首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liu Y  Liang P  Guo L 《Talanta》2005,68(1):25-30
Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer TiO2) was prepared by sol-gel method and characterized by using X-ray diffraction (XRD) and scanning electron microscope (SEM). The adsorptive potential of immobilized nanometer TiO2 for the preconcentration of trace Cd, Cr, Cu and Mn was assessed in this work. The metal ions studied can be quantitative retained at a pH range of 8-9, and 0.5 mol L−1 HNO3 was sufficient for complete elution. The adsorption capacity of immobilized nanometer TiO2 for Cd, Cr, Cu and Mn was found to be 2.93, 2.11, 6.69 and 2.47 mg g−1, respectively. A new method using a microcolumn packed with immobilized nanometer TiO2 as sorbent has been developed for the preconcentration of trace amounts of Cd, Cr, Cu and Mn prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). The method has been successfully applied for the determination of trace elements in some environmental samples with satisfactory results.  相似文献   

2.
In the present work, a new ligandless-dispersive liquid-liquid microextraction (LL-DLLME) method has been developed for preconcentration trace amounts of copper as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents, respectively. Some factors influencing on the extraction efficiency of copper and its subsequent determination were studied and optimized, such as the extraction and dispersive solvent type and volume, pH of sample solution, extraction time and salting out effect. Under the optimal conditions, the calibration curve was linear in the range of 1.0 ng mL−1-0.6 μg mL−1 of copper with R2 = 0.9985. Detection limit was 0.5 ng mL−1 in original solution (3Sb/m) and the relative standard deviation for seven replicate determination of 0.2 μg mL−1 copper was ±1.4%. The proposed method has been applied for determination of copper in standard and water samples with satisfactory results.  相似文献   

3.
The present article reports on the application of modified multiwalled carbon nanotubes (MMWCNTs) as a new, easily prepared and stable solid sorbent for the preconcentration of trace rhodium ion in aqueous solution. Rhodium ions were complexed with 1-(2-pyridylazo)-2-naphthol (PAN) in the pH range of 3.2-4.7 and then the formed Rh-PAN complex was adsorbed on the oxidized MWCNTs. The adsorbed complex was eluted from MWCNTs sorbent with 5.0 mL of N,N-dimethylformamide (DMF). The rhodium in eluted solution was determined by flame atomic absorption spectrometry (FAAS). Linear range for the determination of rhodium was maintained between 0.16 ng mL−1 and 25.0 μg mL−1 in initial solution. Relative standard deviation for the 10 replicated determination of 4.0 μg mL−1 of rhodium was ±0.97%. Detection limit was 0.010 ng mL−1 in initial solution (3Sbl, n = 10) and preconcentration factor was 120. Sensitivity for 1% absorbance of rhodium (III) was 0.112 μg mL−1. The sorption capacity of oxidized MWCNTs for Rh (III) was 6.6 mg g−1. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type, breakthrough volume and interference ions were studied for the preconcentration of Rh3+. The proposed method was successfully applied to the extraction and determination of rhodium in different samples.  相似文献   

4.
A simple and highly selective flow injection (FI) on-line preconcentration and separation flame atomic absorption spectrometric (FAAS) method was developed for the determinations of trace amounts of silver, gold and palladium. The selective preconcentration of the noble metals was achieved in a wide range of sample acidity (0.1-6 M HNO3 or HCl) on a microcolumn packed with amidinothioureido-silica gel (ATuSG). The analytes retained on the column were effectively eluted with 5.0% thiourea solution. The analytical procedure was optimized for sample acidity, elution, interferences, flow rate of sampling and eluting, and concentration of sample. Common co-existing cations and anions did not interfere with the preconcentration and determination of the three metals. At a sample loading flow rate of 4.5 ml min−1 with 60 s preconcentration, detection limits (3σ) of 1.1 ng ml−1 Ag, 13 ng ml−1 Au and 17 ng ml−1 Pd were obtained. The precisions (R.S.D., n=11) were 1.2% for Ag, 1.2% for Au and 1.7% for Pd, respectively. The detection limits can be further improved by increasing sample volume. The analytical results obtained by the proposed method for a number of standard reference materials were in good agreement with the certified values.  相似文献   

5.
In this article, a new ligandless dispersive liquid-liquid microextraction method has been developed for preconcentration of trace quantities of silver as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, like, extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, the calibration curve was linear in the range of 5.0 ng mL−1 to 2.0 μg mL−1 of silver with R2 = 0.9995 (n = 9) and detection limit based on three times the standard deviation of the blank (3Sb) was 1.2 ng mL−1 in original solution. The relative standard deviation for eight replicate determination of 0.5 μg mL−1 silver was ±1.5%. The high efficiency of dispersive liquid-liquid microextraction to carry out the determination of silver in complex matrices was demonstrated. The proposed method has been applied for determination of trace amount of silver in standard and water samples with satisfactory results.  相似文献   

