首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Because meningiomas tend to recur after (partial) surgical resection, radiotherapy is increasingly being applied for the treatment of these tumors. Radiation dose levels are limited, however, to avoid radiation damage to the surrounding normal tissue. The radiosensitivity of tumors can be improved by increasing tumor oxygen levels. The aim of this study was to investigate if breathing a hyperoxic hypercapnic gas mixture could improve the oxygenation of meningiomas. Blood oxygen level-dependent magnetic resonance imaging and dynamic Gadolinium (Gd)-DTPA contrast-enhanced MRI were used to assess changes in tumor blood oxygenation and vascularity, respectively. Ten meningioma patients were each studied twice; without and with breathing a gas mixture consisting of 2% CO(2) and 98% O(2). Values of T(2)* and the Gd-DTPA uptake rate k(ep) were calculated under both conditions. In six tumors a significant increase in the value of T(2)* in the tumor was found, suggesting an improved tumor blood oxygenation, which exceeded the effect in normal brain tissue. Contrarily, two tumors showed a significant T(2)* decrease. The change in T(2)* was found to correlate with both k(ep) and with the change in k(ep). The presence of both vascular effects and oxygenation effects and the heterogeneous response to hypercapnic hyperoxia necessitates individual assessment of the effects of breathing a hyperoxic hypercapnic gas mixture on meningiomas. Thus, the current MRI protocol may assist in radiation treatment selection for patients with meningiomas.  相似文献   

2.
In dynamic susceptibility contrast MRI, the shape of the arterial input function (AIF) is commonly obtained in the near vicinity of the middle cerebral artery (MCA). However, the tissue regions where the AIF is sampled also have significant perfusion, which contributes to T(2)* changes. We investigate whether correction of this effect will introduce significant changes in the measurement of the AIF and, subsequently, the assessment of the mean transit time (MTT). Clinical dynamic susceptibility data from 13 patients with brain tumors were analyzed. Patients received either single or double doses of Magnevist followed by a saline flush through a power injector. In the correction procedure, DeltaR(2)* was sampled in a region of gray matter approximately 1-2 cm away from the MCA and then subtracted from the DeltaR(2)* sampled in the immediate vicinity of the MCA. We demonstrate that in the brain, this correction of DeltaR(2)* due to tissue perfusion leads to a narrower width of the AIF curve obtained with DeltaR(2)* (mean+/-S.D.=7.3+/-2.0 and 6.4+/-1.7 s, before and after correction, respectively, P<.001 using a two-tailed paired t-test). Furthermore, the peak of the AIF also moved to a slightly earlier time relative to the time of arrival (mean+/-S.D.=4.7+/-0.9 and 4.3+/-0.8 s, before and after correction, with P<.001). With the use of the corrected AIF, the measured MTT had increased values in areas of both gray and white matter.  相似文献   

3.
The amplitudes of gradient-echoes produced using static field gradients are sensitive to diffusion of tissue water during the echo evolution time. Gradient-echoes have been used to produce MR images in which image intensity is proportional to the self-diffusion coefficient of water. However, such measurements are subject to error due to the presence of background magnetic field gradients caused by variations in local magnetic susceptibility. These local gradients add to the applied gradients. The use of radiofrequency (RF) gradients to produce gradient-echoes may avoid this problem. The RF magnetic field is orthogonal to the offset field produced by local magnetic susceptibility gradients. Thus, the effect of the local gradients on RF gradient-echo amplitude is small if the RF field is strong enough to minimize resonance offset effects. The effects of susceptibility gradients can be further reduced by storing magnetization longitudinally during the echo evolution period. A water phantom was used to evaluate the effects of background gradients on the amplitudes of RF gradient-echoes. A surface coil was used to produce an RF gradient of between 1.3 and 1.6 gauss/cm. Gradient-echoes were detected with and without a 0.16 gauss/cm static magnetic field gradient applied along the same direction as the RF gradient. The background static field gradient had no significant effect on the decay of RF gradient-echo amplitude as a function of echo evolution time. In contrast, the effect of the background gradient on echoes produced using a 1.6 gauss/cm static field gradient is calculated to be significant. This analysis suggests that RF gradient-echoes can produce MR images in which signal intensity is a function of the self-diffusion coefficient of water, but is not significantly affected by background gradients.  相似文献   

