首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Novel fused-LEDs devices as optical sensors for colorimetric analysis   总被引:1,自引:0,他引:1  
The development of a novel, low power optical sensing platform based on light emitting diodes (LEDs) is described. The sensor is constructed from a pair of LEDs fused together at an angle where one LED functions as the light source and the other LED is reverse biased to function as a light detector. Sensor function is based on the level of light received by the detector diode, which varies with the reflectance of the interface between the device and its environment, or the chemochromic membrane that covers the device. A simple microprocessor circuit is used to measure the time taken for the photon-induced current to discharge the detector LED from an initial 5 V (logic 1) to 1.7 V (logic zero). This sensing device has been successfully used for colour and colour-based pH measurements and offers extremely high sensitivity, enabling detection down to the sub micro molar level of dyes.  相似文献   

2.
A novel low power, low cost, highly sensitive, miniaturized light emitting diode (LED) based flow detector has been used as optical detector for the detection of sample components in high performance liquid chromatography (HPLC). This colorimetric detector employs two LEDs, one operating in normal mode as a light source and the other is reverse biased to work as a light detector. Instead of measuring the photocurrent directly, a simple timer circuit is used to measure the time taken for the photocurrent generated by the emitter LED (lambda(max) 500 nm) to discharge the detector LED (lambda(max) 621 nm) from 5 V (logic 1) to 1.7 V (logic 0) to give digital output directly without using an A/D converter. Employing a post-column reagent method, a Nucleosil 100-7 column (functionalized with iminodiacetic acid (IDA) groups) was used to separate a mixture of transition metal complexes, manganese(II) and cobalt(II) in 4-(2-pyridylazo)-resorcinol (PAR). All optical measurements were taken by using both the in-built HPLC variable wavelength detector and the proposed paired-emitter-detector-diode (PEDD) optical detector configured in-line for data comparison. The concentration range investigated using the PEDD was found to give a linear response to the Mn(II) and Co(II) PAR complexes. The effects of flow rate and emitter LED light source intensity were investigated. Under optimised conditions the PEDD detector offered a linear range of 0.9-100 microM and LOD of 0.09 microM for Mn-PAR complex. A linear range of 0.2-100 microM and LOD of 0.09 microM for Co-PAR complex was achieved.  相似文献   

3.
Feng-Bo Yang 《Talanta》2009,78(3):1155-203
In this work, a simple and low-cost miniaturized light-emitting diode induced fluorescence (LED-IF) detector based on an orthogonal optical arrangement for capillary electrophoresis (CE) was developed, using a blue concave light-emitting diode (LED) as excitation source and a photodiode as photodetector. A lens obtained from a waste DVD-ROM was used to focus the LED light beam into an ∼80 μm spot. Fluorescence was collected with an ocular obtained from a pen microscope at 45° angle, and passed through a band-pass filter to a photodiode detector. The performance of the LED-IF detector was demonstrated in CE separations using sodium fluorescein and fluorescein isothiocyanate (FITC)-labeled amino acids as model samples. The limit of detection for sodium fluorescein was 0.92 μM with a signal-to-noise ratio (S/N) of 3. The total cost of the LED-IF detector was less than $ 50.  相似文献   

4.
A miniaturized methodology for the determination of phosphate in waters has been developed by combining directly suspended droplet microextraction (DSDME) with microvolume spectrophotometry. The method is based on the extraction of the ion pair formed between 12-molybdophosphate and malachite green onto a microdrop of methyl isobutyl ketone and subsequent spectrophotometric determination with no dilution. An enrichment factor of 325 was obtained after 7.5 min of microextraction. The detection limit was 6.1 nM phosphate and the repeatability, expressed as relative standard deviation, was 2.7% (n = 6). The method was successfully applied to the determination of dissolved reactive phosphorus in different freshwater samples.  相似文献   

5.
O' Toole M  Lau KT  Diamond D 《Talanta》2005,66(5):1340-1344
A novel inexpensive optical-sensing technique has been developed for colorimetric flow analysis. This sensing system employs two LEDs whereby one is used as the light source and the other as a light detector. The LED used as light detector is reverse biased with a 5-V supply so that the photocurrent generated by the incident light discharges the capacitance. Direct digital output is provided by a simple timer circuit that measures the time taken for this discharge process from 5 V (logic 1) to 1.7 V (logic 0).

