共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
Emilie‐Laure Zins David Rondeau Philippe Karoyan Céline Fosse Sophie Rochut Claude Pepe 《Journal of mass spectrometry : JMS》2009,44(12):1668-1675
Benzylpyridinium ions are often used as ‘thermometer ions’ in order to evaluate the internal energy distribution of the ions formed in sources of mass spectrometers. However, the detailed fragmentation pathways of these parent ions were not well established. In particular, fragmentation involving a rearrangement (RR) process may be influencing the simulated distribution curves. In a previous study, we suggested that such RR actually occurred under electrospray ionization/mass spectrometry (ESI/MS) and fast atom bombardment/mass spectrometry (FAB/MS) experiments. Here, we present a systematic study of different substituted benzylpyridinium ions. Theoretical calculations showed that RR fragmentation leading to substituted tropylium ions could occur under ‘soft ionization’ conditions, such as ESI or FAB. Experimental results obtained under gas‐phase reactivity conditions showed that some substituted benzylpiridinium compounds actually undergo RR fragmentations under ESI/MS conditions. Mass‐analyzed kinetic experiments were also carried out to gain information on the reaction pathways that actually occur, and these experimental results are in agreement with the reaction pathways theoretically proposed. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
4.
表面解吸常压化学电离源的研制及应用 总被引:10,自引:0,他引:10
根据表面解吸常压化学电离源(SDAPCI)对表面痕量待测物进行常压解吸化学电离的原理,自行研制了SDAPCI电离源及其与线性离子阱(LTQ)质谱仪的接口,成功地在LTQ上实现了表面解吸常压化学电离。此方法无需样品预处理,直接利用电晕放电产生的H3O 在常压下对待测样品进行表面解吸化学电离,避免了甲醇等有毒试剂的使用。在优化的仪器参数条件下,分别用正/负离子模式成功地检测了片剂药品中的氯雷他定、乙酰氨基酚等活性成分和其它不同表面上TNT、氨基酸和多肽等物质,对这些常见物质的检出限不高于10pg/cm2。采用氩气作为电离试剂,观测到乙酰氨基酚、多肽等物质形成的自由基阳离子,提出了在氩气氛围中获得自由基阳离子的可能机理。实验表明SDAPCI具有灵敏度较高,选择性好,适用范围宽等特点,适合用于药品、食品等非破坏、无污染检测以及对复杂基体物质进行快速现场分析。 相似文献
5.
Geyer R Peacock AD White DC Lytle C Van Berkel GJ 《Journal of mass spectrometry : JMS》2004,39(8):922-929
An atmospheric pressure photoionization (APPI) source and an atmospheric pressure chemical ionization (APCI) source were compared for the selective detection of microbial respiratory ubiquinone and menaquinone isoprenologues using tandem mass spectrometry. Ionization source- and compound mass-dependent parameters were optimized individually for both sources, using the available quinone standards. Detection levels for the two ion sources were determined with ubiquinone-6 (UQ6) and menaquinone-4 (MK4, vitamin K2) standards using flow injection analysis and selected reaction monitoring (SRM). With APPI the calculated lower limit of detection (LLOD) was 1.7 fmol microl(-1) for UQ6 and 2.2 fmol microl(-1) for MK4 at a signal-to-noise ratio of 3. These LLODs were at least three times lower than with APCI. The selectivity of detection afforded by SRM detection reduced complex mixture analysis to 3 min per sample by eliminating the need for chromatographic separations. The detection method was successfully applied to quinone quantification in a variety of environmental samples and cell cultures. Adequate amounts of respiratory quinones can be extracted and quantified from samples containing as low as 2 x 10(7) cells. 相似文献
6.
The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports. 相似文献
7.
