of salt added and volumes of solvent for extraction and injection were optimized. The proposed method provided a good average enrichment factor of up to 231-fold, reasonable reproducibility ranging from 9 to 12% (n = 3), and good linearity (R2 ≧ 0.9973) for spiked water samples. Method detection limits (MDLs) ranged from 0.55 to 4.30 μg/l for FID and 0.11-0.34 μg/l for ECD (n = 7).  相似文献   

5.
Homogeneous liquid-liquid extraction method was studied based on a phase separation phenomenon in a ternary solvent system. According to this procedure, mononitrotoloenes were extracted by single-phase extraction in a water/methanol/chloroform, homogeneous ternary solvent system. Methanol and chloroform were used as consolute and extraction solvents, respectively. The homogeneous solution was broken by the addition of salt and a cloudy solution was formed. After centrifugation, the fine droplets of the extraction solvent were sedimented in the bottom of the conical test tube. Analysis of the extracts was carried out by gas chromatography. The optimization procedure was performed using Box-Behnken design. The variables involved were: sample and extraction solvent volumes, consolute solvent volume and phase separator reagent concentration. Optimum results were obtained under the following conditions: sample volume of 5 mL, extraction solvent volume of 55 μL, consolute solvent volume of 1 mL and phase separator reagent concentration; 5% (w/v). Under these conditions, the enrichment factors of 354, 311 and 300, dynamic linear ranges of 0.5-500, 1-500 and 1-500 μg L−1, and limit of detections (LODs) of 0.09, 0.09 and 0.1 μg L−1 were obtained for o-nitrotoluene, m-nitrotoluene and p-nitrotoluene, respectively. Finally, the method was successfully applied to the extraction and determination of MNTs in the waste water samples in the range of micrograms per liter with R.S.Ds. < 13.2%.  相似文献   

6.
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD) was developed for extraction and determination of chloramphenicol (CAP) and thiamphenicol (THA) in honey. In this extraction method, 1.0 mL of acetonitrile (as dispersive solvent) containing 30 μL 1,1,2,2-tetrachloroethane (as extraction solution) was rapidly injected by syringe into a 5.00-mL water sample containing the analytes, thereby forming a cloudy solution. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the nature and volume of extraction solvent and dispersive solvent, extraction time, sample solution pH, sample volume and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 3 to 2000 μg kg−1 for target analytes. The enrichment factors for CAP and THA were 68.2 and 87.9, and the limits of detection (S/N = 3) were 0.6 and 0.1 μg kg−1, respectively. The relative standard deviations (RSDs) for the extraction of 10 μg kg−1 of CAP and THA were 4.3% and 6.2% (n = 6). The main advantages of DLLME-HPLC method are simplicity of operation, rapidity, low cost, high enrichment factor, high recovery, good repeatability and extraction solvent volume at microliter level. Honey samples were successfully analyzed using the proposed method.  相似文献   

7.
In this study, a sample pretreatment method was developed for the determination of 13 endocrine disrupting chemicals (EDCs) in sediment samples based on the combination of subcritical water extraction (SWE) and dispersed liquid–liquid microextraction (DLLME). The subcritical water that provided by accelerated solvent extractor (ASE) was the sample solution (water) for the following DLLME and the soluble organic modifier that spiked in the subcritical water was also used as the disperser solvent for DLLME in succession. Thus, several important parameters that affected both SWE and DLLME were investigated, such as the extraction solvent for DLLME (chlorobenzene), extraction time for DLLME (30 s), selection of organic modifier for SWE (acetone), volume of organic modifier (10%) and extraction temperature for SWE (150 °C). In addition, good chromatographic behavior was achieved for GC–MS after derivatisation by using N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA). As a result, proposed method sensitive and reliable with the limits of detection (LODs) ranging from 0.006 ng g−1 (BPA) to 0.639 ng g−1 (19-norethisterone) and the relative standard deviations (RSDs) between 1.5% (E2) and 15.0% (DES). Moreover, the proposed method was compared with direct ASE extraction that reported previously, and the results showed that SWE–DLLME was more promising with recoveries ranging from 42.3% (dienestrol) to 131.3% (4,5α-dihydrotestosterone), except for diethylstilbestrol (15.0%) and nonylphenols (29.8%). The proposed method was then successfully applied to determine 13 EDCs sediment of Humen outlet of the Pearl River, 12 of target compounds could be detected, and 10 could be quantitative analysis with the total concentration being 39.6 ng g−1, and which indicated that the sediment of Humen outlet was heavily contaminated by EDCs.  相似文献   