This sensing concept has been applied in flow analysis by constructing an optical flow cell with a pair of LEDs. Calibration of the integrated optical flow cell using a dye resulted in a linear response that obeys the Beer–Lambert law. The flow rate, dynamic range, sensitivity and limits of detection were investigated. The system was also used for pH determination in the range of pH 2.5–6.8 using bromocresol green (BCG). The pKa of BCG was successfully determined by this technique.  相似文献   


6.
In this work, a new type of miniaturized fibre-coupled solid-state light source is demonstrated as an excitation source for fluorescence detection in capillary electrophoresis. It is based on a parabolically shaped micro-light emitting diode (μ-LED) array with a custom band-pass optical interference filter (IF) deposited at the back of the LED substrate. The GaN μ-LED array consisted of 270 individual μ-LED elements with a peak emission at 470 nm, each about 14 μm in diameter and operated as a single unit. Light was extracted through the transparent substrate material, and coupled to an optical fibre (OF, 400 μm in diameter, numerical aperture NA = 0.37), to form an integrated μ-LED-IF-OF light source component. This packaged μ-LED-IF-OF light source emitted approximately 225 μW of optical power at a bias current of 20 mA. The bandpass IF filter was designed to reduce undesirable LED light emissions in the wavelength range above 490 nm. Devices with and without IF were compared in terms of the optical power output, spectral characteristics as well as LOD values. While the IF consisted of only 7.5 pairs (15 layers) of SiO2/HfO2 layers, it resulted in an improvement of the baseline noise as well as the detection limit measured using fluorescein as test analyte, both by approximately one order of magnitude, with a LOD of 1 × 10−8 mol L−1 obtained under optimised conditions. The μ-LED-IF-OF light source was then demonstrated for use in capillary electrophoresis with fluorimetric detection. The limits of detection obtained by this device were compared to those obtained with a commercial fibre coupled LED device.  相似文献   

7.
A versatile, simple, liquid core waveguide (LCW)-based fluorescence detector design is described for capillary systems. A Teflon AF coated fused silica capillary serves as the LCW. The LCW is transversely excited. The light source can be a conventional or high power (HP) light emitting diode (LED) or a laser diode (LD). The source can be coupled to the LCW directly or via an optical fiber. Fiber coupling is convenient if a high power (necessarily heat sink mounted) emitter is used. The LCW is concentrically placed within a slightly larger opaque jacket tube and the LCW terminates just short of the jacket terminus, which is sealed with an optical window. The influent liquid thus exits the LCW tip, flows back around the LCW through the jacket annulus to exit via an aperture on the jacket tube. The problem of coupling the emitted light efficiently to the photodetector is thus solved by placing the tip of the annular tubular assembly directly on the detector.For excitation wavelengths of 365 nm (LED/HPLED) and 405 nm (LD), the tris(8-hydroxyquinoline-5-sulfonic acid (sulfoxine)) chelate of aluminum (λem,max ∼ 500 nm) and Coumarin 30 were respectively used as the model analyte. For source-detector combinations comprising (a) a UV LED (∼1.5 mW @ 15 mA) and a photodiode, (b) a LD (∼5 mW, abstracted from a “Blu-Ray” recorder) and a miniature photomultiplier tube (mPMT), and (c) a high power (210 mW @ 500 mA) surface-mount HPLED-mPMT, the S/N = 3 LODs were, respectively, 1.7 pmol Al, 3-100 fmol Coumarin 30 (depending on laser intensity and integration time), and 4 fmol Al. In the last case, the relative standard derivation (R.S.D.) at the 20 fmol level was 1.5% (n = 10).  相似文献   

8.
Sun M  Du WB  Fang Q 《Talanta》2006,70(2):392-396
In this work, a miniaturized liquid-liquid extraction system under stopped-flow manipulation mode with spectrometric detection was developed. A Teflon AF liquid-core waveguide (LCW) capillary was used to serve as both extraction channel for organic solvent flow and adsorption detection flow cell. Gravity induced hydrostatic pressure was used to drive the organic and aqueous phases through the extraction channels. During extraction process, a stable organic and aqueous phase interface was formed at the outlet of the capillary, through which the analyte in the flowing aqueous stream was extracted into the stationary organic solvent in capillary. The absorbance of the analyte extracted into the organic solvent was measured in situ by a spectrometric detection system with light emitting diode (LED) as light source and photodiode as absorbance detector. The performance of the system was demonstrated in the determination of sodium dodecyl sulfate (SDS) extracted as an ion pair with methylene blue into chloroform. The precision of the measured absorbance for a 5 mg L−1 SDS standard was 6.1% R.S.D. (n = 5). A linear response range of 1-10 mg L−1 SDS was obtained with 5 min extraction period. The limit of detection (LOD) for SDS based on three times standard deviation of the blank response was 0.25 mg L−1.  相似文献   

