首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Li MW  Martin RS 《The Analyst》2008,133(10):1358-1366
In this paper, we describe the fabrication and evaluation of a multilayer microchip device that can be used to quantitatively measure the amount of catecholamines released from PC 12 cells immobilized within the same device. This approach allows immobilized cells to be stimulated on-chip and, through rapid actuation of integrated microvalves, the products released from the cells are repeatedly injected into the electrophoresis portion of the microchip, where the analytes are separated based upon mass and charge and detected through post-column derivatization and fluorescence detection. Following optimization of the post-column derivatization detection scheme (using naphthalene-2,3-dicarboxaldehyde and 2-beta-mercaptoethanol), off-chip cell stimulation experiments were performed to demonstrate the ability of this device to detect dopamine from a population of PC 12 cells. The final 3-dimensional device that integrates an immobilized PC 12 cell reactor with the bilayer continuous flow sampling/electrophoresis microchip was used to continuously monitor the on-chip stimulated release of dopamine from PC 12 cells. Similar dopamine release was seen when stimulating on-chip versus off-chip yet the on-chip immobilization studies could be carried out with 500 times fewer cells in a much reduced volume. While this paper is focused on PC 12 cells and neurotransmitter analysis, the final device is a general analytical tool that is amenable to the immobilization of a variety of cell lines and analysis of various released analytes by electrophoretic means.  相似文献   

2.
微流控分析芯片的网络结构和微米通道尺寸适合于单细胞进样、控制和分离分析[1~4].在测定细胞内容物时,大多采用柱前细胞内衍生法[1,2,4],但操作复杂,需多次离心分离,且能透过细胞膜标记胞内组分的荧光试剂较少.  相似文献   

3.
微流控芯片NDA在线衍生测定单细胞中谷胱甘肽   总被引:3,自引:0,他引:3  
单细胞分析对研究细胞内信号传递和重大疾病的早期诊断等具有重要意义,荧光标记是检测细胞内物质的常用技术,为防止衍生时的过度稀释,大多采用柱前细胞内衍生法,衍生后再用微流控芯片分析,此法操作复杂,需多次离心分离,且能透过细胞膜标记胞内组分的荧光试剂较少。  相似文献   

4.
The controlled self-assembly of polymer-stabilized quantum dots (QDs) into mesoscale aqueous spherical assemblies using microfluidics is described. In a flow-focusing configuration, self-assembly is initiated by the addition of water to a blended solution of polystyrene-coated QDs and amphiphilic polystyrene-block-poly(acrylic acid) stabilizing chains and terminated in a downstream quench step. The on-chip evolution of assemblies is monitored through fluorescence microscopy, and particle size distributions are determined off-chip by transmission electron microscopy. On-chip size control of the assemblies is demonstrated via both the average water concentration in the channel and the flow rate.  相似文献   

5.
Novel latching microfluidic valve structures are developed, characterized, and controlled independently using an on-chip pneumatic demultiplexer. These structures are based on pneumatic monolithic membrane valves and depend upon their normally-closed nature. Latching valves consisting of both three- and four-valve circuits are demonstrated. Vacuum or pressure pulses as short as 120 ms are adequate to hold these latching valves open or closed for several minutes. In addition, an on-chip demultiplexer is demonstrated that requires only n pneumatic inputs to control 2(n-1) independent latching valves. These structures can reduce the size, power consumption, and cost of microfluidic analysis devices by decreasing the number of off-chip controllers. Since these valve assemblies can form the standard logic gates familiar in electronic circuit design, they should be useful in developing complex pneumatic circuits.  相似文献   

