首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
We developed an analytical method for measuring compound-specific stable carbon isotope ratios (δ13C) of phenols and nitrophenols in filter samples of particulate organic matter. The method was tested on 13 phenols derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA), together with four nonphenolic compounds. The data obtained by our method required two specific corrections for the determination of valid δ13C values: (1) for nitro compounds, the routine correction with use of m/z 46 for the contribution of 12C17O16O molecules) to m/z 45 was modified due to impact of NO2 on the m/z 46 trace, and (2) for the derivatized phenols, measured δ13C values were corrected for the shift in δ13C due to the addition of carbon atoms from the BSTFA moiety. Analysis of standard-spiked filters showed that overall there was a small compound-dependent bias in the δ13C values: the average bias ± the standard error of the mean of −0.21 ± 0.1‰ for the standard compounds tested, except 3-methylcatechol, methylhydroquinone, 4-methyl-2-nitrophenol, and 2,6-dimethyl-4-nitrophenol, whereas the average biases ± the standard errors of the mean for those were +1.2 ± 0.3‰, +1.2 ± 0.2‰, −1.2 ± 0.2‰, and −1.4 ± 0.5‰, respectively, when the injected mass of a derivatized compound exceeded 15 ngC. In situations where such small biases and uncertainties are acceptable, the method described here could be used to obtain valuable information about δ13C values. We also analyzed a real filter sample to demonstrate the practical applicability of the method.  相似文献   

2.
In the present paper we describe a robust and simple method to measure dissolved iron (DFe) concentrations in seawater down to <0.1 nmol L−1 level, by isotope dilution multiple collector inductively coupled plasma mass spectrometry (ID-MC-ICP-MS) using a 54Fe spike and measuring the 57Fe/54Fe ratio. The method provides for a pre-concentration step (100:1) by micro-columns filled with the resin NTA Superflow of 50 mL seawater samples acidified to pH 1.9. NTA Superflow is demonstrated to quantitatively extract Fe from acidified seawater samples at this pH. Blanks are kept low (grand mean 0.045 ± 0.020 nmol L−1, n = 21, 3× S.D. limit of detection per session 0.020–0.069 nmol L−1 range), as no buffer is required to adjust the sample pH for optimal extraction, and no other reagents are needed than ultrapure nitric acid, 12 mM H2O2, and acidified (pH 1.9) ultra-high purity (UHP) water. We measured SAFe (sampling and analysis of Fe) reference seawater samples Surface-1 (0.097 ± 0.043 nmol L−1) and Deep-2 (0.91 ± 0.17 nmol L−1) and obtained results that were in excellent agreement with their DFe consensus values: 0.118 ± 0.028 nmol L−1 (n = 7) for Surface-1 and 0.932 ± 0.059 nmol L−1 (n = 9) for Deep-2. We also present a vertical DFe profile from the western Weddell Sea collected during the Ice Station Polarstern (ISPOL) ice drift experiment (ANT XXII-2, RV Polarstern) in November 2004–January 2005. The profile shows near-surface DFe concentrations of 0.6 nmol L−1 and bottom water enrichment up to 23 nmol L−1 DFe.  相似文献   

3.
A fast, simple, and sensitive flow injection analysis method was developed for the measurement of semicarbazide-sensitive amine oxidase (SSAO) activity in human serum. Benzaldehyde, generated by the action of SSAO after incubation of serum with benzylamine, was derivatized with a novel aromatic aldehyde-specific reagent (1,2-diaminoanthraquinone) and the fluorescent product was measured by fluorescence detection at excitation and emission wavelengths of 390 and 570 nm, respectively. Serum SSAO activity was defined as benzaldehyde (nmol) formed per milliliter serum per hour. The method was linear over SSAO activity of 0.2–150.0 nmol mL−1 h−1 with a detection limit of 0.06 nmol mL−1 h−1. The %RSD of intra-day and inter-day precision did not exceed 9.4% and the accuracy ranged from −6.5 to −0.6%. The method was applied for the determination of the serum SSAO activity in healthy controls (C, n = 24) and diabetes mellitus patients (DM, n = 18). It was demonstrated that the activity (mean ± SE) of SSAO in diabetics sera was significantly higher than that in healthy subjects’ ones (DM; 73.3 ± 1.8 nmol mL−1 h−1vs C; 58.9 ± 2.2 nmol mL−1 h−1, P 0.01).  相似文献   

