首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, we evaluate advantages and disadvantages of three hyphenated techniques for mercury speciation analysis in different sample matrices using gas chromatography (GC) with mass spectrometry (GC-MS), inductively coupled plasma mass spectrometry (GC-ICP-MS) and pyrolysis atomic fluorescence (GC-pyro-AFS) detection. Aqueous ethylation with NaBEt(4) was required in all cases. All systems were validated with respect to precision, with repeatability and reproducibility <5% RSD, confirmed by the Snedecor F-test. All methods proved to be robust according to a Plackett-Burnham design for 7 factors and 15 experiments, and calculations were carried out using the procedures described by Youden and Steiner. In order to evaluate accuracy, certified reference materials (DORM-2 and DOLT-3) were analyzed after closed-vessel microwave extraction with tetramethylammonium hydroxide (TMAH). No statistically significant differences were found to the certified values (p=0.05). The suitability for water samples analysis with different organic matter and chloride contents was evaluated by recovery experiments in synthetic spiked waters. Absolute detection and quantification limits were in the range of 2-6 pg for GC-pyro-AFS, 1-4 pg for GC-MS, with 0.05-0.21 pg for GC-ICP-MS showing the best limits of detection for the three systems employed. However, all systems are sufficiently sensitive for mercury speciation in environmental samples, with GC-MS and GC-ICP-MS offering isotope analysis capabilities for the use of species-specific isotope dilution analysis, and GC-pyro-AFS being the most cost effective alternative.  相似文献   

2.
3.
Capelo JL  Fernandez C  Pedras B  Santos P  Gonzalez P  Vaz C 《Talanta》2006,68(5):1442-1447
The field of selenium speciation has been studied for decades and the growing interest in this field seems never to reach a plateau. Although powerful techniques based on mass spectrometry are nowadays used for selenium determination/speciation, few laboratories can support the high cost of such techniques. The hyphenation of chromatography to atomic absorption or atomic fluorescence spectrometry (AAS or AFS) is still a reliable and low-cost alternative for routine laboratories. In this work we present the most important parameters dealing with selenium speciation along with the latest trends in this subject, namely in the items related with sample treatment and hyphenation techniques with AAS and AFS detection.  相似文献   

4.
This review covers the application of mass spectrometry (MS) and its hyphenated techniques to synthetic polymers of varying architectural complexities. The synthetic polymers are discussed as according to their architectural complexity from linear homopolymers and copolymers to stars, dendrimers, cyclic copolymers and other polymers. MS and tandem MS (MS/MS) has been extensively used for the analysis of synthetic polymers. However, the increase in structural or architectural complexity can result in analytical challenges that MS or MS/MS cannot overcome alone. Hyphenation to MS with different chromatographic techniques (2D × LC, SEC, HPLC etc.), utilization of other ionization methods (APCI, DESI etc.) and various mass analyzers (FT-ICR, quadrupole, time-of-flight, ion trap etc.) are applied to overcome these challenges and achieve more detailed structural characterizations of complex polymeric systems. In addition, computational methods (software: MassChrom2D, COCONUT, 2D maps etc.) have also reached polymer science to facilitate and accelerate data interpretation. Developments in technology and the comprehension of different polymer classes with diverse architectures have significantly improved, which allow for smart polymer designs to be examined and advanced. We present specific examples covering diverse analytical aspects as well as forthcoming prospects in polymer science.  相似文献   

5.
分离分析技术在蛋白质组学研究中应用的新进展   总被引:1,自引:0,他引:1  
张养军  张万军  马岩  彭博  钱小红 《色谱》2009,27(5):537-550
蛋白质组学研究的核心技术之一是分离分析方法。该综述重点评述了分离分析技术在蛋白质组学研究,即在蛋白质组表达谱构建、翻译后修饰蛋白质组研究、蛋白质复合体和相互作用研究、蛋白质组定量研究中应用的新进展,介绍了各种分离分析方法的优点、应用范围和有待解决的问题。引用文献89篇。  相似文献   