6.
Li MW  Martin RS 《Electrophoresis》2007,28(14):2478-2488
Here we describe a reversibly sealed microchip device that incorporates poly(dimethylsiloxane) (PDMS)-based valves for the rapid injection of analytes from a continuously flowing stream into a channel network for analysis with microchip electrophoresis. The microchip was reversibly sealed to a PDMS-coated glass substrate and microbore tubing was used for the introduction of gas and fluids to the microchip device. Two pneumatic valves were incorporated into the design and actuated on the order of hundreds of milliseconds, allowing analyte from a continuously flowing sampling stream to be injected into an electrophoresis separation channel. The device was characterized in terms of the valve actuation time and pushback voltage. It was also found that the addition of sodium dodecyl sulfate (SDS) to the buffer system greatly increased the reproducibility of the injection scheme and enabled the analysis of amino acids derivatized with naphthalene-2,3-dicarboxaldehyde/cyanide. Results from continuous injections of a 0.39 nL fluorescein plug into the optimized system showed that the injection process was reproducible (RSD of 0.7%, n = 10). Studies also showed that the device was capable of monitoring off-chip changes in concentration with a device lag time of 90 s. Finally, the ability of the device to rapidly monitor on-chip concentration changes was demonstrated by continually sampling from an analyte plug that was derivatized upstream from the electrophoresis/continuous flow interface. A reversibly sealed device of this type will be useful for the continuous monitoring and analysis of processes that occur either off-chip (such as microdialysis sampling) or on-chip from other integrated functions.  相似文献   

7.
This work demonstrates the detection of E. coli using a 2-dimensional photosensor array biochip which is efficiently equipped with a microfluidics sample/reagent delivery system for on-chip monitoring of bioassays. The biochip features a 4 x 4 array of independently operating photodiodes that are integrated along with amplifiers, discriminators and logic circuitry on a single platform. The microfluidics system includes a single 0.4 mL reaction chamber which houses a sampling platform that selectively captures detection probes from a sample through the use of immobilized bioreceptors. The independently operating photodiodes allow simultaneous monitoring of multiple samples. In this study the sampling platform is a cellulosic membrane that is exposed to E. coli organisms and subsequently analyzed using a sandwich immunoassay involving a Cy5-labeled antibody probe. The combined effectiveness of the integrated circuit (IC) biochip and the immunoassay is evaluated for assays performed both by conventional laboratory means followed by detection with the IC biochip, and through the use of the microfluidics system for on-chip detection. Highlights of the studies show that the biochip has a linear dynamic range of three orders of magnitude observed for conventional assays, and can detect 20 E. coli organisms. Selective detection of E. coli in a complex medium, milk diluent, is also reported for both off-chip and on-chip assays.  相似文献   

8.
In vitro derived simplified 3D representations of human organs or organ functionalities are predicted to play a major role in disease modeling, drug development, and personalized medicine, as they complement traditional cell line approaches and animal models. The cells for 3D organ representations may be derived from primary tissues, embryonic stem cells or induced pluripotent stem cells and come in a variety of formats from aggregates of individual or mixed cell types, self-organizing in vitro developed “organoids” and tissue mimicking chips. Microfluidic devices that allow long-term maintenance and combination with other tissues, cells or organoids are commonly referred to as “microphysiological” or “organ-on-a-chip” systems. Organ-on-a-chip technology allows a broad range of “on-chip” and “off-chip” analytical techniques, whereby “on-chip” techniques offer the possibility of real time tracking and analysis. In the rapidly expanding tool kit for real time analytical assays, mass spectrometry, combined with “on-chip” electrophoresis, and other separation approaches offer attractive emerging tools. In this review, we provide an overview of current 3D cell culture models, a compendium of current analytical strategies, and we make a case for new approaches for integrating separation science and mass spectrometry in this rapidly expanding research field.  相似文献   

9.
This work demonstrates the detection of E. coli using a 2-dimensional photosensor array biochip which is efficiently equipped with a microfluidics sample/reagent delivery system for on-chip monitoring of bioassays. The biochip features a 4 × 4 array of independently operating photodiodes that are integrated along with amplifiers, discriminators and logic circuitry on a single platform. The microfluidics system includes a single 0.4 mL reaction chamber which houses a sampling platform that selectively captures detection probes from a sample through the use of immobilized bioreceptors. The independently operating photodiodes allow simultaneous monitoring of multiple samples. In this study the sampling platform is a cellulosic membrane that is exposed to E. coli organisms and subsequently analyzed using a sandwich immunoassay involving a Cy5-labeled antibody probe. The combined effectiveness of the integrated circuit (IC) biochip and the immunoassay is evaluated for assays performed both by conventional laboratory means followed by detection with the IC biochip, and through the use of the microfluidics system for on-chip detection. Highlights of the studies show that the biochip has a linear dynamic range of three orders of magnitude observed for conventional assays, and can detect 20 E. coli organisms. Selective detection of E. coli in a complex medium, milk diluent, is also reported for both off-chip and on-chip assays. Received: 13 October 2000 / Revised: 13 November 2000 / Accepted: 13 November 2000  相似文献   