4.
A new method is described for a precise and simultaneous determination of the rate of production and dissolution of biosilica in marine waters, using isotopic dilution technique. No HF or F2 is required for chemical preparations as the change in isotopic composition is measured on silica producing SiO2 ions. The seawater sample flask is spiked with 30Si(OH)4 (<10% of increase in situ concentration) and incubated in in situ conditions. At the end of incubation, changes of the 30Si:28Si ratios in particulate and liquid phases are measured by using a thermal ionisation mass spectrometer Finnigan THQ. The relative analytical precision of the isotopic ratio measurements is <0.5%. The limit of detection of the change in isotopic ratio during incubation is 0.02 atom%. The overall repeatability determined on eight subsamples (average production: 0.23 μM day−1; average dissolution: 0.07 μM day−1) is ±0.02 and ±0.01 μM day−1 for production and dissolution, respectively. Using mass and isotopic balances of the particulate and dissolved phases in the incubation flask, the best estimates for production and dissolution rates are calculated iteratively. This method was applied to 112 samples of marine waters (production, range: 0.00-2.38 μM day−1; dissolution, range: 0.00-1.18 μM day−1).  相似文献   

5.
Copper is an essential trace metal that shows a vertical recycled-scavenged profile in the ocean. To help elucidate the biogeochemical cycling of Cu in the present and past oceans, it is important to determine the distribution of Cu isotopes in seawater. However, precise isotopic analysis of Cu has been impaired by the low concentrations of Cu as well as co-existing elements that interfere with measurements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The objective of this study is to develop a simple Cu pre-concentration method using Nobias-chelate PA1 resin (Hitachi High Technologies). This extraction followed by anion exchange, allows precise analysis of the Cu isotopic composition in seawater. Using this method, Cu was quantitatively concentrated from seawater and >99.9999% of the alkali and alkaline earth metals were removed. The technique has a low procedural blank of 0.70 ng for Cu for a 2 L sample and the precision of the Cu isotopic analysis was ±0.07‰ (±2SD, n = 6). We applied this method to seawater reference materials (i.e., CASS-5 and NASS-6) and seawater samples obtained from the northwestern Pacific Ocean. The range of dissolved δ65Cu was 0.40–0.68‰.  相似文献   

6.
The study of Fe, Zn and Cd stable isotopes (δ56Fe, δ66Zn and δ114Cd) in seawater is a new field, which promises to elucidate the marine cycling of these bioactive trace metals. However, the analytical challenges posed by the low concentration of these metals in seawater has meant that previous studies have typically required large sample volumes, highly limiting data collection in the oceans. Here, we present the first simultaneous method for the determination of these three isotope systems in seawater, using Nobias PA-1 chelating resin to extract metals from seawater, purification by anion exchange chromatography, and analysis by double spike MC-ICPMS. This method is designed for use on only a single litre of seawater and has blanks of 0.3, 0.06 and <0.03 ng for Fe, Zn and Cd respectively, representing a 1–20 fold reduction in sample size and a 4–130 decrease in blank compared to previously reported methods. The procedure yields data with high precision for all three elements (typically 0.02–0.2‰; 1σ internal precision), allowing us to distinguish natural variability in the oceans, which spans 1–3‰ for all three isotope systems. Simultaneous extraction and purification of three metals makes this method ideal for high-resolution, large-scale endeavours such as the GEOTRACES program.  相似文献   

7.
The present work describes the development of an amperometric sensor based on hemin immobilized on a titanium oxide modified silica toward detection of artemisinin (ARN) in neutral medium at an applied potential of −0.5 V vs. Ag/AgCl. The sensor presented its best performance in 0.1 mol L−1 phosphate buffer solution, at pH 7.0. After optimizing the operational conditions, the sensor provided a linear response range for ARN reduction from 50 nmol L−1 to 1000 nmol L−1 with a sensitivity, detection and quantification limits of 24.66 A L mol−1, 15 nmol L−1 and 52 nmol L−1, respectively. The proposed sensor showed a stable response for at least 80 successive determinations. The repeatability of the measurements with the sensor and the preparation of a series of electrodes, evaluated in terms of relative standard deviation, were 4.1% and 5.0%, respectively, for n = 10. The developed sensor was applied for the determination of ARN in the crude extracts of A. vulgaris L and the average recovery for these samples is 101.4 (± 3.1)%.  相似文献   

