首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A capillary zone electrophoresis method for analysis of polymyxin B sulfate is described. In this method, triethanolamine (TEA)-phosphate buffer at pH 2.5 was employed to reduce the adsorption of analyte onto the capillary wall. Methyl-beta-cyclodextrin (M-beta-CD) and 2-propanol (IPA) were found to be necessary for selectivity enhancement. In order to optimize the method and to control its robustness, a central composite design was performed with four parameters, i.e. concentration of M-beta-CD, TEA, IPA and buffer pH. The optimal separation conditions were as follows: capillary, 55 cm (50 microm I.D., 47 cm effective length); 130 mM TEA-phosphate buffer (pH 2.5) containing 5 mM M-beta-CD and 5% IPA; 24 kV (51 microA) applied voltage; column temperature, 20 degrees C. Further, linearity and limits of detection quantification were examined. Three commercial samples were analyzed quantitatively.  相似文献   

2.
A method for the quantitative analysis of colistin sulfate by capillary zone electrophoresis is described. Since colistin components have five free amino groups, they tend to adsorb onto the capillary wall and cause peak tailing. It was found that triethanolamine (TEA)-phosphate buffer at pH 2.5 was useful to reduce such adsorption. Methyl-beta-cyclodextrin (M-beta-CD) and 2-propanol (IPA) were found necessary for selectivity enhancement. In order to optimize the separation parameters and predict the method robustness, a central composite design was performed including three variables, namely concentration of M-beta-CD, TEA, and IPA. The effects of capillary length and applied voltage on separation were also investigated. The optimal conditions established were: 140 mM TEA-phosphate buffer containing 5 mM M-beta-CD and 6% v/v IPA, a capillary with 55 cm total length (50 microm inner diameter, 47 cm from inlet to detection window) and 24 kV applied voltage. The method was found to be robust when the variables were changed in the following range: 4-6 mM M-beta-CD, 5-7% v/v IPA, and 130-150 mM TEA. Further, the linearity, limit of detection (LOD), and limit of quantitation (LOQ), as well as repeatability for both colistin A and B were examined and three commercial samples were quantitatively analyzed.  相似文献   

3.
The nonaqueous capillary electrophoresis mode which includes a preconcentration step based on a transient pseudo-isotachophoresis to the simultaneous separation of seven glucoconjugated and hydroxylated porphyrins and chlorins, exhibiting very close structures, is reported. A high methanol content, of the buffer solution, was necessary in order to prevent self-assembly of the compounds and to enhance their solubility during separation. With the addition of 66% (v/v) methanol and 1% (w/v) NaCl in the aqueous sample solution, large volumes could be injected (44% capillary volume) without a loss in resolution. Sensitivity of detection was therefore improved by a 100-fold factor with regard to the method employing normal injection (2% capillary volume). Optimum electrophoretic conditions, in terms of sensitivity and performance, were obtained by using 20 mM phosphoric acid buffer, pH 2.2 and 50% methanol. The method was validated and applied to qualitative analysis of glucoconjugates in serum samples.  相似文献   

4.
A new method to improve the analyses of thiolic peptides (cysteine, γGlu-Cys, glutathione, phytochelatins and desglycyl-phytochelatins) derivatized with monobromobimane (mBrB) in complex biological samples by CZE is described. The method involves a SPE using Sep-Pak Light C18 Cartridges after derivatization and a later CZE analysis. Elution of mBrB-thiols was achieved with 10 mM HCl + 70% methanol v/v in deionised water. Electrophoretic parameters, such as BGE pH and concentration, different organic additives (methanol and trifluoroethanol), applied voltage and capillary length were studied in order to establish suitable analytical conditions. Optimum separation of the mBrB-thiolic peptides was obtained with 100 mM sodium borate buffer at pH 7.60. The electrophoretic conditions were +15 kV, capillary length of 90 cm from inlet to detector (98 cm total length, 50 μm ID), samples were loaded into the capillary by hydrodynamic injection (50 mbar, 20 s) and detection was performed at 390 nm. The improved method showed good reproducibility, linearity and sensitivity. The LODs and LOQs estimated using a standard of GSH were 1.41 and 4.69 μM respectively.  相似文献   

