首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chen  Shizhong  Cheng  Xiuli  He  Yuanyuan  Zhu  Shengping  Lu  Dengbo 《Mikrochimica acta》2013,180(15):1479-1486

We have developed a method for the determination of trace levels of the rare earth elements La, Eu, and Yb in biological and environmental samples. It is based on solidified floating organic drop microextraction using 1-(2-pyridylazo)-2-naphthol (PAN) as a chelator, followed by electrothermal vaporization (ETV) and quantification by inductively coupled plasma mass spectrometry. PAN also acts as a modifier in ETV. The effects of pH, amount of PAN, extraction time, stirring rate, volume of sample solution, and temperature program were examined. Under optimized conditions, the detection limits are 2.1, 0.65 and 0.91 pg mL−1 for the elements La, Eu and Yb, respectively. The relative standard deviations are <6.0 % (c = 0.1 ng mL−1, n = 9). When applied to the analysis of (spiked) natural water samples, the recoveries range from 92 to 105 %. The accuracy was validated with certified reference materials (combined sample of branch and leaf of shrub: GBW 07603 and human hair: GBW 07601), and the results were in good agreement with the certified values.

►Solidified floating organic drop microextraction was combined with ETV for ICP-MS. ►PAN acted as both a chelating agent and a chemical modifier. ►The method was used for analysis of rare earth elements in real samples. ►The method has the merits of low detection limit, good precision and accuracy.

  相似文献   

2.
We report on the use of hollow fiber liquid-liquid-liquid microextraction (HF-LLLME) followed by corona discharge ion mobility spectrometry for the determination of dextromethorphan and pseudoephedrine in urine and plasma samples. The effects of pH of the donor phase, stirring rate, ionic strength and extraction time on HF-LLLME were optimized. Under the optimized conditions, the linear range of the calibration curves for dextromethorphan in plasma and urine, respectively, are from 1.5 to 150 and from 1 to 100 ng mL?1. The ranges for pseudoephedrine, in turn, are from 30 to 300 and from 20 to 200 ng mL?1. Correlation coefficients are better than 0.9903. The limits of detection are 0.6 and 0.3 ng mL?1 for dextromethorphan, and 8.6 and 4.2 ng mL?1 for pseudoephedrine in plasma and urine samples, respectively. The relative standard deviations range from 6 to 8%.
Figure
Hollow fiber liquid–liquid–liquid microextraction (HF-LLLME) followed by corona discharge ion mobility spectrometry (CD-IMS) was used for the determination of dextromethorphan and pseudoephedrine in urine and plasma samples.  相似文献   

3.
We have developed a simple and efficient method for dispersive liquid-liquid microextraction of 4-nitrophenol, 2-naphthol and bisphenol A in real water samples. It is making use of solidified floating organic droplets of 1-dodecanol which has low density and a proper melting point. The type and volume of extraction solvent and dispersive solvent, the effect of salts, pH value and extraction time were optimized and resulted in enrichment factors of 84 for 4-nitrophenol, 123 for 2-naphthol, and 97 for bisphenol A. The limits of detection by HPLC are 1.50, 0.10 and 1.02 ng · mL?1, respectively. Excellent linearity is observed in the concentration range from 10 to 800 ng · mL?1, with coefficients of correlation ranging from 0.9988 to 0.9999. The relative standard deviations (for n?=?5) are from 3.2 to 5.3 %, and relative recoveries for the three phenols in tap, river and spring water range from 85.0 to 105.0 %, 98.3 to 110.0 %, and 98.6 to 109.0 %, respectively.
Figure
Chromatograms of river water blank (b) and spiked river water (a, 500 ng ? mL?1) analyzed with DLLME-SFO-HPLC. Peak identification: (1) p-nitrophenol; (2) 2-naphthol; (3) bisphenol A. Liquid-liquid microextraction method based on solidification of floating organic droplet (DLLME-SFO) has a high enrichment factor (84, 123and 97), acceptable relative recovery (85.0 %–110.0 %), good repeatability (5.27 %, 3.54 % and 3.16 %) and a wide linear range (10–800 ng · mL?1) for the determination of p-nitrophenol, 2-naphthol and bisphenol A.  相似文献   

