首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple screening method of organic aciduria by spectrofluorometric measurement of total dicarboxylic acids in human urine is described. This method is based on an intramolecular excimer-forming fluorescence derivatization with a pyrene reagent, 4-(1-pyrene)butanoic acid hydrazide (PBH). Dicarboxylic acids in urine were converted to the corresponding dipyrene-labeled derivatives by reaction with PBH in the presence of 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and pyridine, and the derivatives afforded intramolecular excimer fluorescence (420-540 nm) which can clearly be discriminated from the normal fluorescence (360-420 nm) emitted from reagent blanks. The technique is so selective that it permits spectrofluorometric measurement of total amount of dicarboxylic acids by the direct derivatization of diluted urine samples. The same reaction mixture has also served as a liquid chromatographic (LC) sample for the separative determination of individual dicarboxylic acids. The spectrofluorometric data did not contradict with the LC data. These methods were usefully applied to preliminary screening test of glutaric aciduria. In conclusion, the present derivatization method allows rapid and direct determination of total amount of dicarboxylic acids in human urine samples.  相似文献   

2.
A highly sensitive and selective fluorimetric determination method for dicarboxylic acids (C5-C12) has been developed. This method is based on an intramolecular excimer-forming fluorescence derivatization with a pyrene reagent, 4-(1-pyrene)butyric acid hydrazide (PBH), followed by reversed-phase liquid chromatography (LC). The carboxylic acids were converted to the corresponding dipyrene-labeled derivatives by reaction with PBH in the presence of 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide. The derivatives afforded intramolecular excimer fluorescence (450-550 nm) which can clearly be discriminated from the normal fluorescence (370-420 nm) emitted from PBH and monopyrene-labeled derivatives of monocarboxylic acids. The structures of the derivatives and the emission of excimer fluorescence were studied by LC with mass spectrometry and with spectrofluorimetry, respectively. The PBH derivatives of the carboxylic acids could be separated by reversed-phase LC on an ODS column with isocratic elution. The detection limits (signal-to-noise ratio = 3) were 1.3 fmol to undetectable for a 20-microl injection.  相似文献   

3.
A highly sensitive and selective fluorometric determination method for ornithine and lysine has been developed. This method is based on an intramolecular excimer-forming fluorescence derivatization with a pyrene reagent, 4-(1-pyrene)butyric acid N-hydroxysuccinimide ester (PSE), followed by reversed-phase liquid chromatography (LC). The analytes, containing two amino moieties in a molecule, were converted to the corresponding dipyrene-labeled derivatives by reaction with PSE. The derivatives afforded intramolecular excimer fluorescence (450-550 nm) which can clearly be discriminated from the normal fluorescence (370-420 nm) emitted from PSE and monopyrene-labeled derivatives of monoamines. The structures of the derivatives and the emission of excimer fluorescence were confirmed by LC with mass spectrometry and with three-dimensional fluorescence detection system, respectively. The PSE derivatives of ornithine and lysine could be separated by reversed-phase LC on ODS column with isocratic elution. The detection limits (signal-to-noise ratio = 3) for ornithine and lysine were 3.5 and 3.7 fmol, respectively, for a 20-microl injection. Furthermore, this method had enough selectivity and sensitivity for the determination of ornithine and lysine in normal human urine.  相似文献   

4.
A liquid chromatographic (LC) determination of catecholamines and indoleamines is described. This is based on intramolecular excimer-forming fluorescence derivatization with 4-(1-pyrene)butanoyl chloride, followed by reversed-phase LC. The analytes, containing an amino moiety and phenolic hydroxyl moieties in a molecule, were converted to the corresponding polypyrene-labeled derivatives by one-step derivatization. They afforded intramolecular excimer fluorescence, which can clearly be discriminated from the normal fluorescence emitted from reagent blanks. The detection limits (S/N = 3) for catecholamines and indoleamines were femto-mole levels per 20-microL injection. Furthermore, this method was applied to a urine assay.  相似文献   

