首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
Jin W  Dong Q  Yu D  Ye X  Li W 《Electrophoresis》2000,21(8):1540-1544
A capillary electrophoresis (CE)/electrochemical detection system with on-line deoxygenation was developed, consisting of a deoxygenation injector, a deoxygenation protector, and an electrochemical detection cell. When the system was utilized for 60 min, the steady-state current of oxygen detected could be dropped to 3% of the original value for the gold/mercury amalgam electrode and to 8% of the original value for the gold electrode, and the limit of detection could be decreased two orders of magnitude for the reducible analytes such as TI+ (from 3.1 x 10-5 mol/L to 8.0 x 10-7 mol/L) and metronidazole (from 3.8 x 10-5 mol/L to 4.0 x 10-7 mol/L).  相似文献   

2.
A method based on micellar electrokinetic capillary chromatography with electrochemical detection was developed for the determination of cytosine, 5-methylcytosine (5-MC), thymine, adenine, and guanine in the hydrolysates of DNA. The working electrode was fabricated in a novel self-positioning carbon disc electrode system that can align the capillary outlet with the working electrode without a three-dimensional micromanipulator. The five analytes could be well separated within 10 min in a 40 cm length capillary at a separation voltage of 9 kV in a 40 mmol/l borate buffer (pH 10.0) containing 100 mmol/l sodium dodecyl sulfate. Good linearity was observed between peak current and concentration of bases over three orders of magnitude with the detection limits (SIN=3) ranging from 1.28 x 10(-6) to 5.02 x 10(-6) mol/l. This proposed method demonstrated long-term stability and reproducibility with relative standard deviations of less than 5% for both migration time and peak current (n=7). It has been successfully applied to determine bases including 5-MC in the hydrolysates of fish sperm DNA, calf thymus DNA, and DNA isolated from spleen cells of female mice.  相似文献   

3.
A method based on capillary electrophoresis with electrochemical detection (CE-ED) has been developed for the determination of hesperidin (HP) and synephrine (SP) in the Chinese traditional herbal drug, Pericarpium Citri Reticulatae, the dried rind of the ripe fruits of Citrus reticulata Blanco (mandarin orange). The effects of some important factors such as the acidity and concentration of running buffer, separation voltage, and detection potential were investigated to determine the optimum conditions. The working electrode was a 300 microm diameter carbon disc electrode positioned opposite the outlet of the capillary. Both analytes could be well separated within 5 min in a 40 cm long capillary at a separation voltage of 12 kV in 50 mmol L(-1) borate buffer (pH 9.0). Excellent linearity was observed for the dependence of peak current on analyte concentration in the range from 2.5 x 10(-6) to 1.0 x 10(-3) mol L(-1) for SP and from 5.0 x 10(-6) to 1.0 x 10(-3) mol L(-1) for HP. The detection limits (S/N=3) for SP and HP were 4.96 x 10(-7) mol L(-1) and 6.54 x 10(-7) mol L(-1), respectively. This method has been successfully applied for the analysis of real samples, with satisfactory results.  相似文献   

4.
A new chemically modified electrode based on the immobilization of Pt particles is fabricated and exhibits electrocatalytic oxidation for L-cysteine (L-Cys), glutathione (GSH) and penicillamine (PEN) with relatively high sensitivity. It is also adaptable to HPLC for pulsed amperometric detection (PAD) of these thiols. PAD largely improves the detection sensitivity because the alternated polarizations can effectively clean and reactivate the electrode surface. It is shown that the peak currents of L-Cys, GSH and PEN are linear to their concentrations, with the calculated detection limit of 1.1 x 10(-7), 1.8 x 10(-7) and 3.8 x 10(-7) mol L(-1), respectively (S/N = 3). The method has been successfully applied to assess the contents of L-Cys and GSH in rat striatal microdialysates. The average contents of the two analytes in rat striatum are 2.6 x 10(-6) and 2.8 x 10(-6) mol L(-1), respectively.  相似文献   