4.
We describe a simple, environmentally friendly and selective technique for the determination of ochratoxin A (OTA) in urine. It involves (a) the use of a molecularly imprinted polymer as a sorbent in micro-solid-phase extraction in which the sorbent is contained in a propylene membrane envelope, and (b) separation and detection by capillary electrophoresis (CE). Under optimized conditions, response is linear in the range between 50 and 300 ng mL?1 (with a correlation coefficient of 0.9989), relative standard deviations range from 4 to 8 %, the detection limit for OTA in urine is 11.2 ng mL?1 (with a quantification limits of 32.5 ng mL?1) which is lower than those of previously reported methods for solid-phase extraction combined with CE. The recoveries of OTA from urine spiked at levels of 50, 150 and 300 ng mL?1 ranged from 93 to 97 %.
Figure
?  相似文献   

5.
A method was developed for the determination of cadmium(II) by ligand-less solid phase extraction that is based on the direct retention of Cd(II) in a mini-column filled with a silica gel modified with an amino-functionalized ionic liquid. The effects of pH, sample volume and its flow rate, eluent concentration and its volume, the flow rate of eluent, and of potential interferences on extraction and desorption were optimized. Following its determination by electrothermal atomic absorption spectrometry, the detection limit for Cd(II) is 8.9 ng L?1, and the relative standard deviation is 2.3 % (at 1.0 ng mL?1; for n?=?5). The method was applied to the analysis of Cd(II) in a certified reference material (laver; GBW10023), and the recoveries ranged from 97.0 to104.0 %
Figure
◆ Amino-functionalized ionic liquid modified silica gel (NH2-IL/SG) obtained a better absorption for Cd(II) than bare silica gel in the tested pH range due to electrostatic interaction between amino groups and Cd(II).  相似文献   

6.
We have extracted ten phthalate esters (C1 to C8) using six different micro-scale methods for extraction, and then separated them by capillary liquid chromatography coupled to UV detection. The methods included liquid-liquid extraction, ultrasonic-assisted extraction, microwave-assisted extraction, dispersive liquid-liquidmicroextraction, dispersive liquid-liquid microextraction solidification of floating organic droplets, and cloud point extraction. The linear range of the analytes is from 0.5 to 50 μg mL?1, and the detection limits range from 0.02 to ~0.17 μg mL?1. The precision and accuracy of all intra- and inter-day analyses are <5.5%. We find that dispersive liquid-liquid microextraction solidification of floating organic droplet (DLLME-SFO) is the best method for quantification of most phthalate esters in water samples and cosmetics because of its low limit of detection and high extraction efficiencies.
Figure
Phthalate esters were extracted by six micro-scale extraction methods and then determinated by capillary liquid chromatography coupled with ultraviolet detector (CapLC-UV).  相似文献   

7.
In this research, a mixed immunoassay design for multiple chemical residues detection based on combined reverse competitive enzyme-linked immunosorbent assay (ELISA) procedure was developed. This method integrated two reverse ELISA reactions in one assay by labeling horseradish peroxidase to deoxynivalenol (DON) and orbifloxacin. Within this method, IC50 of the two mAbs for each analyte we produced ranged from 23?~?68 ng?mL?1 for DONs and 4.1?~?49 ng?mL?1 for quinolones (QNs). The limit of detection measured by IC10 was achieved at 0.45–1.3 ng?mL?1 for DONs and 0.59–6.9 ng?mL?1 for QNs, which was lower than the maximum residue levels. Recoveries in negative samples spiked at concentrations of 100, 200, and 500 ng?mL?1 ranged from 91.3 to 102.2 % for DONs and 88.7–98.05 % for QNs with relative standard deviation less than 9.88 and 12.67 %. The results demonstrated that this developed immunoassay was suitable for screening of low molecular weight contaminants.
Figure
Combined reverse ELISA procedure for multi-chemical residues analysis  相似文献   