4.
We investigated the effects of transcranial magnetic stimulation (TMS) coils and electroencephalographic (EEG) electrodes on T(2)*-weighted echo-planar images (EPI) at 2.0 T (gradient-echo EPI, mean TE = 53 ms, 2x2x4 mm(3)). In comparison with anatomic gradient-echo images (3D FLASH, TE = 4 ms, 1x1x1 mm(3)), T(2)*-weighted EPI acquisitions of a water-filled spherical phantom revealed severe signal losses and geometric distortions in the vicinity of TMS coils. Even remote effects were observed for image orientations perpendicular to the coil plane. EEG electrodes and the fixation gel caused milder localized distortions. In humans, complications were avoided by the large distance between the TMS coil and the cortical surface and when using an EPI orientation parallel to the plane of the coil. It is concluded that T(2)*-weighted EPI studies of human brain function may be performed without distortions caused by TMS coils and EEG electrodes.  相似文献   

5.
We report a case of multiple hemorrhagic cerebral metastases from papillary thyroid cancer, with reference to T(2)*-weighted gradient echo (GRE) magnetic resonance imaging (MRI). Small metastatic nodules were recognized as round nodules with signal loss on T(2)*-weighted GRE MRI, and were more pronounced compared with other sequences. Lesions were later confirmed as hemorrhagic on T(1)- and T(2)-weighted MRI. T(2)*-weighted GRE MRI was a sensitive tool for early detection of metastases displaying hemorrhagic changes.  相似文献   

6.
Comparison of multi-echo spiral and echo planar imaging in functional MRI   总被引:2,自引:0,他引:2  
Multi-echo spiral and echo-planar (EPI) imaging sequences were compared in functional imaging experiments at 3 Tesla. Both sequence types allow calculation of the effective transversal relaxation time T(2)* and the initial signal intensity I(0). These parameters can be used in evaluation of the functional signal with respect to inflow effects and other vascular sources. Prior to functional magnetic resonance imaging (fMRI) experiments T(2)* measurements in the human brain were performed with single- and multi-echo FLASH (fast low angle shot) and compared with EPI und spiral imaging sequences. These experiments resulted in T(2)* values ranging from 42.9 to 53.8 ms in a ROI including white and gray matter and CSF in a prefrontal brain region, and allowed validation of the quantitative results of the fast single-shot techniques. In functional experiments with motor stimulation mean absolute T(2)* increases during stimulation of 1.1 +/- 0.6 ms and 1.4 +/- 0.9 ms were found with multi-echo EPI and spiral imaging, respectively, averaged over the activated pixels. In addition, absolute T(2)* values and the size of activated areas obtained with both sequences are comparable. In these investigations spiral imaging allowed higher spatial resolution due to more efficient use of available gradient performance.  相似文献   

7.
This study compared two methods, corrected (separation of T(1) and T(2)* effects) and uncorrected, in order to determine the suitability of the perfusion and permeability measures through Delta R(2)* and Delta R(1) analyses. A dynamic susceptibility contrast dual gradient echo (DSC-DGE) was used to image the fixed phantoms and flow phantoms (Sephadex perfusion phantoms and dialyzer phantom for the permeability measurements). The results confirmed that the corrected relaxation rate was linearly proportional to gadolinium-diethyltriamine pentaacetic acid (Gd-DTPA) concentration, whereas the uncorrected relaxation rate did not in the fixed phantom and simulation experiments. For the perfusion measurements, it was found that the correction process was necessary not only for the Delta R(1) time curve but also for the Delta R(2)* time curve analyses. Perfusion could not be measured without correcting the Delta R(2)* time curve. The water volume, which was expressed as the perfusion amount, was found to be closer to the theoretical value when using the corrected Delta R(1) curve in the calculations. However, this may occur in the low concentration of Gd-DTPA in tissue used in this study. For the permeability measurements based on the two-compartment model, the permeability factor (k(ev); e = extravascular, v = vascular) from the outside to the inside of the hollow fibers was greater in the corrected Delta R(1) method than in the uncorrected Delta R(1) method. The differences between the corrected and the uncorrected Delta R(1) values were confirmed by the simulation experiments. In conclusion, this study proposes that the correction for the relaxation rates, Delta R(2)* and Delta R(1), is indispensable in making accurate perfusion and permeability measurements, and that DSC-DGE is a useful method for obtaining information on perfusion and permeability, simultaneously.  相似文献   