5.
A method based on capillary electrophoresis with electrochemical detection was developed for the determination of puerarin, daidzein and rutin. Effects of several important factors such as the acidity and concentration of running buffer, separation voltage, injection time, and detection potential were investigated to acquire the optimum conditions. The working electrode was a 300-microm diameter carbon disc electrode positioned opposite the outlet of capillary. The three analytes could be well separated within 12 min in a 40 cm length capillary at a separation voltage of 9 kV in a 50 mmol/l borate buffer (pH 9.0). The relationship between peak currents and analyte concentrations was linear over about three orders of magnitude with detection limits (SIN=3) ranging from 0.241 x 10(-6) to 0.511 x 10(-6) mol/l for all compounds. This proposed method demonstrated long-term stability and reproducibility with relative standard deviations of less than 5% for both migration time and peak current (n=7). It has been successfully applied for the determination of puerarin, daidzein and rutin in Chinese traditional drugs, the vines of Pueraria lobata (Wild.) Ohwi and Puerariae Radix.  相似文献   

6.
The aim of this work was voltammetric determination of 1-aminopyrene and 1-hydroxypyrene using carbon paste electrodes modified with cyclodextrin derivatives and double stranded deoxyribonucleic acid (dsDNA). The detection schemes based on a preconcentration and differential pulse voltammetric (DPV) determination at beta-cyclodextrin and gamma-cyclodextrin modified carbon paste electrode (beta-CD/CPE, gamma-CD/CPE), neutral beta-cyclodextrin polymer and carboxymethyl-beta-cyclodextrin polymer modified screen-printed electrode (beta-CDP/SPE, beta-CDPA/SPE) and dsDNA modified screen-printed electrode (DNA/SPE) are proposed for the trace determination of studied analytes within the concentration range from 2 x 10(-8) to 4 x 10(-7) mol dm(-3) and from 2 x 10(-7) to 4 x 10(-6) mol dm(-3) with the limits of quantification down to 10(-8) mol dm(-3). Depending on pH, 1-aminopyrene interacts with both surface attached CD and DNA by electrostatic bonds and supramolecular complexation while 1-hydroxypyrene associates with the CD hosts via complexation. The 1-aminopyrene interaction with dsDNA was confirmed by fluorimetric measurements in the solution phase using a competing DNA-TO-PRO-3 dye complex. In addition, the effect of temperature on this association was investigated using an electrically heated DNA-modified carbon paste electrode (DNA/CPE).  相似文献   

7.
Cao Y  Zhang X  Fang Y  Ye J 《The Analyst》2001,126(9):1524-1528
A simple, reliable and reproducible method, based on capillary electrophoresis (CE) with electrochemical detection (ED), for the determination of five active ingredients and three carbohydrates in extracts of Gastrodia rhizoma is described in this work. The main active ingredients are gastrodin, 4-hydroxybenzyl alcohol, vanillyl alcohol, 4-hydroxybenzylaldehyde and vanillin. Operated in a wall-jet configuration, a 300 microm diameter carbon disc electrode was used as a working electrode, with a good response at +1000 mV (vs. SCE) for 4-hydroxybenzyl alcohol, vanillyl alcohol, 4-hydroxybenzylaldehyde and vanillin; a 300 microm diameter copper disc electrode exhibits a good response at +650 mV (vs. SCE) for gastrodin, sucrose, glucose and fructose. Under optimum conditions, 4-hydroxybenzyl alcohol, vanillyl alcohol, 4-hydroxybenzylaldehyde and vanillin in 100 mmol l(-1) borate buffer (pH 9.2) and gastrodin, sucrose, glucose and fructose in 50 mmol l(-1) sodium hydroxide buffer were baseline separated within 18 min. The response was linear over two orders of magnitude with a detection limit (S/N = 3) in the range 3 x 10(-7)-1.8 x 10(-6) mol l(-1) for all eight analytes. This method was successfully used in the analysis of traditional Chinese medicine, and the assay results were satisfactory.  相似文献   