9.
Yang B  Tian H  Xu J  Guan Y 《Talanta》2006,69(4):996-1000
An integrated light emitting diode (LED)-induced fluorescence detector was described and evaluated. The LED and its related components including lens and interference filter, the optical fiber used to collect fluorescence, and the capillary column are integrated into a substrate block, which eliminates the need of align procedure of the fiber and the capillary. Forty-fold enhancement of sensitivity was obtained compared with our previous work and the detection limit for fluorescein was 5 nM. Application of the detector for the analysis of FITC-labeled Ephedrine extract was demonstrated.  相似文献   

10.
Zhang T  Fang Q  Wang SL  Qin LF  Wang P  Wu ZY  Fang ZL 《Talanta》2005,68(1):19-24
The signal-to-noise level of light emitting diode (LED) fluorimetry using a liquid-core-waveguide (LCW)-based microfluidic capillary electrophoresis system was significantly enhanced using a synchronized dual wavelength modulation (SDWM) approach. A blue LED was used as excitation source and a red LED as reference source for background-noise compensation in a microfluidic capillary electrophoresis (CE) system. A Teflon AF-coated silica capillary served as both the separation channel and LCW for light transfer, and blue and red LEDs were used as excitation and reference sources, respectively, both radially illuminating the detection point of the separation channel. The two LEDs were synchronously modulated at the same frequency, but with 180°-phase shift, alternatingly driven by a same constant current source. The LCW transferred the fluorescence emission, as well as the excitation and reference lights that strayed through the optical system to a photomultiplier tube; a lock-in amplifier demodulated the combined signal, significantly reducing its noise level. To test the system, fluorescein isothiocyanate (FITC)-labeled amino acids were separated by capillary electrophoresis and detected by SDWM and single wavelength modulation, respectively. Five-fold improvement in S/N ratio was achieved by dual wavelength modulation, compared with single wavelength modulation; and over 100-fold improvement in S/N ratio was achieved compared with a similar LCW-CE system reported previously using non-modulated LED excitation. A detection limit (S/N = 3) of 10 nM FITC-labeled arginine was obtained in this work. The effects of modulation frequency on S/N level and on the rejection of noise caused by LED-driver current and detector were also studied.  相似文献   

11.
A new system for CO2 measurement (0–100%) based on a paired emitter–detector diode arrangement as a colorimetric detection system is described. Two different configurations were tested: configuration 1 (an opposite side configuration) where a secondary inner-filter effect accounts for CO2 sensitivity. This configuration involves the absorption of the phosphorescence emitted from a CO2-insensitive luminophore by an acid–base indicator and configuration 2 wherein the membrane containing the luminophore is removed, simplifying the sensing membrane that now only contains the acid–base indicator. In addition, two different instrumental configurations have been studied, using a paired emitter–detector diode system, consisting of two LEDs wherein one is used as the light source (emitter) and the other is used in reverse bias mode as the light detector. The first configuration uses a green LED as emitter and a red LED as detector, whereas in the second case two identical red LEDs are used as emitter and detector. The system was characterised in terms of sensitivity, dynamic response, reproducibility, stability and temperature influence. We found that configuration 2 presented a better CO2 response in terms of sensitivity.  相似文献   

12.
In this paper, a novel detection reagent for formaldehyde determination is proposed, and is applied to a simple and highly sensitive flow injection method for the spectrophotometric determination of formaldehyde. The method is based on the reaction of formaldehyde with methyl acetoacetate in the presence of ammonia. The increase in the absorbance of the reaction product was measured at 375 nm. An inexpensive light emitting diode (LED)-based UV detector (375 nm) was, for the first time, used. Under the optimized experimental conditions, formaldehyde in an aqueous solution was determined over the concentration range from 0.25 to 20.0 × 10−6 M with a liner calibration graph; the limit of detection (LOD) of 5 × 10−8 M (1.5 μg L−1) was possible. The relative standard deviation of 12 replicate measurements of 5 × 10−6 M formaldehyde was 1.2%. Maximum sampling throughput was about 21 samples/h. The effect of potential interferences such as metals, organic compounds and other aldehyde was also examined. The analytical performance for formaldehyde determination was compared with those obtained by the conventional acetylacetone method, which uses visible absorption spectrophotometry. Finally, the proposed method was successfully applied to the determination of formaldehyde in natural water samples.  相似文献   