8.
PURPOSE: Metallic implants cause enlarged artifacts in magnetic resonance (MR) images at higher magnetic fields, B0, due to their magnetic susceptibility. Interactions of conductive material with radio frequency (RF) pulses also change for higher field strengths, B0, due to the frequency dependence of resonance conditions. Systematic measurements on commercial aneurysm clips and simplified copper models were performed in order to investigate both phenomena at 1.5 and 3 T. MATERIALS AND METHODS: Six different commercial aneurysm clips made of titanium, straight copper wires and bent copper models were examined in Gd-DTPA-doped water. RF-related effects were measured by adapted 2D and 3D spin-echo sequences. For reliable differentiation from susceptibility-related effects, variable transmitter voltages were applied. In addition, RF-induced heating was controlled by an infrared (IR) camera. RESULTS: At 3 T, a significant RF-induced electric response could be demonstrated for the copper samples and more moderate for one of the commercial clips, dependent on the geometrical structure determining possible resonant RF coupling. Related RF effects could be distinguished from susceptibility artifacts: a signal enhancement at reduced transmitter voltages indicated locally amplified B1-field amplitudes. No significant heating effect could be measured by IR measurements. CONCLUSION: MR imaging was used to analyze possible RF-induced effects. At 3 T, resonant RF coupling even of small metallic implants has to be considered carefully. Despite a local enhancement of the RF amplitude, no significant RF-induced heating inside the surrounding fluid was found. A direct thermal endangering of patients seems to be unlikely, but extremely high B1-field amplitudes might occur adjacent to the metallic surface with potential nonthermal affection of tissue.  相似文献   

9.
In magnetic resonance imaging (MRI), T(2)(*)-weighted contrast is significantly enhanced by extremely high magnetic field strength, offering broad potential applications. However, the T(2)(*)-weighted image contrast distortion and signal loss artifact arising from discontinuities of magnetic susceptibility within and around the sample are also increased, limiting utilization of high field systems for T(2)(*)-weighted contrast applications. Due to the B(0) dependence of the contrast distortions and signal losses, and the heterogeneity of magnetic susceptibility in biological samples, magnetic susceptibility artifacts worsen dramatically for in vivo microimaging at higher fields. Practical applications of T(2)(*)-sensitive techniques enhanced by higher magnetic fields are therefore challenged. This report shows that magnetic susceptibility artifacts dominate T(2)(*)-weighted image contrast at 14 T, and demonstrates that the GESEPI (gradient echo slice excitation profile imaging) technique effectively reduces or eliminates these artifacts at long TE in the highest field (14 T) currently available for (1)H imaging.  相似文献   

10.
Usual ferroelectric compounds undergo a paraelectric-to-ferroelectric phase transition when the susceptibility of the electric polarization density changes its sign. The temperature is the only thermodynamic field that governs the phase transition. Chiral tilted smectics may also present an improper ferroelectricity when there is a tilt angle between the average long axis direction and the layer normal. The tilt angle is the order parameter of the phase transition which is governed by the temperature. Although the electric susceptibility remains positive, a polarization proportional to the tilt appears due to their linear coupling allowed by the chiral symmetry. Further complications come in when the chirality increases, as new phases are encountered with the same tilt inside the layers but a distribution of the azimuthal direction which is periodic with a unit cell of two (SmC(A)*, three (SmC(Fi1)*, four (SmC(Fi2)* or more (SmC(alpha)* layers. In most of these phases, the layer normal is a symmetry axis so there is no macroscopic polarization except for the SmC(Fi1)* in which the average long axis is tilted so the phase is ferrielectric. By studying a particular compound with only a SmC(Fi2)* and a SmC(alpha)* phase, we show that we recover the uniformly tilted ferroelectric SmC* when applying an electric field. We are thus led to build field-temperature phase diagrams for this class of compounds by combining different experimental techniques described here.  相似文献   