5.
A liquid chromatographic method for highly sensitive and selective fluorometric determination of polyamines (putrescine, cadaverine, spermidine and spermine) in human urine is described. This method is based on an intramolecular excimer-forming fluorescence derivatization with a pyrene reagent, 4-(1-pyrene)butanoyl chloride (PBC), followed by reversed-phase liquid chromatography. The method offers higher sensitivity for determination of spermidine and spermine than previously reported method utilizing 4-(1-pyrene)butyric acid N-hydroxysuccinimide ester as a derivatization reagent. Samples containing free polyamines in diluted human urine were directly derivatized with PBC and separated on an octyl column. The derivatives were detected at excitation 345 and emission 475 nm wavelengths. For determination of total polyamine content, the conjugated polyamines were first hydrolyzed in 4 M HCl. The detection limits (signal-to-noise ratio = 3) for polyamines in urine were 1.1-3.4 pmol/mL. At optimized derivatization and chromatographic conditions, interferences such as biogenic monoamines gave no peaks or the peaks did not interfere with the peaks of polyamine derivatives. In conclusion, the present derivatization method allows direct determination of polyamines in human urine samples without the need for sample clean-up procedures.  相似文献   

6.
A selective and sensitive fluorometric determination method for native fluorescent peptides has been developed. This method is based on intramolecular fluorescence resonance energy transfer (FRET) detection in a liquid chromatography (LC) system following precolumn derivatization of the amino groups of tryptophan (Trp)-containing peptides. In this detection process, we monitored the FRET from the native fluorescent Trp moieties (donor) to the derivatized fluorophore (acceptor). From a screening study involving 10 fluorescent reagents, we found that o-phthalaldehyde (OPA) generated FRET most effectively. The OPA derivatives of the native fluorescent peptides emitted OPA fluorescence (445 nm) through an intramolecular FRET process when they were excited at the excitation maximum wavelength of the Trp-containing peptides (280 nm). The generation of FRET was confirmed through comparison with the analysis of a non-fluorescent peptide (C-reactive protein fragment (77 - 82)) performed using LC and a three-dimensional fluorescence detection system. We were able to separate the OPA derivatives of the Trp-containing peptides when performing LC on a reversed-phase column. The detection limits (signal-to-noise ratio = 3) for the Trp-containing peptides, at a 20-microL injection volume, were 41 - 180 fmol. The sensitivity of the intramolecular FRET-forming derivatization method is higher than that of the system that takes advantage of the conventional detection of OPA derivatives. Moreover, native non-fluorescent amines and peptides in the sample monitored at FRET detection are weaker than those of conventional fluorescence detection.  相似文献   

7.
A highly sensitive, selective and simple method is described for the determination of histamine by high-performance liquid chromatography (HPLC) with fluorescence detection. The method is based on an intramolecular excimer-forming fluorescence derivatization of histamine with 4-(1-pyrene)butyric acid N-hydroxysuccinimide ester (PSE), followed by reversed-phase HPLC. Histamine, having two amino moieties in a molecule, was converted to the dipyrene-labeled derivative by reaction with PSE. The derivative afforded intramolecular excimer fluorescence (450-540 nm), which can clearly be discriminated from the monomer fluorescence (370-420 nm) emitted from PSE. Typically, a 10 micro L sample solution was mixed with 100 micro L of derivatization reagent solution, which was a mixture of 0.5 mm PSE in acetonitrile and 0.5 mm potassium carbonate in water (8:2, v/v). The derivatization was carried out at 100 degrees C for 90 min. The PSE derivative of histamine could be separated by reversed-phase ODS column with isocratic elution using acetonitrile:water (82:18, v/v) containing 0.03% triethylamine. The detection limit (singnal-to-noise ratio = 3) of histamine was 0.5 fmol for a 30 micro L injection. The method was successfully applied to the determination of histamine in human urine, and had enough selectivity and sensitivity for urinary histamine quantification.  相似文献   