8.
Yasri NG  Halabi AJ  Istamboulie G  Noguer T 《Talanta》2011,85(5):2528-2533
A new simple chronoamperometry methodology was developed for the ultrasensitive determination of lead ions using a PEDOT:PSS coated graphite carbon electrode. The polymer was directly coated on a graphite carbon electrode and characterized using simple cycle voltammetric measurements. The presence of lead ions induced a cathodic peak starting at −550 ± 10 mV vs. Ag/AgCl, and an anodic peak starting at −360 ± 10 mV vs. Ag/AgCl. Electroaccumulation of lead ions onto the PEDOT:PSS modified electrode was performed at −650 mV vs. Ag/AgCl for 30 s in a pH 2.2 hydrochloric acid solution. Chronoamperometry measurements were carried out at −350 mV vs. Ag/AgCl allowing the oxidation of accumulated lead. Using this method, lead ions were detected for concentrations ranging between 2.0 nmol L−1 and 0.1 μmol L−1 (R2 = 0.999). The detection limit was calculated to be 0.19 nmol L−1 and the quantification limit of 0.63 nmol L−1. The method was shown to be highly precise and sensitive, negligible interference was detected from other metal ions. The proposed method was successfully applied for the detection of lead ions in vegetables.  相似文献   

9.
A cryogenic separation method of chloromethane (CH3Cl) from methyl iodide (CH3I) for δ37Cl measurement with isotope ratio mass spectrometer is described. A cold trap with sealed 2,2,4-trimethylpentane (TMP) as the cryogen is used in this method. CH3Cl can be separated from CH3I at the TMP melting point (−107 °C) based on the difference in the vapor pressure between CH3Cl (322.6 Pa) and CH3I (lower than 1.3 Pa) at −107 °C. After two-step separation processes, the yields of CH3Cl purified from CH3Cl-CH3I mixture are 96-101%, and the difference between the δ37Cloriginal and δ37ClAfter separation is from −0.06 to +0.06‰ (0.01 ± 0.04‰). These results suggest that CH3Cl is completely separated from CH3I with no change of δ37Cl value. This method using the cold trap with sealed TMP is very safe and not harmful, because the liquid organic compound used as the cryogen is contained in the trap and does not evaporate during the separation procedure. This method is also simple and inexpensive relative to the method using a gas chromatograph.  相似文献   

10.
High quality free-standing polyfluorene (PFe) films were synthesized electrochemically by direct anodic oxidation of fluorene in pure boron trifluoride diethyl etherate (BFEE) on stainless steel sheet. The oxidation potential of fluorene in this medium was measured to be only 1.1 V versus SCE, which was much lower than that determined in acetonitrile + 0.1 mol L−1 TBATFB. PFe films obtained from this medium showed good electrochemical behavior, good thermal stability with conductivity of 0.25 S cm−1, indicating that BFEE is a better medium than acetonitrile for the electrosyntheses of PFe films. FTIR and 1H NMR spectral investigations indicated that the polymerization of fluorene occurred mainly at 2, 7 position. As-formed PFe films can be partly dissolved in acetone, acetonitrile, tetrahydrofuran, etc.  相似文献   

