首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A procedure for the simultaneous kinetic spectrophotometric determination of cephalexin and trimethoprim was described. It was based on the different reaction rate of oxidation of these compounds with yellow ammonium cerous (Ⅳ) sulfate in acidic medium and colorless cerous (Ⅲ) sulfate was produced. The overlapped kinetic data was quantitatively resolved by the use of chemometric methods, partial least squares (PLS), principal component regression (PCR) and radial basis function-artificial neural network (RBF-ANN). The proposed method was also applied to the simultaneous determination of cephalexin and trimethoprim in pharmaceutical preparation and human urine with satisfied results, which compared well with those obtained by HPLC.  相似文献   

2.
Yongnian Ni  Yong Wang 《Talanta》2009,78(2):432-749
This paper describes a simple and sensitive kinetic spectrophotometric method for the simultaneous determination of Amaranth, Ponceau 4R, Sunset Yellow, Tartrazine and Brilliant Blue in mixtures with the aid of chemometrics. The method involved two coupled reactions, viz. the reduction of iron(III) by the analytes to iron(II) in sodium acetate/hydrochloric acid solution (pH 1.71) and the chromogenic reaction between iron(II) and hexacyanoferrate(III) ions to yield a Prussian blue peak at 760 nm. The spectral data were recorded over the 500-1000 nm wavelength range every 2 s for 600 s. The kinetic data were collected at 760 nm and 600 s, and linear calibration models were satisfactorily constructed for each of the dyes with detection limits in the range of 0.04-0.50 mg L−1. Multivariate calibration models for kinetic data were established and verified for methods such as the Iterative target transform factor analysis (ITTFA), principal component regression (PCR), partial least squares (PLS), and principal component-radial basis function-artificial neural network (PC-RBF-ANN) with and without wavelet packet transform (WPT) pre-treatment. The PC-RBF-ANN with WPT calibration performed somewhat better than others on the basis of the %RPET (∼9) and %Recovery parameters (∼108), although the effect of the WPT pre-treatment was marginal (∼0.5% RPET). The proposed method was applied for the simultaneous determination of the five colorants in foodstuff samples, and the results were comparable with those from a reference HPLC method.  相似文献   

3.
The determination of Al3+ in solution using a continuous-wave mode mismatched thermal lens spectrometer is reported and two spectrophotometric procedures are compared. The reagent investigated were bromopyrogallol red—tetradecyltrimethylammonium bromide (BPR—TDTA) and chrome azurol S—cetylpyridinium chloride (CAS—CPC). The CAS—CPC system gave a superior detection limit (0.17 μg 1?1) to the BPR—TDTA system (1.15 mg 1?1) owing to the higher reagent blanks and concomitant laser noise in the latter system.  相似文献   

4.
在邻二氮菲(Phen)、铬天青S(CAS)和十四烷基二甲基苄基氯化铵(TDMBA)的共同存在下,于pH 5~6的酸性介质中,铁、铝分别生成Fe-Phen和Al-CAS-TDMBA络合物,用同一份试液,在波长510 nm测定铁,在625 nm测定铝,两种络合物互不干扰。用该法可同时测定硅石中的铁和铝。  相似文献   

5.
A very simple and selective spectrophotometric method for simultaneous determination of iron(II), nickel(II) and cobalt(II) based on formation of their complexes with 1-(2-pyridylazo)-2-naphtol (PAN) in micellar media is described. Although the complexes of Fe(II), Ni(II) and Co(II) with reagent show a spectral overlap, they have been simultaneously determined by partial least squares (PLS) with and without preprocessing step using direct orthogonal signal correction (DOSC). The linear range was 0.30-4.50 μg ml−1 for Co(II), 0.20-3.00 μg ml−1 for Ni(II) and 0.30-5.00 μg ml−1 for Fe(II). The results obtained by the PLS and DOSC-PLS were statistically compared. Interference effects of common anions and cations were studied and the proposed method was also applied satisfactorily to the determination of Fe(II), Ni(II) and Co(II) in synthetic samples.  相似文献   