8.
合成了新的荧光衍生试剂1-[2-(对甲苯磺酸酯)乙基]-2-苯基咪唑[4,5-f]9,10-菲(TSEPIP),并将其作为柱前衍生化试剂,在Eclipse XDB-C8色谱柱上采用梯度洗脱实现了11种长链(C20~C30)游离脂肪酸(FFA)衍生物的基线分离。利用柱后在线的串联质谱并以大气压化学电离源(APCI)的正离子模式实现了各组分的质谱定性。对土壤及3种苔藓(东亚毛灰藓、锦丝藓、羽平藓)中FFA组分的定量结果表明,苔藓植物从土壤中富集了大量的长链游离脂肪酸。荧光检测的激发波长和发射波长分别为260 nm和380 nm。线性回归系数大于0.9996,检测限为26.19~76.67 fmol。所建立的方法具有良好的重现性,对实际样品的测定结果令人满意。  相似文献   

9.
柱前手性衍生化反相高效液相色谱法分离拉贝洛尔对映体   总被引:4,自引:1,他引:3  
赵华  李惠芝  邱宗荫 《色谱》1999,17(4):369-371
以乙酰葡萄糖异硫氰酸酯(GITC)作柱前手性衍生化试剂,用反相高效液相色谱法成功地分离了拉贝洛尔的两对对映异构体,并以荧光检测和紫外检测作对照,确认了4个衍生物的色谱峰。  相似文献   

10.
We developed an LC method for the sensitive and selective fluorometric determination of polythiols. This method employs pre-column intramolecular excimer-forming fluorescence derivatization with N-(1-pyrene)iodoacetamide followed by LC separation. Polythiols were converted to the corresponding dipyrene-labeled derivatives, and the derivatives afforded intramolecular excimer fluorescence (440–540 nm). After the optimization using dithiothreitol and dimercaprol as model polythiols, α-lipoic acid (LA) and α-lipoamide were determined with high sensitivity and selectivity. The detection limits for polythiols were 0.6–3.5 fmol on column. Furthermore, this method could be successfully applied to the determination of LA in commercial dietary supplements and in human urine.  相似文献   

11.
血清中游离脂肪酸的液相色谱荧光测定及质谱鉴定   总被引:1,自引:0,他引:1  
利用新型荧光试剂1,2 苯并 3,4 二氢咔唑 9 乙基对甲苯磺酸酯(BDETS)对19种游离脂肪酸(FFAs)进行柱前衍生,在EclipseXDB C8反相色谱柱上,采用梯度洗脱优化分离.90℃下在DMF溶剂中以K2CO3作催化剂,衍生反应30min获得稳定的荧光产物.激发和发射波长分别为λex=333nm,λem=390nm,采用大气压化学电离源(APCI)正离子模式进行柱后在线质谱定性.多数脂肪酸的线性回归系数大于0.9989,检测限为24.80~80.37fmol.实现了人体血清中长链脂肪酸的定性及相应含量测定.  相似文献   

12.
A simple and sensitive fluorometric high-performance liquid chromatographic method was developed for the determination of midodrine in human plasma. After liquid-liquid extraction from plasma, the drug and 2-phenylglycinol (internal standard) were convened into the corresponding fluorescent derivatives by reaction with 3,4-dihydro-6,7-dimethoxy-4-methyl-3-oxoquinoxaline-2-carbonyl chloride, a fluorescence derivatization reagent for amines. The derivatives were separated within 30 min on a reversed-phase column using isocratic elution with acetonitrile-methanol-water (10:30:60, v/v) and were detected spectrofluorometrically at 485 nm with excitation at 400 nm. The detection limit for midodrine was 0.3 pmol (76 pg) per mL plasma at a signal-to-noise ratio of 3.  相似文献   