8.
A method was developed for the determination of gold ion in water samples using microextraction based on the ultrasound-assisted emulsification of solidified floating organic drops, followed by the flame atomic absorption spectrometry. N-(4-{4-[(anilinocarbothioyl)amino]benzyl}phenyl)-N-phenylthiourea was used as chelating agent. The parameters affecting the extraction and complex formation (including the type and volume of the extracting solvent, time of sonication and centrifugation, pH, amount of the chelating agent, and sample ionic strength) were optimized. Under the optimum conditions, the calibration graph is linear in the range from 1.5 to 400 ng mL?1, with a limit of detection of 0.45 ng mL?1. The relative standard deviation for ten replicate determinations of gold ion in a concentration of 175 ng mL?1 was 1.7%. The procedure was successfully applied to the determination of gold in water samples, in pharmaceutical and synthetic samples, and in a standard reference material.
Figa
The schematic procedure of the ultrasound-assisted emulsification solidified floating organic drop microextraction is shown in above figure from A to E.  相似文献   

9.
We describe a method for single drop microextraction of manganese from fish, mollusk, and from natural waters using the reagent 1-(2-pyridylazo)-2-naphthol as the complexing agent and chloroform as the fluid extractor. After extraction, the analyte was directly submitted to graphite furnace electrothermal atomic absorption spectrometry. Once optimized, the method has a detection limit of 30 ng L?1, a limit of quantification of 100 ng L?1, and an enrichment factor of 16. Its accuracy was verified by applying the procedure to the following certified reference materials: apple leaves, spinach leaves, bovine liver, and mussel tissue. The procedure was also successfully applied to the determination of manganese in seafood and natural waters.
Figure
Preconcentration system using single-drop microextraction for the determination of manganese  相似文献   

10.
We report on a novel electrochemiluminescent (ECL) immunoassay for the ultrasensitive determination of morphine by making use of a gold electrode which was modified with a nanocomposite film containing self-assembled polyamidoamine (PAMAM) CdS quantum dots and electrodeposited gold nanoparticles (Au-NPs). The highly uniform and well-dispersed quantum dots were capped with PAMAM dendrimers. Due to the synergistic effect of the modified quantum dots and the electrodeposited Au-NPs, the ECL response is dramatically enhanced. Under optimal experimental conditions, the immunoreaction between morphine and anti-morphine antibody resulted in a decrease of the ECL signal because of steric hindrance. The calibration plot is linear in the morphine concentration range from 0.2 to 180 ng?mL?1, with a detection limit as low as 67 pg?mL?1. The sensor was successfully applied to the determination of morphine in blood plasma. This kind of assay is expected to pave new avenues in label-free drug assays.
Figure
?  相似文献   

11.
The anti-schizophrenic drug risperidone (RSP) exerts an inhibitory effect on the chemiluminescence (CL) of the luminol-lysozyme system. This finding forms the basis for a sensitive flow injection method for its determination at picogram levels. RSP binds to Trp62 in the lysozyme, and this leads to a conformational change upon which the CL of the system is quenched. The decrease in CL is proportional to the logarithm of the concentration of RSP, and the calibration graph is linear in the range from 0.1 pg?mL?1 to 1.0 ng?mL?1, with relative standard deviations of <5.0%, and a detection limit of 0.05 pg?mL?1 (3σ). At a flow rate of 2.0 mL?min?1, the whole process including sampling and washing is completed within 20 s. The method was successfully applied to monitoring RSP in human urine after incorporation of 2 mg of RSP, with a total excretion of 16.6% within 8.5 h.
Figure
The reaction of lysozyme with risperidone using luminol as luminescence reagent by the luminol-lysozyme FI-CL system and its application.  相似文献   

12.
We report on a multiplex bead-based competitive immunoassay using suspension array technology for the simultaneous detection of the pesticides triazophos, carbofuran and chlorpyrifos. Three hapten-protein conjugates were covalently bound to carboxylated fluorescent microspheres to serve as probes. The amount of conjugates and antibodies were optimized. The new multi-analyte assay has dynamic ranges of 0.02–50 ng?mL?1, 0.5–500 ng?mL?1 and 1.0–1000 ng?mL?1 for triazophos, carbofuran and chlorpyrifos, respectively, and the detection limits are 0.024, 0.93 and 1.68 ng?mL?1. This new multiplex assay is superior to the traditional ELISA in possessing a wider detection range, better reproducibility and the feature of multi-target detection. Cross-reactivity studies indicated that the bead-array method is highly selective for the three target pesticides, and that individual analyses have no significant influence between each other, also without cross-reactions from other structurally related pesticides. The method was applied to analyze vegetables spiked with the three pesticides, and the recoveries were in ranges of 78.5–112.1 %, 72.2–120.2 % and 70.2–112.8 %, respectively, with mean coefficients of variation of <15 %.
Figure
Schematic illustration of the multiplex bead-based competitive immunoassay  相似文献   