Liying Ding Feng Hong Yongzhong Ouyang Rui Chen Shumin Zhou Huanwen Chen Xiang Fang 《Journal of mass spectrometry : JMS》2013,48(9):1042-1049
Molecular images of documents were obtained by sequentially scanning the surface of the document using desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI‐MS), which was operated in either a gasless, solvent‐free or methanol vapor‐assisted mode. The decay process of the ink used for handwriting was monitored by following the signal intensities recorded by DAPCI‐MS. Handwritings made using four types of inks on four kinds of paper surfaces were tested. By studying the dynamic decay of the inks, DAPCI‐MS imaging differentiated a 10‐min old from two 4 h old samples. Non‐destructive forensic analysis of forged signatures either handwritten or computer‐assisted was achieved according to the difference of the contour in DAPCI images, which was attributed to the strength personalized by different writers. Distinction of the order of writing/stamping on documents and detection of illegal printings were accomplished with a spatial resolution of about 140 µm. A Matlab® written program was developed to facilitate the visualization of the similarity between signature images obtained by DAPCI‐MS. The experimental results show that DAPCI‐MS imaging provides rich information at the molecular level and thus can be used for the reliable document analysis in forensic applications. © 2013 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons, Ltd. 相似文献
8.
Reactive desorption electrospray ionization (reactive DESI) is demonstrated to be a rapid and sensitive method for the direct detection of alkyl methylphosphonic acids, the hydrolysis products and metabolites of the chemical warfare (CW) agents VX (S-2-diisopropylaminoethyl-O-ethyl methylphosphonothiolate) and GB (sarin, isopropylmethyl phosphonofluoridate). Rapid and sensitive detection of these compounds is readily achieved by performing DESI from a solid surface; detection specificity is enhanced by implementation of a heterogeneous ion/molecule reaction using boric acid in the spray solvent. The reagent ion H(2)BO(3) (-) generated in the spray readily reacts with condensed-phase alkyl MPA to form anionic adducts. The specificity of this chemical reaction, together with the characteristic fragmentation patterns of the reaction products, supplies a highly discriminatory detection method for methylphosphonic acid (MPA), ethylphosphonic acid (EMPA) and isopropyl methylphosphonic acid (IMPA) in complex matrices. 相似文献
9.
A sensitive and specific method for the determination of memantine in human plasma is presented. Memantine was extracted from plasma and derivatized to the pentafluorobenzoyl derivative in a one-step procedure avoiding any sample concentration steps. Amantadine was used as an internal standard. The compounds were measured by gas chromatography/negative ion chemical ionization mass spectrometry without any further processing. Using this detection mode, the fragment ions at m/z 353 and 325 were obtained at high relative abundance. Calibration graphs were linear over the range 0.117-30 ng ml(-1). At the limit of quantification (LOQ), the inter-assay precision was 2.00% and the intra-assay variability was 3.22%. The accuracy at the LOQ showed deviations of -1.42% (intra-assay) and -2.47% (inter-assay). The method is rugged, rapid and robust and was applied to the batch determination of memantine during pharmacokinetic profiling of the drug. 相似文献
10.
11.
Trötzmüller M Guo X Fauland A Köfeler H Lankmayr E 《Journal of mass spectrometry : JMS》2011,46(6):553-560
Ionic chemical background noise in LC-MS has been one of the major problems encountered in trace analysis. In this study, the typical negative background ions in ESI LC-MS are investigated exemplarily. It was carried out using tandem mass spectrometry to study the products and precursors of the major background ions to examine their structures and structure relationship. Various typical LC eluents with different compositions and additives such as ammonium formate/formic acid and ammonium acetate/acetic acid have been studied. Several types of negative noise ions are concluded, which include the cluster chemical background ions only from mobile phase components and additives. Furthermore, there are also abundant clusters resulting from the solvation of some typical individual contaminants (e.g. additives and degradation products from tubing, impurities in the mobile phase, etc.), accompanied by some minor contribution from contaminants. The elemental composition of some selected ions was confirmed using the FT-ICR accurate mass measurement. This work provides us insight into information about the structures and types of common negative background ions and will help to understand their formation and origins. More importantly, it will guide us to prevent chemical noise interference in practice and also contribute to develop methods for noise reduction based on selective ion-molecule reactions. 相似文献
12.