6.
A novel and sensitive extraction procedure using maghemite nanoparticles (γ-Fe2O3) modified with sodium dodecyl sulfate (SDS), as an efficient solid phase, was developed for removal, preconcentration and spectrophotometric determination of trace amounts of malachite green (MG) and leuco-malachite green (LMG). Combination of nanoparticle adsorption and easily magnetic separation was used to extraction and desorption of MG and LMG. The adsorption capacity was evaluated using both the Langmuir and Freundlich adsorption isotherm models. Maghemite nanoparticles were prepared by co-precipitation method and their surfaces were modified by SDS. The size and properties of the produced maghemite nanoparticles was determined by X-ray diffraction (XRD) analysis, scanning electron microscopy (SEM) and BET analysis. MG and LMG became adsorbed at pH 3.0. LMG was oxidized to MG by adsorption on maghemite nanoparticles. The adsorbed MG was then desorbed and determined spectrophotometrically. The calibration graph was linear in the range 0.50-250.00 ng mL−1 of MG and LMG with a correlation coefficient of 0.9991. The detection limit of the method for determination of MG was 0.28 ng mL−1 and the relative standard deviation (R.S.D.) for 10.00 and 50.00 ng mL−1 of malachite green was 1.60% (n = 3) and 0.86% (= 5), respectively. A preconcentration factor of 50 was achieved in this method. The Langmuir adsorption capacity (qmax) was found to be 227.3 mg g−1 of the adsorbent. The method was applied to the determination of MG in fish farming water samples.  相似文献   

7.
Arpa Şahin C  Durukan I 《Talanta》2011,85(1):657-661
In this article, a new ligandless solidified floating organic drop microextraction (LL-SFODME) method has been developed for preconcentration of trace amount of cadmium as a prior step to its determination by flow injection-flame atomic absorption spectrometry (FI-FAAS). The methodology is based on the SFODME of cadmium with 1-dodecanol in the absence of chelating agent. Several factors affecting the microextraction efficiency, such as, pH, sodium dodecylbenzenesulfonate (SDBS) concentration, extraction time, stirring rate and temperature were investigated and optimized. Under optimized experimental conditions an enhancement factor of 205 was obtained for 100 mL of sample solution. The calibration graph was linear in the range of 1.0-25.0 ng mL−1, the limit of detection (3s) was 0.21 ng mL−1 and the limit of quantification (10s) was 0.62 ng mL−1. The relative standard deviation (RSD) for 10 replicate measurements of 10 ng mL−1 cadmium was 4.7%. The developed method was successfully applied to the extraction and determination of cadmium in standard and several water samples and satisfactory results were obtained.  相似文献   

8.
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of atrazine and simazine. Atrazine and simazine were preconcentrated on heat-treated diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recoveries of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100 mL of validation solution containing 1.5 μg of triazines and 5 mL of ethanol as an eluent. Recoveries of atrazine and simazine were 95.7 ± 4.2% and 75.0 ± 1.9% with a relative standard deviation for seven determinations of 4.7% and 2.7% under optimum conditions. The maximum preconcentration factor was 100 for triazines when 500 mL of sample solution volume was used. The linear ranges of calibration curves for atrazine and simazine were 1-150 ng mL−1 and 1-300 ng mL−1, respectively, with correlation coefficients of 0.999 and the detection limits (3Signal-to-Noise) were 0.24 ng mL−1 and 0.21 ng mL−1 for atrazine and simazine. The capacity of the adsorbent was also examined and found to be 0.8 mg g−1 and 1.3 mg g−1 for atrazine and simazine, respectively. The proposed method was successfully applied to the determination of triazines in river water and tap water samples with high precision and accuracy.  相似文献   