13.
Chen G  Zhang L  Wang J 《Talanta》2004,64(4):1018-1023
Multi-walled carbon nanotube (CNT) was mixed with epoxy to fabricate microdisc electrode used as a detector for a specially designed miniaturized capillary electrophoresis (CE)-amperometric detection system for the separation and detection of several bioactive thiols. The end-channel CNT amperometric detector offers favourable signal-to-noise characteristics at a relatively low potential (0.8 V) for detecting thiol compounds. Factors influencing the separation and detection processes were examined and optimized. Four thiols (homocysteine, cysteine, glutathione, and N-acetylcysteine) have been separated within 130 s at a separation voltage of 2000 V using a 20 mM phosphate running buffer (pH 7.8). Highly linear response is obtained for homocysteine, cysteine, glutathione, and N-acetylcysteine over the range of 5-50 μM with detection limits of 0.75, 0.8, 2.9, and 3.3 μM, respectively. Good stability and reproducibility (R.S.D. < 5%) are obtained reflecting the minimal adsorption of thiols at the CNT electrode surface. The new microchip protocol should find a wide range of bioanalytical applications involving assays of thiol compounds.  相似文献   

14.
We report a new, solid-state, integrated optical array sensor platform. By using pin printing technology in concert with sol-gel-processing methods, we form discrete xerogel-based microsensor elements that are on the order of 100 μm in diameter and 1 μm thick directly on the face of a light emitting diode (LED). The LED serves as the light source to excite chemically responsive luminophores sequestered within the doped xerogel microsensors and the analyte-dependent emission from within the doped xerogel is detected with a charge coupled device (CCD). We overcome the problem of background illumination from the LED reaching the CCD and the associated biasing that results by coating the LED first with a thin layer of blue paint. The thin paint layer serves as an optical filter, knocking out the LEDs red-edge spectral tail. The problem of the spatially-dependent fluence across the LED face is solved entirely by performing ratiometric measurements. We illustrate the performance of the new sensor scheme by forming an array of 100 discrete O2-responsive sensing elements on the face of a single LED. The combination of pin printing with an integrated sensor and light source platform results in a rapid method of forming (∼1 s per sensor element) reusable sensor arrays. The entire sensor array can be calibrated using just one sensor element. Array-to-array reproducibly is <8%. Arrays can be formed using single or multiple pins with indistinguishable analytical performance.  相似文献   

15.
Wu J  Liu X  Wang L  Dong L  Pu Q 《The Analyst》2012,137(2):519-525
An economical fluorescence detector was developed with an LED as the exciting source and a low-cost avalanche photodiode (APD) module as a photon sensor. The detector was arranged in an epifluorescence configuration using a microscope objective (20× or 40×) and a dichroic mirror. The low-cost APD was biased by a direct current (DC) high voltage power supply at 121 V, which is much lower than that normally used for a PMT. Both DC and square wave (SW) supplies were used to power the LED and different data treatment protocols, such as simple average for DC mode, software based lock-in amplification and time specific average for SW mode, were tested to maximize the signal-to-noise ratio. Using an LED at a DC mode with simple data averaging, a limit of detection of 0.2 nmol L(-1) for sodium fluorescein was attained, which is among the lowest ever achieved with an LED as an excitation source. The detector was successfully used in both capillary and chip electrophoresis. The most significant advantages of the detector are the compact size and low cost of its parts. The aim of the work is to prove that widely available, low-cost components for civilian use can be successfully used for miniaturized analytical devices.  相似文献   

16.
A novel and sensitive cloud point extraction procedure using pH-sensitive hydrogel was developed for preconcentration and spectrophotometric determination of trace amounts of malachite green (MG). In this extraction method, appropriate amounts of poly(styrene-alt-maleic acid), as a pH-sensitive hydrogel, and HCl were added respectively into the aqueous sample so a cloudy solution was formed. The cloudy phase consists of hydrogel particles distributed entirely into the aqueous phase. Organic or inorganic compounds having the potential to interact with polymer particles (chemical interaction or physical adsorption) could be extracted to cloudy phase. After centrifuging, these particles of hydrogel were sedimented in the bottom of sample tube. The sedimented hydrogel-rich phase was diluted with acetonitrile and its absorbance was measured at 617 nm (λmax of malachite green in hydrogel). Central composite design and response surface method were applied to design the experiments and optimize the experimental parameters such as, concentration of hydrogel and HCl, extraction time and salting out effect. Under the optimum conditions, the linear range was 1 × 10−8-5 × 10−7 mol L−1 malachite green with a correlation coefficient of 0.992. The limit of detection (S/N = 3) was 4.1 × 10−9 mol L−1. Relative standard deviation (RSD) for 7 replicate determinations of 10−7 mol L−1 malachite green was 3.03%. In this work, the concentration factor of 20 was reached. Also the improvement factor of the proposed method was 23. The advantages of this method are simplicity of operation, rapidity and low cost.  相似文献   