13.
We describe a new method for differential-pulse anodic stripping voltammetric determination of thallium(I) using a carbon paste electrode modified with dicyclohexyl-18-crown-6. The effect of supporting electrolyte (type and pH), accumulation and reduction potential, and of time and amount of modifier were investigated by differential pulse anodic stripping voltammetry. A method was then worked out for the determination of thallium at low levels. Under optimized conditions, the response to Tl(I) is linear in the range from 3.0 to 250 ng mL?1. The detection limit is 0.86 ng mL?1. The sensor displays good repeatability (with a relative standard deviation of ±2.70 % for n?=?7) and was applied to the determination of Tl(I) in water, hair samples, and certified reference materials.
Figure
Crown ethers allow only some ions to entry and complex formation that their sizes equal to ether cavity.  相似文献   

14.
We describe a simple and rapid method for the ultrasound-assisted microextraction of antimony using the solidified floating organic drop method. The effects of pH, type and volume of the extractant, time of sonication, amount of chelating agent, type and amount of surfactant were investigated and optimized. Bromopyrogollol red is acting as the chelating agent. Antimony(III) ion was extracted into finely dispersed droplets of undecanol after ion-pair formation with the water soluble chelator and the cationic detergent benzyldimethyltetradecylammonium chloride. Flame atomic absorption spectrometry was used for the detection. The resulting calibration is linear in the concentration range from 4.0 to 900?ng?mL-1 of Sb(III) with a correlation coefficient of 0.9981. The enrichment factor is 67, the detection limit is 0.62?ng?mL-1, and the relative standard deviation is?±?3.6% (at 100?ng?mL-1; for n?=?10). The method was successfully applied to the determination of antimony in water samples.
Figure
Antimony and many of its compounds are toxic and can damage the kidneys and the liver, causing death in a few days. Concentration of this element is very low in nature and hence their determination required sensitive analytical techniques. One such technique is an ultrasound assisted emulsification microextraction procedure.  相似文献   

15.
We describe a method for ionic liquid based dispersive liquid-liquid microextraction of Co(II), Cu(II), Mn(II), Ni(II) and Zn(II), followed by their determination via flow injection inductively coupled plasma optical emission spectrometry. The method is making use of the complexing agent 1-(2-thenoyl)-3,3,3-trifluoracetone, the ionic liquid 1-hexyl-3-methyl imidazolium bis(trifluoromethylsulfonyl)imide, and of ethanol as the dispersing solvent. After extraction and preconcentration, the sedimented ionic liquid (containing the target analytes) is collected, diluted with 1-propanol, and introduced to the ICP-OES. Effects of pH, ionic strength, ligand to metal molar ratio, volumes of extraction and disperser solvents on the performance of the microextraction were optimized in a half-fractional factorial design. The significant parameters were optimized using a face-centered central composite design. The method has detection limits between 0.10 and 0.20?ng?mL?1 of the metal ions, preconcentration factors between 79 and 102, linear responses in 0.25 to 200?ng?mL?1 concentration ranges, and relative standard deviations of 3.4 to 6.0%. The method was successfully applied to the analysis of drinking water, a fish farming pond water, and waste water from an industrial complex.
Figure
Ionic liquid based dispersive liquid-liquid microextraction of Co, Cu, Mn, Ni and Zn followed by determination via flow injection inductively coupled plasma optical emission spectrometry  相似文献   

16.
We describe a silver(I)-selective carbon paste electrode modified with multi-walled carbon nanotubes and a silver-chelating Schiff base, and its electrochemical response to Ag(I). Effects of reduction potential and time, accumulation time, pH of the solution and the stripping medium were studied by differential pulse anodic stripping voltammetry and optimized. The findings resulted in a method for the determination of silver over a linear response range (from 0.5 to 235 ng?mL?1) and with a detection limit as low as 0.08 ng?mL?1. The sensor displays good repeatability (with the RSD of ±?2.75 % for 7 replicates) and was applied to the determination of Ag(I) in water samples and X-ray photographic films.
Figure
Open circuit accumulation of Ag(I) onto a surface of EHPO-MCPE and determination by Differential pulse anodic stripping voltammetry  相似文献   