8.
A flow-injection electrochemiluminescent method for L-cysteine determination has been developed based on its enhancement of the electrochemiluminecence of luminol at a glassy carbon electrode. This method is simple and sensitive for cysteine determination. Under the selected experimental parameters, the linear range for cysteine concentration was 1.0 x 10(-6) - 5.0 x 10(-5) mol/l, and the detection limit was 0.67 micromol/l (S/N = 3). The relative standard deviation for 11 measurements of 1.0 x 10(-5) mol/l cysteine was 4.5%. The proposed method has been applied to the detection of cysteine in pharmaceutical injections with satisfactory results.  相似文献   

9.
陈新  袁红萍  曹玉华  陈秋云 《色谱》2010,28(9):889-892
建立了一个毛细管胶束电动色谱(MEKC)在线富集阴离子耗尽进样(ASEI)联用扫集(sweeping)技术测定3种甘草黄酮化合物(异甘草素、甘草素和甘草苷)的方法。考察了MEKC的分离条件和富集体系的优化条件,其中样品基质、水塞进入时间、进样时间对目标化合物的富集效果有较大的影响。在优化实验条件下,异甘草素、甘草素和甘草苷的富集倍数分别提高了110、120、300倍,检出限分别为0.015、0.014、0.011mg/L。该方法用于中药制剂中甘草素、异甘草素和甘草苷含量的测定,回收率在90.6%~107%之间,相对标准偏差(RSD)均小于4.5%(n=3)。实验证明,该方法可成功地应用于实际样品中甘草素、异甘草素和甘草苷含量的测定  相似文献   

10.
Cao W  Liu J  Yang X  Wang E 《Electrophoresis》2002,23(21):3683-3691
A new end-column electrochemiluminescence (ECL) detection technique coupling to capillary electrophoresis (CE) is characterized. A 300 microm diameter Pt working electrode was used to directly couple with a 75 microm inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy) 3 2+ showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy) 3 2+ in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 microm capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 220-260 microm. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 microm capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 x 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 x 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-8) mol/L.  相似文献   

11.
A new electrochemical method for the determination of microamounts of hydrogen peroxide utilizing o-dianisidine (ODA) as substrate and hemoglobin (Hb) as catalyst is described in this paper. Hb can be used as mimetic peroxidase and it can catalyse the reduction of hydrogen peroxide with the subsequent oxidation of ODA. The oxidative reaction product is an azo compound, which is an electroactive substance and has a sensitive second-order derivative polarographic reductive peak at the potential of -0.58 V (vs. SCE) in pH 80 Britton-Robinson (B-R) buffer solution. The conditions of Hb-catalytic reaction and polarographic detection of the reaction product were carefully studied. By using this polarographic peak and under optimal conditions, the calibration curve for the H2O2 was constructed in the linear range of 2.0 x 10-7 ∼ 10 x 10-4 mol/l with the detection limit of 5.0 x 10-8 mol/l. This method can also be used to the determination of Hb content in the range of 20 x 10-9 ∼ 30 x 10-7 mol/l with a detection limit of 10 x 10-9 mol/l. The proposed method was further applied to the determination of the content of H2O2 in fresh rainwater with satisfactory results. The catalytic reaction mechanism and the electrode reductive process of the reaction product were carefully studied.  相似文献   

12.
The clay mineral montmorillonite has been tested as modifier for the carbon paste electrode with a novel electrode modification technique. The differential pulse voltammetric determination of copper(II) by means of this modified carbon paste electrode has been studied. A detection limit of 4x10(-8) mol/l has been achieved after 10 min preconcentration under open circuit conditions with subsequent anodic stripping voltammetry. The calibration curve for Cu(II) is linear in the range of 4x10(-8)-8x10(-7) mol/l. Pb interferes in a 10-fold molar and Cd and Hg in a 100-fold molar excess. The interference by humic ligands is significant.  相似文献   