11.
Nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) have been applied to visualize physiological phenomena in plants and agricultural crops. Imaging sequences that result in contrast of a combination of parameters (e.g., proton density, ) cannot be used for a correct and unique interpretation of the results. In this study multiecho imaging together with monoexponential T2 decay fitting was applied to determine reliable proton density and T2 distributions over a mushroom. This was done at three magnetic field strengths (9.4, 4.7, and 0.47 T) because susceptibility inhomogeneities were suspected to influence the T2 relaxation times negatively, and because the inflences of susceptibility inhomogeneities increase with a rise in magnetic field strength. Electron microscopy was used to understand the different T2's for the various tissue types in mushrooms. Large influences of the tissue ultrastructure on the observed T2 relaxation times were found and explained. Based on the results, it is concluded that imaging mushrooms at low fields (around or below 0.47T) and short echo times has strong advantages over its high-field counterpart, especially with respect to quantitative imaging of the water balance of mushrooms. These conclusions indicate general validity whenever NMR imaging contrast is influenced by susceptibility inhomogeneities.  相似文献   

12.
Photoinduced magnetization in a magnet based on organic species is reported for the first time. Upon optical excitation in the blue region of spectrum, Mn(tetracyanoethylene)(x)*y(CH2Cl2) (x approximately 2, y is approximately 0.8) exhibits increased magnetic susceptibility at temperatures as high as 75 K, accompanied with photoinduced absorption in the visible and infrared spectral regions. These effects are partially reversible by lower energy visible light and fully reversible by thermal treatment. The results suggest trapping of the photoexcited charge in a metastable state with enhanced exchange interaction.  相似文献   

13.
The purpose was to analyse magnetic susceptibility effects on accuracy of point-wise measurements of signal profiles in the assessment of MRS volume selection performance. An existing phantom design consisting of a sphere with a movable signal source was used for the investigation. The influence from the phantom on magnetic field homogeneity was measured with phase sensitive 1H imaging and 31P spectroscopy on a 1.5 T whole body MR system. The susceptibility effects for such a phantom design can be separated in 1/ A variation in the background magnetic field, which is caused by the stationary structures and has a significant influence on spatial accuracy. 2/ A magnetic field distortion, which is caused by the movable signal source and has very little influence on accuracy. The spatial inaccuracy due to susceptibility effects in this phantom, was 0.03 mm for positions of the signal source covering a 40-mm VOI. Susceptibility effects from the movable signal source were substantial but had very little influence on spatial accuracy. Still, improvements of this phantom design are possible. Point-wise measurements using a phantom with a movable signal source is inherently insensitive to susceptibility effects from the signal source and permits accurate signal profile measurements of high spatial (sub-mm) resolution.  相似文献   

14.
ZnCu(3)(OH)(6)Cl(2) (S=1/2) is a promising new candidate for an ideal Kagome Heisenberg antiferromagnet, because there is no magnetic phase transition down to approximately 50 mK. We investigated its local magnetic and lattice environments with NMR techniques. We demonstrate that the intrinsic local spin susceptibility decreases toward T=0, but that slow freezing of the lattice near approximately 50 K, presumably associated with OH bonds, contributes to a large increase of local spin susceptibility and its distribution. Spin dynamics near T=0 obey a power-law behavior in high magnetic fields.  相似文献   

15.
High-spatial-resolution acquisition (HR) was previously proposed for 3D echo-planar spectroscopic imaging (EPSI) in combination with a high-spatial-resolution water reference EPSI data set to minimize inhomogeneous spectral line broadening, allowing for local frequency shift (B(0) shift) correction in human brain metabolite maps at 1.5 T (Ebel A et al., Magn. Reson. Imaging 21:113-120, 2003). At a higher magnetic field strength, B(0), increased field inhomogeneities typically lead to increased line broadening. Additionally, increased susceptibility variations render shimming of the main magnetic field over the whole head more difficult. This study addressed the question whether local B(0)-shift correction still helps limit line broadening in whole-brain 3D EPSI at higher magnetic fields. The combination of HR and local B(0)-shift correction to limit line broadening was evaluated at 4 T. Similar to the results at 1.5 T, the approach provided a high yield of voxels with good spectral quality for 3D EPSI, resulting in improved brain coverage.  相似文献   

