首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An improved competitive indirect immunoassay for the detection of 2,4,6-trichlorophenol (2,4,6-TCP) has been developed and optimized by preparing heterologous haptens that have been evaluated as coating antigens. The relation between the degree of heterology and immunoassay detectability has been investigated according to the geometric and electronic distribution similarities between the haptens and the analyte using molecular modeling tools. The assay has been characterized according to different physicochemical parameters such as the incubation time, the ionic strength, the effect of detergents and the pH. The resulting assay has an IC50 of 1.44 μg l−1 and a limit of detection (LOD) of 0.2 μg l−1 and it shows a good accuracy and suitability to analyze trichlorophenol in drinking water.  相似文献   

2.
The incorporation of melamine into food products is banned but its misuse has been widely reported in both animal feeds and food. The development of a rapid screening immunoassay for monitoring of the substance is an urgent requirement. Two haptens of melamine were synthesized by introducing spacer arms of different lengths and structures on the triazine ring of the analyte molecular structure. 6-Aminocaproic acid and 3-mercaptopropionic acid were reacted with 2-chloro-4,6-diamino-1,3,5-triazine (CAAT) to produce hapten 1 [3-(4,6-diamino-1,6-dihydro-1,3,5-triazin-2-ylamino) hexanoic acid] and hapten 2 [3-(4,6-diamino-1,6-dihydro-1,3,5-triazin-2-ylthio) propanoic acid], respectively. The molecular structures of the two haptens were identified by 1H nuclear magnetic resonance spectrometry, mass spectrometry and infrared spectrometry. An immunogen was prepared by coupling hapten 1 to bovine serum albumin (BSA). Two plate coating antigens were prepared by coupling both haptens to egg ovalbumin (OVA). A competitive indirect enzyme-linked immunosorbent assay (ciELISA) was developed to evaluate homogeneous and heterogeneous assay formats. The results showed that polyclonal antibodies with high titers were obtained, and the heterogeneous immunoassay format demonstrated a better performance with an IC50 of 70.6 ng mL−1, a LOD of 2.6 ng mL−1 and a LOQ of 7.6 ng mL−1. Except for cyromazine, no obvious cross-reactivity to common compounds was found. The data showed that the hapten synthesis was successful and the resultant antisera could be used in an immunoassay for the rapid and sensitive detection of this banned chemical.  相似文献   

3.
Three immunoassay systems: indirect, direct competitive enzyme-linked immunosorbent assay (IC-ELISA and DC-ELISA), fluorescence polarization immunoassay (FPIA) based on monoclonal antibodies for the detection of parathion-methyl (PM) were developed and optimized. Several PM derivatives (haptens) were conjugated to proteins and fluoresceinthiocarbamyl ethylenediamine (EDF) to obtain immunogens and competitors. The influence of immunogen and competitor structures on the assay performance was investigated. IC-ELISA was the most sensitive of all techniques developed, with a detection limit of 0.08 ng ml−1, but assay time was the longest (3.5 h per 96-well microtitre plate). DC-ELISA was easier to perform and quicker (1.5 h per 96-well microtitre plate) but less sensitive than IC-ELISA (detection limit was 0.5 ng ml−1). FPIA was the fastest and simplest (7 min per 10 samples) but the least sensitive (detection limit was 15 ng ml−1) technique. The methods were characterized by high specificity and reproducibility. The cross-reactivity for parathion-ethyl was around 30-40% for IC-ELISA and FPIA, but significantly higher (125%) for DC-ELISA. The immunoassays were applied to the analysis of PM residues in different food and environmental matrices. Methanol extracts of vegetable, fruit and soil samples were used for the analysis. Recoveries for most spiked samples averaged between 85 and 110%. The methods developed can be used for screening of food and environmental samples for PM residues without complicated clean-up.  相似文献   

4.
This study aimed at developing competitive enzyme-linked immunosorbent assays (ELISAs) for the organophosphorus (OP) insecticide fenitrothion using a monoclonal antibody. The hapten used to obtain the antibody had an ideal structural feature that allowed minimal functional group sacrifice. By using the antibody and a coating antigen, a competitive indirect ELISA was developed, which showed an IC50 of 14 ng mL−1 with a detection limit of 3.0 ng mL−1. A competitive direct ELISA using an enzyme tracer was also developed, which showed an IC50 of 17 ng mL−1 with a detection limit of 1.6 ng mL−1. The antibodies in both assays showed negligible cross-reactivity with the metabolites of fenitrothion and other OP pesticides except with the insecticides parathion-methyl and parathion-ethyl. Recoveries of fenitrothion from fortified rice and lettuce samples were determined and the bias in the recovery values was rationalized by using the standard curves obtained in the matrix extract.  相似文献   