9.
Determination of estrogens in water by HPLC-UV using cloud point extraction   总被引:1,自引:0,他引:1  
Wang L  Cai YQ  He B  Yuan CG  Shen DZ  Shao J  Jiang GB 《Talanta》2006,70(1):47-51
A method based on cloud point extraction was developed to determine four kinds of estrogens: estriol (E3), estradiol (E2), estrone (E1), and progesterone (P) in water by high performance liquid chromatography separation and ultraviolet detection (HPLC-UV). The non-ionic surfactant Triton X-114 was chosen as extractant solvent. The parameters affecting extraction efficiency, such as concentrations of Triton X-114 and Na2SO4, equilibration temperature, equilibration time and centrifugation time were evaluated and optimized. Under the optimum conditions, preconcentration factors of 99 for E3, 73 for E2, 152 for E1 and 86 for P were obtained for 10 mL water sample. The detection of limitation was 0.23 ng mL−1 for E3, 0.32 ng mL−1 for E2, 0.25 ng mL−1 for E1 and 5.0 ng mL−1 for P. The proposed method was successfully applied to the determination of trace amount of estrogens in wastewater treatment plant (WWTP) effluent water and exposure water with 10 ng mL−1 E2 for toxicological study in our lab. For the case of WWTP effluent water samples, no estrogen was found. The accuracy of the proposed method was tested by recovery measurements of spiked samples and good recoveries of 81.2-99.5% were obtained.  相似文献   

10.
A new micelle-mediated extraction method for preconcentration of ultra-trace quantities of beryllium and aluminum as a prior step to their simultaneous spectrophotometric determination has been developed. Chrome Azurol S (CAS), cetyltrimethylammonium bromide (CTAB) and Triton X-114 were used as chelating agent, cationic surfactant for extraction and co-extraction agent, respectively. Mean centering (MC) of ratio spectra has been used for simultaneous analysis of beryllium and aluminum. The optimal extraction and reaction conditions were studied, and the analytical characteristics of the method (e.g., limit of detection, linear range, preconcentration, and improvement factors) were obtained. Linearity was obeyed in the range of 5-40 ng mL−1 of beryllium and 3-100 ng mL−1 of aluminum. The detection limit of the method is 0.98 and 0.52 ng mL−1 for beryllium and aluminum, respectively. The interference effect of some anions and cations was also tested. The method was applied to the simultaneous determination of beryllium in water samples.  相似文献   

11.
A new method for solid-phase extraction and preconcentration of trace amounts Hg(II) from environmental samples was developed by using sodium dodecyle sulphate-coated magnetite nanoparticles (SDS-coated Fe3O4 NPs) as a new extractant. The procedure is based on the adsorption of the analyte, as mercury-Michler's thioketone [Hg2(TMK)4]2+ complex on the negatively charged surface of the SDS-coated Fe3O4 NPs and then elution of the preconcentrated mercury from the surface of the SDS-coated Fe3O4 NPs prior to its determination by flow injection inductively coupled plasma-optical emission spectrometry. The effects of pH, TMK concentration, SDS and Fe3O4 NPs amounts, eluent type, sample volume and interfering ions on the recovery of the analyte were investigated. Under optimized conditions, the calibration curve was linear in the range of 0.2-100 ng mL−1 with r2 = 0.9994 (n = 8). The limit of detection for Hg(II) determination was 0.04 ng mL−1. Also, relative standard deviation (R.S.D.) for the determination of 2 and 50 ng mL−1 of Hg(II) was 5.2 and 4.7% (n = 6), respectively. Due to the quantitative extraction of Hg(II) from 1000 mL of the sample solution an enhancement factor as large as 1230-fold can be obtained. The proposed method has been validated using a certified reference materials, and also the method has been applied successfully for the determination of Hg(II) in aqueous samples.  相似文献   

12.
In the present study a cloud point extraction process using mixed micelle of the cationic surfactant cetyl-pyridinium chloride (CPC) and non-ionic surfactant Triton X-114 for extraction of beryllium from aqueous solutions is developed. The extraction of analyte from aqueous samples was performed in the presence of 1,8-dihydroxyanthrone as chelating agent in buffer media of pH 9.5. After phase separation, the surfactant-rich phase was diluted with 0.4 mL of a 60:40 methanol-water mixture containing 0.03 mL HNO3. Then, the enriched analyte in the surfactant-rich phase was determined by inductively coupled plasma-atomic emission spectrometry (ICP-AES). The different variables affecting the complexation and extraction conditions were optimized. Under the optimum conditions (i.e. 1.6 × 10−4 mol L−1 1,8-dihydroxyanthrone, 1.2 × 10−4 mol L−1 CPC, 0.15% (v/v) Triton X-114, 50 °C equilibrium temperature) the calibration graph was linear in the range of 0.006-80 ng mL−1 with detection limit of 0.001 ng mL−1 and the precision (R.S.D.%) for five replicate determinations at 18 ng mL−1 of Be(II) was better than 2.9%. In this manner the preconcentration and enrichment factors were 16.7 and 24.8, respectively. Under the presence of foreign ions no significant interference was observed. Finally, the proposed method was successfully utilized for the determination of this cation in water samples.  相似文献   