10.
Ion chromatography on-chip   总被引:3,自引:0,他引:3  
On-chip separation of inorganic anions by ion-exchange chromatography was realized. Micro separation channels were fabricated on a silicon wafer and sealed with a Pyrex cover plate using standard photolithography, wet and dry chemical etching, and anodic bonding techniques. Quaternary ammonium latex particles were employed for the first time to coat the separation channels on-chip. Owing to the narrow depths of the channels on the chip, 0.5-10 microm, there were more interactions of the analytes with the stationary phase on the chip than in a 50-microm I.D. capillary. With off-chip injection (20 nl) and UV detection, NO2-, NO3-, I-, and thiourea were separated using 1 mM KCl as the eluent. The linear ranges for NO2- and NO3- are from 5 to 1000 microM with the detection limits of 0.5 microM.  相似文献   

11.
Optical sensing systems for microfluidic devices: a review   总被引:1,自引:0,他引:1  
This review deals with the application of optical sensing systems for microfluidic devices. In the “off-chip approach” macro-scale optical infrastructure is coupled, while the “on-chip approach” comprises the integration of micro-optical functions into microfluidic devices. The current progress of the use of both optical sensing approaches in microfluidic devices, as well as its applications is described. In all cases, sensor size and shape profoundly affect the detection limits, due to analyte transport limitation, not to signal transduction limitation. The micro- or nanoscale sensors are limited to picomolar-order detection for practical time scales. The review concludes with an assessment of future directions of optical sensing systems for integrated microfluidic devices.  相似文献   

12.
A microfluidic device denoted the Phase Chip has been designed to measure and manipulate the phase diagram of multicomponent fluid mixtures. The Phase Chip exploits the permeation of water through poly(dimethylsiloxane) (PDMS) in order to controllably vary the concentration of solutes in aqueous nanoliter volume microdrops stored in wells. The permeation of water in the Phase Chip is modeled using the diffusion equation, and good agreement between experiment and theory is obtained. The Phase Chip operates by first creating drops of the water/solute mixture whose composition varies sequentially. Next, drops are transported down channels and guided into storage wells using surface tension forces. Finally, the solute concentration of each stored drop is simultaneously varied and measured. Two applications of the Phase Chip are presented. First, the phase diagram of a polymer/salt mixture is measured on-chip and validated off-chip, and second, protein crystallization rates are enhanced through the manipulation of the kinetics of nucleation and growth.  相似文献   

13.
Nie FQ  Macka M  Paull B 《Lab on a chip》2007,7(11):1597-1599
A micro-fluidic chip, within which two monolithic electroosmotic pumps are utilised for sample preconcentration, injection and delivery is presented. The monolithic pumps were capable of producing stable and bubble free flow rates at applied voltages below 2 kV, with a current <10 microA. Electrokinetic (EK) sample injection, down to low nano-litre volumes, was quantitatively controlled through applied voltage and injection times, whilst the sample pump delivered a carrier solution to indirectly dispense the sample. A nano-flow sensor (NFS) was used to continuously monitor the flow rate stability of each pump, showing response times of <5-10 s for changes in applied voltage. A capacitively coupled contactless conductivity detector (C(4)D), as an off-chip on-capillary detector, was used to complete the micro-flow injection analysis (FIA) system. A monolithic electroosmotic pump (EOP), modified with an anionic surfactant, was used to demonstrate a novel approach to on-chip cation preconcentration and elution.  相似文献   

14.
C X Qiu  D J Harrison 《Electrophoresis》2001,22(18):3949-3958
On-board generation of a set of calibration standards was demonstrated within a microfluidic device designed to perform immunoassay. Electrokinetic flow was used to proportionally mix the antibody (Ab) to bovine serum albumin (BSA) and a diluting buffer, to provide varying Ab concentrations for downstream mixing with fluorescently labeled BSA (BSA*). Mixing ratios were determined from electrical impedance modeling of the fluidic network using P-SPICE software, and peak heights for the labeled species were analyzed relative to the concentration calculated from the model. For dilution and separation of fluorescently labeled amino acids, a linear calibration curve was obtained for mixing ratios of 0.118 to 7.46. A linear calibration curve was obtained for the immunoassay calibration using dilution ratios between 0.197 and 5.077. Deviations were observed at larger extremes, possibly due to leakage effects at intersections. Peak height reproducibility was +/- 3% for the immunoassay, using diluted monoclonal Ab in mouse ascites fluid as the analyte. Recovery for on-chip calibration was 92 +/- 6% versus calibrants prepared off-chip, indicating a small bias.  相似文献   