8.
In this study, a simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME) combined gas chromatography-electron capture detection (GC-ECD), for the determination of chlorobenzenes (CBs) in water samples, has been described. This method involves the use of an appropriate mixture of extraction solvent (9.5 μl chlorobenzene) and disperser solvent (0.50 ml acetone) for the formation of cloudy solution in 5.00 ml aqueous sample containing analytes. After extraction, phase separation was performed by centrifugation and the enriched analytes in sedimented phase were determined by gas chromatography-electron capture detection (GC-ECD). Our simple conditions were conducted at room temperature with no stiring and no salt addition in order to minimize sample preparation steps. Parameters such as the kind and volume of extraction solvent, the kind and volume of disperser solvent, extraction time and salt effect, were studied and optimized. The method exhibited enrichment factors and recoveries ranging from 711 to 813 and 71.1 to 81.3%, respectively, within very short extraction time. The linearity of the method ranged from 0.05 to 100 μg l−1 for dichlorobenzene isomers (DCB), 0.002-20 μg l−1 for trichlorobenzene (TCB) and tetrachlorobenzene (TeCB) isomers and from 0.001 to 4 μg l−1 for pentachlorobenzene (PeCB) and hexachlorobenzene (HCB). The limit of detection was in the low μg l−1 level, ranging between 0.0005 and 0.05 μg l−1. The relative standard deviations (R.S.D.s) for the concentration of DCB isomers, 5.00 μg l−1, TCB and TeCB isomers, 0.500 μg l−1, PeCB and HCB 0.100 μg l−1 in water by using the internal standard were in the range of 0.52-2.8% (n = 5) and without the internal standard were in the range of 4.6-6.0% (n = 5). The relative recoveries of spiked CBs at different levels of chlorobenzene isomers in tap, well and river water samples were 109-121%, 105-113% and 87-120%, respectively. It is concluded that this method can be successfully applied for the determination of CBs in tap, river and well water samples.  相似文献   

9.
Dispersive liquid–liquid microextraction (DLLME) coupled with high-performance liquid chromatography (HPLC)-UV detection was applied for the extraction and determination of bisphenol A (BPA) in water samples. An appropriate mixture of acetone (disperser solvent) and chloroform (extraction solvent) was injected rapidly into a water sample containing BPA. After extraction, sedimented phase was analyzed by HPLC-UV. Under the optimum conditions (extractant solvent: 142 μL of chloroform, disperser solvent: 2.0 mL of acetone, and without salt addition), the calibration graph was linear in the range of 0.5–100 μg L−1 with the detection limit of 0.07 μg L−1 for BPA. The relative standard deviation (RSD, n = 5) for the extraction and determination of 100 μg L−1 of BPA in the aqueous samples was 6.0%. The results showed that DLLME is a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of BPA in water samples and suitable results were obtained.  相似文献   

10.
A liquid-phase microextraction method for the determination of trihalomethanes (THMs) including chloroform (CHCl3), bromodichloromethane (CHBrCl2), dibromochloromethane (CHBr2Cl) and bromoform (CHBr3) in water samples was developed, with analysis by gas chromatography-electron capture detection (GC-ECD). After the determination of the most suitable solvent and stirring rate for the extraction, several other parameters (solvent drop volume, extraction time and ionic strength of the sample) were optimized using a factorial design to obtain the most relevant variables. The optimized extraction conditions for 5 mL of sample volume in a 10 mL vial were as follows: n-hexane an organic solvent; a solvent drop volume of 2 μL; an extraction time of 5.0 min; a stirring rate of 600 rpm at 25 °C; sample ionic strength of 3 M sodium chloride. The linear range was 1-75 μg L−1 for the studied THMs. The limits of detection (LODs) ranged from 0.23 μg L−1 (for CHBr2Cl) to 0.45 μg L−1 (for CHCl3). Recoveries of THMs from fortified distilled water were over 70% for a fortification level of 15 μg L−1, and relative standard deviations of the recoveries were below 5%. Real samples collected from tap water and well water were successfully analyzed using the proposed method. The recovery of spiked water samples was from 73% to 78% with relative standard deviations below 7%.  相似文献   