6.
The univariate and multivariate calibration methods were applied for the simultaneous determination of iodate and periodate in water. The method is based on the reaction of periodate and iodate with pyrogallol red in sulfuric acid media. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of pyrogallol red at 470 nm. The calibration curve was linear over the concentration ranges of 0.1-12 and 0.1-14 μg ml−1 for iodate and periodate, respectively. The experimental calibration matrix for partial least squares (PLS) and orthogonal signal correction (OSC-PLS) method was designed with 35 mixtures. The results obtained by the PLS and OSC-PLS were statistically compared. The effects of various cations and anions on iodate and periodate determination have been investigated.  相似文献   

7.
The H-point standard addition method (HPSAM), based on spectrophotometric measurements for simultaneous determination of beryllium and aluminium, is described. This method is based on the difference between their rates of reactions with Chrome Azurol S (CAS) in cetyltrimethylammonium bromide (CTAB) micellar media. The results showed that beryllium and aluminium could be determined simultaneously in the ranges of 10-200 and 10-300 ng mL(-1), respectively. Under working conditions, the proposed method was successfully applied to the simultaneous determination of beryllium and aluminium in environmental, geochemical and alloy samples.  相似文献   

8.
The voltammetric behaviour of three 5-nitroimidazoles,metronidazole,tinidazole and ornidazole,was investigated,and a method was developed for the simultaneous determination of these compounds,based on their reduction at a hanging mercury drop electrode(HMDE) in pH 8.95 buffer with differential pulse voltammetric(DPV) approach.Well defined voltammetric waves with peak potentials of -692,-640 and -652 mV were observed for these compounds,respectively.It is difficult to determine them individually from their mixtures without preseparation,for their voltammetric peaks overlapped seriously,so the chemometrics were used to resolve the overlapped voltammogram and quantify the mixtures.The proposed method was successfully applied to the determination of three 5-nitroimidazoles in milk and honey samples.  相似文献   

9.
Carbamazepine (CBZ) and phenytoin (PHT) are two antiepileptic drugs which are used simultaneously. In this paper a partial least-squares (PLS) calibration method is described for the simultaneous spectrophotometric determination of CBZ and PHT in plasma. Standard binary mixtures of CBZ and PHT have been resolved by application of PLS-1 to their UV spectra. Then, the binary standard solutions, spiked to plasma, were prepared and after the extraction of the drugs, their corresponding UV spectrum were analyzed by PLS regression to calculate the concentration of drugs in unknown plasma. A leave one out cross-validation procedure was employed to find the optimum numbers of latent variables using PRESS. A HPLC method was also applied for simultaneous determination of two drugs in the plasma and in methanol. The mean recoveries obtained by PLS were 98.4 and 98.2 for CBZ and PHT and those obtained by HPLC were 100.1 and 101.7, respectively. Although, the HPLC method showed better performance than PLS, it was found that the results obtained by PLS were comparable with those obtained by HPLC method.  相似文献   

10.
Secondary amines react with carbon disulphide to form stable dialkyldithiocarbamates at high pH in aqueous Triton X-100 solution. The formation rates of dimethyl-, diethyl-, di-n-propyl-, diisopropyl-, di-n-butyl- and diisobutyldithiocarbamates and pyrrolidinedithiocarbamate were measured by a stopped-flow spectrophotometric method. The reaction rates were a function of the pH of the solution and depended on the size and structure of the amines. The rate of isoalkylamines was far slower than that of the n-alkyl analogues. Individual concentrations of amines were determined in a mixture of di-n- and diisopropylamine and in a mixture of diiso- and di-n-butylamine.  相似文献   