17.
X Z Wu  S K Sze  J Pawliszyn 《Electrophoresis》2001,22(18):3968-3971
Miniaturization of whole-column imaging capillary isoelectric focusing (CIEF) is discussed. A 1.2 cm capillary was used as a separation column for CIEF. The experimental results for the analysis of two pI markers and the protein myoglobin showed that good CIEF separation results could be obtained. Secondly, a light-emitting diode (LED) was used as the light source for the whole-column absorbance imaging detection. The focusing of both the pI markers and myoglobin were observed with the LED light source. The whole-column imaging CIEF instrument was simplified and miniaturized by the use of the LED. Further developments are also discussed.  相似文献   

18.
Novel orange phosphor of Eu2+-activated calcium chlorosilicate was synthesized at 1273 K by conventional solid-state reactions under reductive atmosphere and investigated by means of photoluminescence excitation, diffuse reflectance and emission spectroscopies. These results show that this phosphor can be efficiently excited by the incident light of 300-450 nm, well matched with the emission band of 395 nm-emitting InGaN chip, and emits an intense orange light peaking at 585 nm. By combining this phosphor with a 395 nm-emitting InGaN chip, an intense orange light-emitting diode (LED) was fabricated. Under 20 mA forward-bias current, its CIE chromaticity coordinates are (0.486, 0.446). The dependence of as-fabricated orange LED on forward-bias current indicates that it shows excellent chromaticity stability and luminance saturation. These results show that this Eu2+-activated calcium chlorosilicate is a promising orange-emitting phosphor for near-ultraviolet (UV) InGaN-based white LED.  相似文献   

19.
This study employed a new light source, a light-emitting diode (LED), for fluorescence detection of high-performance liquid chromatography to measure the concentration of trace constituents in biological fluids. Using l-3-hydroxybutyrate ( l-3HB) as a tested trace compound, the function of the new system was compared with that of the current commercially available model. A detailed schematic diagram of the path of the detection rays in the LED detector is given. A voltage-stabilizer for the drive circuit was designed with an input of 10 V and an output of 8 V, and another voltage regulator was used to maintain a constant 8 V. Then the regulator was used to set the output voltage for the LED at 2.8 V by two external resistors. Replacing the xenon lamp with LED, this system provided higher photon density and a narrow spectrum at a wavelength of 491 nm. At room temperature (22.1°C), the average temperature of six places in the chamber of LED detector was 22.1°C compared with 51.1°C in the xenon detector. The spectra of the excitation light sources were measured. Compared with the xenon lamp, approximately 1.32 times higher excitation intensity was obtained by the LED source. The accuracy of detection of l-3HB in 50 μL of rat serum was 99.85-100.85%, and the intra-day and inter-day precision values were within 8.99 and 13.90%, respectively. The limit of detection of l-3HB was approximately 0.73 μM (signal-to-noise ratio 3). The sensitivity of the proposed LED detector was comparable to that of traditional fluorescence detectors using xenon arc lamps; however, the cost and operating temperature of LED lamps were far lower. This assay system could be further used to detect trace constituents in various samples.  相似文献   

20.
We describe a light emitting diode (LED) based multi-reflection capillary scale absorbance detector based on both square and round capillaries and compare their performance with a conventional single-pass on-tube detector. The optical path length is extended by silver coating, the external surface of the capillary. The reflective geometry has been reported to be less prone to artifacts induced by refractive index changes; we do find this to be true. Although the detection volume/illuminated volume is increased some, a multi-reflection cell based on a 180 μm bore capillary with a ∼2-cm long illuminated volume shows over a 50-fold gain in signal-to-noise (S/N) compared to a single-pass on-tube configuration with the same capillary. The limit of detection (LOD) is 4.4 fmol (2.6 pg, 1 μL of 22.0 nM injected dye) BTB under pulseless (pneumatic) flow conditions. The cells behave as multipath devices where the effective path lengths are greater at low absorbance values. In our experiments, where non-coherent light is launched through optical fibers that are large compared to capillary bore dimensions, increase in the effective path length of the cell do not occur in a predictable fashion with the angle of incidence of the light beam. Although the effective path length almost linearly increases with increasing distance between the light entry and exit windows, the absolute values of the effective path lengths are always lower than this physical distance, suggesting that after some passage through the solution, light largely travels through or along the glass wall. Square capillaries have better light transmission and offer some performance advantages. Multi-reflection cells can indeed be of value for sensitive detection in microflow systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号