11.
In this article, a new ligandless dispersive liquid-liquid microextraction method has been developed for preconcentration of trace quantities of silver as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, like, extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, the calibration curve was linear in the range of 5.0 ng mL−1 to 2.0 μg mL−1 of silver with R2 = 0.9995 (n = 9) and detection limit based on three times the standard deviation of the blank (3Sb) was 1.2 ng mL−1 in original solution. The relative standard deviation for eight replicate determination of 0.5 μg mL−1 silver was ±1.5%. The high efficiency of dispersive liquid-liquid microextraction to carry out the determination of silver in complex matrices was demonstrated. The proposed method has been applied for determination of trace amount of silver in standard and water samples with satisfactory results.  相似文献   

12.
The paper described a new ionic liquid, 1,3-dibutylimidazolium hexafluorophosphate, as extraction solvent for extraction and preconcentration of organophosphorus pesticides (fenitrothion, parathion, fenthion and phoxim) from water and fruit samples by dispersive liquid–liquid microextraction combined with high-performance liquid chromatography. The effects of experimental parameters, such as extraction solvent volume, disperser solvent and its volume, extraction and centrifugal time, sample pH, extraction temperature and salt addition, on the extraction efficiency were investigated. An extraction recovery of over 75% and enrichment factor of over 300-fold were obtained under the optimum conditions. The linearity relationship was also observed in the range of 5–1000 μg L−1 with the correlation coefficients (r2) ranging from 0.9988 to 0.9999. Limits of detection were 0.01–0.05 μg L−1 for four analytes. The relative standard deviations at spiking three different concentration levels of 20, 100 and 500 μg L−1 varied from 1.3–2.7, 1.4–1.9 and 1.1–1.7% (n = 7), respectively. Three real samples including tap water, Yellow River water and pear spiked at three concentration levels were analyzed and yielded recoveries ranging from 92.7–109.1, 95.0–108.2 and 91.2–108.1%, respectively.  相似文献   

13.
A simple solvent microextraction method termed vortex-assisted liquid–liquid microextraction (VALLME) coupled with gas chromatography micro electron-capture detector (GC-μECD) has been developed and used for the pesticide residue analysis in water samples. In the VALLME method, aliquots of 30 μL toluene used as extraction solvent were directly injected into a 25 mL volumetric flask containing the water sample. The extraction solvent was dispersed into the water phase under vigorously shaking with the vortex. The parameters affecting the extraction efficiency of the proposed VALLME such as extraction solvent, vortex time, volumes of extraction solvent and salt addition were investigated. Under the optimum condition, enrichment factors (EFs) in a range of 835–1115 and limits of detection below 0.010 μg L−1 were obtained for the determination of target pesticides in water. The calculated calibration curves provide high levels of linearity yielding correlation coefficients (r2) greater than 0.9958 with the concentration level ranged from 0.05 to 2.5 μg L−1. Finally, the proposed method has been successfully applied to the determination of pesticides from real water samples and acceptable recoveries over the range of 72–106.3% were obtained.  相似文献   