11.
A kinetic method is presented for the simultaneous determination of iron(III) and manganese(II) based on the different reaction rates resulting from the catalytic effect of both metal ions on the oxidation of 2-hydroxybenzaldehyde thiosemicarbazone by hydrogen peroxide in an ammoniacal medium. The reaction is monitored spectrofluorimetrically at 440 nm and with excitation at 365 nm. Two sets of reaction conditions are established to maximize the effect of manganese compared to iron, and vice versa, and the data are evaluated from simultaneous equations. Mixtures of these metal ions at ng ml?1 levels for iron/manganese ratios from 8:1 to 1:2 can be determined with an accuracy and precition of about 3% and 1%, respectively. The methods has been applied successfully to the determination of both metals in aluminium and copper alloys, beer, cheeses and soils.  相似文献   

12.
In this work, direct determination of lorazepam, an anxiolytic and sedative agent, in pharmaceutical formulations and biological fluids (urine and human plasma) was accomplished based on ultraviolet spectrophotometry (260-380 nm) using parallel factor analysis (PARAFAC) and partial least squares (PLS). The study was carried out in the pH range from 1.0 to 12.0 and with a concentration range from 0.50 to 8.75 μg ml−1 of lorazepam. Multivariate calibration models using PLS at different pH and PARAFAC were elaborated for ultraviolet spectra deconvolution and lorazepam quantitation. The best models for the system were obtained with PARAFAC and PLS at pH = 2.05 (PLS-PH2). The capabilities of the method for the analysis of real samples were evaluated by determination of lorazepam in pharmaceutical preparations and biological (urine and plasma) fluids with satisfactory results. The accuracy of the method, evaluated through the root mean square error of prediction (RMSEP), was 0.0429 for lorazepam with best calibration curve by PARAFAC and 0.0467 for lorazepam with PLS model at best pH. The protolytic equilibria of lorazepam at 25 °C and ionic strength of 0.1 M have also been determined spectrophotometrically. Protolytic equilibria of lorazepam were evaluated by DATAN program using the corresponding absorption spectra-pH data. The obtained pKa values of lorazepam are 1.54 and 11.61 for pKa1 and pKa2, respectively.  相似文献   

13.
Simultaneous determination of total iron and vanadium by H-point standard addition method (HPSAM) and partial least squares (PLS) is described. Gallic acid (GA) in a cationic micellar solution of CTAB was used for determination of iron and vanadium in different oxidation states at pH 5. The presence of a micellar system enables total iron and vanadium to be determined with improved sensitivities. The total relative standard error for applying the PLS method to 15 synthetic samples in the ranges 0.20–15.00 μg ml−1 iron and 0.20–8.00 μg ml−1 vanadium was 2.2%. The results of applying the H-point standard addition method showed that iron and vanadium can be determined simultaneously with the concentration ratios of iron to vanadium from 10:1 to 1:20 in the mixed sample. Both HPSAM and PLS methods showed suitable abilities to resolve accurately overlapped absorption spectra of the compounds. Both proposed methods were successfully applied to the determination of Fe and V in several synthetic alloy solutions.  相似文献   

14.
A kinetic spectrophotometric method for the simultaneous determination of iodate and periodate in mixtures was proposed. The method is established on the different kinetic behaviours of the analytes which react with starch–iodide in the presence of sodium chloride in sulfuric acid medium. The kinetic data were collected from 260 to 900 nm every 10 nm, within a time range of 0–180 s at 1 s interval, and the absorbance collected at 291, 354 and 585 nm, respectively, increased linearly with the concentration between 0.1–1.2 mg L− 1 for both iodate and periodate. The mechanism investigation revealed that the iodate/periodate–iodide–starch system is a consecutive reaction. Subsequently, the mathematical model for the quantitative kinetic determination based on the consecutive reactions by utilizing chemometric methods was deduced, and the simultaneous determination of synthetic mixtures of iodate and periodate was then applied. Kinetic data collected at 291, 354 and 585 nm, were processed by chemometric methods, such as classical least square (CLS), principal component regression (PCR), partial least square (PLS), back-propagation artificial neural network (BP-ANN), radial basis function–artificial neural network (RBF-ANN) and principle component–radial basis function–artificial neural network (PC-RBF-ANN). The results showed that calibration model with the data collected at 354 nm had some advantages for the prediction of the analytes as compared with the ones of other two wavelengths, and the PLS and PC-RBF-ANN gave the lower prediction errors than other chemometric methods. The proposed method was applied to the simultaneous determination of iodate and periodate in several real samples; and the standard addition method yielded satisfactory recoveries in all instances.  相似文献   