15.
A sensitive on-chip acetylcholinesterase (AChE) assay that serves as a basis for the development of a fully integrated on-chip AChE-inhibitor detection assay is presented. The sequential steps required for the on-chip analysis process were integrated into a microchip. Transport and mixing of the reagents occurred by a combination of electroosmosis and electrophoresis using computer-controlled electrokinetic transport. AChE-catalyzed hydrolysis of acetylthiocholine to thiocholine was determined by on-chip reaction of thiocholine with eosinmaleimide, and the resulting thioether was electrophoretically separated and detected by laser-induced fluorescence (LIF). Enzyme-substrate mixing and reaction by confluent flow of reagents was compared with electrophoretically mediated microanalysis (EMMA), based on injection of an enzyme plug, and the utilization of differences in electrophoretic mobility as a driving force for efficient mixing and reaction. Both methods yielded similar results, however the EMMA-plug technique is preferable. The EMMA-plug technique was optimized for length and pushing time of enzyme plug, length of dyes mixture plug, acetylthiocholine concentration, and detector location. Detection of O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) and paraoxon, two AChE inhibitors, was demonstrated by off-chip mixing of the inhibitor and AChE, followed by the on-chip AChE assay. Limit of detection of VX for 5.5 min incubation and of paraoxon for 8 min incubation was 4 × 10−10 and 4 × 10−7 M, respectively. Utilization of the AChE microchip assay for inhibition kinetics was demonstrated also by evaluation of the inhibitor-enzyme bimolecular reaction constant (ki). The evaluated ki values for VX and paraoxon for AChE from the electric eel were 3.5 × 107 and 1.7 × 105 M−1 min−1, respectively, conforming well to reported values obtained by bulk methods.  相似文献   

16.
The good,the bad,and the tiny: a review of microflow cytometry   总被引:2,自引:1,他引:1  
Recent developments in microflow cytometry have concentrated on advancing technology in four main areas: (1) focusing the particles to be analyzed in the microfluidic channel, (2) miniaturization of the fluid-handling components, (3) miniaturization of the optics, and (4) integration and applications development. Strategies for focusing particles in a narrow path as they pass through the detection region include the use of focusing fluids, nozzles, and dielectrophoresis. Strategies for optics range from the use of microscope objectives to polymer waveguides or optical fibers embedded on-chip. While most investigators use off-chip fluidic control, there are a few examples of integrated valves and pumps. To date, demonstrations of applications are primarily used to establish that the microflow systems provide data of the same quality as laboratory systems, but new capabilities-such as automated sample staining-are beginning to emerge. Each of these four areas is discussed in detail in terms of the progress of development, the continuing limitations, and potential future directions for microflow cytometers.  相似文献   

17.
Monolithically integrated, polymer (SU-8) microchips comprising an electrophoretic separation unit, a sheath flow interface, and an electrospray ionization (ESI) emitter were developed to improve the speed and throughput of metabolism research. Validation of the microchip method was performed using bufuralol 1-hydroxylation via CYP450 enzymes as the model reaction. The metabolite, 1-hydroxybufuralol, was easily separated from the substrate (R(s)=0.5) with very good detection sensitivity (LOD=9.3nM), linearity (range: 50-500nM, r(2)=0.9997), and repeatability (RSD(Area)=10.3%, RSD(Migrationtime)=2.5% at 80nM concentration without internal standard). The kinetic parameters of bufuralol 1-hydroxylation determined by the microchip capillary electrophoresis (CE)-ESI/mass spectrometry (MS) method, were comparable to the values presented in literature as well as to the values determined by in-house liquid chromatography (LC)-UV. In addition to enzyme kinetics, metabolic profiling was demonstrated using authentic urine samples from healthy volunteers after intake of either tramadol or paracetamol. As a result, six metabolites of tramadol and four metabolites of paracetamol, including both phase I oxidation products and phase II conjugation products, were detected and separated from each other within 30-35s. Before analysis, the urine samples were pre-treated with on-chip, on-line liquid-phase microextraction (LPME) and the results were compared to those obtained from urine samples pre-treated with conventional C18 solid-phase extraction (SPE, off-chip cartridges). On the basis of our results, the SU-8 CE-ESI/MS microchips incorporating on-chip sample pre-treatment, injection, separation, and ESI/MS detection were proven as efficient and versatile tools for drug metabolism research.  相似文献   