14.
An on-line method, based on coupling dynamic ultrasonic extraction (DUE), continuously sampling the suspension of sample and solvent, high performance liquid chromatographic separation with diode array detection, has been developed for the determination of the flavonoids, including baicalin, baicalein and wogonin, from the root of Scutellaria baicalensis Georgi. Variables influencing the DUE were evaluated by orthogonal test. The extraction yields of baicalin, baicalein and wogonin in the roots of S. baicalensis Georgi obtained from five different cultivated areas are 73.8–131.5 μg mg−1 (RSD ≤ 6.24%), 6.8–15.9 μg mg−1 (RSD ≤ 5.36%) and 4.4–14.3 μg mg−1 (RSD ≤ 5.30%), respectively. The limits of detection for baicalin, baicalein and wogonin are 0.30, 0.37 and 0.41 μg mL−1, respectively. Linearity is from 0.55 to 109 μg mL−1 for baicalin, from 0.51 to 105 μg mL−1 for baicalein and from 0.53 to 102 μg mL−1 for wogonin. Compared with off-line continuous flow-DUE, the proposed method would be more convenient for the determination of the analytes and the rapid optimization of the extraction process. The extraction yields of flavonoids obtained by the proposed method are comparable with those obtained by dynamic microwave assisted extraction, static ultrasonic extraction and reflux extraction. The result indicated that the proposed method is suitable to determine the active components in Chinese herbal medicine.  相似文献   

15.
Bi W  Tian M  Row KH 《Talanta》2011,85(1):701-706
Ionic liquid-based extraction of medicinal or useful compounds from plants was investigated as an alternative to supercritical fluid, cloud point and conventional organic solvent extractions. The method integrated extraction and preconcentration. Medicinal products were first extracted by an ionic liquid solution, part of which was then converted to a hydrophobic form by anion metathesis for preconcentration. The remaining soluble ionic liquid acted as a dispersive agent to enhance the efficiency of preconcentration. Protein in the extract was precipitated spontaneously without addition of further solvents. Ultrasonication assisted this method for extraction and preconcentration of cryptotanshinone, tanshinone I and tanshinone II A from Salvia Miltiorrhiza Bunge. 0.233 mg g−1, 0.695 mg g−1 and 0.682 mg g−1 of each, respectively, were extracted using [OMIM][Cl], and preconcentrated in a [OMIM][PF6] phase at respective concentrations of 148.1, 507.1 and 486.1 μg mL−1. The method exhibited potential applicability with other medicinal products.  相似文献   

16.
Tsuyoshi Kagawa 《Talanta》2009,79(4):1001-1005
Isotope dilution mass spectroscopy (IDMS)/ICP-MS combined with microchip solvent extraction was successfully applied for the online determination of copper in an aluminum alloy. The microchip solvent extraction was developed for the separation of Cu from major element, and optimal pH range was wider than that of the batchwise extraction method. The dimensions of the microchip were 30 mm × 70 mm and that of micro-channel on the microchip was 180 μm wide and 40 μm deep. The copper complex with 8-hydroxyquinoline was extracted into o-xylene at pH 5.5 and back extracted with 0.1 mol l−1 nitric acid at flow rate of 20 μl min−1. The total extraction efficiency (water/organic solvent/nitric acid) was around 40%. IDMS/ICP-MS was coupled with solvent extraction for precise determination of Cu. The extraction and back-extraction on the microchip took about 1 s and the total measurement time for the IDMS/ICP-MS was about 40 s/sample. The blank value of this method was 0.1 ng g−1. The proposed method was used for the determination of Cu in Al standard materials (JSAC 0121-C, The Japan Society for Analytical Chemistry and 7074 Al alloy, Nippon Light Metal Co. Ltd.). The obtained analytical results are in good agreement with the certified values.  相似文献   