15.
A rapid, simple, and sensitive differential kinetic method is presented for the determinations of acetaminophen (also known as paracetamol) and salicylamide. The method is based on their oxidation reaction by Fe3+ ion in the presence of 1, 10-phenanthroline as indicator. The reactions can be monitored spectrophotometrically by measuring the increase in the absorbance of the solution at 510 nm. Two times were selected one in which only paracetamol is oxidized by Fe3+ ion and the other in which both drugs are oxidized by Fe3+ ion. The data were evaluated by the proportional equations method. The method allowed the simultaneous determination of paracetamol and salicylamide at concentrations between 0.5-20 and 1-40 microg/mL with relative standard deviations of 3.47 and 2.58%, respectively. The method was applied to the simultaneous determination of paracetamol and salicylamide in human serum and pharmaceutical formulations.  相似文献   

16.
A simple, robust and sensitive sequential injection spectrophotometric method for the assay of penicillamine (PA) in pharmaceutical formulations is developed. The method was based on the complex formation when PA is reacted with iron(III) solution in hydrochloric acid media. The deep blue colored PA-iron(III) complex produced is monitored at a maximum wavelength of 600 nm. A five level orthogonal array design coupled to genetic algorithm was employed to obtain the optimum experimental conditions for the determination of PA using peak absorbance as the measure of the system's performance criterion. A linear dynamic range for the determination of PA of 25-300 ppm was obtained with a sampling frequency of 50 h−1 and a relative standard deviation of less than 0.98%. The method was successfully applied to the determination of PA in pharmaceutical formulations.  相似文献   

17.
在pH 4.0的B-R缓冲溶液中,速灭威、残杀威和呋喃丹能够产生内源荧光,但光谱严重重叠。当波长差Δλ=30 nm时,加入一定量的β-环糊精,3种农药的荧光强度均有不同程度的加强,且荧光强度与农药的浓度呈良好的线性关系,速灭威、残杀威和呋喃丹单组分的测量线性范围分别为0.2~2.0、0.02~0.38和0.04~0.56μg/mL;检出限分别为0.083、0.015和0.020μg/mL。应用多种化学计量学方法,如经典最小二乘(CLS)、主成分回归(PCR)和偏最小二乘(PLS)对同步荧光光谱严重重叠的3种农药混合体系合成样进行光谱解析并比较其分析能力。结果表明,PLS预报各组分的结果较好,采用该模型分析了一些实际食品样品,获得满意的结果。  相似文献   

18.
A differential spectrophotometric method has been developed for the simultaneous quantitative determination of glucose (GLU), fructose (FRU) and lactose (LAC) in food samples. It relies on the different kinetic rates of the analytes in their oxidative reaction with potassium ferricyanide (K3Fe(CN)6) as the oxidant. The reaction data were recorded at the analytical wavelength (420 nm) of the K3Fe(CN)6 spectrum. Since the kinetic runs of glucose, fructose and lactose overlap seriously, the condition number was calculated for the data matrix to assist with the optimisation of the experimental conditions. Values of 80 °C and 1.5 mol l−1 were selected for the temperature and concentration of sodium hydroxide (NaOH), respectively. Linear calibration graphs were obtained in the concentration range of 2.96-66.7, 3.21-67.1 and 4.66-101 mg l−1 for glucose, fructose and lactose, respectively. Synthetic mixtures of the three reducing sugar were analysed, and the data obtained were processed by chemometrics methods, such as partial least square (PLS), principal component regression (PCR), classical least square (CLS), back propagation-artificial neural network (BP-ANN) and radial basis function-artificial neural network (RBF-ANN), using the normal and the first-derivative kinetic data. The results show that calibrations based on first-derivative data have advantages for the prediction of the analytes and the RBF-ANN gives the lowest prediction errors of the five chemometrics methods. Following the validation of the proposed method, it was applied for the determination of the three reducing sugars in several commercial food samples; and the standard addition method yielded satisfactory recoveries in all instances.  相似文献   