13.
The effect of dimensions (length and external diameter) of multi-walled carbon nanotubes (MWCNTs) on its preconcentration efficiency towards some metal ions (Pb2+, Cd2+, Cu2+, Zn2+ and MnO4) from environmental waters prior to their analysis by flame atomic absorption spectroscopy (FAAS) was investigated. MWCNTs (as-received from the manufacturer) of various external diameters and lengths were involved. Other variables optimized included effects of pH of water sample, composition and volume of eluent, mass of the MWCNTs, breakthrough volume and coexisting ions. Maximum recovery of metal ions was obtained at pH 9 where it was thought that precipitation of metals as their hydroxides played the major factor in metals uptake by MWCNT. It was suggested that the use of appropriate dimensions of MWCNTs may support the trapping process of the precipitated metal hydroxides by MWCNTs. It was found that long MWCNT of length 5-15 μm and external diameter 10-30 nm gave the highest enrichment efficiency towards almost all the targeted metal ions. It could be used for preconcentration of MnO4, Cu2+, Zn2+ and Pb2+ with almost full recovery; but not for Cd2+ due to its low recovery. The optimized solid phase extraction (SPE) procedure was capable of determining metal ions in the linear range 20-100 ng mL−1 (except for Zn2+ from 20 to 150 ng mL−1). Detection limits were 0.709 ng mL−1 for MnO4, 0.278 ng mL−1 for Pb2+, 0.465 ng mL−1 for Cu2+, 0.867 ng mL−1 for Zn2+. Application of the optimized SPE procedure to environmental waters (tap water, reservoir water and stream water) gave spike recoveries of the metals in the range of 81-100%.  相似文献   

14.
This paper introduces strategies for enhancement of a surface plasmon resonance (SPR) signal by adopting colloidal gold nanoparticles (AuNPs) and a SiO2 layer on a gold surface. AuNPs on SiO2 on a gold surface were compared with an unmodified gold surface and a SiO2 layer on a gold surface with no AuNPs attached. The modified surfaces showed significant changes in SPR signal when biomolecules were attached to the surface as compared with an unmodified gold surface. The detection limit of AuNPs immobilized on a SPR chip was 0.1 ng mL−1 for the prostate-specific antigen (PSA), a cancer marker, as measured with a spectrophotometer. Considering that the conventional ELISA method can detect ∼10 ng mL−1 of PSA, the strategy described here is much more sensitive (∼100 fold). The enhanced shift of the absorption curve resulted from the coupling of the surface and particle plasmons by the SiO2 layer and the AuNPs on the gold surface.  相似文献   

15.
A quick and reproducible electrochemical-based immunosensor technique, using magnetic core/shell particles that are coated with self-assembled multilayer of nanogold, has been developed. Magnetic particles that are structured from Au/Fe3O4 core-shells were prepared and aminated after a reaction between gold and thiourea, and additional multilayered coatings of gold nanoparticles were assembled on the surface of the core/shell particles. The carcinoembryonic antibody (anti-CEA) was immobilized on the modified magnetic particles, which were then attached on the surface of solid paraffin carbon paste electrode (SPCE) by an external magnetic field. This is an assembly of a novel immuno biosensor for carcinoembryonic antigen (CEA). The sensitivity and response features of this immunoassay are significantly affected by the surface area and the biological compatibility of the multilayered nanogold. The linear range for the detection of CEA was from 0.005 to 50 ng mL−1 and the limit of detection (LOD) was 0.001 ng mL−1. The LOD is approximately 500 times more sensitive than that of the traditional enzyme-linked immunosorbent assay for CEA detection.  相似文献   

16.
In this work, a new type of sorbent (low density polyhydroxy polyurethane Foam, LPPF) was synthesis by using water hydrolysis of polyurethanediazonium chloride salt. LPPF was characterized using different tools e.g. elemental analysis, UV–vis and IR spectra, TGA, SEM, density and pHZPC. It was tested for separation, preconcentration and determination of gold in environmental samples using batch and dynamic techniques. The sorption experimental data was fitted by the pseudo-first kinetic mathematical equation (R2 = 0.991). The sorption rate of the Au (III) ions is very fast, the half-life (t1/2) ≈ 34 s. The equilibrium process is well described by the Freundlich isotherm model, the R2 value is 0.967, which attributed to the heterogeneous surface structure of the LPPF. The breakthrough capacity of LPPF and the recovery of gold ions were 0.36 mmol g−1 (70.5 mg g−1) and 99–100%, respectively. The lower detection limit of gold by using spectrophotometric method is 3.3 ng L−1 with preconcentration factors ≈ 450 (RSD ∼ 1.66%, n = 4). The values of ΔG and ΔH for the sorption of gold onto LPPF were −12.5 and −103.5 kJ mol−1, respectively, which indicate that the sorption of Au (III) onto LPPF is spontaneous and exothermic reaction. The obtained results indicate that the ion chelation and ion association might be the most probable mechanism of gold sorption onto LPPF. The study shows LPPF has the potential of application as an efficient sorbent for the extraction and determination of gold in water, gold alloys pharmaceutical and granite samples.  相似文献   