11.
Matsumiya H  Iki N  Miyano S 《Talanta》2004,62(2):337-342
Sulfonylcalix[4]arenetetrasulfonate (SO2CAS) has been examined as a pre-column chelating reagent for ultratrace determination of metal ions by ion-pair reversed-phase high-performance liquid chromatography with spectrophotometric detection. Metal ions were converted into the SO2CAS chelates in an acetic buffer solution (pH 4.7). The chelates were injected onto a n-octadecylsilanized silica-type Chromolith™ Performance RP-18e column and were eluted using a methanol (50 wt.%)-water eluent (pH 5.6) containing tetra-n-butylammonium bromide (7.0 mmol kg−1), acetate buffer (5.0 mmol kg−1), and disodium ethylendiamine-N,N,N′,N′-tetraacetate (0.10 mmol kg−1). Under the conditions used, Al(III), Fe(III), and Ti(IV) were selectively detected among 21 kinds of metal ions [Al(III), Ba(II), Be(II), Ca(II), Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Ga(III), Hf(IV), In(III), Mg(II), Mn(II), Mo(VI), Ni(II), Pb(II), Ti(IV), V(V), Zn(II), and Zr(IV)]. The detection limits on a 3σ blank basis were 8.8 nmol dm−3 (0.24 ng cm−3) for Al(III), 7.6 nmol dm−3 (0.42 ng cm−3) for Fe(III), and 17 nmol dm−3 (0.80 ng cm−3) for Ti(IV). The practical applicability of the proposed method was checked using river and tap water samples.  相似文献   

12.
A sensor based on glassy carbon (GC) electrode modified with cobalt tetrasulfonated phthalocyanine (CoTSPc) and a poly-l-lysine (PLL) film is proposed for diospyrin determination in nanomolar concentrations with differential pulse voltammetry (DPV) technique. The modified electrode showed excellent catalytic activity presenting much higher peak currents than those measured on a bare GC electrode. Linear response range, sensitivity and limit of detection (LOD) were of 1-120 nmol l−1, 220.46 nA l nmol−1 cm−2 and 0.3 nmol l−1, respectively. The repeatability of the proposed sensor, evaluated in term of relative standard deviation (R.S.D.), was measured as 4.4% for 10 experiments in 50 μmol l−1 diospyrin samples. The developed sensor was applied for the determination of diospyrin in the crude extracts of the stem-bark of Diospyros montana Roxb. and the average recovery for these samples was 101.9 (±3.1)%.  相似文献   

13.
An international collaborative study of isotopic methods applied to control the authenticity of vinegar was organized in order to support the recognition of these procedures as official methods. The determination of the 2H/1H ratio of the methyl site of acetic acid by SNIF-NMR (site-specific natural isotopic fractionation-nuclear magnetic resonance) and the determination of the 13C/12C ratio, by IRMS (isotope ratio mass spectrometry) provide complementary information to characterize the botanical origin of acetic acid and to detect adulterations of vinegar using synthetic acetic acid. Both methods use the same initial steps to recover pure acetic acid from vinegar. In the case of wine vinegar, the determination of the 18O/16O ratio of water by IRMS allows to differentiate wine vinegar from vinegars made from dried grapes. The same set of vinegar samples was used to validate these three determinations.The precision parameters of the method for measuring δ13C (carbon isotopic deviation) were found to be similar to the values previously obtained for similar methods applied to wine ethanol or sugars extracted from fruit juices: the average repeatability (r) was 0.45 ‰, and the average reproducibility (R) was 0.91‰. As expected from previous in-house study of the uncertainties, the precision parameters of the method for measuring the 2H/1H ratio of the methyl site were found to be slightly higher than the values previously obtained for similar methods applied to wine ethanol or fermentation ethanol in fruit juices: the average repeatability was 1.34 ppm, and the average reproducibility was 1.62 ppm. This precision is still significantly smaller than the differences between various acetic acid sources (δ13C and δ18O) and allows a satisfactory discrimination of vinegar types. The precision parameters of the method for measuring δ18O were found to be similar to the values previously obtained for other methods applied to wine and fruit juices: the average repeatability was 0.15‰, and the average reproducibility was 0.59‰. The above values are proposed as repeatability and reproducibility limits in the current state of the art.On the basis of this satisfactory inter-laboratory precision and on the accuracy demonstrated by a spiking experiment, the authors recommend the adoption of the three isotopic determinations included in this study as official methods for controlling the authenticity of vinegar.  相似文献   