Hiroyuki Inoue Hiroaki Hashimoto Susumu Watanabe Yuko T. Iwata Tatsuyuki Kanamori Hajime Miyaguchi Kenji Tsujikawa Kenji Kuwayama Noriyuki Tachi Naohito Uetake 《Journal of mass spectrometry : JMS》2009,44(9):1300-1307
A novel approach to the analysis of ecstasy tablets by direct mass spectrometry coupled with thermal desorption (TD) and counter‐flow introduction atmospheric pressure chemical ionization (CFI‐APCI) is described. Analytes were thermally desorbed with a metal block heater and introduced to a CFI‐APCI source with ambient air by a diaphragm pump. Water in the air was sufficient to act as the reactive reagent responsible for the generation of ions in the positive corona discharge. TD‐CFI‐APCI required neither a nebulizing gas nor solvent flow and the accompanying laborious optimizations. Ions generated were sent in the direction opposite to the air flow by an electric field and introduced into an ion trap mass spectrometer. The major ions corresponding to the protonated molecules ([M + H]+) were observed with several fragment ions in full scan mass spectrometry (MS) mode. Collision‐induced dissociation of protonated molecules gave characteristic product‐ion mass spectra and provided identification of the analytes within 5 s. The method required neither sample pretreatment nor a chromatographic separation step. The effectiveness of the combination of TD and CFI‐APCI was demonstrated by application to the direct mass spectrometric analysis of ecstasy tablets and legal pharmaceutical products. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
13.
A general mass spectrometric method able to recognize the site of substitution of monosubstituted pyridines is described. The method requires that the molecule under investigation forms, upon ionization and dissociation, the respective alpha-, beta- or gamma- pyridinium ion of m/z 78. Pyridinium ions are stable and common fragments of ionized and protonated pyridines and are found to function as appropriate structurally diagnostic fragment ions. They can be identified by their characteristic and nearly identical collision-induced dissociation behavior and distinguished by the combined use of two structurally diagnostic ion/molecule reactions with acetonitrile and 2-methyl-1,3-dioxolane. alpha-, beta- or gamma-substitution in pyridines can, therefore, be securely recognized via an MS-only method based on structurally diagnostic ions and by the inspection of a single molecule (no need for intracomparisons within the whole set of isomers). 相似文献
14.
《Journal of mass spectrometry : JMS》2017,52(8):526-533
It is of sustainable interest to improve the sensitivity and selectivity of the ionization process, especially for direct analysis of complex samples without matrix separation. Herein, four ambient ionization methods including desorption atmospheric pressure chemical ionization (DAPCI), heat‐assisted desorption atmospheric pressure chemical ionization (heat‐assisted DAPCI), microwave plasma torch (MPT) and internal extractive electrospray ionization (iEESI) were employed for comparative analysis of the navel orange tissue samples by mass spectrometry. The volatile organic compounds (e.g. ethanol, vanillin, leaf alcohol and jasmine lactone) were successfully detected by non‐heat‐assisted DAPCI‐MS, while semi‐volatile organic compounds (e.g. 1‐nonanol and ethyl nonanoate) together with low abundance of non‐volatile organic compounds (e.g. sinensetin and nobiletin) were obtained by heat‐assisted DAPCI‐MS. Typical nonvolatile organic compounds [e.g. 5‐(hydroxymethyl)furfural and glucosan] were sensitively detected with MPT‐MS. Compounds of high polarity (e.g. amino acids, alkaloids and sugars) were easily profiled with iEESI‐MS. Our data showed that more analytes could be detected when more energy was delivered for the desorption ionization purpose; however, heat‐sensitive analytes would not be detected once the energy input exceeded the dissociation barriers of the analytes. For the later cases, soft ionization methods such as iEESI were recommended to sensitively profile the bioanalytes of high polarity. Copyright © 2017 John Wiley & Sons, Ltd. 相似文献
15.
16.
The use of capillary column gas chromatography and gas chromatography/mass spectrometry for the analysis of a series of standard solutions (0.1 to 10 μg/ml) of 2,4,6-trinitrotoluene (TNT) and eight other nitroaromatic components was evaluated. The techniques included gas chromatography with electron capture detection (GC/ECD), full scan and selected ion monitoring gas chromatography/mass spectrometry with electron impact ionization (EI/FS and EI/SIM), full scan and selected ion monitoring gas chromatography/mass spectrometry with positive ion chemical ionization using methane reagent gas (PICI/FS and PICI/SIM), and full scan and selected ion monitoring gas chromatography/mass spectrometry with negative ion chemical ionization using methane reagent gas (NICI/FS and NICI/SIM). The performance of the techniques was comapared by determining the linear response range, precision, and detection limits of the analyses. 相似文献
17.