17.
A new method using dithizone-modified TiO2 nanoparticles (nanometer TiO2-DZ) as solid-phase extractant has been developed for the simultaneous preconcentration of trace amounts of chromium and lead prior to their measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). The preconcentration conditions of the analytes, including the effects of pH, sample flow rate and volume, elution conditions and interfering ions on the recovery of the analytes were investigated. At pH 5, the adsorption capacity of the nanometer TiO2-DZ was found to be 5.8 mg g−1 and 22.5 mg g−1 for Cr and Pb, respectively. According to the definition of IUPAC, the detection limits (3σ) of this method for Cr and Pb were 0.38 and 1.72 ng mL−1, respectively. The proposed method was applied to the determination of trace chromium and lead in foodstuffs, plants and water samples with satisfactory results.  相似文献   

18.
Katsumata H  Fujii A  Kaneco S  Suzuki T  Ohta K 《Talanta》2005,65(1):129-134
A sensitive and selective batch adsorption method is proposed for the preconcentration and determination of simazine. Simazine was preconcentrated on diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recovery of the analyte were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100 mL of validation solution containing 1.5 μg of simazine and 5 mL of ethanol as an eluent. Recovery of simazine was 89.0 ± 1.6% with a relative standard deviation for seven determinations of 1.5% under optimum conditions. The maximum preconcentration factor was 100 for simazine when 500 mL of sample solution volume was used. The linear range of calibration curve was 1-200 ng mL−1 with a correlation coefficient of 0.996 and the detection limit (3S/N) was 0.3 ng mL−1. The capacity of the adsorbent was also examined and found to be 1.1 mg g−1 for simazine. The proposed method was successfully applied to the determination of simazine in river water with high precision and accuracy.  相似文献   

19.
The potential of multiwalled carbon nanotubes (MWNTs) as solid-phase extraction adsorbent for the separation and preconcentration of gold has been investigated. Gold could be adsorbed quantitatively on MWNTs in the pH range of 1–6, and then eluted completely with 2 mL of 3% thiourea in 1 mol L− 1 HCl solution at a flow rate of 0.5 mL min− 1. A new method using a microcolumn packed with MWNTs as sorbent has been developed for the preconcentration of trace amount of Au prior to its determination by flame atomic absorption spectrometry. Parameters influencing the preconcentration of Au, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been examined and optimized. Under the optimum experimental conditions, the detection limit of this method for Au was 0.15 µg L− 1 with an enrichment factor of 75, and the relative standard deviation (R.S.D) was 3.1% at the 100 µg L− 1 Au level. The method has been applied for the determination of trace amount of Au in geological and water samples with satisfactory results.  相似文献   

20.
Yanyan Lu  Zhi Xing  Po Cao  Xinrong Zhang 《Talanta》2009,78(3):869-1801
A sandwich-type immunoassay linked with inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the detection of anti-erythropoietin antibodies (anti-EPO Abs). Recombinant human erythropoietin (rhEPO) was immobilized on the solid phase to capture anti-rhEPO Abs specifically. After the immunoreactions with Au-labeled goat-anti-rabbit IgG, a diluted HNO3 (2%) was used to dissociate Au nanoparticles which was then introduced to the ICP-MS for measurements. Under the optimized conditions, the calibration graph for anti-EPO Abs was linear in the range of 35.6-500 ng mL−1 with a detection limit of 10.7 ng mL−1 (3σ, n = 9). The relative standard deviation (R.S.D.) for three replicate measurements of 30.9 ng mL−1 of anti-EPO Abs was 8.43%. The recoveries of anti-EPO Abs in sera at the spiking level of 50, 100, 150, 200 and 400 ng mL−1 were 99.2%, 101.5%, 95.0%, 94.0% and 102.9%, respectively. For the real sample analysis, 26 samples from healthy people and 53 samples from patients with rhEPO treatments were studied. One sample from patients showed significantly higher anti-EPO Abs from other samples, indicating a possibility of immune response of this patient.  相似文献   