5.
A simple and fast capillary electrophoretic method has been developed for the enantioselective separation of citalopram and its main metabolites, namely N-desmethylcitalopram and N,N-didesmethylcitalopram, using beta-cyclodextrin (beta-CD) sulfate as the chiral selector. For method optimisation several parameters were investigated, such as CD and buffer concentration, buffer pH, and capillary temperature. Baseline enantioseparation of the racemic compounds was achieved in less than 6 min using a fused-silica capillary, filled with a background electrolyte consisting of a 35 mM phosphate buffer at pH 2.5 supplemented with 1% w/v beta-CD sulfate and 0.05% w/v beta-CD at 25 degrees C and applying a voltage of -20 kV. A fast separation method for citalopram was also optimized and applied to the analysis of pharmaceutical formulations. Racemic citalopram was resolved in its enantiomers in less than 1.5 min using short-end injection (8.5 cm, effective length) running the experiments in a background electrolyte composed of a 25 mM citrate buffer at pH 5.5 and 0.04% w/v beta-CD sulfate at a temperature of 10 degrees C.  相似文献   

6.
Summary A capillary zone electrophoresis method has been developed and validated for the analysis of chlortetracycline and related substances. The influence of the type of buffer, pH and concentration of the buffer were investigated. In all cases 1 mM EDTA was added to prevent metal ion complexation. Instrumental parameters such as capillary temperature and applied voltage were optimised. The following methods is proposed: capillary: fused silica, 44 cm (36 cm effective length), 50 μm i.d.; buffer: 120 mM sodium tetraborate including 1mM EDTA at pH 8.5; voltage: 10 kV; temperature: 25°C; detection wavelength: 280 nm. The robustness of the method has been examined by means of a full-fraction factorial design. The parameters for validation namely relative standard deviation, linearity, precision, limit of detection and limit of quantitation are also reported.  相似文献   

7.
The conditional binding constants for a bis-guanidinium-like receptor and a series of dicarboxylate ligands have been determined in two buffer/solvent systems, namely 25 mM ammonium acetate/1% acetic acid in acetonitrile/methanol (7:3 v:v) and 30 mM N-methyl morpholine/15 mM methanesulfonic acid in acetonitrile/methanol (9:1 v:v). The latter buffer has not been applied before in capillary electrophoresis. The binding constants in both solvent systems decrease as the dicarboxylate length increases. The binding constants are larger in the less competitive N-methyl morpholine buffer. The dicarboxylates associate only weakly with a dicationic analog of the receptor, p-xylyl trimethylammonium, which is not a hydrogen bond donor.  相似文献   

8.
A capillary electrophoresis (CE) method has been developed that allows the separation and estimation of primaquine enantiomers using hydroxypropyl-gamma-cyclodextrin (HP-gamma -CD) as a chiral selector. The influence of chemical and instrumental parameters on the separation, such as type and concentration of CD, buffer concentration, buffer pH, applied voltage, capillary temperature, and injection time, were investigated. Good separation of the racemic mixture of primaquine was achieved using a fused-silica capillary (52.5 cm effective length x 50 microm id) and a background electrolyte composed of tris-phosphate buffer solution (50 mM, pH 2.5) containing 15 mM HP-gamma-CD as a chiral selector. The recommended applied voltage, capillary temperature, and injection time were 15 kV, 25 degrees C, and 6 s, respectively. Within-day and interday reproducibility of peak area and migration time gave relative standard deviation values ranging from 1.05-3.30%. Good recoveries (range of 96.8-104.9%) were obtained from the determination of placebos that were spiked with 0.25-1.00 mg/L primaquine. The proposed CE method was successfully applied to the assay of primaquine diphosphate in pharmaceutical formulations (tablets).  相似文献   

9.
Oguri S  Hibino M  Mizunuma M 《Electrophoresis》2004,25(12):1810-1816
We report on the effect on performance of varying the length of the capillary during throughout in-capillary derivatization (TICD) capillary electrophoresis (CE). Performance was evaluated by on-line coupling with a sample and CE runbuffer loading device that was newly introduced for this study. The device was assembled with a low cost using two 5 mm inner diameter (ID) disposable polyethylene syringes. First, a sequence was manually formed consisting of a 200 microL run buffer solution plug, a 100 microL sample plug and another 200 microL run buffer solution plug. Each plug was separated from its neighbor by a 100 microL air plug. When each plug reached the injection point where both a platinum-wire anode and the end of the separation capillary tube were located, 340 V/cm separation voltage (electrophoresis voltage) and 34 V/cm injection voltage were applied to the capillary for 3 s. Then the analytes were derivatized during migration in 50 microm ID capillaries filled with 2 mM o-phthalaldehyde (OPA)/N-acetylcysteine (NAC) in a 20 mM phosphate-borate buffer (pH 10), followed by separating and detecting of OPA derivatives by absorbance of 340 nm. Derivatization, separation, and detection were performed systematically using capillaries which varied in length from 5 to 80 cm. In the case of TICD-CE of a mixture containing 1 mM aspartic acid (Asp) and 20 mM m-nitorophenol (MNP) as a test solution, it was determined that peak area and peak width ratios of Asp to MNP did not depend on capillary length. Enantiomeric separations of DL-alanine (Ala) and Asp were examined using a run buffer consisting of a 45 microM beta-cyclodextrin (CD)-2 mM OPA/NAC-20 mM phosphate-borate buffer (pH 10). Even though the resolution of these enantiomeric pairs decreased with decreasing capillary length, as expected, the peaks corresponding to both enantiomeric amino acids were identified even when a 5 cm capillary was used. An 8-component amino acid mixture was also tested with 5 cm and 10 cm capillaries.  相似文献   