5.
Zhang Q  Wu Y  Wang L  Hu B  Li P  Liu F 《Analytica chimica acta》2008,625(1):87-94
Five different haptens of the N-methylcarbamate insecticide metolcarb were designed and synthesized. All of the haptens were conjugated with ovalbumin (OVA) for the coating antigen, and one hapten containing all of the structure of metolcarb was conjugated with bovine serum albumin (BSA) for the immunogen. Two polyclonal antisera were raised against the BSA conjugate, and ten antibody/coating conjugate combinations were selected for studies of assay sensitivity and specificity for metolcarb. A class-specific combination was found, with the I50 of the assay ranged from 0.64 to 20.98 μg mL−1 for seven tested N-methylcarbamate insecticides except for pirimicarb. Considering titer, I50 and cross-reactivity of all combinations of antibody/coating conjugate, a competitive indirect enzyme-linked immunosorbent assay (ELISA) in a homologous system, whose limit of detection (LoD) reached 1.4 ng mL−1, was presented. The results of competitive ELISAs indicated that coating hapten structure can significantly affect not only assay sensitivity but also its specificity.  相似文献   

6.
Six polyclonal antisera to chloramphenicol (CAP) were successfully raised in camels, donkeys and goats. As a comparison of sensitivity, IC50 values ranged from 0.3 ng mL−1 to 5.5 ng mL−1 by enzyme-linked immunosorbent assay (ELISA) and from 0.7 ng mL−1 to 1.7 ng mL−1 by biosensor assay. The introduction of bovine milk extract improved the sensitivity of four of the antisera by ELISA and two by biosensor assay; a reduction in sensitivity of the remaining antisera ranged by a factor of 1.1-2.6. Porcine kidney extract reduced the sensitivity of all the antisera by a factor ranging from 1.1 to 7 by ELISA and a factor of 1.5 to 4 by biosensor. A low cross-reactivity with thiamphenicol (TAP) and florfenicol (FF) was displayed by antiserum G2 (1.2% and 18%, respectively) when a homologous ELISA assay format was employed. No cross-reactivity was displayed by any of the antisera when a homologous biosensor assay format was employed. Switching to a heterologous ELISA format prompted three of the antisera to display more significant cross-reactivity with TAP and FF (53% and 82%, respectively, using D1). The heterologous biosensor assay also increased the cross-reactivity of D1 for TAP and FF (56% and 129%, respectively) and of one other antiserum (G1) to a lesser degree. However, unlike the ELISA, the heterologous biosensor assay produced a substantial reduction in sensitivity (by a factor of 6 for D1).  相似文献   

7.
It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional strip assay for small molecule, the NSI-strip assay was also based on the competitive theory, difference was that the analyte competed three times with the capture reagent for the limited number of antibody binding sites. After the assay, the number of TLs developed in the test zone was inversely proportional to the analyte concentration, thus analyte content levels could be determined by observing the appeared number of TLs. Taking aflatoxin B1 as the model analyte, visual detection limit of the NSI-strip was 0.06 ng mL−1 and threshold concentrations for TL-I–III were 0.125, 0.5, and 2.0 ng mL−1, respectively. Therefore, according to the appeared number of TLs, the following concentration ranges would be detectable by visual examination: 0–0.06 ng mL−1 (negative samples), and 0.06–0.125 ng mL−1, 0.125–0.5 ng mL−1, 0.5–2.0 ng mL−1 and >2.0 ng mL−1 (positive samples). That was to say, compared to traditional strips the NSI-strip could offer more parameter information of the target analyte content. In this way, the NSI-strip improved the qualitative presence/absence detection of traditional strips by measuring the content (range) of target analytes semiquantitatively.  相似文献   