16.
The magnetic properties of layered hydroxylammonium fluorocobaltate (NH(3)OH)(2)CoF(4) were investigated by measuring its dc magnetic susceptibility in zero-field-cooled (ZFC) and field-cooled (FC) regimes, its frequency dependent ac susceptibility, its isothermal magnetization curves after ZFC and FC regimes, and its heat capacity. Effects of pressure and magnetic field on magnetic phase transitions were studied by susceptibility and heat capacity measurements, respectively. The system undergoes a magnetic phase transition from a paramagnetic state to a canted antiferromagnetic state exhibiting a weak ferromagnetic behavior at T(C) = 46.5 K and an antiferromagnetic transition at T(N) = 2.9 K. The most spectacular manifestation of the complex magnetic behavior in this system is a shift of the isothermal magnetization hysteresis loop in a temperature range below 20 K after the FC regime-an exchange bias phenomenon. We investigated the exchange bias as a function of the magnetic field during cooling and as a function of temperature. The observed exchange bias was attributed to the large exchange anisotropy which exists due to the quasi-2D structure of the layered (NH(3)OH)(2)CoF(4) material.  相似文献   

17.
An increasing number of lab-on-a-chip devices require advanced fluid manipulations. We intend to address this requirement by incorporating polymeric responsive materials on the walls of the microfluidic channels of such devices. In this paper we present a magnetic polymer made from commercially available functionalized magnetic nanoparticles and PDMS. Loadings of this polymer up to 5% volume of magnetic material were achieved. We report on the Young's modulus of this material and describe its magnetization behavior with a combination of inter-particle interaction and particle cluster demagnetization effects. The magnetic polymer can have a magnetic susceptibility up to 0.5 and by curing in a magnetic field, a magnetic anisotropy of a factor 2 in susceptibility can be created. Finally, a finite element model simulation is performed to quantify the amplitude of motion of a microstructure made of this magnetic polymer, and the local magnetic actuation with a current running in a micro-fabricated wire is discussed.  相似文献   

18.
The Zeeman effect on the crystal electric field (CEF) magnetic susceptibility in 4f-electron singlet ground state (SGS) systems is studied analytically in the framework of the molecular-field model and experimentally by measuring the magnetic susceptibility of SGS compound PrNi5. The most striking result of the analysis is the shift of the zero-field magnetic susceptibility maximum to lower temperatures in magnetic field. This thoroughly CEF effect is a direct consequence of the convergence of the SGS and the low lying Zeeman branch of the first excited state in an applied magnetic field. The observed shift of the susceptibility maximum from 14 K to 9 K in polycrystalline PrNi5 by applying a magnetic field of 9T confirms the foregone conclusion.  相似文献   

19.
Single crystals of the new ternary compound Ce(2)Ga(12)Pt were prepared by the self-flux technique. The crystal structure with the space group P4/nbm was established from single crystal x-ray diffraction data and presents a derivative of the LaGa(6)Ni(0.6) prototype. Magnetic susceptibility measurements show Curie-Weiss behaviour due to local Ce(3+) moments. At high temperatures, the magnetic anisotropy is dominated by the crystal-electric-field (CEF) effect with the easy axis along the crystallographic c direction. Ce(2)Ga(12)Pt undergoes two antiferromagnetic phase transitions at T(N,1) = 7.3 K and T(N,2) = 5.5 K and presents several metamagnetic transitions for the magnetic field along c. Specific-heat measurements prove the bulk nature of these magnetic transitions and reveal a doublet CEF ground state. The 4f contribution to the resistivity shows a broad maximum at T(max) ≈ 85 K due to Kondo scattering off the CEF ground state and excited levels.  相似文献   

20.
In this work, computer modeling based on a finite element method is used to simulate the T2* relaxation of hyperpolarized noble gases (HNG) in the lungs. A physical model of lung airways consisting of a phantom constructed from micro-capillary fibers of diameters similar to the size of lung airways with semi-permeable walls is also presented. The fibers are surrounded by a liquid medium (water) of magnetic susceptibility similar to lung tissue. Theoretical predictions of the field strength dependence of T2* for 129Xe in the phantom and in vivo rat lung are presented. These predictions are in good agreement with experimental T2* values obtained from the phantoms and in vivo rat lungs (160, 19 and 8 ms) at three different field strengths (0.074, 1.89 and 3T, respectively) using hyperpolarized 129Xe. The strong dependence of T2* on field strength is consistent with the theoretical prediction that low fields may be optimal for HNG MR imaging of the lungs as the decreased T2* at high fields necessitates an increase in bandwidth for conventional MR imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号