10.
A novel and simple method has been developed for the determination of doxycycline (DOX) in biological fluids. The method is based on SPE, large-volume sample stacking (LVSS) and MEKC with UV-DAD detection. Six SPE cartridges have been used in investigation for sample clean up and pre-concentration (Supelco LC-8, LC-18, LC-SCX, and LC-WCX, as well as Strata-X and X-C). DOX was determined on a 56 cm (effective length 50 cm) x 50 microm id fused-silica capillary. The BGE was 20 mM borate buffer, pH 9.3, containing 80 mM SDS and 7.5% v/v of methanol (30 sx50 mbar), and the temperature and voltage were 25 degrees C and 30 kV, respectively. The analytical wavelength was set at 210 nm. Under optimized conditions it is possible to determine DOX in human serum, urine, semen, tears and saliva with recovery of 97.5% (RSD 2.5%). The method was shown to be sensitive (LOD is 1 microg/L) and precise (intra-day RSD 0.2 and 2.4%; inter-days 0.4 and 3.5% for migration time and peak area, respectively). Results for developed SPE-LVSS-MEKC were compared with LVSS-MEKC method with direct sample injection. The new LVSS-MEKC method is presented as a useful technique for rapid determination without extraction procedure of DOX in human urine and serum, using 80 mM of SDS, 10% v/v of methanol and 40 mM borate buffer (pH 9.3; 30 s x 50 mbar; 25 degrees C; 30 kV; 350 nm), but not for the other biological fluids, according to lower sensitivity of the method and because of the sample composition.  相似文献   

11.
A new method to improve the analysis of phytochelatins and their precursors (cysteine, gamma-Glu-Cys, and glutathione) derivatized with monobromobimane (mBrB) in complex biological samples by capillary zone electrophoresis is described. The effects of the background electrolyte pH, concentration, and different organic additives (acetonitrile, methanol, and trifluoroethanol) on the separation were studied to achieve optimum resolution and number of theoretical plates of the analyzed compounds in the electropherograms. Optimum separation of the thiol peptides was obtained with 150 mM phosphate buffer at pH 1.60. Separation efficiency was improved when 2.5% v/v methanol was added to the background electrolyte. The electrophoretic conditions were 13 kV and capillary dimensions with 30 cm length from the inlet to the detector (38 cm total length) and 50 microm inner diameter. The injection was by pressure at 50 mbar for 17 s. Under these conditions, the separation between desglycyl-peptides and phytochelatins was also achieved. We also describe the optimum conditions for the derivatization of biological samples with mBrB to increase electrophoretic sensitivity and number of theoretical plates. The improved method was shown to be simple, reproducible, selective, and accurate in measuring thiol peptides in complex biological samples, the detection limit being 2.5 microM glutathione at a wavelength of 390 nm.  相似文献   

12.
程晓昆  王利娟  杨更亮  程佳  张轶华 《色谱》2010,28(11):1089-1093
建立了匹伐他汀钙对映体的毛细管区带电泳(CZE)拆分方法。分别考察了电泳电压,缓冲溶液种类、浓度及pH值,环糊精种类及浓度,添加剂种类及浓度等参数对实验结果的影响,从而确定了匹伐他汀钙对映体的最佳拆分条件: 电泳电压为18 kV;运行缓冲溶液为80 mmol/L的Tris-HCl缓冲体系,pH值为3.20,其中含有50 mmol/L HP-β-CD(羟丙基-β-环糊精)和5 mmol/L SDS(十二烷基磺酸钠);采用重力进样,进样高度17 cm,进样时间为2 s。在优化的实验条件下,匹伐他汀钙对映体得到了较好的分离,分离度可达2.17。实验结果表明该方法可用于匹伐他汀钙对映体的分离,具有快速、便捷、准确性好等优点。  相似文献   