13.
Electrochemical behavior of thyroxine at a polyvinylpyrrolidone modified carbon paste electrode in the presence of cetyltrimethyl ammonium bromide was described. Thyroxine underwent totally irreversible oxidation at this system and a well-defined peak at 0.42 V was obtained. The influence of various surfactants on the oxidation of thyroxine was examined by cyclic voltammetry. Chronocoulometry was also used to investigate the electrode process. In the range 2 x 10(-7) to 9 x 10(-6)mol/l, the thyroxine concentration was linear with the oxidation peak current and a low detection limit of 8 x 10(-8) mol/l was obtained for 5 min accumulation.  相似文献   

14.
Capillary zone electrophoresis was employed for the determination of diclofenac sodium using an end-column amperometric detection with a carbon fiber microelectrode, at a constant potential of 0.83 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 4.90 x 10(-3) mol/l Na2HPO4-3.10 x 10(-3) mol/l NaH2PO4 (pH 7.0) for the buffer solution, 10 kV for the separation voltage, 5 kV and 10 s for the injection voltage and the injection time, respectively. The limit of detection is 2.5 x 10(-6) mol/l or 5.2 fmol (S/N=2). The relative standard deviation is 0.8% for the migration time and 4.7% for the electrophoretic peak current. The method was applied to the determination of diclofenac sodium in human urine.  相似文献   

15.
J N Li  J Zhang  P H Deng  J J Fei 《The Analyst》2001,126(11):2032-2035
A very sensitive and selective procedure was developed for trace measurement of zirconium based on the cathodic adsorptive stripping voltammetry of the zirconium-alizarin red S(ARS) complex at a carbon paste electrode (CPE). The 2nd-order derivative linear scan voltammograms of the zirconium-ARS complex were recorded by a model JP-303 polarographic analyzer from 0.0 to -1.0 V (vs. SCE). Optimal analytical conditions were found to be: an acetic acid (0.1 mol l(-1))-potassium biphthalate (0.08 mol l(-1)) buffer solution (pH 4.8) containing 4.0 x 10-6 mol l(-1) ARS; accumulation potential, 0.0 V; accumulation time, 180 or 90 s; rest time, 10 s; scan rate, 250 mV s(-1). The results showed that the complex can be adsorbed on the surface of the CPE, yielding one peak at -0.51 V, corresponding to the reduction of ARS in the complex at the electrode. The detection limit was found to be 1.0 x 10(-10) mol l(-1) (S/N = 3) for 240 s accumulation. The linear range was 2.0 x 10(-10)-4.0 x 10(-7) mol l(-1). The developed method was applied to the determination of trace zirconium in the ore samples with satisfactory results.  相似文献   

16.
The separation and quantitative performance parameters for tetracycline, chlortetracycline and oxytetracycline antibiotics were investigated by capillary zone electrophoresis coupled with fast cyclic voltammetric detection. Optimization of pH and complexation with a boric acid-sodium tetraborate buffer provided good resolution of all compounds. Detection by electrochemical reduction using fast on-line cyclic voltammetric detection with a Hg-film-microm electrode gave detection limits (2 x peak-to-peak baseline noise) of 7 x 10(-7) mol/l for tetracycline and chlortetracycline, and 1.5 x 10(-6) mol/l for oxytetracycline. The influence of electrode material, potential range and scan rate was examined and discussed. Optimal electrochemical detection was obtained at a Hg-film electrode with a waveform that consisted of an initial constant potential of -0.6 V for 200 ms followed by a cyclic voltammetry (CV) scan at 300 V/s from - 0.6 V to a vertex potential of 1.7 V. The analytical signal was obtained by plotting the integrated values of the CV current from each applied waveform as a function of time. The calibration plot (peak areas) for each separated peak was found to be linear over three-orders of magnitude.  相似文献   