13.
在HypersilODS2色谱柱上,利用新型荧光试剂1,2-苯并-3,4-二氢咔唑-9-乙基肼基甲酸酯(BCEC)作柱前衍生化试剂,采用梯度洗脱对5种中性糖荧光衍生物进行了优化分离.65℃下在乙腈溶剂中以冰乙酸作催化剂,衍生反应6.5h后获得稳定的荧光产物,衍生反应完全.激发和发射波长分别为λex=333nm,λem=390nm.线性回归系数均在0.999以上,检测限为24.3~62.1fmol.  相似文献   

14.
In this study, a novel pre-column excimer fluorescence derivatization reagent, 2-chloro-4-methoxy-6-(4-(pyren-4-yl)butoxy)-1,3,5-triazine (CMPT), was developed for polyamines, specifically histamine. By CMPT derivatization, the polyamines, histamine and tyramine were converted to polypyrene derivatives, and emitted intra-molecular excimer fluorescence at 475 nm. This could clearly be distinguished from the normal fluorescence emitted from reagent blanks at 375 nm. Unlike conventional excimer fluorescence derivatization reagents, CMPT is chemically stable and its reactivity sustained over at least 36 days even in solution state. We successfully applied this reagent to the sensitive and selective analysis of histamine in different kinds of Japanese commercial soy sauces. The detection and quantification limits of histamine were 15 and 50 μg L−1, respectively, equating to 1.35 pmol and 4.5 pmol for a 6 μL injection. This sensitivity helped the direct analysis of soy sauce samples only treated by one-step liquid–liquid extraction without concentration. The histamine levels of commercial soy sauce samples (koikuchi, usukuchi and saishikomi) investigated were 1.24–768.5 mg L−1.  相似文献   

15.
A BODIPY-based fluorescent derivatization reagent with a hydrazine moiety, 1,3,5,7-tetramethyl-8-aminozide-difluoroboradiaza-s-indacene (BODIPY-aminozide), has been designed for aldehyde labeling. An increased fluorescence quantum yield was observed from 0.38 to 0.94 in acetonitrile when it reacted with aldehydes. Twelve aliphatic aldehydes from formaldehyde to lauraldehyde were used to evaluate the analytical potential of this reagent by high performance liquid chromatography (HPLC) on C18 column with fluorescence detection. The derivatization reaction of BODIPY-aminozide with aldehydes proceeded at 60 °C for 30 min to form stable corresponding BODIPY hydrazone derivatives in the presence of phosphoric acid as a catalyst. The maximum excitation (495 nm) and emission (505 nm) wavelengths were almost the same for all the aldehyde derivatives. A baseline separation of all the 12 aliphatic aldehydes (except formaldehyde and acetaldehyde) is achieved in 20 min with acetonitrile–tetrahydrofuran (THF)–water as mobile phase. The detection limits were obtained in the range from 0.43 to 0.69 nM (signal-to-noise = 3), which are better than or comparable with those obtained by the existing methods based on aldehyde labeling. This reagent has been applied to the precolumn derivatization followed with HPLC determination of trace aliphatic aldehydes in human serum samples without complex pretreatment or enrichment method.  相似文献   

16.
The polyamines putrescine, cadaverine, spermine and spermidine were separated and quantified by micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence detection. The derivatization reagent, 1-pyrenebutanoic acid succinimidyl ester (PSE), allowed for the selective detection of the polyamines at 490 nm. Multiple labeling of the polyamines with PSE allows the formation of intramolecular excimers that emit at longer wavelengths (450-520 nm) than mono-labeled analytes (360-420 nm). Optimal separation of the labeled polyamines was achieved using a separation buffer consisting of 10 mM phosphate pH 7.2, 30 mM cholate, and 30% acetonitrile. Using these conditions, the four polyamines were separated in under 10 min. Limits of detection for putrescine, cadaverine, spermine and spermidine were 6, 5, 15 and 13 nM, respectively. These are superior or comparable to those previously reported in the literature using fluorescence detection.  相似文献   