17.
We have used a nano-structured nickel-aluminum layered double hydroxide (Ni-Al LDH) for the extraction of trace levels of selenium prior to its determination by continuous-flow hydride generation atomic absorption spectrometry. Extraction is based on the adsorption of Se(IV) anions on the Ni-Al-nitrate LDH, and/or their exchange with the nitrate anions in the LDH interlayer. The effects of pH value, amount of nanosorbent, eluent type and concentration, sample volume and flow rate were optimized. No appreciable matrix effects were observed. Under optimum conditions, the limit of detection (defined as three times the standard deviation of the blank signal divided by the slope of the calibration plot) is 10 pg?mL?1, and the relative standard deviation is 2.8 %. The sorption capacity and preconcentration factor are 10 mg?g?1 and 33, respectively. The method was successfully applied to the determination of Se(IV) in tap water, river water, well water, wastewater and oyster tissue (certified reference material, CRM 1566b).
Figure
Effect of NaOH concentration on elution of the retained Se(IV) ions from solid phase extraction column containing nickel-aluminum-nitrate layered double hydroxide nano-sorbent is shown. Combination of the sample preparation procedure with continuous flow hydride generation AAS exhibited excellent selectivity and sensitivity that could be exploited in determination of Se(IV) in various complicated matrices.  相似文献   

18.
We describe a nanometer sized composite material made from titanium dioxide and silica that was chemically modified with 4-aminophenylarsonic acid and used for selective solid-phase extraction, separation and preconcentration of of aluminum(III) prior to its determination by ICP-OES. Under optimized conditions, the static adsorption capacity is 56.58?mg?g?1, the enrichment factor is 150, the relative standard deviation is 1.6% (for n?=?11), and the detection limit (3?s) is 60?pg?mL?1. The method was validated by analyzing the reference materials GBW 09101 (hair) and GBW 10024 (scallop) and successfully applied to the determination of trace Al(III) in spiked water samples and human urine, with recoveries ranging from 96% to 101%.
Figure
4-aminophenylarsonic acid modified nanometer TiO2/SiO2 composite material has been developed to separate and concentrate trace Al(III) from aqueous samples. Parameters that affect the sorption and elution efficiency were studied in column mode, and the new adsorbent presents high selectivity and adsorption capacity for the solid phase extraction of trace Al(III).  相似文献   

19.
We report on a fast, simple and accurate method for the determination of proline in urine samples by employing a nanostructured film of conducting polypyrrole for electrochemically controlled solid-phase microextraction, and ion mobility spectrometry (IMS) for detection. This method has the advantages of simple sample preparation and a sensitivity of IMS to proline that is higher than that for other amino acids. The calibration curve is linear in the range of 0.5–60 μg L?1 (4–521 nmol L?1), and the detection limit is 0.2 μg L?1. The electrochemical potentials for uptake and release were optimized. The method was successfully applied to the clean-up and quantitation of trace amounts of proline in urine samples.
Figure
Proline determination by electrochemically controlled solid phase microextraction coupled to ion mobility spectrometry  相似文献   

20.
A novel test has been developed for the analysis of methadone in dried blood spot specimens from patients undergoing methadone maintenance treatment. An isocratic reversed-phase high-performance liquid chromatography method with coulometric detection has been optimized for the determination of methadone. The clean-up of dried blood spots was performed by means of an original microextraction by packed sorbent procedure after microwave-assisted extraction of the drug with a suitable solvent. Extraction yields were satisfactory, always being higher than 90.0 %. The calibration curve was linear over the 4–500 ng mL-1 concentration range. The method had satisfactory sensitivity (limit of quantitation of 4 ng mL-1), precision (relative standard deviation less than 5.8 %), selectivity and accuracy (recovery greater than 87.0 %). It was successfully applied to dried blood spot samples collected from heroin-addicted patients undergoing methadone maintenance therapy at dosages between 40 and 240 mg day-1. The statistical analysis (Bland–Altman plot) showed that the results were in good agreement with those found from the analysis of plasma samples obtained from the same patients. Thus, the method has proved to be suitable for the monitoring of methadone by means of dried blood spots.
Figure
Bland-Altman plot and methadone disposition in patients undergoing methadone maintenance treatment  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号