19.
A spectrophotometric method for the simultaneous determination of the important pharmaceuticals, pefloxacin and its structurally similar metabolite, norfloxacin, is described for the first time. The analysis is based on the monitoring of a kinetic spectrophotometric reaction of the two analytes with potassium permanganate as the oxidant. The measurement of the reaction process followed the absorbance decrease of potassium permanganate at 526nm, and the accompanying increase of the product, potassium manganate, at 608nm. It was essential to use multivariate calibrations to overcome severe spectral overlaps and similarities in reaction kinetics. Calibration curves for the individual analytes showed linear relationships over the concentration ranges of 1.0-11.5mgL(-1) at 526 and 608nm for pefloxacin, and 0.15-1.8mgL(-1) at 526 and 608nm for norfloxacin. Various multivariate calibration models were applied, at the two analytical wavelengths, for the simultaneous prediction of the two analytes including classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), radial basis function-artificial neural network (RBF-ANN) and principal component-radial basis function-artificial neural network (PC-RBF-ANN). PLS and PC-RBF-ANN calibrations with the data collected at 526nm, were the preferred methods-%RPE(T) approximately 5, and LODs for pefloxacin and norfloxacin of 0.36 and 0.06mgL(-1), respectively. Then, the proposed method was applied successfully for the simultaneous determination of pefloxacin and norfloxacin present in pharmaceutical and human plasma samples. The results compared well with those from the alternative analysis by HPLC.  相似文献   

20.
Ni Y  Cao D  Kokot S 《Analytica chimica acta》2007,588(1):131-139
A sensitive and selective enzymatic kinetic method for the simultaneous determination of mixtures of carbaryl and phoxim pesticides was researched and developed. It was based on the inhibitory effect of the pesticides on acetylcholinesterase (AChE), and the use of 5,5′-dithiobis(2-nitrobenzoic) acid (DTNB) as a chromogenic reagent for the thiocholine iodide (TChI) released from the acetylthiocholine iodide (ATChI) substrate. The DTNB-thiocholine reaction was investigated by a spectrophotometric-kinetic approach. The complex rate equation for the formation of the chromogenic product, P, was solved under certain experimental conditions, which enabled the absorbance (AP, at λmax = 412 nm) from the mixtures of the two pesticide inhibitors to be directly related to their concentrations provided the absorbance additivity was followed. The spectra were measured for mixtures of carbaryl and phoxim at different concentrations, and at t = 904 s, T = 35 °C, pH = 7.5, cATChI = 0.14, and cAChE = 0.10 mg mL−1. The detection limits of the enzymatic kinetic spectrophotometric procedures for the determination of the carbaryl and phoxim were 4.7 and 0.59 μg L−1, respectively.Calibration models for chemometrics methods, such as principal component regression (PCR), partial least squares (PLS) and radial basis function-artificial neural network (RBF-ANN) were constructed and verified with synthetic samples of the mixtures of the two pesticides. The best performing model was based on the RBF-ANN method yielding at approximately 10 ppb analyte concentrations, %RPET (carbaryl = 5.2; phoxim = 6.5), %Recovery (approx.105%) and %RPET (6.5). Various spiked town-water samples produced recoveries in the range of 98.8-103% for each pesticide.  相似文献   