17.
A new HPLC procedure with precolumn derivatization and rimantadine as the internal standard for determining memantine, a candidate agent for the treatment of glaucoma in plasma and vitreous humour, has been developed and validated. Precolumn derivatization was performed with 9-fluorenylmethyl-chloroformate-chloride (FMOC-Cl) as the derivatization reagent and followed by a liquid-liquid extraction with n-hexane. Optimal conditions for derivatization were an FMOC-Cl concentration of 1.5 mM, a reaction time of 20 min, the temperature at 30°C, the borate buffer pH 8.5, and a borate buffer-acetonitrile ratio of 1:1. The derivatives were analyzed by isocratic HPLC with the fluorescence detector λex 260 nm λem 315 nm on a Novapack C(18) reversed-phase column with a mobile phase of acetonitrile-water (73:27, v/v), 40°C, and a flow rate of 1.2 mL/min. The linear range was 10-1000 ng/mL with a quantification limit of ~ 10 ng/mL for both types of samples. This analytical method may be suitable for using in ocular availability studies.  相似文献   

18.
A sensitive high-performance liquid chromatographic method was developed for the stereoselective assay of (R)- and (S)-propranolol in human plasma. The method involves diethyl ether extraction of the drugs and a racemic internal standard, N-tert.-butylpropranolol, followed by derivatization of the compounds with the chiral reagent (R,R)-O,O-diacetyl tartaric acid anhydride. The resulting diastereomeric derivatives were separated isocratically on a reversed-phase column. Quantitation was achieved by the peak-height ratio method with reference to the internal standard. The assay was accurate and reproducible in the concentration range 1-100 ng of (R)- and (S)-propranolol per ml plasma, using fluorescence detection at lambda ex 290 nm and lambda em 335 nm. The applicability of this method was demonstrated for the determination of concentration-time profiles of propranolol enantiomers in the course of comparative pharmacokinetic studies.  相似文献   

19.
利用新型荧光试剂4-(1H-菲并[9,10-d]咪唑-2-)苯甲酸(PIBA)进行柱前衍生并经荧光检测对脂肪胺进行了高效液相色谱(HPLC)分离和在线质谱定性。激发和发射波长分别为ex=261nm,em=443nm。80℃下在吡啶溶剂中用N-乙基-N’-[(3-二甲氨基)丙基]碳二亚胺盐酸盐(EDC)做催化剂,衍生反应10min后获得稳定的荧光产物。在EclipseXDB-C8色谱柱(4.6150mm,5mm)上,梯度洗脱对12种游离脂肪胺衍生物进行了优化分离。采用大气压化学电离源(APCI)正离子模式,实现了各种脂肪胺衍生物的测定。多数脂肪胺的线性回归系数大于0.9999,检测限为10.5~53.4fmol。  相似文献   

20.
A rapid, sensitive, and selective precolumn derivatization method for the simultaneous determination of eight thiophenols using 3‐(2‐bromoacetamido)‐N‐(9‐ethyl‐9H )‐carbazol as a labeling reagent by high‐performance liquid chromatography with fluorescence detection has been developed. The labeling reagent reacted with thiophenols at 50°C for 50 min in aqueous acetonitrile in the presence of borate buffer (0.10 mol/L, pH 11.2) to give high yields of thiophenol derivatives. The derivatives were identified by online postcolumn mass spectrometry. The collision‐induced dissociation spectra for thiophenol derivatives gave the corresponding specific fragment ions at m/z 251.3, 223.3, 210.9, 195.8, and 181.9. At the same time, derivatives exhibited intense fluorescence with an excitation maximum at λex = 276 nm and an emission maximum at λem = 385 nm. Excellent linear responses were observed for all analytes over the range of 0.033–6.66 μmol/L with correlation coefficients of more than 0.9997. Detection limits were in the range of 0.94–5.77 μg/L with relative standard deviations of less than 4.54%. The feasibility of derivatization allowed the development of a rapid and highly sensitive method for the quantitative analysis of trace levels of thiophenols from some rubber products. The average recoveries (n = 3) were in the range of 87.21–101.12%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号