17.
Olivella MA 《Talanta》2006,69(1):267-275
An innovative analytical procedure for the analysis of polycyclic aromatic hydrocarbons (PAHs) from large-volume water samples is presented. It involves sample preparation, sampling and the elution process in an automated continuous procedure involving the ASE technique. Prior to sampling, a XAD-2 resin column is prepared on the basis of a commercial accelerated solvent extraction (ASE) cartridge so that the resin bed is permanently fixed. Then, the XAD column inside the ASE cartridge is cleaned and conditioned. The sampling procedure involves conventional filtration with subsequent isolation of dissolved PAHs on an XAD-2 resin contained in the ASE cartridge. After sampling, the XAD-2 resin content inside the cartridge is eluted by ASE without any further sample preparation and subsequently reused. In order to validate the procedure, the PAHs were isolated from water samples from the Lake Maggiore (North of Italy) using both XAD-2 resin adsorption and hexane liquid-liquid extraction according to the International Standard Methodology ISO 17993. The mean percentages of deviation between concentrations obtained by both methodologies range from 6% for benzo(a)pyrene to 15% for fluoranthene and benzo(b,k)fluoranthene. Compared to the traditional techniques, this procedure offers numerous practical advantages: easy to perform, fast, savings in solvent volume and in time, all steps are fully automated thus avoiding any XAD-2 resin manipulation during and between steps and moreover, low detection limits were provided (0.001 ng l−1 for chrysene, benzo(b,k)fluoranthene, benzo(a)pyrene, dibenz(a,h)anthracene, benzo(g,h,i)perylene and indeno(1,2,3-cd)pyrene, and 0.01 ng l−1 for acenaphthylene and fluoranthene).This procedure was developed in the frame of a project aimed at evaluating the diffuse input of organic contaminants in the Lake Maggiore.  相似文献   

18.
An automated system to perform liquid-liquid extraction is proposed, in which the effective mixture (the intimate contact) between the aqueous phase and the organic phase, as well as the separation of the phases, are carried out in a micro-batch glass extraction chamber. Sample, reagents and organic solvent are introduced into the glass extraction chamber by a peristaltic pump using air as carrier. The detection of the extracted species from the aqueous phase is made in a small volume (120-150 μl) of isobutyl methyl ketone (MIBK). The system allows enrichment factors of 2-10-fold. The proposed automatic system was evaluated for Cu(II) extraction based on complex formation between copper(II) and 1-(2′-pyridylazo)naphthol (PAN) in MIBK. When a volumetric ration of 2:1 (aqueous:organic) was implemented, copper was detected in the concentration range of 100-1600 μg l−1 (r = 0.9995) with a relative standard deviation of 2% (200 μg l−1, n = 5) and a detection limit of 20 μg l−1. The analytical curve was linear over the concentration range 25-500 μg l−1 (r = 0.9994) when a volumetric ratio of 10:1 was employed. With this ratio, the detection limit was 5.0 μg l−1 and the relative standard deviation was 6% (50 μg l−1, n = 5).  相似文献   

19.
Comitre AL  Reis BF 《Talanta》2005,65(4):846-852
A not expensive automatic flow system based on multicommutation and exploiting the liquid-liquid extraction methodology for the determination of lead in plant material is described. The spectrophotometric procedure for lead determination was based on the reaction with dithizone followed by extraction using an organic solvent. The facilities afforded by the multicommutation approach allowed the use of an air stream as carrier, thus contributing to reduce the overall waste generation. The results obtained analysing plant materials compare very well with those obtained employing inductive coupled plasma optical emission spectrometry (ICP OES) at 90% confidence level. Others profitable features such as a linear response range between 50 and 200 μg l−1 Pb (r = 0.999); a sampling rate of 15 determination per hour; a relative standard deviation of 1.8% (n = 12) for a typical sample containing 163 μg l−1 Pb; a detection limit of 12 μg l−1; a reagent consumption of 4.5 mg dithizone; and a waste generation of 225 μl organic solvent per determination were also achieved.  相似文献   

20.
In the present work, a new ligandless-dispersive liquid-liquid microextraction (LL-DLLME) method has been developed for preconcentration trace amounts of copper as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents, respectively. Some factors influencing on the extraction efficiency of copper and its subsequent determination were studied and optimized, such as the extraction and dispersive solvent type and volume, pH of sample solution, extraction time and salting out effect. Under the optimal conditions, the calibration curve was linear in the range of 1.0 ng mL−1-0.6 μg mL−1 of copper with R2 = 0.9985. Detection limit was 0.5 ng mL−1 in original solution (3Sb/m) and the relative standard deviation for seven replicate determination of 0.2 μg mL−1 copper was ±1.4%. The proposed method has been applied for determination of copper in standard and water samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号