8.
Polyclonal antibody (PAb) with broad-specificity for O,O-diethyl organophosphorus pesticides (OPs) against a generic hapten, 4-(diethoxyphosphorothioyloxy)benzoic acid, was produced. The obtained PAb showed high sensitivity to seven commonly used O,O-diethyl OPs in a competitive indirect enzyme-linked immunosorbent assay (ciELISA) using a heterologous coating antigen, 4-(3-(diethoxyphosphorothioyloxy)phenylamino)-4-oxobutanoic acid. The 50% inhibition value (IC50) was 348 ng mL−1 for parathion, 13 ng mL−1 for coumaphos, 22 ng mL−1 for quinalphos, 35 ng mL−1 for triazophos, 751 ng mL−1 for phorate, 850 ng mL−1 for dichlofenthion, and 1301 ng mL−1 for phoxim. The limit of detection (LOD) met the ideal detection criteria of all the seven OP residues. A quantitative structure-activity relationship (QSAR) model was constructed to study the mechanism of antibody recognition using multiple linear regression analysis. The results indicated that the frontier-orbital energies (energy of the highest occupied molecular orbital, EHOMO, and energy of the lowest unoccupied molecular orbital, ELUMO) and hydrophobicity (log of the octanol/water partition coefficient, log P) were mainly responsible for the antibody recognition. The linear equation was log(IC50) = −63.274EHOMO + 15.985ELUMO + 0.556 log P − 25.015, with a determination coefficient (r2) of 0.908.  相似文献   

9.
Zhang Q  Wang L  Ahn KC  Sun Q  Hu B  Wang J  Liu F 《Analytica chimica acta》2007,596(2):303-311
Five haptens with different spacer-arm attachment sites on the structure of the organophosphorus insecticide fenthion were designed and synthesized. All of the haptens were conjugated with ovalbumin (OVA) for the coating antigen, and three haptens containing all or most of the structure of fenthion were conjugated with bovine serum albumin (BSA) for the immunogen. Six polyclonal antisera were raised against the three BSA conjugates, and 30 antibody/coating conjugate combinations were selected for studies of assay sensitivity and specificity for fenthion. The study revealed the best combination with high sensitivity (I50 of 0.08 ng mL−1) and high assay specificity, which indicated that when structural difference between the analyte and an immunizing hapten is less than that between a coating hapten and the immunizing hapten, a high sensitive enzyme-linked immunosorbent assay (ELISA) in the heterologous system may stand a good chance to be developed. The immunity results showed that heterology in the hapten spacer-arm attachment site of the immunogen could achieve a remarkable improvement in the quantity, sensitivity, and/or specificity of antibody, and that the moiety of an analyte, which is the same as the moiety near/on the immunizing spacer-arm hapten attachment site, contributes greatly to the interaction of antibody and hapten.  相似文献   

10.
Liang Y  Liu XJ  Liu Y  Yu XY  Fan MT 《Analytica chimica acta》2008,615(2):174-183
A general and broad class-specific enzyme-linked immunosorbent assay was developed for the O,O-dimethyl organophosphorus pesticides, including malathion, dimethoate, phenthoate, phosmet, methidathion, fenitrothion, methyl parathion and fenthion. Three haptens with different spacer-arms were synthesized. The haptens were conjugated to bovine serum albumin (BSA) for immunogens and to ovalbumin (OVA) for coating antigens. Rabbits were immunized with the immunogens and six polyclonal antisera were produced and screened against each of the coating antigens using competitive indirect enzyme-linked immunosorbent assay for selecting the proper antiserum. The effect of hapten heterology on immunoassay sensitivity was also studied. The antibody-antigen combination with the most selectivity for malathion was further optimized and tested for tolerance to co-solvent, pH and ionic strength changes. The IC50 values, under optimum conditions, were estimated to be 30.1 μg L−1for malathion, 28.9 μg L−1 for dimethoate, 88.3 μg L−1 for phenthoate, 159.7 μg L−1 for phosmet, 191.7 μg L−1 for methidathion, 324.0 μg L−1 for fenitrothion, 483.9 μg L−1 for methyl parathion, and 788.9 μg L−1 for fenthion. Recoveries of malathion, dimethoate, phenthoate, phosmet and methidathion from fortified Chinese cabbage samples ranged between 77.1% and 104.7%. This assay can be used in monitoring studies for the multi-residue determination of O,O-dimethyl organophosphorus pesticides.  相似文献   

11.
Sulfasalazine is an antibiotic used in the treatment of inflammatory bowel diseases. For the assessment of sulfasalazine in several biological matrices, an Enzyme-Linked Immunosorbent Assay (ELISA) method based on polyclonal antibodies was developed and characterized.The immunoassay showed a high sensitivity (IC50 = 0.51 ng mL−1) and specificity, a detection limit of 0.02 ng mL−1 and a dynamic range of 0.06-3.75 ng mL−1 (80-20% inhibition). The immunoassay performed well when it was applied to spiked plasma samples (from 0.5 to 2.0 ng mL−1) previously cleaned up by protein precipitation with methanol. Recoveries ranged from 83 to 119%, with a mean value of 99% (CV = 13%).Since sulfasalazine remaining of a treatment reaches the systemic circulation in unchanged form, the immunoassay can be applied to the determination of this pharmaceutical in human plasma in order to facilitate the control of the patients through the application of personal doses.  相似文献   