6.
Isotope labeling liquid chromatography–mass spectrometry (LC–MS) is a major analytical platform for quantitative proteome analysis. Incorporation of isotopes used to distinguish samples plays a critical role in the success of this strategy. In this work, we optimized and automated a chemical derivatization protocol (dimethylation after guanidination, 2MEGA) to increase the labeling reproducibility and reduce human intervention. We also evaluated the reagent compatibility of this protocol to handle biological samples in different types of buffers and surfactants. A commercially available liquid handler was used for reagent dispensation to minimize analyst intervention and at least twenty protein digest samples could be prepared in a single run. Different front-end sample preparation methods for protein solubilization (SDS, urea, Rapigest™, and ProteaseMAX™) and two commercially available cell lysis buffers were evaluated for compatibility with the automated protocol. It was found that better than 94% desired labeling could be obtained in all conditions studied except urea, where the rate was reduced to about 92% due to carbamylation on the peptide amines. This work illustrates the automated 2MEGA labeling process can be used to handle a wide range of protein samples containing various reagents that are often encountered in protein sample preparation for quantitative proteome analysis.  相似文献   

7.
8.
This paper reports the effect of transfer line (TL) internal diameter (i.d.) on gas chromatographic separation characteristics such as efficiency and speed, when a multicapillary (MC) column is used for speciation analysis of mercury. Five different TL consisting of fused-silica capillaries with 0.15, 0.20, 0.25, 0.32, and 0.53 mm i.d. are compared. The separation efficiency and total chromatographic run time are critically affected by the i.d. of the TL. Narrow capillaries (i.d.0.20 mm) produce minimum peak dispersion whereas wide capillaries result in narrow peaks and shorter chromatographic analysis times. A thermodynamic approach is proposed to describe the motion of the analytes through the separation column and TL. The model provides good agreement with the experimental data for high pressures (35 psig) and wide TL (0.25 mm i.d.).Dedicated to the memory of Wilhelm Fresenius  相似文献   

9.
以亲水作用色谱为核心的液相色谱联用技术及其应用研究   总被引:7,自引:0,他引:7  
王媛  顾惠新  路鑫  许国旺 《色谱》2008,26(6):649-657
亲水作用色谱(HILIC)是近年来色谱领域研究的热点之一。本文围绕复杂体系样品中亲水性组分的分离分析,综述了国际上近年 来发展的以HILIC为核心的多种液相色谱联用技术及其应用。简要介绍了HILIC的起源、定义、分离特点及其常用固定相;比较了HILIC和反相色谱(RPLC)的选择特性;针对不同层次的分离对象和分离要求,讨论了多种基于HILIC的液相色谱以及液相色谱-质谱联用技术的分离特点和适用范围。  相似文献   

10.
11.
The metabolism of selenium (Se) in the human body has yet not completely been unravelled and hence, an efficient method for characterization and on-line monitoring of the main Se-compound in human urine after consumption of Se-rich food was developed. Total Se-concentration in human urine after consumption of several Se-rich products was measured with inductively coupled plasma mass spectrometry (ICP-MS). The highest Se concentration in urine was observed after 4-10 h. The urine samples were brought onto a reversed phase column and the Se was detected by ICP-MS. Parameters for liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) measurements were optimized by using commercially available sugars, because it is known that some of the urinary metabolites contain a sugar moiety. In order to characterize the predominant Se-metabolite, it was necessary to extensively clean-up the sample and preconcentrate the species. The main metabolite was measured on its precursor ion on three different m/z according to three isotopes of Se. Relative peak surfaces matched the relative abundances of the isotopes. The product ions could be measured in a human urine sample in accordance to the product ions of the commercially available sugars. Moreover, the evidence of a selenosugar was demonstrated by the use of the Se-isotopes when measuring the product ions. LC-ESI-MS-MS was proven to be very efficient for the characterization of the main urinary Se-metabolite and can be used for on-line monitoring of the compound in urine samples. The method can be extended for clinical screening after consumption of Se-(en)rich(ed) food by use of the Se-isotopic profile and/or of the typical product ions of (methyl)-N-acetyl-hexosamines.  相似文献   