13.
A micellar electrokinetic chromatography (MEKC) method was validated for the analysis of ezetimibe. The method was carried out on a fused-silica capillary (50 microm i.d.; effective length, 40 cm). The background electrolyte consisted of a 25 mM borate buffer and 25 mM anionic detergent SDS (pH 9.75)/methanol (90:10, v/v). The capillary temperature was maintained at 35 degrees C, the applied voltage was 30 kV; the injection was performed using a pressure mode at 50 mbar for 5 s, with detection at 232 nm. The method was linear in the range of 2-150 microg/mL (R2=0.9999). The specificity and the stability-indicating capability were proven through degradation studies, which also showed that there was no interference of the excipients. The limits of quantitation and detection were 2 and 0.41 microg/mL, respectively. The method was applied for the analysis of ezetimibe pharmaceutical formulations, and the results were compared to those of the liquid-chromatography method.  相似文献   

14.
EKC methods for the enantiomeric resolution of homocamptothecin derivatives, potent anticancer agents targeting DNA topoisomerase I selected for clinical trials, were developed using highly sulfated beta-CD as chiral selectors at acidic pH. Optimal electrophoretic conditions, with migration times under 15 min, were as follows: for the neutral homocamptothecin analog 1, a BGE of 75 mM phosphate buffer pH 2.5 (H(3)PO(4) + triethanolamine)/ACN - 95/5 v/v, with 7.5% w/v highly S-beta-CD, an applied field of 0.2 kV/cm and a fused capillary temperature control of 30 +/- 0.1 degrees C (typical current approximately 175 microA); for the cationic homocamptothecin 2, a BGE of 25 mM phosphate buffer pH 2.5 (H(3)PO(4) + TEA)/ACN - 90/10 v/v, with 2.5% w/v highly S-beta-CD, an applied field of 0.15 kV/cm and a fused capillary temperature control of 25 +/- 0.1 degrees C (typical current approximately 45 muA), and both are validated. The best results in terms of LOQ were obtained by EC with fluorescence detection: 10 ng/mL and 20 ng/mL for 1 and 2, respectively (LOQ divided by 150 for 1 and 5 for 2 with respect to UV), thus making this method particularly convenient for enantiomeric purity determination of galenic forms. UV detection appears to be an alternative to fluorescence for the analysis of the main component either for the control of galenic forms or for therapeutic adaptation. Moreover, this method exhibits better performances than HPLC.  相似文献   

15.
An innovative protocol for the fast analysis of some organic acids in red wine by co-electroosmotic capillary zone electrophoresis and indirect UV detection using hexadimethrine bromide (HDB) as coating agent was proposed. The adsorption of HDB onto the capillary wall provided a stable electroosmotic flow and separation of small anions was carried out using background electrolytes containing no polymer additive. Low RSD% values (<3.6%) in terms of migration times and effective mobilities were obtained from the analysis of a mixture of nitrate and nitrite and of a mixture of organic acids. An experimental design approach was used to investigate the effects of temperature, separation voltage, and percentage of methanol added to the running buffer solution on the separation of the analytes. A faster method allowing the separation of the organic acids involved in the malolactic fermentation of wine was developed. Using a running electrolyte consisting of 35% (v/v) methanol in a solution of 22 mM benzoic acid at pH 6.10 adjusted with 1.0 M TRIS-base buffer, the separation of tartaric, malic, succinic, acetic, and lactic acids was feasible in less than 210 s. Application of the method to the quantification of the above-mentioned organic acids in Italian red wine samples is reported.  相似文献   

16.
聚类分析辅助中药寡糖电泳分析鉴定中药   总被引:5,自引:0,他引:5  
郭怀忠  吴芳  张伟泉  刘芳黎 《色谱》2013,31(10):1001-1004
基于中药多糖结构的复杂性和特征性,针对多糖部分降解后的寡糖片段,建立了一种采用毛细管区带电泳法(CZE)分离分析中药寡糖,并利用其特征性电泳谱图信息,结合聚类分析(CA)进行中药鉴定的方法。该方法以1-苯基-3-甲基-5-吡唑啉酮(PMP)为寡糖柱前衍生化试剂,对3个科属的6种中药如黄精、玉竹等同时进行鉴定。采用的电泳条件:未涂层熔融石英毛细管柱(49 cm(有效长度40 cm)×50 μm),以50 mmol/L磷酸盐缓冲液(pH 2.5)为运行缓冲液,检测波长为245 nm,运行电压为15 kV,虹吸进样10 cm×4 s,柱温为室温。结果表明聚类分析辅助中药寡糖电泳分析法可有效用于3个科属6种中药的鉴定。本方法结果可靠,重现性好,可以作为中药鉴定的一种有效手段。  相似文献   