12.
A multi-determinant artificial antigen was prepared by haptens of four pesticides (chlorpyrifos, triazophos, carbofuran and parathion methyl) conjugating to the carrier protein BSA in turn. Male New Zealand white rabbits were immunized with this multi-determinant immunogen to produce the polyclonal antibodies (PAbs), which can recognize the four pesticides. The PAbs displayed high level for each relative hapten-OVA conjugate, with the favorable titers of 4.49 × 104, 8.98 × 104, 2.24 × 104 and 1.86 × 104, for CHBu-OVA, THHe-OVA, BFNB-OVA and MP5-OVA, respectively. Characterization studies of the PcAbs showed that it has high affinity and specificity to the four relative pesticides. An indirect competitive ELISA was developed for multi-residue determination. The I50 value for the four pesticides was 0.290, 0.065, 0.582 and 2.824 μg mL−1, with the detection limit (I10) of 0.022, 0.005, 0.015 and 0.115 μg mL−1 for carbofuran, triazophos, chlorpyrifos and parathion methyl, respectively. The linear rang was 0.016-2.000, 0.005-0.500, 0.010-2.000 and 0.063-5.000 μg mL−1, respectively, for carbofuran, triazophos, chlorpyrifos and parathion methyl. Results indicated that, this study provided a new strategy to develop immunoassays through artificial antigen design for pesticides multi-residue determination.  相似文献   

13.
Liu R  Xing Z  Lv Y  Zhang S  Zhang X 《Talanta》2010,83(1):48-54
A sensitive sandwich type immunoassay has been proposed with the detection by inductively coupled plasma mass spectrometry (ICP-MS) in a single particle mode (time resolved analysis). The signal induced by the flash of ions (197Au+) due to the ionization of single Au-nanoparticle (Au-NP) label in the plasma torch can be measured by the mass spectrometer. The frequency of the transient signals is proportional to the concentration of Au-NPs labels. Characteristics of the signals obtained from Au-NPs of 20, 45 and 80 nm in diameters were discussed. The analytical figures for the determination of Au-labeled IgG using ICP-MS in conventional integral mode and single particle mode were compared in detail. Rabbit-anti-human IgG was used as a model analyte in the sandwich immunoassay. A detection limit (3σ) of 0.1 ng mL−1 was obtained for rabbit-anti-human IgG after immunoreactions, with a linear range of 0.3-10 ng mL−1 and a RSD of 8.1% (2.0 ng mL−1). Finally, the proposed method was successfully applied to spiked rabbit-anti-human IgG samples and rabbit-anti-human serum samples. The method resulted to be a highly sensitive ICP-MS based sandwich type immunoassay.  相似文献   

14.
An ultrasensitive electrochemiluminescence (ECL) immunosensor based on CdSe quantum dots (QDs) has been designed for the detection of clenbuterol. The immunosensor was fabricated by layer by layer and characterized with atomic force microscopic images (AFM) and electrochemical impedance spectra (EIS). In oxygen-saturated pH = 9.0 Tris-HCl buffer, a strong ECL emission of QDs could be observed during the cathodic process due to the H2O2 product from electrochemical reduction of dissolved oxygen. Upon the formation of immunocomplex, the second antibody labeled with horseradish peroxidase was simply immobilized on the electrode surface. The ECL emission decreased since steric hindrance of the immunocomplex slowed down the electron-transfer speed of dissolved oxygen, and also could be greatly amplified by an enzymatic cycle to consume the self-produced coreactant. Using clenbuterol as model analyte, the ECL intensity was determined by the concentration of competitive immunoassay of clenbuterol with a wide calibration in the range of 0.05 ng mL−1 to 1000 ng mL−1, and a low detection limit was 0.02 ng mL−1. The immunosensor shows good stability and fabrication reproducibility. It was applied to detecting practical samples with the satisfactory results. This immunosensing strategy opens a new avenue for detection of residue and application of QDs in ECL biosensing.  相似文献   