17.
4-Amino-2-mercaptopyrimidine self-assembled monolayer (AMP SAMs/Au) was prepared on a gold electrode. The AMP SAMs/Au was characterized by using attenuated total reflection-fourier transform infrared (ATR-FTIR) and A.C. Impedance. The electrochemical behavior of brucine on AMP SAMs/Au was studied by cyclic voltammetry (CV) and square wave adsorptive stripping voltammetry (SWASV). The modified electrode showed an excellent electrocatalytic activity for the redox of brucine. The catalytic current increased linearly with the concentration of brucine in the range of 4.0 x 10(-7) to 2.0 x 10(-4) mol l(-1) by square wave voltammetry response. The detection limit was 6.0 x 10(-8) mol l(-1).  相似文献   

18.
Diffusion coefficient measurements in microfluidic devices   总被引:2,自引:0,他引:2  
A glassy carbon electrode (GCE) modified with Pd/IrO(2) provides excellent electrocatalytic oxidation of hydrogen peroxide. Glucose oxidase (GOD) and xanthine oxidase (XOD) were co-immobilized on the modified electrode with a thin film Nafion coated on the enzyme layer to form a glucose (Glu)/hypoxanthine (Hx) sensor, without interference from electroactive species such as ascorbic acid (AA) and uric acid (UA). Its response was evaluated with respect to the enzyme amount on the electrode, pH and temperature of the electrolyte. The prepared bienzymic biosensor, used as the detector of HPLC gave a detection limit of 1.0x10(-6) mol l(-1) Glu and 2.0x10(-7) mol l(-1) Hx (Hx) with a linear concentration range of 5.0x10(-6)-2.5x10(-3) mol l(-1) and 1.0x10(-6)-5.0x10(-4) mol l(-1), respectively. Coupled with microdialysis, it was used to monitor the concentrations of Glu and Hx in rat brain.  相似文献   

19.
An 1-(pyridylazo)-2-naphthol modified glassy carbon electrode has been investigated as sensor for the measurement of trace levels of Cd2+. Cd2+ is deposited on the surface of a PAN modified glassy carbon electrode at -1.10 V (vs. SCE) via forming Cd2+-PAN and subsequent reduction at the electrode. In the following step, Cd-PAN is oxidized, and voltammograms are recorded by scanning the potential in a positive direction. Calibration plots were found to be linear in the range 2 x 10(-8) mol/L to 8 x 10(-7) mol/L. The detection limit was 5 x 10(-10) mol/L, and the coefficient of variation, determined on one single electrode at a concentration of 5 x 10(-7) mol/L, was calculated to be 3.2% (n = 5). Using this new kind of modified electrode, trace levels of Cd(II) in water samples were determined; the average recovery was calculated to be 98.78%.  相似文献   

20.
A Nafion-modified glassy carbon electrode incorporated with tobramycin for the voltammetric stripping determination of Cu2+ has been explored. The electrode was fabricated by tobramycin containing Nafion on the glassy carbon electrode surface. The modified electrode exhibited a significantly increased sensitivity and selectivity for Cu2+ compared with a bare glassy carbon electrode and the Nafion modified electrode. Cu2+ was accumulated in HAc-NaAc buffer (pH 4.6) at a potential of -0.6 V (vs. SCE) for 300 s and then determined by differential pulse anodic stripping voltammetry. The effects of various parameters, such as the mass of Nafion, the concentration of tobramycin, the pH of the medium, the accumulation potential, the accumulation time and the scan rate, were investigated. Under the optimum conditions, a linear calibration graph was obtained in the concentration range of 1.0 x 10(-9) to 5.0 x 10(-7) mol l(-1) with a correlation coefficient of 0.9971. The relative standard deviations for eight successive determinations were 4.3 and 2.9% for 1.0 x 10(-8) and 2.0 x 10(-7) mol l(-1) Cu2+, respectively. The detection limit (three times signal to noise) was 5.0 x 10(-10) mol l(-1). A study of interfering substances was also performed, and the method was applied to the direct determination of copper in water samples, and also in analytical reagent-grade salts with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号