14.
The reduction of 4-nitrophenol (4-NP) has been carried out on a modified glassy carbon electrode using cyclic and differential pulse voltammetry (DPV). The sensor was prepared by modifying the electrode with lithium tetracyanoethylenide (LiTCNE) and poly-l-lysine (PLL) film. With this modified electrode 4-NP was reduced at −0.7 V versus SCE. The sensor presented better performance in 0.1 mol l−1 acetate buffer at pH 4.0. The other experimental parameters, such as concentration of LiTCNE and PLL, pulse amplitude and scan rate were optimized. Under optimized operational conditions, a linear response range from 27 up to 23200 nmol l−1 was obtained with a sensitivity of 3.057 nA l nmol−1 cm−2. The detection limit for 4-NP determination was 7.5 nmol l−1. The proposed sensor presented good repeatability, evaluated in term of relative standard deviation (R.S.D.=4.4%) for n=10 and was applied for 4-NP determination in water samples. The average recovery for these samples was 103.0 (± 0.7)%.  相似文献   

15.
Iron isotope fractionation between liquid and vapor iron pentacarbonyl was measured in a closed system at ∼0 and ∼21 °C to determine if Fe isotope analysis of iron pentacarbonyl vapor is viable using electron-impact, gas-source mass spectrometry. At the 2σ level, there is no significant Fe isotope fractionation between vapor and liquid under conditions thought to reflect equilibrium. Experiments at ∼0 °C indicate iron pentacarbonyl vapor is ∼0.05 per mil (‰) greater in 56Fe/54Fe than liquid iron pentacarbonyl, which is just resolvable at the 1σ level. Partial decomposition of iron pentacarbonyl vapor or liquid to an iron oxide or iron metal shows that significant isotopic fractionation occurs, where the decomposed product has a lower 56Fe/54Fe ratio as compared to the starting iron pentacarbonyl. It follows that methods to decompose iron pentacarbonyl must be quantitative to obtain accurate isotope values.  相似文献   

16.
Water-soluble l-cysteine-capped-CdS nanoparticles were prepared in aqueous solution at room temperature through a straightforward one-pot process by using safe and low-cost inorganic salts as precursors, and characterized by transmission electron microscopy, X-ray diffraction spectrometry, Fourier transform infrared spectrometry, spectrofluorometry and ultraviolet-visible spectrometry. The prepared l-cysteine-capped-CdS nanoparticles were evaluated as fluorescence probe for Hg(II) detection. The fluorescence quenching of the l-cysteine-capped-CdS nanoparticles depended on the concentration and pH of Hg(II) solution. Maximum fluorescence quenching was observed at pH 7.4 with the excitation and emission wavelengths of 360 nm and 495 nm, respectively. Quenching of its fluorescence due to Hg(II) at the 20 nmol l−1level was unaffected by the presence of 5 × 106-fold excesses of Na(I) and K(I), 5 × 105-fold excesses of Mg(II), 5 × 104-fold excesses of Ca(II), 500-fold excesses of Al(III), 91-fold excesses of Mn(II), 23.5-fold excesses of Pb(II), 25-fold excesses of Fe(III), 25-fold excesses of Ag(I), 8.5-fold excesses of Ni(II) and 5-fold excesses of Cu(II). Under optimal conditions, the quenched fluorescence intensity increased linearly with the concentration of Hg(II) ranging from 16 nmol l−1 to 112 nmol l−1. The limit of detection for Hg(II) was 2.4 nmol l−1. The developed method was applied to the detection of trace Hg(II) in aqueous solutions.  相似文献   

17.
Wei J  He JB  Cao SQ  Zhu YW  Wang Y  Hang GP 《Talanta》2010,83(1):190-196
A nonionic poly(2-amino-5-mercapto-thiadiazole) film was electrodeposited on a solid carbon paste electrode via a potential scanning procedure, and used for amperometric sensing of ascorbic acid (AA), dopamine (DA) and serotonin (ST). The highly electrocatalytic activity of the sensor to the three analytes was demonstrated from the sensitive and well separated voltammetric signals. The polymer film did not show significant accumulation effect on all the three species, reducing the fouling and deactivation of the electrode surface as well as the mutual interference among the analytes. The sensor achieved amperometric sensitivities of 1.92 nA (nmol L−1)−1 cm−2 to AA in the linear range of 0.025-1.95 μmol L−1, 3.76 nA (nmol L−1)−1 cm−2 to DA and 7.00 nA (nmol L−1)−1 cm−2 to ST both in the linear range of 0.02-1.56 μmol L−1. The lowest detection limits were found to be 1.5, 0.7 and 0.4 nmol L−1 for AA, DA and ST, respectively. This sensor was successfully employed for the successive determination of AA, DA and ST in pharmaceutical samples. The good antifouling property and reproducibility of the proposed sensor can be attributed to the nonionic polymer film without electrostatic attraction to the ionized species in the solutions.  相似文献   