15.
The paper reports a highly sensitive enzyme free electrochemical immunoassay (EFEIA) for the detection of herbicide chlorsulfuron. The assay is based upon oxidative gold nanoparticle (GNP) dissolution in an acidic solution. The consequent release of large amounts of gold (Au) metal ions after dissolution of gold nanoparticles tagged to antibody leads to the development of sensitive stripping voltammetry based immunoassay. The detection is made possible by the reduction of Au3 + ions at the screen printed electrode surface followed by metal analysis by using the square wave voltammetry technique. The sensitivity of chlorsulfuron detection by competitive assay procedure was 6.7 pg mL− 1 for EFEIA in marked contrast to optical detection using Standard ELISA procedure that gives a sensitivity of 4.97 ng mL− 1.  相似文献   

16.
Monoclonal antibodies against the hop-derived prenylated chalcone xanthohumol (X) and the prenylated flavonoids isoxanthohumol (IX) and 8-prenylnaringenin (8-PN) were developed. Carboxylic acid haptens of X, IX and 8-PN were synthesized by linking a spacer to their C4′-OH group followed by subsequent coupling to bovine serum albumin (BSA) to form conjugates that were employed as immunogens in BALB/c mice to raise antibodies. The monoclonal antibodies that were secreted from the established hybridoma cell lines proved, in cross-reactivity studies, to possess highly specific binding capacities in an optimized competitive indirect ELISA. The immunoassays make use of immunogen-coated microtiterplates and a peroxidase-labeled anti-mouse IgG1 secondary antibody with ABTS as a chromogenic substrate. For X the IC50 value derived from the standard curve was 62.91 ng mL−1, and for both IX and 8-PN 37.15 ng mL−1. The assay was validated for the quantitative analysis of X, IX and 8-PN in urine and serum. A simple sample pretreatment procedure using a diethyl ether extraction was optimized and the recoveries and matrix effects were assessed. The validity of the established assay was tested and mean inter- and intra-assay variations in urine were 2.32% and 1.91%, respectively for X, 6.24% and 2.39%, respectively for IX and 7.18% and 0.74%, respectively for 8-PN. In serum, the mean inter- and intra-assay variations were 8.90% and 1.37%, respectively for X, 6.13% and 1.57%, respectively for IX and 6.13% and 2.43%, respectively for 8-PN. Furthermore, the method demonstrated excellent accuracy and significant correlation with measurements by an established and validated HPLC-MS method.  相似文献   

17.
The use of Sudan I as an additive in food products has been prohibited in the European Union and many other countries. In this study, a highly sensitive and specific monoclonal antibody (mAb)-based indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of Sudan I in food samples was developed. The hapten derivative with a three-carbon-atom length of carboxylic spacer at the azobound para-position was synthesized and coupled to carrier proteins. The hapten-bovine serum albumin (BSA) conjugate was used as an immunogen, while the hapten-ovalbumin (OVA) conjugate was applied as a coating antigen. The mAb against Sudan I was produced by hybridoma technique and the corresponding ELISA was characterized in terms of sensitivity, specificity, precision and accuracy. At optimal experimental conditions, the standard curve was constructed in concentrations of 0.1-100 ng mL−1. The values of IC50 for nine standard curves were in the range of 1.1-2.0 ng mL−1 and the LOD at a signal-to-noise ratio of 3 (S/N = 3) was 0.07-0.14 ng mL−1. The cross-reactivity values of the mAb with Sudan II, III and IV were 9.5%, 33.9% and 0.95%; no cross-reactivity was found with other six edible colorants: Lemon yellow, Bright blue, Indigotin, Kermes, Amarant and Sunset yellow, indicating the assay displays not only high sensitivity but also high specificity as well. The organic solvent effect on the assay was tested. It was observed that the ELISA was tolerated to 30% of methanol and 10% of acetonitrile without significant loss of IC50 value. Six food samples were spiked with Sudan I and the methanolic extracts after appropriate dilution were analyzed by ELISA. Acceptable recovery rates of 88.2-110.5% and coefficients of variation of 2.5-17.4% were obtained. The ELISA for nine spiked samples was confirmed by high-performance liquid chromatography (HPLC) with a high correlation coefficient of 0.9840 (n = 9). The mAb-based ELISA proven to be a feasible quantitative/screening method for Sudan I analysis in food samples with the properties of high sensitivity, specificity, simplicity of sample pretreatment, high sample throughput and low expense.  相似文献   