12.
Mass spectrometry has arguably become the core technology for the characterization of food proteins and peptides. The application of mass spectrometry-based techniques for the qualitative and quantitative analysis of the complex protein mixtures contained in most food preparations is playing a decisive role in the understanding of their nature, structure, functional properties and impact on human health. The application of mass spectrometry to protein analysis has been revolutionized in the recent years by the development of soft ionization techniques such as electrospray ionization and matrix assisted laser desorption/ionization, and by the introduction of multi-stage and ‘hybrid’ analyzers able to generate de novo amino acid sequence information. The interfacing of mass spectrometry with protein databases has resulted in entirely new possibilities of protein characterization, including the high sensitivity mapping (femtomole to attomole levels) of post-translational and other chemical modifications, protein conformations and protein–protein and protein–ligand interactions, and in general for proteomic studies, building up the core platform of modern proteomic science. MS-based strategies to food and nutrition proteomics are now capable to address a wide range of analytical questions which include issues related to food quality and safety, certification and traceability of (typical) products, and to the definition of the structure/function relationship of food proteins and peptides. These different aspects are necessarily interconnected and can be effectively understood and elucidated only by use of integrated, up-to-date analytical approaches. In this review, the main aspects of current and perspective applications of mass spectrometry and proteomic technologies to the structural characterization of food proteins are presented, with focus on issues related to their detection, identification, and quantification, relevant for their biochemical, technological and toxicological aspects.  相似文献   

13.
Pelzing M  Neusüss C 《Electrophoresis》2005,26(14):2717-2728
Liquid chromatography (LC) nanoelectrospray-tandem mass spectrometry (MS/MS) is a key technology for the study of proteomics, with the main benefit to the characterization of sensitive peptides from complex mixtures. Capillary electrophoresis coupled to mass spectrometry (MS) has been taken into consideration sporadically due to the highly efficient separation and ability to handle low sample amount, yet classified as being less sensitive with respect to analyte concentration. The limitation in capillary zone electrophoresis (CZE) injection volumes can be overcome by on-line solid-phase extraction (SPE). Such an on-line SPE-CZE system was explored in combination with an ion trap (IT) mass spectrometer. Thus, it was possible to inject more than 100 microL sample solution on to the CZE capillary. Concentration limits of detection as low as 100 amol/microL were demonstrated for a peptide standard. This SPE-CZE-microelectrospray ionization (ESI)-MS/MS setup was compared directly to nanoLC/nanoESI using the same sample of a tryptic digest of bovine serum albumin (BSA) as a reference standard. Measurements were made on one IT mass spectrometer with identical acquisition parameters. Both chromatography systems enabled the separation and detection of low levels of peptides from a mixture of moderate complexity, with most peptides identified using both techniques; however, specific differences were obvious. The nanoLC-MS is about five times more sensitive than the CZE-MS, yet the difference was less pronounced than expected. The CZE-MS technique showed reduced loss of peptides, especially for larger peptides (missed cleavages) and is about four times faster than the nanoLC-MS approach.  相似文献   

14.
Analytical techniques for the determination of polychorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF) and dioxin-like PCBs (DLPCB) are reviewed. The focus of the review is on recent advances in methodology and analytical procedures. The paper also reviews toxicology, the development of toxic equivalent factors (TEF) and the determination of toxic equivalent quantity (TEQ) values. Sources, occurrence and temporal trends of PCDD/PCDF are summarized to provide examples of levels and concentration ranges for the methods and techniques reviewed.  相似文献   

15.
The expression of gangliosides in central nervous system is a few times higher than in the extraneural tissue, a characteristic highlighting their major role at this level. Although in very low amounts, gangliosides are ubiquitously distributed in body fluids too, where, depending on many factors, including pathological states, their composition fluctuates, thus having diagnostic value. Ganglioside investigation in biological fluids, which, except for cerebrospinal fluid (CSF), may be sampled noninvasively, was for years impeded by the limited sensitivity of the analytical instrumentation available in glycomics. However, because the last decade has witnessed significant developments in biological mass spectrometry (MS) and the hyphenated separation techniques, marked by a major increase in sensitivity, reproducibility, and data reliability, ganglioside research started to be focused on biofluid analysis by separation techniques coupled to MS. In this context, our review presents the achievements in this emerging field of gangliosidomics, with a particular emphasis on modern liquid chromatography (LC), thin-layer chromatography, hydrophilic interaction LC, and ion mobility separation coupled to high-performance MS, as well as the results generated by these systems and allied experimental procedures in profiling and structural analysis of gangliosides in healthy or diseased body fluids, such as CSF, plasma/serum, and milk.  相似文献   