17.
A rapid capillary zone electrophoresis method has been developed capable of quantifying 0.05% of R-enantiomer and assaying the main component in escitalopram formulations. Many parameters influencing enantioseparation were investigated, which include chiral selectors, buffer composition and pH, applied voltage, capillary length, temperature, and rinsing procedure. Optimal separation conditions were obtained by using a 25 mM phosphate buffer at pH 7.0, containing 1.6% (w/v) sulfated-β-cyclodextrin with short-end injection at 0.5 psi for 5 s. Online UV detection was performed at 205 nm. A voltage of -20 kV was applied and the capillary temperature was kept at 25°C. Separation was achieved in less than 2 min. The method was further validated, including robustness, stability of the solution, selectivity, linearity (escitalopram from 0.25 μg/mL to 600 μg/mL, y = 1528.3 × +1812.9; R2 = 0.9999), LOD and LOQ (0.08 and 0.25 μg/mL, respectively), precision and accuracy. The proposed method was then applied to the quality control of the bulk sample and tablets of escitalopram (10 mg).  相似文献   

18.
A rapid and cost‐effective method based on microwave‐assisted extraction followed by capillary electrophoresis was developed for simultaneous quantification of seven alkaloids in Corydalis decumbens for the first time. The main parameters affecting microwave‐assisted extraction and capillary electrophoresis separation were investigated and optimized. The optimal microwave‐assisted extraction was performed at 40°C for 5 min using methanol/water (90:10, v/v) as the extracting solvent. Electrophoretic separation was achieved within 15 min using an uncoated fused‐silica capillary (50 μm internal diameter and 27.7 cm effective length) and a 500 mM Tris buffer containing 45% v/v methanol (titrated to pH* 2.86 with H3PO4). The developed method was successfully applied to the quantification of seven alkaloids in Corydalis decumbens obtained from different regions of China. The combination of microwave‐assisted extraction with capillary electrophoresis was an effective method for the rapid analysis of the alkaloids in Corydalis decumbens .  相似文献   

19.
Zhu HD  Lü WJ  Li HH  Ma YH  Hu SQ  Chen HL  Chen XG 《Journal of chromatography. A》2011,1218(34):5867-5871
This paper for the first time describes the development of micelle to solvent stacking (MSS) to nonaqueous capillary electrophoresis (NACE). In this proposed MSS-NACE, sodium dodecyl sulfate (SDS) micelles transport, release, and focus analytes from the sample solution to the running buffer using methanol as their solvent. After the focusing step, the focused analytes were separated via NACE. The focusing mechanism and influencing factors were discussed using berberine (BBR) and jatrorrhizine (JTZ) as model compounds. And the optimum condition was obtained as following: 50 mM ammonium acetate, 6% (v/v) acetic acid and 10 mM SDS in redistilled water as sample matrix, 50 mM ammonium acetate and 6% (v/v) acetic acid in pure methanol as the running buffer, -20 kV focusing voltage with 30 min focusing time. Under these conditions, this method afforded limits of detection (S/N=3) of 0.002 μg/mL and 0.003 μg/mL for BBR and JTZ, respectively. In contrast to conventional NACE, the concentration sensitivity was improved 128-153-fold.  相似文献   

20.
Gao F  Zhang Z  Fu X  Li W  Wang T  Liu H 《Electrophoresis》2007,28(9):1418-1425
A hyphenated method of nonaqueous capillary electrophoresis coupled to electrospray ionization mass spectrometry (NACE-ESI-MS) is described for the simultaneous analysis of phospholipids. The best results were obtained with a mixed solution of methanol/ACN (40:60 v/v) containing 20 mM ammonium acetate and 0.5% acetic acid, under the applied voltage of 30 kV and capillary temperature of 25 degrees C. ESI-MS measurements were performed in the negative mode with methanol/ACN (40:60 v/v) containing 50 mM ammonium acetate as sheath liquid at a flow rate of 2 microL/min. Different phospholipid classes have been successfully separated within 16 min, and the molecular species of every single class have been identified by using MS(2) or MS(3), which generates characteristic fragments through CID. The developed method has been applied to analyze the phospholipids extracted from rat peritoneal surface and the molecular species of phospholipid classes are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号