18.
The study details the development of a fully validated, rapid and portable sensor based method for the on-site analysis of microcystins in freshwater samples. The process employs a novel lysis method for the mechanical lysis of cyanobacterial cells, with glass beads and a handheld frother in only 10 min. The assay utilises an innovative planar waveguide device that, via an evanescent wave excites fluorescent probes, for amplification of signal in a competitive immunoassay, using an anti-microcystin monoclonal with cross-reactivity against the most common, and toxic variants. Validation of the assay showed the limit of detection (LOD) to be 0.78 ng mL−1 and the CCβ to be 1 ng mL−1. Robustness of the assay was demonstrated by intra- and inter-assay testing. Intra-assay analysis had % C.V.s between 8 and 26% and recoveries between 73 and 101%, with inter-assay analysis demonstrating % C.V.s between 5 and 14% and recoveries between 78 and 91%. Comparison with LC–MS/MS showed a high correlation (R2 = 0.9954) between the calculated concentrations of 5 different Microcystis aeruginosa cultures for total microcystin content. Total microcystin content was ascertained by the individual measurement of free and cell-bound microcystins. Free microcystins can be measured to 1 ng mL−1, and with a 10-fold concentration step in the intracellular microcystin protocol (which brings the sample within the range of the calibration curve), intracellular pools may be determined to 0.1 ng mL−1. This allows the determination of microcystins at and below the World Health Organisation (WHO) guideline value of 1 μg L−1. This sensor represents a major advancement in portable analysis capabilities and has the potential for numerous other applications.  相似文献   

19.
A simple and rapid method based on solid-phase micro extraction (SPME) technique followed by gas chromatography-mass spectrometry with selected ion monitoring (GC-MS, SIM) was developed by the simultaneous determination of 16 pesticides of seven different chemical groups [Six organophosphorus (trichlorfon, diazinon, methyl parathion, malathion, fenthion and ethyon), three pyrethroids (bifenhin, permethrin, cypermethrin), two imidazoles (imazalil and prochloraz), two strobilurins (azoxystrobin and pyraclostrobin), one carbamate (carbofuran), one tetrazine (clofentezine), and one triazole (difenoconazole)] in water. The pesticides extraction was done with direct immersion mode (DI-SPME) of the polyacrilate fiber (PA 85 µm). The extraction temperature was adjusted to 50 °C during 30 min, while stirring at 250 rpm was applied. After extraction, the fiber was introduced in the GC injector for thermal desorption for 5 min. at 280 °C. The method was validated using ultra pure water samples fortified with pesticides at different concentration levels and shows good linearity in the concentrations between 0.05 and 250.00 ng mL− 1. The LOD and LOQ ranged, from 0.02 to 0.30 ng mL− 1 and 0.05 to 1.00 ng mL− 1, respectively. Intra-day and inter-day precisions were determined in two concentration levels (5.00 and 50.00 ng mL− 1). Intra-day relative standard deviation (%R.S.D.) ranged between 3.6 and 13.6%, and inter-day (%R.S.D.) ranged between 6.3 and 18.5%. Relative recovery tests were carried out spiking the ultra pure sample with standards in three different concentration levels 0.20, 5.00 and 50.00 ng mL− 1. The recovery at 0.20 ng mL− 1 level varied from 86.4 ± 9.4% to 108.5 ± 10.5%, at 5.00 ng mL− 1 level varied from 77.5 ± 10.8% to 104.6 ± 9.6% and at 50.00 ng mL− 1 level varied from 70.2 ± 4.6% to 98.4 ± 8.5%. The proposed SPME method was applied in twenty-six water samples collected in the “Platô de Neópolis”, State of Sergipe, Brazil. Methyl parathion was detected in five samples with an average concentration of 0.17 ng mL− 1 and bifenthrin, pyraclostrobin and azoxystrobin residues were found in three samples with average concentrations of 2.28, 3.12 and 0.15 ng mL− 1, respectively.  相似文献   

20.
A set of haptens has been synthesized in order to raise generic polyclonal antibodies against sulfonamides using different strategies. After the screening of all the immunorreagents, a highly sensitive enzyme-linked immunosorbent assay was set-up for simultaneous determination of six of these antibiotics.The developed procedure allows the screening of: sulfathiazole, sulfamethoxypyridazine, sulfapyridine, sulfamethizole, sulfasalazine and N4-phtalylsulfathiazole with good accuracy and precision at level 0.13 ng mL−1 in buffer.The suitability of developed ELISA for its application to honey analysis has been investigated. The antimicrobials were extracted from samples with acetate buffer, and cleaned up by solid phase extraction. The mean recovery found for honey samples, spiked from 1.5 to 4.5 ng mL−1 equivalents of sulfathiazole (24-72 μg sulfathiazole kg−1 honey), was 106%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号