16.
The collection, storage, and transportation of water samples from far-off places to the labs is a pretty challenging task. It can cause contamination, degradation, or losses of the analytes, leading to errors in the analysis. On-site sample preparation provides an opportunity to extract the analytes into suitable extraction media that preserves the analytes and is easy to handle in terms of storage and transportation. However, the required equipment for on-site sample preparation should be simple, portable, and energy-efficient. Solvent- and sorbent-based microextraction approaches and the modern variants of solid-phase extraction have shown great potential for on-site sample preparation because of reduced consumption of solvents and low energy requirement. This review provides an overview of the application of different extraction techniques in on-site sample preparation, their advantages, and their limitations. The recent advances combining on-site extraction and analysis have also been critically discussed.  相似文献   

17.
本研究制备了一种应用于液-质联用(LC-MS)系统中的带喷头混合型毛细管色谱柱.用标准蛋白和酵母蛋白胰蛋白酶酶切溶液考察了其在LC—MS中的离子化效率、毛细管色谱柱分离性能和寿命,并与直接填充型毛细管色谱柱的色谱性能进行比较,未见显著性差异.将制备的带喷头混合型毛细管色谱柱应用于鼠肝蛋白组的分析,在假阳性率为1%的条件下鉴定到1262个肽段,归属于513个蛋白簇.通过对鉴定蛋白质理化性能的统计分析,其等电点和分子量分布高于一般两维凝胶电泳的范围.实验结果还表明该混合型毛细管色谱柱在肽段的理化性能上没有偏性,可以广泛应用于蛋白质组学的研究中.  相似文献   

18.
Lead is recognized worldwide as a poisonous metal. Thus, the determination of this element is often required in environmental, biological, food and geological samples. However, these analyses are difficult because such samples contain relatively low concentrations of lead, which fall below the detection limit of conventional analytical techniques such as flame atomic absorption spectrometry and inductively coupled plasma optical emission spectrometry. Several preconcentration procedures to determine lead have therefore been devised, involving separation techniques such as liquid-liquid extraction, solid phase extraction, coprecipitation and cloud point extraction. Citing 160 references, this paper offers a critical review of preconcentration procedures for determining lead using spectroanalytical techniques.  相似文献   

19.
This work presents two techniques for testing for the adulteration of flavors. One uses multidimensional gas chromatography on cyclodextrin derivatives to separate chiral compounds, the other uses isotope ratio mass spectrometry coupled with gas chromatography to determine stable isotope ratios. Applications to fruits and plants for the food and perfume industry are introduced.  相似文献   

20.
Analysis of environmental samples usually requires time consuming sample preparation and clean-up procedures prior to instrumental detection. Faster analysis requires an enhanced instrumental selectivity in order to reduce the necessary clean-up effort. In this context we present a novel concept for coupling gas chromartography/mass spectrometry (GC-MS) with high resolution UV spectoscopy to increase selectivity. We use UV-laser induced, resonance-enhanced multi-photon ionization (REMPI)as a compound specifie ion source for time-of-flight mass spectrometry (TOFMS). The REMPI ionization involves the UV absorption spectroscopy into the ionization process as an aditional analytical dimension. The heart of the GC-REMPI-TOFMS coupling is a specially designed valve, which repetitively (20 Hz) expands the chromatographic eluent as short supersonic jet gas pulses (≈ 150 μs duration) into the vacuum of the mass specrtrometer. The sample molecules are cooled down to temperatures of 10-40 K within the jet expansion. Under these conditions, UV absorption spectriscopy (i.e. REMPi spectroscopy) becomes highly compound selective, even able to distinguish isomeric compounds. The ions formed by REMPI ionization are mass analyzed in the TOFMS. Thus the GC-REMPI-TOFMS coupling presented here is actually a three-dimensional analytical instrument, providing gas chromatographic (retention time) as well as mass spectrometric (molecular mass) and UV -spectroscopic (excitation laser wavelength) selectivity. In combination with gas phase sampling and concentration techniques for semi-volatile organic air pollutants based, e.g., on silicone rubber traps the GC-LAMS technique can be a powerful tool for fast environmental target analysis, e.g. for industrial emission control purposes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号