Organic peroxides such as the cumene hydroperoxide I (M(r) = 152 u), the di-tert-butyl peroxide II (M(r) = 146 u) and the tert-butyl peroxybenzoate III (M(r) = 194 u) were analyzed by atmospheric pressure chemical ionization mass spectrometry using a water-methanol mixture as solvent with a low flow-rate of mobile phase and unusual conditions of the source temperature (< or =50 degrees C) and probe temperature (70-200 degrees C). The mass spectra of these compounds show the formation of (i) an [M + H](+) ion (m/z 153) for the hydroperoxide I, (ii) a stable adduct [M + CH(3)OH(2)](+) ion (m/z 179) for the dialkyl peroxide II and (iii) several protonated adduct species such as protonated molecules (m/z 195) and different protonated adduct ions (m/z 227, 389 and 421) for the peroxyester III. Tandem mass spectrometric experiments, exact mass measurements and theoretical calculations were performed for characterize these gas-phase ionic species. Using the double-well energy potential model illustrating a gas-phase bimolecular reaction, three important factors are taken into account to propose a qualitative interpretation of peroxide behavior toward the CH(3)OH(2) (+), i.e. thermochemical parameters (DeltaHdegrees(reaction)) and two kinetic factors such as the capture constant of the initial stable ion-dipole and the magnitude of the rate constant of proton transfer reaction into the loose proton bond cluster. 相似文献
18.
为快速、无损地区分不同活力的咖啡种子,采用自行研制的表面解吸常压化学电离质谱(DAPCI-MS),在无需样品预处理的前提下,获得咖啡种子表面的化学指纹图谱,并分别进行了主成分分析(PCA)、聚类分析(CA)和判别分析(DA),获得不同活力的咖啡种子样品的质谱信息特征.结果表明,在正离子模式下,DAPCI-MS结合多变量分析方法能有效区分不同活力的咖啡种子.PCA提取了3个主成分,累计贡献率达到92.2%;CA可以将相同活力的咖啡种子聚在一起,准确率为100%;DA对训练样本的回判正确率为100%,交叉验证分析成功率为100%,对外部验证样本进行DA,正确率95.7%.本方法具有无需样品预处理,分析速度快,灵敏度高,对种子无损伤等优点,能为其它种子活力测定提供参考. 相似文献
19.
以脐橙果皮为研究对象,比较了室温和热辅助表面解吸常压化学电离源(DAPCI)的解吸电离特性,结合串联质谱技术,对果皮中香气、糖、黄酮类等主要成分进行了鉴定,并通过主成分分析(PCA)方法对热辅助DAPCI-MS所获外果皮指纹谱图信息进行分析,进而区分了3个不同产地脐橙。 结果表明,室温DAPCI-MS对脐橙果皮中的香气成分具有较强的解吸电离能力,而热辅助DAPCI-MS则更适合于分析果皮中的黄酮类和糖类及其衍生物。 DAPCI-MS具有灵敏度高、分析速度快等特点,有望成为农产品品质快速检测与产地识别研究的新方法。 相似文献
20.
Petr Fryčák Jaromír Jirkovský Václav Ranc Petr Bednář Vladimír Havlíček Karel Lemr 《Journal of mass spectrometry : JMS》2012,47(6):720-726
Atmospheric pressure chemical ionization is known for producing unusual artifacts of the ionization process in some cases. In this work, processes occuring in atmospheric pressure chemical ionization/MS of orotic acid that afforded ions accompanying protonated and deprotonated orotic acid molecules in the spectra were studied. Two processes ran in parallel in the ion source: decarboxylation of neutral orotic acid and collision‐induced dissociation of its protonated or deprotonated form. A procedure discerning pre‐ionization decomposition and post‐ionization dissociation by manipulating ion source parameters was proposed. Experiments with isotopically labeled solvents confirmed ion–molecule reactions of the product of collision‐induced dissociation of protonated orotic acid with solvent molecules in the ion source and even under vacuum in the ion trap. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献