18.
This paper reports on the surface modification of plastic microfluidic channels to prepare different biomolecule micropatterns using ultraviolet (UV) photografting methods. The linkage chemistry is based upon UV photopolymerization of acryl monomers to generate thin films (0.01-6 microm) chemically linked to the organic backbone of the plastic surface. The commodity thermoplastic, cyclic olefin copolymer (COC) was selected to build microfluidic chips because of its significant UV transparency and easiness for microfabrication by molding techniques. Once the polyacrylic films were grafted on the COC surface using photomasks, micropatterns of proteins, DNA, and biotinlated conjugates were readily obtained by surface chemical reactions in one or two subsequent steps. The thickness of the photografted films can be tuned from several nanometers up to several micrometers, depending on the reaction conditions. The micropatterned films can be prepared inside the microfluidic channel (on-chip) or on open COC surfaces (off-chip) with densities of functional groups about 10(-7) mol/cm2. Characterization of these films was performed by attenuated-total-reflectance IR spectroscopy, fluorescence microscopy, profilometry, atomic force microscopy, and electrokinetic methods.  相似文献   

19.
A new on-chip injector for microchip-based flow analyses has been designed and characterized. The microchip design utilizes separate laminar flow streams of buffer and sample that are brought into parallel contact for a distance of 300 microm. The buffer flow stream is first routed through a conventional 6-port injection valve fitted with a 5 microm i.d. sample loop. When the 6-port valve is actuated from load to inject for a given time, the on-chip buffer flow stream is constricted and the sample flow stream is pressurized into the buffer flow channel. Once the valve returns to the load state the separate laminar flow streams resume. Fluorescence detection was used to characterize the injector and it was found that 50 injections of a 100 microM fluorescein sample led to an average peak height of 174.32 +/- 2.05 AFU (RSD 1.18%) and average peak skew of 1.37 +/- 0.06. The injector was also interfaced with amperometric detection. Injections of catechol solutions ranging in concentration from 500 nM to 100 microM resulted in a linear response (sensitivity = 2.49 pA microM(-1), r(2) = 0.998) and a limit of detection of 155 nM (S/N = 3). Compared to an off-chip injection scheme, plug dilution, band broadening, and peak asymmetry are much reduced. Finally, the injection and subsequent lysis of an erythrocyte sample was demonstrated, with an injected plug of erythrocytes being lysed 5.72 +/- 0.15 s after injection into a flow stream containing sodium dodecyl sulfate (n = 10). The new injection scheme does not require complex valving mechanisms or high pressures and enables reproducible injections from a continuous sample flow stream in a manner where changes in analyte concentration can be monitored with high temporal resolution.  相似文献   

20.
《Analytical letters》2012,45(17):2569-2579
With the aim of obtaining stable antibody immobilization on the poly(methyl methacrylate), PMMA channel surface, PMMA substrates were activated with O2 plasma treatment to introduce surface polar groups on it. The plasma-treated PMMA surfaces were characterized using water contact angle measurement, atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). It was observed that plasma treatment significantly improved the surface wettability with changing surface chemistry and topography. The strategy of immobilization of a model antibody, anti-goat IgG on plasma-treated PMMA involved two steps. First the plasma-treated PMMA was functionalized with (3-aminopropyl)thriethoxy silane, APTES off-chip which facilitated covalent capturing of antibody via a crosslinking agent in the inner surface of PMMA channel in the second step. The antibody immobilization on plasma-treated PMMA was also confirmed using AFM, XPS, and fluorescence microscopy. The anti-IgG covalently captured on channel surface was evaluated with sandwich ELISA protocol on-chip using fluorescence microscopy. The observed results demonstrate that this technique could be extended to integrate the current diagnostic techniques into the plastic chip for important biomarker diagnosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号