18.
Potentiometric FIA titrations were performed to determine enzyme activities of lipase type B from Candida antarctica, CAL-B. Two substrates, triacetin and tributyrin were hydrolyzed in phosphate buffer solutions, and the concentration change of the base component of the buffer was titrated in a carrier solution containing hydrochloric acid and potassium chloride. The system was calibrated with butyric acid and acetic acid, respectively. FIA titration peaks were evaluated with respect to peak height and peak area. Butyric acid and acetic acid could be titrated in the buffer solution from 3 × 10−3 mol L−1 to 0.1 mol L−1. The detection limit of enzyme activity was determined to be 0.07 U mL−1 (15 min reaction time) and the minimum activity was calculated to be 0.035 units corresponding to 35 nmol min−1. The specific activities of lipase B for the hydrolysis of tributyrin and triacetin were determined as 16 ± 2 U mg−1 and 2 ± 0.2 U mg−1 (per mg commercial lipase preparation), respectively.  相似文献   

19.
Li J  Cai Z 《Talanta》2008,77(1):331-339
We demonstrated that anionic porphyrins could be stacked and separated in micellar electrokinetic chromatography (MEKC) and microemulsion electrokinetic chromatography (MEEKC) by applying acetonitrile and high salt content in human urine sample matrix. The introduction of sample containing acetonitrile and sodium chloride into the CE capillary at more than 10% of the total capillary volume resulted in the improvement of peak resolution and the enhancement of detection sensitivity. The achieved acetonitrile stacking enrichment factors of six porphyrins ranged from 12 to 32 in MEKC and from 28 to 33 in MEEKC, respectively. The stacking technique was successfully applied for analyzing porphyrins present in urine samples that were deproteinized with acetonitrile. For the analysis of coproporphyrin isomers, addition of the sodium cholate (SC) into micelle and microemulsion solutions provided adequate resolution. Calibration curves obtained for the determination of coproporphyrin isomers were found linear between 30 and 400 nmol L−1, and the limit of detection (LOD) was 20 nmol L−1 in MEEKC. Intra- and interday precisions (n = 11) in the microemulsion separation system for the isomers at spiked concentrations of 40-400 nmol L−1 in urine were in the range of 0.1-0.4% and 0.7-7.6% for migration time and peak area, respectively. Coproporphyrin III, coproporphyrin I and uroporphyrin were detected at levels of 80.7 nmol L−1, 32.3 nmol L−1 and 19.8 nmol L−1, respectively, in the urine samples collected from healthy individuals. Different porphyrin profiles, however, were observed in urine samples from porphyria cutanea tarda (PCT) patients.  相似文献   

20.
Here, we present a fast and simple hydrogen peroxide assay that is based on time-resolved fluorescence. The emission intensity of a complex consisting of terbium ions (Tb3+) and phthalic acid (PA) in HEPES buffer is quenched in the presence of H2O2 and this quenching is concentration-dependent. The novel PATb assay detects hydrogen peroxide at a pH range from 7.5 to 8.5 and with a detection limit of 150 nmol L−1 at pH 8.5. The total assay time is less than 1 min. The linear range of the assay can be adapted by a pH adjustment of the aqueous buffer and covers a concentration range from 310 nmol L−1 to 2.56 mmol L−1 in total which encompasses four orders of magnitude. The assay is compatible with high concentrations of all 47 tested inorganic and organic compounds. The PATb assay was applied to quantify H2O2 in polluted river water samples. In conclusion, this fast and easy-to-use assay detects H2O2 with high sensitivity and precision.  相似文献   